Empowering Scientific Discovery

Guangzhou Aice Intelligent Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
OriginShanghai, China
ModelDO300(1.5m)
Instrument TypePortable
Measurement PrincipleElectrochemical Clark-type Polarographic Probe
Range0–20.00 mg/L
Accuracy±0.30 mg/L
Repeatability0.1%
Detection Limit0.10 mg/L
Temperature CompensationAutomatic (0–45 °C)
Salinity CompensationAutomatic (0–45 ppt)
Barometric Pressure CompensationManual (80–105 kPa)
Response Time30 s (90% at 25 °C)
Display68 × 53 mm LCD with white backlight and time stamp
Data Storage500 sets (manual & auto), GLP-compliant
IP RatingIP57
InterfaceUSB
Operating Temperature−10 to 110 °C
ResolutionDO: 0.01/0.1 mg/L
Saturation0.1/1 %
Temp0.1 °C
Residual Current≤0.10 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
OriginShanghai, China
ModelPI5100-Ca
Instrument TypeBenchtop
Ion Measurement Range0.00–14.00 pX
Detection Limit0.01 ppm
Response Time1 s
Measurement Accuracy±0.01 pX (for monovalent ions) / ±0.02 pX (for divalent ions)
Temperature Range−10 to 110 °C
Resolution0.01 pX, 0.01 mol/L, 0.01 mg/L, 0.01 ppm
pH Range−2.000–19.999 pH
pH Accuracy±0.002 pH
mV Range−1999.9 to +1999.9 mV
mV Accuracy±0.03% FS
Temperature Accuracy±0.4 °C
Data Storage Capacity1000 sets
InterfaceUSB
IP RatingIP54
Display90 × 68 mm LCD with white backlight and real-time clock
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
ModelDO410
OriginShanghai, China
Instrument TypeLaboratory Benchtop Meter
Measurement PrinciplePolarographic Electrochemical Probe
Dissolved Oxygen Range0–20.00 mg/L (ppm)
Saturation Range0.0–200.0 %
Temperature Range−10 to 110 °C
Accuracy (DO)±0.30 mg/L
Accuracy (Temp)±0.4 °C
Resolution (DO)0.01/0.1 mg/L
Resolution (Saturation)0.1/1 %
Resolution (Temp)0.1 °C
Repeatability0.1 %
Detection Limit0.10 mg/L
Response Time30 s (90 % at 25 °C)
Residual Current Equivalent0.10 mg/L
Temperature CompensationAutomatic (0–45 °C)
Salinity CompensationAutomatic (0–45 ppt)
Atmospheric Pressure CompensationAutomatic (80–105 kPa)
Data Storage500 sets (manual & auto)
Display90 × 68 mm LCD with white backlight and time stamp
IP RatingIP54
InterfaceUSB port with included software and cable
Power9 V AC adapter
ElectrodeIntegrated temperature- and salinity-compensated polarographic probe with replaceable membrane cap and internal electrolyte
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
OriginShanghai, China
ModelPI5100-K
Instrument TypeBenchtop Multi-Ion Analyzer
Measurement Range0.00–14.00 pX
Detection Limit0.01 ppm
Response Time1 s
Accuracy±0.01 pX (for monovalent ions)
Temperature Range−10 to 110 °C
Resolution0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm
pH Range−2.000 to 19.999 pH
mV Range−1999.9 to +1999.9 mV
Temperature CompensationAutomatic/manual (0–60.0 °C for ion mode
Data Storage1000 sets (manual & auto)
InterfaceUSB
Display90 × 68 mm LCD with white backlight and real-time clock
Protection RatingIP54
ComplianceGLP-compliant data management, ASTM D1129, ISO 7888, USP <791>, FDA 21 CFR Part 11-ready audit trail support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
OriginShanghai, China
ModelPD5200
Instrument TypeLaboratory
Measurement PrincipleElectrochemical Clark-type Polarographic Probe
Dissolved Oxygen Range0–20.00 mg/L
Accuracy (DO)±0.30 mg/L
Repeatability0.1%
Detection Limit (DO)0.10 mg/L
pH Range−2.000–19.999
pH Accuracy±0.002 pH
mV Range±1999.9 mV
mV Accuracy±0.03% FS
Temperature Range−10–100 °C
Temp Accuracy±0.4 °C
Response Time (DO)30 s (90% at 25 °C)
Residual Current0.10 mg/L
DO ElectrodeMembrane-covered polarographic sensor with integrated temperature compensation and salinity/pressure compensation
pH CalibrationUp to 5-point auto-calibration with NIST, USA, CH, and custom buffer sets (15 total)
Data Storage1000 entries (manual/auto), GLP-compliant
ConnectivityUSB interface
IP RatingIP54
Display90 × 68 mm LCD with white backlight and time stamp
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
