| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HB6040 |
| Price Range | USD 14,000–42,000 (FOB) |
| Instrument Type | In-situ UV Absorption Flue Gas Analyzer |
| Measured Gases | SO₂, NO, NO₂, CO, CS₂, H₂S, NH₃ |
| Flow Accuracy | ≤ ±2 % FS |
| Sampling Flow Rate | 0.5–1.5 L/min |
| Flue Gas Velocity Range | 5–30 m/s |
| Moisture Content Measurement Range | 0.1–40.0 % v/v |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Model | HB6080 |
| Detection Principle | Electrochemical Sensor Technology |
| Form Factor | Portable |
| Response Time | ≤30 s |
| Target Gases | SO₂, NO, CO |
| Repeatability | ±2% FS (typical for electrochemical sensors) |
| Compliance | Meets Chinese national standards for toxic and indoor air quality gas detection (e.g., HJ 693–2014, GB/T 18204.2–2014) |
| Sensor Interface | Auto-recognizing digital sensor module |
| Enclosure Rating | IP54 (dust- and splash-resistant) |
| Power Supply | Rechargeable Li-ion battery (≥10 h continuous operation) |
| Data Output | RS232/USB interface, optional Bluetooth 5.0 |
| Operating Temperature | –10 °C to +50 °C |
| Storage Temperature | –20 °C to +60 °C |
| Brand | Airel |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CIC |
| Price | Upon Request |
| Measurement Principle | Differential Mobility Analysis (DMA) with Dual Cylindrical DMAs |
| Ion Polarity | Simultaneous Positive & Negative Cluster Ion Detection |
| Mobility Range | >0.25 cm²/V·s |
| Total Ion Concentration Range | ~10⁶ p/cm³ |
| Noise Floor | 20 #/cm³ (at 40 L/min sampling flow) |
| Response Time | ≤100 ms (minimum, signal-dependent) |
| Operating Temperature | −20 to +40 °C |
| Ambient Pressure Range | 300–1200 hPa |
| Sampling Flow Rate | 10–60 L/min per polarity (software-selectable) |
| Power Supply | DC 15 V, 0.5 A |
| Data Interface | USB |
| Software Suite | Spectops (real-time acquisition & online processing) + Retrospect (offline review & re-analysis) |
| Dimensions | H120 × W200 × L380 mm |
| Weight | 5 kg |
| Brand | Airel |
|---|---|
| Origin | Estonia |
| Manufacturer Type | Distributor |
| Import Status | Imported |
| Model | EAS |
| Pricing Range | USD 65,000–130,000 (FOB) |
| Operating Principle | Scanning Electrical Mobility Spectrometry (SEMS) |
| Sample Flow Rate | 48 L/min |
| Particle Size Range | 30–10,000 nm |
| Number Concentration Range | 100–1,000,000 particles/L |
| Size Channels | 32 |
| Mass Concentration Output | Not directly measured (derived via conversion using assumed density and shape) |
| Brand | Airel |
|---|---|
| Origin | Estonia |
| Manufacturer Type | Importer/Distributor |
| Country of Origin | Estonia |
| Model | EAS |
| Price | Upon Request |
| Brand | Airel |
|---|---|
| Origin | Estonia (Designed & Developed at University of Tartu) |
| Model | NAIS |
| Principle | Scanning Mobility Particle Sizing (SMPS) with Dual-Polarity Differential Mobility Analysis |
| Sampling Flow Rate | 54 L/min |
| Size Range | 0.8–40 nm |
| Counting Range | 100–10,000,000 particles/L |
| Size Channels | ≤150 |
| Particle Mass Concentration Capability | Not applicable (mass output not supported) |
| Brand | Airel |
|---|---|
| Origin | Estonia |
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | NAIS |
| Price | Upon Request |
| Brand | Airel |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Model | TIC |
| Measurement Principle | Parallel-Plate Electromobility Analysis with Integrated Electrometer |
