Gas Detector
Filter
Showing 181–210 of 1026 results
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | PTR-TOF MS 6000 |
| Detection Principle | Proton Transfer Reaction (H₃O⁺-based soft ionization) |
| Instrument Type | Online Real-time Analyzer |
| Configuration | Integrated VOCs Monitoring System |
| Mass Resolution (m/Δm) | ≥ 6,000 (FWHM at m/z 100) |
| Mass Range | m/z 10–500 |
| Detection Limit | < 10 pptv (for common VOCs, 1-s integration) |
| Response Time | < 100 ms |
| Vacuum System | Multi-stage differential pumping with turbomolecular pumps |
| Ion Source | Radiofrequency-guided H₃O⁺ primary ion source |
| Analyzer | Orthogonal acceleration reflectron TOF mass analyzer |
| Data Acquisition Rate | Up to 10 spectra per second |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | PTR-TOF MS 8000 |
| Detection Principle | Proton Transfer Reaction (H₃O⁺-based soft ionization) |
| Instrument Type | Online Real-Time Analyzer |
| Configuration | Integrated VOCs Monitoring System |
| Mass Resolution (m/Δm) | ≥ 8,000 (FWHM at m/z 100) |
| Mass Range | m/z 10–500 |
| Detection Limit | < 10 pptv (for common VOCs, 1-s integration) |
| Data Acquisition Rate | Up to 10 Hz full-spectrum acquisition |
| Vacuum System | Multi-stage differential pumping with turbomolecular pumps |
| Ion Source | RF-driven hollow cathode H₃O⁺ generator |
| Mass Analyzer | Orthogonal acceleration reflectron TOF |
| Software Platform | ALIBEN Acquire v3.2 with real-time spectral deconvolution and compound identification engine |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | UVP-TOF MS 2000 LITE |
| Detection Principle | Vacuum Ultraviolet Photoionization (VUV-PI) coupled with Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Analyzer |
| Configuration | Multi-Component VOC & Inorganic Gas Monitor |
| Detection Range | 0–1 ppbv (extendable to % v/v) |
| Mass Resolution (FWHM) | >2000 |
| Accuracy | RSD <3% |
| Response Time | <1 s |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Domestic |
| Model | UVP-TOF MS 2000 PLUS |
| Detection Principle | Vacuum Ultraviolet Photoionization + Time-of-Flight Mass Spectrometry |
| Instrument Type | Online Analyzer |
| Configuration | Multi-Component VOC Monitor |
| Sampling Method | Direct Gas Inlet |
| Detection Range | 100 pptv – 1 ppmv |
| Mass Resolution (FWHM) | >2500 |
| Accuracy (RSD) | <3% |
| Response Time | <0.5 s |
| Brand | ALPHA (USA) |
|---|---|
| Origin | USA |
| Model | AIC3Pro |
| Instrument Type | Handheld |
| Flow Mode | Low-flow Gerdien Tube Design |
| Repeatability | ±5% |
| Accuracy | ±20%* |
| Ion Concentration Range | 0–2×10⁶ ions/cm³ or 0–2×10⁸ ions/cm³ (selectable) |
| Resolution | 10 ions/cm³ @ 2×10⁶ range |
| Polarity Modes | Unipolar (Positive/Negative) or Bipolar (with real-time Sum calculation) |
| Polarity Switching Interval (Bipolar) | 7.5 s per polarity |
| Data Logging | Timestamped CSV to removable microSD (up to 32 GB) |
| Display | 128×128 px backlit LCD |
| Battery | 2000 mAh rechargeable Li-ion (UN38.3 certified) |
| Operating Environment | –20 °C to +43 °C, 0–85% RH (non-condensing), wind <15 km/h |
| Humidity Sensor Accuracy | ±2% RH |
| Compliance | FCC Part 15, CE EMC (BS EN 55032:2015/Cor1:2016 |
| BS EN 61000-3-2 | 2019 |
| BS EN 61000-3-3 | 2013+A1:2017 |
| BS EN 55035 | 2017/A11:2020), RoHS (EN 50581:2012) |
| Brand | ALPHA (UK) |
|---|---|
| Origin | United Kingdom |
| Model | DS2000 |
| Sensor Technology | Aluminium Oxide Capacitive |
| Measurement Range | -110°C to +20°C dew point |
| Accuracy | ±2°C over full scale |
| Display | Dual-color 7-segment, 5-digit main + 1-digit auxiliary |
| Operating Temperature | -20°C to +50°C |
