Empowering Scientific Discovery

Geotech China Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandACS
OriginRussia
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelA1040 MIRA
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandACS
OriginItaly
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelA1040 MIRA 3D
Frequency Bandwidth10–100 kHz
Parallel DAQ Channels32
Maximum Penetration Depth3 m (concrete-dependent)
Maximum Coverage Area10 × 10 m
Frame Rate25 Hz (2D), 2 Hz (3D)
Battery LifeUp to 10 h per charge
Sensor Configuration4 × 8 A-DPC® array (expandable)
ComplianceT/CECS XXX-202X, JGJ/T 485-2019, DB32/T 3754-2020, DB34/T 5072-2017, DB37/T 5106-2018, DG/TJ 08-2252-2018, DB13(J)/T 8327-2019, DBJ/T-199-2020
Added to wishlistRemoved from wishlist 0
Add to compare
BrandACS
OriginItaly
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelA1040 MIRA 3D Pro
Frequency Bandwidth10–100 kHz
Parallel DAQ Channels64
Maximum Penetration Depth4 m (concrete-dependent)
Maximum Scanning Area10 × 10 m
Frame Rate12 Hz (2D), 0.3 Hz (3D)
Battery LifeUp to 10 h per charge
Sensor Configuration4 × 16 or 8 × 8 A-DPC® array (expandable)
ComplianceT/CECS XXX-202X, JGJ/T 485–2019, DB32/T 3754–2020, DB34/T 5072–2017, DB37/T 5106–2018, DG/TJ 08–2252–2018, DB13(J)/T 8327–2019, DBJ/T–199–2020
Added to wishlistRemoved from wishlist 0
Add to compare
BrandACS
OriginHong Kong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelA1052 MultiSONIC
Price RangeUSD 1–2 (Unit Price Indicative
Channels32-channel pulser-receiver array
ConnectivityIntegrated Wi-Fi interface (IEEE 802.11 b/g/n, 2.4 GHz)
Power SupplyRechargeable Li-ion battery (operational autonomy ≥ 6 h)
ExcitationBipolar pulse burst with user-defined frequency, half-cycle duration, and number of half-cycles
Compatible TransducersAll ACS dry-point contact ultrasonic transducers (e.g., A101x series, 20–500 kHz nominal bandwidth)
Encoding SupportGolay complementary sequence excitation (length up to 64 bits)
SoftwareMATHILDA32 (free demonstration version included)
Operating ModesPulse-echo, through-transmission, pitch-catch
ComplianceCE, RoHS, FCC Part 15 Subpart B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandControls (Europe)
OriginGermany
ModelPermeaTORR AC+
Power Supply24 Vdc / 3 Adc
Weight (pump + case)10 kg
Data Storage≥1000 test records (internal microSD)
InterfaceTouchscreen display + Bluetooth-enabled mobile remote control
Vacuum SourceIntegrated oil-free miniature vacuum pump
Hose LengthFixed-length flexible hose up to 5 m
ComplianceGB/T 50082–2024, SIA 261/1:2019, ASTM C1202, EN 12390-8, Cembureau O₂ permeability protocol
Added to wishlistRemoved from wishlist 0
Add to compare
BrandACS
OriginItaly
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelA1410 Pulsar
PriceUSD 6,800 (FOB Italy)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFTT
OriginUnited Kingdom
ModeliCone
ComplianceISO 5660-1 & -2, ASTM E1354, ASTM E1740, ASTM F1550, ASTM D5485, ASTM D6113, NFPA 271, NFPA 264, CAN/ULC-S135, BS 476-15, GB/T 16172
Heat Flux RangeUp to 100 kW/m²
Sample Size100 mm × 100 mm (max thickness 50 mm)
Mass Loss Resolution0.01 g
Exhaust Flow Rate24 L/s
Oxygen AnalysisParamagnetic or Zirconia-based O₂ sensor
Smoke ObscurationHe–Ne laser (0.5 mW), Si photodiode detector with ND filters (0.3 & 0.8)
Ignition Source10 kV spark igniter with auto-positioning and safety cutoff
Data AcquisitionSynchronized multi-channel, 100 Hz sampling rate
SoftwareConeCalc v6.x (Windows-based, multilingual UI)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFTT
OriginUnited Kingdom
ModelRadiant Panel Flame Spread Apparatus
Compliance StandardsASTM E162, ASTM D3675
Radiation Panel Dimensions12 in × 18 in (305 mm × 457 mm)
Panel MaterialPorous cement and cast iron
Ignition SystemElectronic spark igniter with auto-shutdown safety monitoring
Sample HolderStainless steel, calibrated at 3-inch (76 mm) intervals for flame front observation
Thermocouple ArrayEight calibrated stainless steel thermocouples integrated into exhaust duct
