Gas Detector
Filter
Showing 61–90 of 2711 results
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AAM Adsorbent Material Filter |
| Price | Upon Request |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | GLA131-GGA |
| Detection Gases | CH₄ (0–100 ppm, optional 0–5%), CO₂ (0–20,000 ppm), H₂O (0–30,000 ppm) |
| Response Time | 3 s (1/e) |
| Warm-up to Data Logging | ≤20 s |
| Dimensions | 12 cm H × 34 cm W × 29.5 cm D |
| Weight (incl. battery) | <5.5 kg |
| Power Consumption | <35 W |
| Precision (1σ, 1s/10s/100s) | CH₄: 1 ppb / 0.4 ppb / 0.2 ppb |
| CO₂ | 0.4 ppm / 0.2 ppm / 0.1 ppm |
| H₂O | 200 ppm / 60 ppm / 30 ppm |
| Operating Temperature | 5–45 °C |
| Sample Temperature Range | −40–50 °C |
| Relative Humidity | 0–98% RH (non-condensing) |
| Data Output | SD card storage, Wi-Fi, USB, Ethernet, analog outputs |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA132 |
| Price | Upon Request |
| Accuracy | < 1% uncertainty (uncalibrated, 5–45 °C) |
| Measured Gases & Ranges | CH₄ (0.01–100 ppm), CO₂ (200–20,000 ppm), NH₃ (1–10,000 ppb), H₂O (500–30,000 ppm) |
| Detection Principle | Fourth-Generation Cavity-Enhanced Absorption Spectroscopy (CEAS) |
| Power Consumption | < 70 W |
| Warm-up Time | < 2 min |
| Data Output Rate | 0.01–1 Hz (user-selectable) |
| Operating Temperature | 5–45 °C |
| Sample Temperature Range | −10–50 °C |
| Relative Humidity | 0–98% RH (non-condensing) |
| Dimensions | 47 × 35.6 × 17.8 cm (18.5″ × 14″ × 7″) |
| Weight | 17 kg |
| Compliance | CE, RoHS, FCC Class A |
| Data Storage | Internal Linux-based SSD with indefinite logging |
| Remote Access | Web-based GUI via Ethernet (HTTPS), full instrument control and diagnostics |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA133 |
| Detection Gases & Ranges | CH₄ (0–100 ppm standard |
| Response Time | 2.5 Hz (1/e) |
| Power Consumption | <35 W |
| Weight | <3 kg |
| Measurement Rate | Up to 10 Hz |
| Technology | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA151-N2OCM |
| Price | Upon Request |
| Measured Gases & Ranges | Simultaneous N₂O and CO detection |
| Detection Limits (1σ, 10 sec) | N₂O ≤ 0.2 ppb, CO ≤ 0.2 ppb, H₂O ≤ 40 ppm |
| Linear Range | N₂O up to 4 ppm, CO up to 4 ppm, H₂O up to 30,000 ppm |
| Operating Temperature | 5–45 °C |
| Relative Humidity | <99% RH (non-condensing) |
| Measurement Rate | 0.01–10 Hz (user-selectable) |
| Flow Response Time | <30 s (1/e), <10 s (1/e) with ACC-DP3H external diaphragm pump |
| Water Vapor Correction | Real-time spectroscopic correction for dilution and pressure broadening effects |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | GLA231 |
| Detection Gases | H₂O, NH₃, HCl, HF |
| Detection Range | Sub-ppb to % level (gas-dependent) |
| Output Options | 0–5 V DC, 4–20 mA, Modbus TCP (optional) |
| Operating System | Embedded Linux |
| Data Storage | Internal HDD with full spectral logging |
| Remote Access | Web-based GUI via Ethernet/IP |
| Calibration | Factory-certified, field-zero capable |
| Display | Integrated touchscreen interface |
| Security | Password-protected configuration and data access |
| Compliance | Designed for industrial process safety and AMC monitoring per SEMI F21, ISO 14644-8, and EPA Method TO-15 context |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA331-GGA |