| Storage Temperature | -50°C to +70°C |
| Humidity Range | 10–90% RH (non-condensing) |
| Output Options | 4–20 mA / 0–10 V linear retransmission |
| Communication | RS-485 Modbus RTU |
| Compliance | Traceable calibration to NPL and ISO/IEC 17025 accredited standards |
| Gas Compatibility | Fully compatible with SF₆, compressed air, nitrogen, argon, hydrogen, and other inert/dry process gases |
| Units Supported | °C dp, °F dp, ppm(v), g/m³, lb/MMSCF |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | AIOLOS |
| Gas Channels | 2–4 configurable |
| Inlet Pressure | 3 bar (up to 8 bar, 1 bar for LNG) |
| Outlet Pressure | Ambient (custom higher pressure available) |
| Connection | 1/8″ Swagelok |
| Dilution Ratio | Standard 1:4000, up to 1:10,000 |
| MFC Flow Range | 2–100% FS |
| Flow Accuracy | ±1% of setpoint |
| Repeatability | <0.1% of setpoint |
| Response Time | <5 s |
| Operating Temperature | 10–50 °C |
| Power Supply | 90–260 VAC, 1.5–4 A, 50–60 Hz |
| Dimensions | 42 × 22 × 46 cm (H×W×D) |
| Weight | 10.5–17.5 kg (configuration-dependent) |
| Communication | USB, Windows 7+ compatible |
| Software | Alytech GasMix™ v4.x with audit trail, sequence programming, and external device triggering |
| Compliance | ISO 6145-7 |
| Optional | Heated tubing module, remote automated calibration interface |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | AURA II |
| Evaporation Temperature Range | 40–160 °C |
| Input Pressure Range | 2–50 bar (with safety valve) |
| Output Pressure Range | 1–3 bar |
| Output Flow Rate | 20–200 cc/min |
| Operating Modes | Pressure-controlled or Flow-controlled |
| Integrated In-line Filter | 0.5 µm stainless steel |
| Standard Delivery | 1 m heated flexible transfer line |
| Power Supply | External AC adapter (battery option not specified for AURA II) |
| Accuracy | <1.5% |
| Repeatability | <1% |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | GMRACK |
| Channel Configuration | 2–6 configurable channels |
| Control Interface | Optional integrated touchscreen or external PC control |
| Power Supply | Line-powered (with optional battery for field mobility) |
| Compliance | Designed for ISO/IEC 17025-compliant calibration laboratories and EPA Method TO-14/TO-15 traceable gas standard generation |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | HURRICANE |
| Channel Capacity | 5–16 channels |
| Dilution Principle | Dynamic mass-flow-based dilution with integrated zero-air generator and permeation source support |
| Operating Mode | Portable or benchtop |
| Power | Rechargeable battery (8 h runtime) or AC mains |
| Zero Air Supply | Built-in oil-free air pump (5 L/min, filtered & dried) |
| Max Output Flow | 3000 NmL/min |
| Dilution Accuracy | < ±1.5% of setpoint |
| Reproducibility | < ±1% RSD |
| Compliance | Designed for ISO 6145-7, ISO 16017-1, ASTM D6196, EPA TO-15/TO-17 calibration traceability frameworks |
| Brand | AlyTech |
|---|---|
| Origin | France |
| Model | NEPHOS |
| Liquid Channels | 1 or 2 |
| Liquid Flow Range | 0.5–5 g/h and 0.5–200 g/h |
| Liquid Compatibility | Pure liquids or homogeneous liquid mixtures (e.g., water, organic solvents) |
| Gas Channels | 1–6 |
| Inlet Pressure | 3 bar (max 8 bar) |
| Compatible Gases | High-purity gases, concentrated standards, most corrosive and reactive gases (custom validation required for specialty gases) |
| Max Dilution Ratio | 1:10⁸ |
| Output Flow Accuracy | < ±2% of reading |
| Output Concentration Accuracy | < ±1% |
| Heated Transfer Line | Standard 1 m (custom lengths available) |
| Outlet Pressure | Ambient (higher pressure options on request) |