| Ion Mobility Range | Z > ±0.5 cm²/V/s |
| Measured Species | Total Positive & Negative Cluster Ions |
| Flow Rate | 2–9 L/min (Standard: 5 L/min, Unipolar Mode) |
| Noise Floor | <100 ions/cm³ (at 5 L/min sample flow) |
| Response Time | 10 s (down to 1 s at high signal levels) |
| Operating Temperature | −20 to +40 °C |
| Ambient Pressure Range | 500–1200 hPa |
| Power Supply | DC 15 V, 0.5 A (nominal), 1 A (max flow) |
| Interface | USB-C Virtual Serial Port (Full Protocol Documentation Available) |
| Concentration Range | Up to ~10⁶ particles/cm³ |
| Software | Cross-Platform GUI & CLI Tools (Windows 7+, Linux), Python SDK (OS-agnostic) |
| Dimensions | H50 × W120 × L160 mm |
| Weight | 11 kg |
| Brand | Airel |
|---|---|
| Model | VLDMA |
| Type | Differential Mobility Analyzer (DMA) |
| Maximum Particle Diameter | 8,000 nm |
| Upper Mobility Range | 1.2 × 10⁻⁶ cm²/V·s |
| High-Voltage Range | ±10 kV |
| Sheath Flow Rate | 2–20 L/min |
| Sheath-to-Sample Flow Ratio | 1:10 |
| Gravity Drift Compensation | Automated for particles >4 µm |
| Interface | RJ45, Ethernet (LAN) |
| Dimensions | 165 × 57 × 57 cm |
| Weight | Not specified |
| Compatibility | Airel Aerosol Electrometer Model 202 (native), third-party CPCs/SMPS systems (optional) |
| Control Software | Integrated DMA controller with step-scan and time-delay correction modes |
| Brand | AirMetrics |
|---|---|
| Origin | USA |
| Model | MiniVol TAS |
| Flow Range | 0–10 L/min |
| Pressure Capability | >30,000 Pa |
| Flow Stability | ±5% |
| Max Flow Error | ±5% |
| Continuous Operation Time at Max Flow & Backpressure | 60 h |
| Dimensions (Sampler) | 25.4 × 30.5 × 17.8 cm |
| Weight (Fully Configured) | 4.45 kg |
| Battery | 14.8 V / 118 Wh Li-ion (≥60 h runtime, 5 h recharge) |
| Filter Format | 47 mm cassette (EPA FRM-compliant) |
| Inlet Type | EPA FRM-designated PM₁₀ or PM₂.₅ cyclonic separator |
| Power Options | AC/DC adapter (100–240 VAC, 47–63 Hz) or solar-compatible |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AirScanner |
| Price Range | USD 68,000–136,000 (FOB) |
| Pollutants Measured | O₃, NO/NO₂, CO, SO₂, CO₂, VOCs, PM₁₀, PM₂.₅ |
| Measurement Principles | UV Photometry (O₃, SO₂), Chemiluminescence (NO/NO₂), NDIR (CO, CO₂), PID (VOCs), β-Attenuation or Optical Scattering (PM) |
| Environmental Parameters | Temperature, Relative Humidity, Wind Speed & Direction, Ambient Noise, Atmospheric Pressure |
| Data Connectivity | GSM/GPRS, Ethernet (LAN/WLAN), RS-232 |
| Enclosure Rating | IP65 |
| Operating Temperature Range | −20 °C to +50 °C |
| Power Supply | 230 V AC ±10%, 50/60 Hz or Solar/Battery Hybrid Option |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Instrument Type | Online |
| Detection Principle | Hybrid Sensor Array (Metal Oxide Semiconductor, Photoionization Detector, Electrochemical Sensors) |
| Accuracy | ±2% FS |
| Flow Rate Range | 10–400 mL/min |
| Response Time | <1 s |
| Operating Temperature | −30°C to +100°C |
| Operating Humidity | 0–90% RH |
| Sensor Configuration | 4× MOS, 1× PID, 2–4× electrochemical sensors |
| Output Parameters | H₂S, NH₃, TVOC, user-selectable target odorants (1–2), and dimensionless odor unit (OU) concentration |
| Communication Interfaces | WiFi, GSM, GPRS, 3G, Ethernet |
| Data Management | Cloud database, local LAN, or open-network deployment |
| Compliance Ready | Designed for integration into GLP/GMP- and ISO 16000-compliant environmental monitoring workflows |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GDA-F |