| Price | Upon Request |
| Measured Gases & Ranges | CH₄ (0–100 ppm), CO₂ (0–20,000 ppm), H₂O (0–30,000 ppm) |
| Measurement Speed | Up to 10 Hz (GGA configuration) |
| CH₄ Precision (1σ, 1 s / 10 s / 100 s) | 0.6 ppb / 0.2 ppb / 0.1 ppb |
| CO₂ Precision (1σ, 1 s / 10 s / 100 s) | 150 ppb / 50 ppb / 20 ppb |
| H₂O Precision (1σ, 1 s / 10 s / 100 s) | 150 ppm / 50 ppm / 17 ppm |
| Maximum Drift (15-min avg, STP, 24 h) | CH₄ < 3 ppb, CO₂ < 0.2 ppm |
| Flow Response Time (1/e) | <10 s (standard), 0.1 s (with optional ACC-DS35 dry scroll pump) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | GLA351-N2OCM |
| Detection Gases & Ranges | N₂O (0–4 ppm, extended to 40 ppm), CO (0–4 ppm, extended to 40 ppm), H₂O (0–30,000 ppm, <99% RH, non-condensing) |
| Accuracy (1σ, 1 s / 10 s / 100 s) | N₂O: 0.1 / 0.04 / 0.02 ppb |
| CO | 0.2 / 0.06 / 0.03 ppb |
| H₂O | 50 / 20 / 10 ppm |
| Max Drift (24 h, STP, 15-min avg) | N₂O <1 ppb, CO <1 ppb |
| Measurement Rate | 0.01–1 Hz (standard), up to 10 Hz with high-flow option |
| Flow Response Time | <12 s (1/e), <10 s with high-flow option |
| Data Outputs | Ethernet, Wi-Fi, USB, RS-232 |
| Power | 110/240 VAC, 50/60 Hz |
| Dimensions | 50 × 48 × 86 cm (H×W×L) |
| Weight | 68 kg |
| Brand | ABB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LGR |
| Price Range | USD 14,000 – 42,500 |
| Measurement Principle | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Target Analytes | Hydrogen Chloride (HCl), Hydrogen Fluoride (HF), Water Vapor (H₂O) |
| Detection Limits (1σ) | HF < 0.1 ppb (1 s), HCl < 0.4 ppb (1 s) |
| Response Time | < 2 s (with external N920 vacuum pump) |
| Measurement Range | HF: 0.3–20,000 ppb |
| HCl | 0.3–2,000 ppb |
| H₂O | 10–20,000 ppm (non-condensing) |
| Operating Range | HF: 0–10 ppm |
| HCl | 0–10 ppm |
| Stability | Ultra-low drift via proprietary temperature-controlled optical architecture |
| Data System | Embedded Linux computer with local storage, Ethernet/IP remote access, real-time spectral visualization |
| Compliance | Designed for EPA Method TO-15 / ASTM D6348-18 alignment |
| Brand | ABB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MAO2020-Limas21 |
| Pricing | Upon Request |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MBGAS-3000 |
| Instrument Type | Multi-component FTIR Flue Gas Analyzer |
| Measurement Principle | Fourier Transform Infrared Spectroscopy |
| Max. Simultaneous Components | 25 |
| Accuracy (Relative Error) | ≤4% FS |
| Repeatability | ≤2% RSD |
| Response Time (T90) | ≤80 s |
| Long-term Stability (7-day drift) | ≤4% FS |
| Operating Mode | Hot/Wet Sampling |
| Detection of Water-Soluble Gases | HCl, HF, NH₃, SO₂, NO, NO₂, CO, CO₂, CH₄, N₂O, etc. |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MBGAS-3000 |
| Instrument Type | Multi-component FTIR Flue Gas Analyzer |
| Measurement Principle | Fourier Transform Infrared Spectroscopy |
| Max. Simultaneous Components | 25 |
| Accuracy (Linearity & Span Error) | ≤ ±3% of full scale |
| Repeatability | ≤ 2% RSD |
| Response Time (T90) | ≤ 90 s |
| Long-term Stability (7-day drift) | ≤ 3% of full scale |
| Operating Mode | Hot/Wet Sampling |
| Optical Resolution | ≤ 0.5 cm⁻¹ |