| Fitting Interfaces | Swagelok 1/8", 1/16", and 1/4" |
| Operating Temperature | 10–50 °C |
| Power Supply | 90–260 VAC, 1.5–4 A, 50–60 Hz |
| Dimensions (H×W×D) | 50 × 47 × 58 cm |
| Weight | 25–40 kg (configuration-dependent) |
| Communication | Ethernet, Windows 10+ PC host |
| Software | AlyTech LiqMix™ v3.x (NIST-traceable MFC & Coriolis calibration |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | NOMAD |
| Channels | 2–4 |
| Form Factor | Compact portable unit |
| Power Supply | Mains-powered (optional external PC interface) |
| Display | Optional integrated touchscreen or remote control via PC |
| Compliance | Designed for traceable gas standard generation in environmental and calibration laboratories |
| Pricing Range | USD $13,500 – $40,500 (FOB Europe, excluding VAT & shipping) |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | PerMix ATMO |
| Temperature Control Range | 40–70 °C (stability ±0.1 °C) |
| Zero Gas Generation | Integrated purified air generator (5 L/min) |
| Output Flow | Up to 3000 Nml/min |
| Power | Rechargeable battery (8 h operation) |
| Accuracy | <1.5% |
| Repeatability | <1% |
| Permeation Channels | 2 |
| Diluent | Purified ambient air |
| Brand | Alytech |
|---|---|
| Origin | France |
| Model | Zephyr |
| Configuration | Portable Dual-Channel Dynamic Gas Dilutor |
| Display | Integrated Touchscreen Interface |
| Power Options | AC Mains or Rechargeable Battery (8 h runtime) |
| Diluent Gas | Purified Air (5 L/min built-in compressor) |
| Maximum Output Flow | 3000 NmL/min |
| Accuracy | < ±1.5% of setpoint |
| Repeatability | < ±1.0% |
| Operating Temperature Range | Ambient to 40°C (external environment) |
| Compliance | Designed for ISO 6145-7 (dynamic dilution), ASTM D6166 (calibration gas generation), and GLP-compliant traceable calibration workflows |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AC-3072C |
| Instrument Type | Flue Gas Sampler |
| Sampling Flow Rate | 200–2000 mL/min |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AC-5000A |
| Instrument Type | Flue Gas and Ambient Air VOC Sampler |
| Sampling Flow Rate | 10–200 mL/min |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | ADS-2062E (2.0) |
| Application | TSP, PM10, PM2.5, and gaseous pollutants (SO₂, NOₓ) sampling via filter gravimetry and impinger absorption |
| Flow Range | 0.1–100 L/min (dual-channel independent control) |
| Load Capacity | >9 kPa at 100 L/min |
| Power Supply | Integrated rechargeable Li-ion battery (6–8 h operation at standard flow) |
| Weight | <4 kg (including thermoelectric temperature control module) |
| Compliance | HJ 618–2011, HJ 93–2013, HJ/T 374–2007, HJ/T 375–2007, HJ/T 376–2007, JJG 943–2011, JJG 956–2013 |
| Brand | AMAE |
|---|---|
| Model | CCZ30 |
| Type | Personal/Stationary Intrinsically Safe Dust Sampler |
| Flow Range | 3–30 L/min |
| Flow Resolution | 0.01 L/min |
| Compliance | GBZ 159-2004, GBZ/T 192.1–192.2, GB 16238-1996, GB 16248-1996, GBZ/T 300 (Dust), GBZ 2.1-2019 |
| Sampling Modes | Manual, Timed, Volume-Controlled, Cyclic |
| Data Logging | Internal Storage with Export (USB) & Optional Thermal Printout |
| Power | Rechargeable Li-ion Battery (High-Capacity, Extended Runtime) |
| Pump Type | Imported Brushless Electromagnetic Diaphragm Pump |
| Flowmeter | Imported Straight-Through Electronic Mass Flow Sensor |
| Accessories Included | Total Dust & Respirable Dust Sampling Heads (Φ40 mm), Filter Holders, Calibration Orifice, Tripod, Charger |
| Brand | AMAE |
|---|---|
| Model | CCZ5(A) |
| Application | Personal sampling of respirable and total dust in underground mines and occupational environments |
| Flow Range | 1000–6000 mL/min |