| Weight | 2 kg |
| Sampling Method | Automatic Continuous Sampling |
| Operating Temperature | Ambient (15–30 °C) |
| Detection Range | ppb to ppm |
| Target Gases | Cl₂, HF, HCN, chlorobenzene, toluene, and other fumigants/volatile organic compounds (VOCs) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Instrument Type | Portable |
| Detection Principle | Hybrid IMS/PID/MOS/EC Sensor Fusion |
| Core Configuration | Multi-Channel VOC & Inorganic Gas Detector |
| Operating Temperature | −30 °C to 50 °C |
| Relative Humidity Range | 5–95% RH (non-condensing) |
| Power Supply | Rechargeable Li-ion Battery (30 W, 8 h runtime) |
| Weight | 4.2 kg |
| Sample Introduction | Integrated Auto-Sampling Pump with Continuous Gas Flow |
| Cycle Time | 5 min |
| Response Time | 2–60 s |
| Detection Library | >300 Pre-Calibrated Compounds (VOCs, Inorganic Gases, Electronic Specialty Gases), Expandable |
| Data Interfaces | RS-232, Ethernet, Wireless Transmission |
| Software | WinMuser GDA Suite |
| Heating Module | Integrated IR Heater for Solid/Surface Residue Volatilization |
| Alarm Logic | Template-Based Pattern Recognition with User-Configurable Thresholds |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GDA-X |
| Pricing | Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | Olfosense |
| Instrument Type | Online |
| Detection Principle | Hybrid Sensor Array (Metal Oxide Semiconductor, Photoionization Detector, Electrochemical Sensors) |
| Accuracy | ±1–2% |
| Flow Rate Range | 10–400 mL/min |
| Response Time | <1 second |
| Operating Temperature | −30°C to +100°C |
| Operating Humidity | 0–90% RH |
| Sensor Configuration | 4× MOS, 1× PID, 2–4× electrochemical sensors |
| Output Parameters | H₂S, NH₃, TVOC concentrations, user-selectable odorant(s) (1–2), and dimensionless odor unit (OU) values |
| Connectivity | WiFi/GSM/GPRS/3G |
| Data Integration | Open API, Modbus TCP/RTU, MQTT |
| Compliance | Designed for EN 13725-compliant odor assessment workflows |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN 3.5 |
| Sensor Array | 10 metal oxide semiconductor (MOS) sensors |
| Sensor Volume | 1.8 mL |
| Operating Temperature | 110 °C (sensor tube) |
| Response Time | < 1 s |
| Measurement Cycle | ~60 s (20 s exposure + 40 s recovery) |
| Sampling Flow Rate | 10–400 mL/min (integrated mass flow control) |
| Built-in Pumps | 2 (sample + zero air) |
| Zero Air Source | Activated charcoal-filtered ambient air or zero-air generator |
| Display | Integrated LCD panel |
| Interface | USB and/or RS232 |
| Digital I/O | TTL and digital signal ports |
| Operating Ambient | 0–40 °C, 5–95% RH (non-condensing) |
| Power | 30 W, 110–230 V AC or optional 12 V DC |
| Weight | 2.3 kg |
| Dimensions | 255 × 190 × 92 mm |
| Safety Compliance | IEC 61010-1 |
| Detection Limits | 0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene) |
| Software Platform | WinMuster v5.x (supports PCA, LDA, DFA, K-NN, PLS, BP-ANN) |
| Data Integrity | Audit-trail enabled |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3 |
| Sensor Array | 10 metal oxide semiconductor (MOS) sensors |
| Sensor Volume | 1.8 mL |
| Operating Temperature | 110 °C (sensor tube) |
| Response Time | <1 s |
| Measurement Cycle | ~60 s (20 s exposure + 40 s recovery) |
| Sampling Flow Rate | 10–400 mL/min (internally regulated) |
| Sampling System | Dual built-in pumps (sample + zero air) |