Surface Temperature MeasurementCalibrated high-temperature pyrometer with mounting fixture
Gas ControlPrecision methane flowmeter and adjustable gas mixture valve
Exhaust SystemRemovable-panel stainless steel ducting for maintenance access
Safety SystemsInterlocked gas shutoff valve and circuit-breaker activated by flame failure or overtemperature
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFTT
OriginUnited Kingdom
ModelNBS
ComplianceASTM E662, ASTM F814, ISO 5659-2, NFPA 258, BS 6401, GB/T 8323, IMO FTPC Part 2, NES 711
Chamber Dimensions914 mm × 914 mm × 610 mm (L×H×W)
Radiant Heat Flux Range10–50 kW/m² (calibrated at 25 kW/m² ±1 kW/m²)
Optical System6.5 V Tungsten Lamp + S-4 Spectral Response Photomultiplier Tube (dark current <10⁻⁹ A)
Light Beam Transmission Accuracy0.01%
Optical Density Resolution0.01
Mass Loss Measurement Accuracy±0.1%
Timer Resolution0.1 s
Cone Heater Power2600 W
ThermocouplesDual K-type armored (Cu/Alumel)
Heat Flux MeterThermopile-based, calibrated to ±1 kW/m² at 25 & 50 kW/m²
IgnitionHorizontal single-flame burner (30 mm ±5 mm), spark-ignited without chamber opening
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFTT
OriginUnited Kingdom
ModelOxygen Bomb Calorimeter
Standards ComplianceISO 1716, ISO 1928, ASTM D240, ASTM D4809, ASTM D5468, ASTM D5865, ASTM E711
Application ScopeGross Calorific Value (GCV) determination of solid, liquid, and heterogeneous fuels and combustible materials
ConfigurationIncludes main calorimeter unit, high-pressure oxygen bomb assembly, oxygen charging station, calibration accessories (benzoic acid standard, ignition wire, crucibles), and installation kit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGREATEK
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelGT-E220
PriceUSD 32,500 (FOB Guangdong)
Imaging MethodOptical Rigid Endoscope
Camera Resolution640 × 480 (0.31 MP effective, 720p-equivalent progressive scan output)
Display6.5-inch capacitive touchscreen (1280 × 720 IPS LCD)
Measurement ModesPoint-to-Point, Point-to-Line, Point-to-Plane, Curvilinear Distance
Real-time 3D ReconstructionBinocular stereo photogrammetry with sub-pixel disparity matching
BatteryRemovable 7800 mAh Li-ion pack (typ. 4.5 h continuous operation)
Data ExportUSB 2.0 mass storage mode, FAT32-formatted U disk support
ComplianceT/CECS 683–2020, JGJ/T 485–2019, DB37/T 5106–2018, DG/TJ 08–2252–2018, DB13(J)/T 8327–2019, DB32/T 3754–2020, DBJ/T–199–2020, DB22/T 5037–2020, DBJ52/T105–2021
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFTT
OriginUnited Kingdom
ModelFRP
Standards ComplianceEN ISO 9239-1, ASTM E648, ASTM E970, NFPA 253, GB/T 11785
Radiation SourceGas-fired flat-panel radiator inclined at 30°
Radiant Heat Flux Range1.1–10.9 kW/m² (extendable to 25.0 kW/m²)
Critical Radiant Flux Resolution0.1 kW/m²
Sample OrientationHorizontal
IgnitionPilot burner with stainless steel nozzle
Smoke MeasurementDIN 50055-compliant optical smoke density system mounted on exhaust duct
Dimensions (W×D×H)1900 × 750 × 1900 mm
ConstructionStainless steel hood, calibrated angular positioning plate, dual-access observation door with sliding platform
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFTT
OriginUnited Kingdom
ModelABD0031
ApplicationIntegrated with NBS-type smoke density chamber for aircraft cabin material qualification
Core ComponentsVacuum chamber, vacuum pump, manual metering pump, gas analysis detector tubes
Compliance ContextAirbus ABD0031 specification, ASTM E662, ISO 5659-2, FAA AC 20-135, EN 45545-2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandForce
OriginDenmark
ModelERE 20
TypeEmbedded Half-Cell Reference Electrode
Electrode MaterialManganese Dioxide (MnO₂)
Electrolyte pH~13.5
HousingStainless Steel (AISI 316)
Ionic MembraneCementitious Mortar
Input Impedance Requirement>100 MΩ
ComplianceEN 12696:2016, ASTM C876, ISO 15663-2
InstallationEmbeddable in Fresh or Existing Concrete
Output InterfaceStandard BNC or Screw-Terminal Voltage Output
Operating Temperature Range−10 °C to +60 °C
Long-Term Drift< ±2 mV/year (typical, under stable alkaline conditions)