| Flow Resolution | 1 mL/min |
| Certifications | IECEx/ATEX Zone 0 (Class I, Div 1) & Zone 2 (Class II, Div 2) compliant |
| Compliance | GBZ 159-2004, GBZ/T 160 series, GBZ/T 300 series, GBZ 2.1-2019 |
| Power | Rechargeable Li-ion battery with >16 h continuous operation at 2 L/min |
| Environmental Rating | IP65 |
| Data Storage | Internal non-volatile memory (≥10,000 sample records) |
| Interface | USB-C for data export |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | ≤95 % RH (non-condensing) |
| Brand | AMAE |
|---|---|
| Model | CQB1500 |
| Type | Portable Intrinsically Safe Air Sampler |
| Certified Explosion-Proof Classes | I (Coal Mine) & II (Industrial Gas) |
| Flow Range | 10–2010 mL/min |
| Flow Resolution | 1 mL/min |
| Compliance | GBZ 159–2004, GBZ/T 160 series, GBZ/T 300 series, GBZ 2.1–2019 |
| Sampling Media Compatibility | Absorption Solutions, Sorbent Tubes, Filter Media |
| Operating Environment | -10 °C to +50 °C, ≤95% RH (non-condensing) |
| Battery Runtime | ≥12 h (typical at 500 mL/min) |
| Data Storage | Internal non-volatile memory (≥10,000 sample records) |
| Atmospheric Pressure Measurement | Integrated sensor (range: 60–115 kPa, accuracy: ±0.5 kPa) |
| Temperature Compensation | Built-in thermistor (±0.5 °C accuracy) |
| Standard Volume Correction | Automatic calculation per ISO 10780 & GBZ 159–2004 (at 25 °C, 101.325 kPa) |
| Brand | AMAE |
|---|---|
| Model | CQB300 |
| Type | Intrinsically Safe Personal Air Sampler for Hazardous Environments |
| Origin | Shenzhen, China |
| Flow Range | 10–300 mL/min |
| Flow Resolution | 1 mL/min |
| Explosion Protection | Certified for Class I and Class II hazardous locations |
| Compliance | GBZ 159-2004, GBZ/T 160 series, GBZ/T 300 series, GBZ 2.1-2019 |
| Power | Rechargeable high-capacity lithium battery |
| Sampling Modes | Manual, Timed, Volume-Controlled, Cyclic |
| Environmental Compensation | Integrated barometric pressure & ambient temperature sensing with automatic standard-condition (STP: 25 °C, 101.325 kPa) volume calculation |
| Data Handling | Onboard memory, USB data export, optional thermal printer support |
| Accessories | Anti-static shoulder strap, wall-mount charger, dual/quad sampler rack case, sorbent tube adapters |
| Brand | AMAE |
|---|---|
| Model | DS-30 |
| Sampling Flow Range | 3–30 L/min |
| Flow Accuracy | ±2% of reading |
| Operating Noise Level | <45 dB(A) |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation at 20 L/min) |
| Data Storage Capacity | 10,000 sampling records with timestamp, flow log, and event flags |
| Compliance | GBZ 159-2004, GBZ/T 192.1–192.2, GB/T 17061, GBZ/T 300, GBZ 2.1-2019 |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | EM-300 |
| Sampling Configuration | Single-Channel |
| Flow Range | 10–200 mL/min |
| Maximum Vacuum Pressure | >4.5 kPa |
| Flow Stability | <3% RSD |
| Flowmeter Accuracy | ±5% FS |
| Service Life at Max Load | >5,000 h |
| Continuous Operation | 40 h at 200 mL/min against 10 kPa backpressure |
| Compliance | Q/AMAE-2019, HJ 583–2010, JJG 956–2013, GB/T 17061–1997 |
| Brand | AMAE |
|---|---|
| Origin | Shenzhen, China |
| Model | EM-300E |
| Sampler Type | 24-Hour Temperature- and Flow-Controlled Dual-Channel Gas Sampler |
| Flow Range | 10–300 mL/min |
| Resolution | 1 mL/min |
| Maximum Vacuum Pressure | 30 kPa |
| Flow Stability | ≤2% |
| Flowmeter Accuracy | ≤3% |
| Service Life Under Max Load & Resistance | >5,000 hours |
| Continuous Operation Time at Max Flow & Load | 2–8 hours |
| Intrinsic Safety Certification | Yes (Explosion-Proof Rated) |
| Compliance | GBZ 159–2004, GBZ/T 160 series, GBZ/T 300 series, GBZ 2.1–2019 |