| Zero Air Source | Activated charcoal-filtered ambient air or zero-air generator |
| Display | Integrated LCD screen |
| Interface | USB and/or RS232 |
| Digital I/O | TTL & digital signal ports |
| Operating Ambient | 0–40 °C, 5–95% RH (non-condensing) |
| Power | 30 W, 110–230 V AC or optional 12 V DC |
| Weight | 2.3 kg |
| Dimensions | 255 × 190 × 92 mm |
| Safety Compliance | IEC 61010-1 |
| Detection Limit | 0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene) |
| Software | WinMuster v5.x (PCA, LDA, DFA, K-NN, PLS, BP-ANN) |
| OS Compatibility | Windows XP and later |
| Calibration Stability | Automated drift compensation over 12 months |
| Warranty | 1 year |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | meteo |
| Compliance | EN 13725 |
| Output Unit | Odor Units per cubic meter (OU/m³) |
| Sensor Array | 10 MOS (Metal Oxide Semiconductor) sensors |
| Data Acquisition | Continuous, 24/7 |
| Communication | Wi-Fi + optional GSM/GPRS |
| Meteorological Integration | Integrated anemometer & wind vane |
| Software Algorithms | PCA, PLS regression, Mahalanobis & Euclidean distance analysis |
| Calibration Reference | EN 13725-compliant dynamic olfactometry |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3.5 |
| Instrument Type | Portable |
| Detection Principle | Multi-sensor array (Metal Oxide Semiconductor, Electrochemical, PID) |
| Sensor Array | 10 distinct MOS sensors |
| Software Platform | WinMuster v5.x |
| Data Analysis Algorithms | PCA, LDA, DFA, K-NN (Euclidean & Mahalanobis), PLS |
| Compliance | Designed for ISO 18562-3 (biocompatibility of gas pathways), ASTM E2147-22 (odor intensity measurement), GLP-compliant audit trail support |
| Operating Environment | 5–40 °C, 20–90% RH (non-condensing) |
| Sample Introduction | Integrated auto-sampling pump with mass-flow-controlled inlet (0.1–1.0 L/min adjustable) |
| Connectivity | USB 2.0, RS-232, optional Ethernet module for remote station integration |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AKFC-92A |
| Pricing | Upon Request |
| Sampling Flow Rate | 20 L/min |
| Maximum Negative Pressure | >3000 Pa |
| Load Capacity | ≥1000 Pa |
| Dust Fraction Measurement | Total Dust & Respirable Dust |
| Timer Range | 0–99 min (adjustable) |
| Continuous Operation Time | >120 min |
| Sound Pressure Level | ≤70 dB(A) |
| Explosion Protection | ibI (150 °C) Intrinsically Safe |
| Operating Temperature | −5 °C to 35 °C |
| Relative Humidity Limit | ≤95% RH |
| Dimensions | 200 × 140 × 80 mm |
| Weight | 1.8 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | AKFC-92G |
| Pricing | Available Upon Request |
| Sampling Flow Rate | 2 L/min |
| Vacuum Pressure | >5000 Pa |
| Load Capacity | >2000 Pa |
| Dust Fraction Collection | Total Dust & Respirable Dust |
| Operating Duration | >10 h |
| Intrinsic Safety Rating | Mine-Use Intrinsically Safe (iI) |
| Acoustic Noise Level | <60 dB(A) |
| Ambient Operating Temperature | 0–35 °C |
| Relative Humidity Limit | <95% RH |
| Dimensions | 120 × 80 × 42 mm |
| Weight | 450 g |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AL-430 |
| Pricing | Available Upon Request |
| Pump Type | Diaphragm Pump |
| No-Load Flow Rate | 4 L/min |
| Flow Range Options | Dual-Range Mass Flowmeter (0.07–0.7 L/min and 0.4–4 L/min) |
| Total Volume Setting Range | 1–9999 L (LCD Display) |
| Power Supply | 8 × AA Alkaline Batteries (8 h runtime) or External DC 12 V / AC 100 V |
