- All
- Favorite
- Popular
- Most rated
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | CIMPS-Pro Zennium |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A, ±10 A |
| Current Accuracy | 0.02% of reading |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V, ±20 V |
| AC Impedance Frequency Range | 10 µHz – 8 MHz |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium XC |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | 0.04% |
| Potential Accuracy | 100 µV |
| Potentiostatic Range | ±14 V |
| EIS Frequency Range | 10 µHz – 5 MHz |
| ADC Resolution | 32-bit |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Input Impedance | 10 TΩ (optional Hi-Z: 1000 TΩ) |
| EIS Accuracy | ±0.2% (100 mΩ–10 MΩ), ±2% (1 mΩ–100 mΩ or 10 MΩ–10 GΩ) |
| AC Perturbation Amplitude | 0–6 V (18-bit resolution) |
| Grounding Modes | Grounded & Switchable Floating Ground |
| IR Compensation | Real-time, automatic, 0–10 MΩ range |
| Bandwidth | 6 MHz |
| CV Scan Rate | up to 10,000 V/s (with ADF high-speed option) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium X |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±4 A |
| Current Accuracy | ±0.02% of reading + ±0.01% of full scale (1 µA–100 mA), ±0.2% of reading + ±0.1% of full scale (100 mA–3 A), ±0.2% of reading + ±0.1% of full scale (10 nA–1 µA) |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| Compliance Voltage | ±32 V |
| EIS Frequency Range | 10 µHz–12 MHz |
| Frequency Accuracy | 0.0025% |
| Frequency Resolution | 10,000 steps/decade |
| Input Impedance | >10 TΩ |
| Voltage Resolution | 3 nV |
| Current Resolution | ±5 aA (32-bit DAC/ADC) |
| Bandwidth | 15 MHz |
| IR Compensation | Real-time, automatic EIS-based compensation |
| Grounding Mode | Switchable floating/grounded configuration |
| ADC/DAC Resolution | 32-bit HDP (High Dynamic Precision) architecture |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | ZenniumPro |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A |
| Current Resolution | ±5 aA |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32-bit |
| Bandwidth | 10 MHz |
| Voltage Resolution | 3 nV |
| IR Compensation | Real-time, automatic |
| Grounding Modes | Switchable floating/grounded |
| Small-Signal Rise Time | 150 ns – 200 µs (5 steps) |
| Impedance Accuracy | 1 mΩ–10 GΩ (±2%), 100 mΩ–10 MΩ (±0.2%) in POT mode |
| Software | Thales XT + Zahner Analysis (EIS fitting, CIMPS, Z-HIT, NFRA) |
| Brand | Admiral |
|---|---|
| Origin | USA |
| Model | Squidstat Prime |
| Instrument Type | Benchtop Multi-Channel Electrochemical Workstation |
| Number of Channels | 4 Independent Channels |
| Current Range per Channel | ±250 mA |
| Current Resolution | 750 fA (0.003% of range) |
| Current Accuracy | 0.1% of full scale, down to 10 nA |
| Potential Range | ±10 V |
| Potential Accuracy | ±1 mV (0.1% of range) |
| Potentiostatic/Galvanostatic/ZRA Modes | Yes |
| Input Impedance | 10 TΩ |
| ADC Resolution | 16-bit |
| Sampling Rate | 40 kS/s |
| Onboard Memory | 16 GB |
| Electrode Configurations Supported | 2-, 3-, 4-, and 5-electrode |
| Standard Cable Length | 90 cm |
| AC Impedance Frequency Range | 10 µHz – 1 MHz (typical, dependent on cell configuration) |
| Compliance | ASTM G5, G59, G102 |
| Brand | Admiral |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Squidstat Ace |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | 1 |
| Current Range | ±1 A |
| Current Resolution | 3 pA (0.003% of full scale) |
| Potential Range | ±10 V |
| Potential Resolution | 300 µV |
| Time Resolution | 10 µs |
| AC Impedance Capability | Not Supported |
| Supported DC Techniques | Cyclic Voltammetry, Linear Sweep Voltammetry, Open Circuit Potential, Chronoamperometry/Chronocoulometry, Linear Sweep Chronoamperometry, Chronopotentiometry, Differential Pulse Voltammetry, Normal Pulse Voltammetry, Square Wave Voltammetry, Relaxation Voltammetry, Staircase Voltammetry, Tafel Scan, Pulse Plating, Stripping Voltammetry |
| Supported Battery Testing Modes | Galvanostatic Charge/Discharge, Potentiostatic Charge/Discharge, Constant Resistance Discharge, Constant Power Discharge, High-Power Discharge, Capacity-Limited Cycling, Steady-State I–V Profiling |
| Brand | Admiral |
|---|---|
| Origin | USA |
| Model | Squidstat Plus |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 A |
| Current Accuracy | ±1 A |
| Potential Accuracy | ±300 µV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Current Resolution | 3 pA (0.003% of full scale) |
| Voltage Resolution | 300 µV |
| Data Storage | Internal 16 GB Flash Memory |
| Output Format | CSV (up to millions of data points) |
Show next