| Laser Source Lifetime | ≥ 10 years |
| Compliance | Designed for EN 15267-3, EN 14181, ISO 12039, and US EPA Methods 320 & OTM-12 |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | Sensi+ |
| Detection Gases & Ranges | H₂S, H₂O, CO₂ in natural gas |
| Response Time | Simultaneous continuous monitoring |
| Technology Principle | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Application Field | Oil & Gas transmission and processing |
| Certifications | ATEX/IECEx Zone 1 certified |
| Installation | Wall-mounted, direct pipeline tap-in |
| Sample Flow Requirement | ~1/6 of conventional analyzers |
| Calibration | Factory-calibrated, zero maintenance calibration in field operation |
| Software Features | AnalyzerExpert™ with real-time interference compensation, laser beam lock, health monitoring, and self-diagnostics |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | EL3000 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Accuracy | ≤ 1% of full scale |
| CO₂ Measurement Range | 0–5 ppm to 95–100 vol% |
| Response Time (T₉₀) | 2.5 s |
| Repeatability | ≤ 0.5% of full scale |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ACC Amide Compressor Cooler |
| Pricing | Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACC Environmental Pre-Cooler |
| Pricing | Available Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACP-ASR25 |
| Pricing | Available Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ACV Condensate Collector |
| Pricing | Upon Request |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | 6866 |
| Sensor Type | Explosion-Proof Thermal Conductivity Detector (TCD) |
| Mounting | DIN Rail |
| Output | 4–20 mA (isolated), RS232 (9600 baud, ASCII, RTS/CTS) |
| Measurand | H₂ in N₂ or Ar (0–10%, 0–30%, 0–100%), He in Ar (0–10%, 0–30%, 0–100%), N₂ in N₂O (75–100%, 0–100%), etc. |
| Operating Temp | −20 °C to +50 °C |
| Sample Pressure | 1 bar ±100 mbar (abs. max 10 bar) |
| Sample Flow | 100–300 mL/min |
| Accuracy | ±1% FS |
| Repeatability | ±0.5% FS |
| Resolution | 0.1% FS |
| Power | 24 VDC ±10%, ≤10 W |
| Enclosure | IP65-rated DIN rail housing (85 × 100 × 35 mm) |
| Certifications | ATEX II 2G EEx d IIB + H₂ T6/T3, EMC Directive 89/336/EEC, Low Voltage Directive 73/23/EEC |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8866 |
| Price | USD 12,200 (FOB) |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | 8866TR |
| Detection Principle | Thermal Conductivity Differential Measurement |
| Measurable Gases | He, H₂, CH₄, Ar, CO₂, SO₂, HC |
| Range Options | 0–1% to 0–100%, including narrow bands (e.g., 80–100%, 95–100%, 98–100%) |
| Accuracy | ±1% FS |
| Repeatability | ≤0.3% FS |
| Linearity Error | ≤1% FS |
| Response Time (t₆₀) | H₂ <13 s, CO₂ <23 s |
| Flow Rate | 100 mL/min – 2 L/min |
| Sample Interface | 1/4" or 6 mm compression fitting |
| Analog Output | 4–20 mA (up to 4 channels) |
| Digital Interface | RS232 / RS485 |
| Sensor Housing Materials | 316SS, 303SS, Pt–Ir alloy, borosilicate glass, PTFE, FKM |
| Power Supply | 24 VDC / 50 VA or 115–220 VAC, 50/60 Hz, 40 VA |
| Weight | 8.5 kg |
| Dimensions (W×H×D) | 180 × 155 × 325 mm |
| Enclosure Rating | IP65 |