| Telescopic Mast | Extendable to 1.5 m (PAT-Compatible Mounting) |
| Dimensions | 240(W) × 330(H) × 350(D) mm |
| Weight | 8 kg |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ALA Level Alarm Device |
| Price | Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ALD Condensate Drain Unit |
| Pricing | Upon Request |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | PTR-TOF MS 2500 |
| Detection Principle | Proton Transfer Reaction (H₃O⁺-based soft ionization) |
| Instrument Type | Online Real-Time Analyzer |
| Configuration | Integrated VOC Monitoring System |
| Mass Resolution (m/Δm) | ≥ 6,000 (FWHM at m/z 100) |
| Mass Range | m/z 10–300 |
| Detection Limit | < 10 pptv (for formaldehyde, 1 s integration) |
| Data Acquisition Rate | Up to 10 Hz full-spectrum |
| Vacuum System | Multi-stage differential pumping with turbomolecular pumps |
| Ion Source | RF-driven hollow cathode H₃O⁺ generator |
| Mass Analyzer | Orthogonal acceleration reflectron TOF |
| Software Platform | ALIBEN Control Suite v4.2 (GLP-compliant audit trail, 21 CFR Part 11 ready) |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | PTR-TOF MS 6000 |
| Detection Principle | Proton Transfer Reaction (H₃O⁺-based soft ionization) |
| Instrument Type | Online Real-time Analyzer |
| Configuration | Integrated VOCs Monitoring System |
| Mass Resolution (m/Δm) | ≥ 6,000 (FWHM at m/z 100) |
| Mass Range | m/z 10–500 |
| Detection Limit | < 10 pptv (for common VOCs, 1-s integration) |
| Response Time | < 100 ms |
| Vacuum System | Multi-stage differential pumping with turbomolecular pumps |
| Ion Source | Radiofrequency-guided H₃O⁺ primary ion source |
| Analyzer | Orthogonal acceleration reflectron TOF mass analyzer |
| Data Acquisition Rate | Up to 10 spectra per second |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | PTR-TOF MS 8000 |
| Detection Principle | Proton Transfer Reaction (H₃O⁺-based soft ionization) |
| Instrument Type | Online Real-Time Analyzer |
| Configuration | Integrated VOCs Monitoring System |
| Mass Resolution (m/Δm) | ≥ 8,000 (FWHM at m/z 100) |
| Mass Range | m/z 10–500 |
| Detection Limit | < 10 pptv (for common VOCs, 1-s integration) |
| Data Acquisition Rate | Up to 10 Hz full-spectrum acquisition |
| Vacuum System | Multi-stage differential pumping with turbomolecular pumps |
| Ion Source | RF-driven hollow cathode H₃O⁺ generator |
| Mass Analyzer | Orthogonal acceleration reflectron TOF |
| Software Platform | ALIBEN Acquire v3.2 with real-time spectral deconvolution and compound identification engine |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UVP-TOF MS 2000 LITE |
| Detection Principle | Vacuum Ultraviolet Photoionization (VUV-PI) coupled with Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Analyzer |
| Configuration | Multi-Component VOC & Inorganic Gas Monitor |
| Detection Range | 0–1 ppbv (extendable to % v/v) |
| Mass Resolution (FWHM) | >2000 |
| Accuracy | RSD <3% |
| Response Time | <1 s |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Domestic |
| Model | UVP-TOF MS 2000 PLUS |
| Detection Principle | Vacuum Ultraviolet Photoionization + Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Analyzer |
| Configuration | Multi-Component VOC Monitor |
| Sampling Method | Direct Gas Inlet |
| Detection Range | 100 pptv – 1 ppmv |
| Mass Resolution (FWHM) | >2500 |
| Accuracy (RSD) | <3% |
| Response Time | <0.5 s |