| Brand | AMAE |
|---|---|
| Model | EM-3040 |
| Type | Portable Flue Gas Analyzer |
| Measurement Principle | UV Differential Optical Absorption Spectroscopy (UV-DOAS) |
| Measurable Gases | SO₂, NO, O₂, CO, NO₂, CO₂ |
| Operating Temperature Range | -10 °C to 50 °C |
| Display | 8-inch TFT LCD, 800×600 resolution, 900 cd/m² brightness, 3-level adjustable backlight |
| Weight | ≈5 kg |
| Compliance | HJ/T 397–2007, JJG 968–2002, DB37/T 2641–2015, DB37/T 2704–2015, DB37/T 2705–2015, GB/T 16157–1996 |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | EM-3088-4.0 |
| Sampling Flow Rate | 0–110 L/min |
| Flow Accuracy | ±5% or better |
| Sample Type | Isokinetic particulate sampling + flue gas component analysis (O₂, SO₂, CO, NO, NO₂, H₂S, CO₂) |
| Compliance | Designed for fixed-source emission monitoring per Chinese EPA HJ/T 47–1999, HJ/T 48–1999, and compatible with ISO 16911-1:2013 principles |
| Power | Integrated rechargeable battery for field operation |
| Water Removal | Triple-stage condensate removal with auto-drain function |
| Data Output | Real-time parametric logging including stack temperature, static/dynamic pressure, atmospheric pressure, moisture content, flow velocity, and volumetric flow |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EM-3088S |
| Price Range | USD 16,500 – 20,500 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Sample Application | Isokinetic particulate sampling and real-time flue gas component analysis in exhaust ducts under industrial operating conditions |
| Sampling Flow Rate | 0–110 L/min |
| Flow Accuracy | ±5% or better |
| Flue Gas Velocity Range (Isokinetic Suction) | 1–50 m/s |
| Moisture Tolerance | Relative Humidity ≤95% RH |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | EM-500 |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 10–600 mL/min |
| Maximum Backpressure Capacity | 4.5 kPa |
| Flow Stability | <3% |
| Flowmeter Accuracy | ±5% |
| Rated Service Life at Max Flow & Load | 5,000 h |
| Continuous Operation Time at Max Flow & Load | 12 h |
| Operating Temperature Range | −10 °C to +50 °C |
| Net Weight | 400 g |
| Display | Backlit LCD with Real-Time Parameter Monitoring |
| Power Source | Rechargeable Lithium Battery (≥24 h runtime under typical conditions) |
| Calibration Support | Compatible with Primary Soap Film Flowmeter |
| Compliance | GB 50325–2001/2006, JJG 956–2013, GB/T 17061–1997 |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | EM-5000 |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Sampling System |
| Flow Range | 900–5100 mL/min |
| Maximum Vacuum Pressure | 4.5 kPa |
| Flow Stability | <3% RSD |
| Flowmeter Accuracy | ±5% FS |
| Rated Service Life at Max Flow & Backpressure | 5000 h |
| Continuous Operation Time at Max Flow & 5 kPa Backpressure | 12 h |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | EM-5000E |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 500–5650 mL/min |
| Flow Stability | ±2% |
| Flowmeter Accuracy | ±2.5% |
| Operational Lifetime at Max Flow & Backpressure | 40 h |
| Runtime at Max Flow & Backpressure | 40 h |
| Interface | USB Type-C (supports data export via USB flash drive, firmware updates, communication protocol expansion, and fast charging |
| Connectivity | Bluetooth 5.0, SparkLink (StarFlash), NFC |
| Calibration | On-device automatic calibration compatible with standard flow calibrators (e.g., dry calibrators, bubble meters, primary standards per ISO 13137) |
| Smart Controls | Programmable “Smart Key” (double-click/long-press configurable), voice activation (via integrated microphone and edge-based ASR engine), peer device cloning (“Fission Mode”) |