| Explosion Protection | ATEX II 2G Ex d IIC T6 Gb / II 2D Ex tb IIIC T85°C Db, suitable for Zone 1 & Zone 21 |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | 8869 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Nondispersive Infrared (NDIR) |
| Measured Gas | CO (single-component configuration) |
| Range | 0–5000 ppm |
| Repeatability | ±1% FS |
| Resolution | 0.1% of full scale |
| Response Time (T90) | ≤15 s |
| Zero Drift | ≤1% FS/month |
| Span Drift | ≤1% FS/month |
| Linearity Error | ±1% FS |
| Temperature & Pressure Compensation | Yes |
| Output Signals | 4–20 mA (isolated), RS-485 (Modbus RTU) |
| Display | Backlit LCD |
| Enclosure Rating | ATEX II 2G Ex d IIC T6 Gb / CSA Class I, Division 2, Groups A–D |
| Installation | 19″ rack-mount, panel-mount, or benchtop |
| Operating Environment | −5 °C to +45 °C, <90% RH (non-condensing) |
| Sample Inlet | Rc¼ or NPT¼ |
| Sample Flow Rate | 0.25–2 L/min |
| Sample Pressure | ±0.5 to ±1.5 bar(g) |
| Sample Temperature | 0–50 °C |
| Sample Humidity | <90% RH |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FS-2 |
| Instrument Type | Portable |
| Detectable Gases | H₂, NH₃ |
| Response Time | ≤5 s |
| Measurement Accuracy | ±1 ppm (for NH₃ and H₂ at low-range configurations) |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm (user-selectable per gas channel) |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | FS-200 |
| Instrument Type | Portable Gas Detector |
| Detectable Gases | H₂, NH₃, SF₆ |
| Response Time (T90) | ≤5 s |
| Measurement Accuracy | ±1% of Full Scale |
| Measurement Range | ppm to 100% vol |
| Sensor Principle | Electrochemical (H₂/NH₃), Optional Catalytic Bead / Infrared / Thermal Conductivity |
| Display | 2.5" 320×240 Color TFT Screen |
| Operating Temperature | −40 °C to +70 °C |
| IP Rating | IP66 |
| Explosion Protection | Ex d IIC T6 Gb / Intrinsic Safety Certified |
| Dimensions | 180 × 78 × 33 mm |
| Weight | 350 g |
| Power Supply | Rechargeable 3.6 V DC / 5000 mAh Polymer Battery |
| Data Storage | 100,000 records (configurable interval) |
| Communication | USB, RS232, Infrared |
| Compliance | ATEX, IECEx, EN 60079-0/11/26, ISO 9001, CE |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FS300 |
| Pricing | Available Upon Request |
| SF₆ Moisture (Dew Point) | −80 to +20 °C (±0.5 °C accuracy, ±0.5 °C repeatability) |
| SF₆ Purity | 0–100 % (±0.1 % accuracy & repeatability, T₉₀ ≤ 15 s) |
| Decomposition Gases | H₂S (0–200 ppm), SO₂ + SOF₂ (0–100 ppm / 0–2000 ppm dual range), CO (0–5000 ppm), HF (0–10 ppm) |
| Display | 800 × 480 pixel true-color TFT touchscreen |
| Dimensions | 420 × 150 × 325 mm |
| Weight | 5.5 kg |
| Power | AC/DC operation |
| Data Storage | 128 entries (expandable), USB export support |
| Interface | Self-sealing quick-connect gas fittings, USB port |
| Temperature Compensation | Dual-sensor thermal compensation architecture |
| Brand | ADEV |
|---|---|
| Origin | Beijing, China |
| Model | FY-1000 |
| Instrument Type | Fixed-mount online analyzer |
| Detection Targets | O₂, CH₄, CO, CO₂, H₂S, H₂, SO₂, NO, NO₂, N₂, HCs, BrCH₃, SO₂F₂, Ar, He, NH₃, SF₆ |
| Measurement Range | 0.1 ppm to 100% vol (configurable per gas) |
| Repeatability | ±1% FS |
| Resolution | 0.1 ppm |
| Response Time (T₉₀) | ≤30 s (varies by sensor type) |
| Zero Drift | ±2% FS / month |
| Span Drift | ±1% FS / month |
| Linearity Error | ±2% FS |
| Output | 4–20 mA analog, digital display, relay outputs (alarm & fault), remote sampling capable |
| Power Supply | 110/220/240 V AC, 50/60 Hz |
| Power Consumption | 13 W typical |
| Enclosure Rating | IP54 |
| Operating Temperature | 0–40 °C |
| Weight | 2.7 kg |
| Brand | ADEV |
|---|---|
| Model | GAS400 |
| Gas Detection Principle | Electrochemical (EC), Non-Dispersive Infrared (NDIR), Thermal Conductivity (TCD), Paramagnetic, Photoionization (PID) |
| Measurable Gases | CH₄, CO₂, O₂, CO, H₂S, H₂, SO₂, NO, NO₂, NH₃, SF₆, CₓHᵧ (HC), BrCH₃, SO₂F₂, Ar, He, N₂, Cl₂ (optional), etc. |
| Measurement Ranges | O₂ (0–100% vol), CH₄ (0–100% vol), CO₂ (0–100% vol), CO (0–5000 ppm), H₂S (0–10,000 ppm), H₂ (0–100% vol), SO₂/NO/NO₂ (0–2000 ppm), NH₃ (0–200 ppm), SF₆ (0–100% vol), HC (0–9999 ppm or 0–100% vol) |
| Accuracy | ±2% to ±2.5% FS depending on gas and sensor type |
| Response Time (T₉₀) | 15–30 s |
| Output | 4–20 mA, 0–10 mA, RS485 Modbus RTU |
| Alarm Outputs | Relay (265 VAC / 1 A), Visual/Audible Interface |
| Enclosure | 19" Rack-Mount (Online) |
| Operating Temp | –20 to +50 °C (Ambient), –10 to +600 °C (Flue Gas Probe, optional) |
| Power Supply | 220 VAC ±10%, 50 Hz ±5% |
| Dimensions (Online) | 483 × 303 × 177 mm |
| Weight (Online) | 5.0 kg |
| Brand | ADEV |
|---|---|
| Model | GAS600R |
| Type | Portable Flue Gas / Fuel Gas Calorific Value Analyzer |
| Measurement Principle | NDIR (CO, CO₂, CH₄, CₙHₘ), TCD (H₂), Electrochemical (O₂) |
| Accuracy | ≤±1% FS (NDIR sensors), ≤±2% FS (TCD & electrochemical sensors) |
| Repeatability | ≤1% |
| Response Time (T90) | <10 s (NDIR), <15 s (full system) |
| Stability | ±2% over 8 h |
| Detection Range | CO: 0–75%, CO₂: 0–25%, CH₄: 0–40%, H₂: 0–75%, O₂: 0–25%, CₙHₘ: 0–5% |
| Resolution | 0.01% for all gases |
| Operating Pressure | −10 MPa to +15 MPa |
| Sample Temperature | 80–150 °C |
| Sample Flow Rate | 0.3–1.0 L/min |
| Inlet Pressure | 2–50 kPa |
| Power Supply | Internal rechargeable Li-ion battery (12.6 V external charger) |
| Outputs | RS-232 digital, 4–20 mA analog |
| Sample Requirements | Dust-free, dry, oil-free |
| Compliance | Designed for industrial process gas monitoring per ISO 14687, ASTM D1826, and EN 15403 principles |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HLP-He |
| Price | USD 13,800 (FOB) |
| Brand | ADEV |
|---|---|
| Origin | Italy |
| Model | M860 |
| Measurement Principle | Thermal Conductivity Detection |
| Gas Specificity | SF₆ in Binary Mixtures (e.g., SF₆/N₂, SF₆/air, SF₆/CF₄) |
| Range | 0–100% SF₆ by Volume |
| Accuracy | ±0.2% FS (flow-independent) |
| Response Time | t₆₀ = 20 s, t₉₀ = 45 s |
| Operating Temperature | −30 °C to +50 °C (optimal accuracy maintained across full range) |
| Sample Flow Rate | 0.2–0.5 L/min |
| Display | High-contrast LCD, 0.1% SF₆ resolution |
| Power Supply | Rechargeable Li-ion battery (integrated, with overcharge/over-discharge protection) + AC adapter |
| Dimensions | 248 × 230 × 98 mm |
| Weight | 2.5 kg |
| Built-in Components | Precision pressure regulator, particulate filter, laminar flow meter |
| Enclosure | Ruggedized shock-absorbing transport case compliant with IEC 60068-2-64 for field deployment |