OriginShanghai, China
ModelMP6500
Instrument TypeLaboratory Benchtop
Measurement PrincipleElectrochemical Clark-type Polarographic Sensor
DO Range0–20.00 mg/L
DO Accuracy±0.30 mg/L
DO Repeatability0.1%
Detection Limit0.10 mg/L
Temperature Compensation0–45 °C (auto), Salinity Compensation: 0–45 ppt (auto), Barometric Pressure Compensation: 80–105 kPa (manual)
Data Storage1000 sets (manual & auto)
InterfaceUSB
IP RatingIP54
Display90 × 68 mm LCD with white backlight and real-time clock
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
OriginShanghai, China
ModelPD320
Instrument TypePortable
Measurement PrincipleElectrochemical Clark-type Polarographic Probe
Dissolved Oxygen Range0.0–20.0 mg/L
Accuracy (DO)±0.30 mg/L
Repeatability0.1%
Detection Limit (DO)0.10 mg/L
pH Range−2.00–19.99 pH
mV Range±1999 mV
Temperature Range−10–110 °C
DO Saturation Range0.0–200.0 %
pH Resolution0.01/0.1 pH
mV Resolution1 mV
DO Saturation Resolution0.1/1 %
Temperature Resolution0.1 °C
pH Accuracy±0.01 pH
mV Accuracy±0.1% FS
Temperature Accuracy±0.4 °C
Response Time (DO)30 s (90% at 25 °C)
Residual Current0.10 mg/L
IP RatingIP57
Data Storage1000 sets (manual & auto)
InterfaceUSB
ComplianceGLP-compliant data management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
OriginShanghai, China
ModelPI5100-F
Instrument TypeBenchtop Ion Analyzer
Ion MeasuredFluoride (F⁻)
Measurement Range0.00–14.00 pX
Detection Limit0.01 ppm
Response Time≤1 s
Accuracy±0.01 pX (for monovalent ions)
Temperature Range−10 to 110 °C
Resolution0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm
pH Range−2.000 to 19.999 pH
mV Range−1999.9 to +1999.9 mV
Temperature CompensationAutomatic/manual (0–60.0 °C for ion mode
Data Storage1000 sets (manual & auto)
InterfaceUSB
Display90 × 68 mm LCD with white backlight and real-time clock
IP RatingIP54
ComplianceGLP-compliant data management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
ModelPI5100-CL
TypeBenchtop Ion Concentration Meter
Measurement Range0.00–14.00 pX
Detection Limit0.01 ppm
Response Time1 s
Accuracy±0.01 pX (for monovalent ions)
Temperature Range−10 to 110 °C
Resolution0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm
pH Range−2.000–19.999 pH
mV Range−1999.9 to +1999.9 mV
Temperature CompensationAutomatic/manual (0–60.0 °C for ion mode
Data Storage1000 sets (manual & auto)
InterfaceUSB
Display90 × 68 mm LCD with white backlight and real-time clock
Protection RatingIP54
ComplianceGLP-compliant data management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
OriginShanghai, China
ModelPI5100-I
Instrument TypeBenchtop Multi-Ion Analyzer
Measurement Range0.00–14.00 pX
Detection Limit0.01 ppm
Response Time1 s
Accuracy±0.01 pX (for monovalent ions)
Temperature Range−10 to 110 °C
Resolution0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm
pH Range−2.000 to 19.999 pH
mV Range−1999.9 to +1999.9 mV
Temperature CompensationAutomatic/manual (0–60.0 °C for ion mode
Data Storage1000 sets (manual & auto)
InterfaceUSB
Display90 × 68 mm LCD with white backlight and real-time clock
IP RatingIP54
ComplianceGLP-compliant data management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
OriginShanghai, China
ModelPI5100-Na
Instrument TypeBenchtop Sodium Ion Analyzer
Measurement Range0.00–14.00 pX
Detection Limit0.01 ppm
Response Time≤1 s
Accuracy±0.01 pX (for monovalent ions)
Temperature Range−10 to 110 °C
Resolution0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm
pH Range−2.000 to 19.999 pH
mV Range−1999.9 to +1999.9 mV
Temperature CompensationAutomatic/manual (0–60.0 °C for ion mode
Data Storage1000 sets (manual & auto)
InterfaceUSB
Display90 × 68 mm LCD with white backlight and real-time clock
IP RatingIP54
ComplianceGLP-compliant data management, supports ASTM D1129, ISO 10523, and USP <791> for ion-selective electrode methodology
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
OriginShanghai, China
ModelPI5100-Br
Instrument TypeBenchtop Multi-Ion Analyzer
Measurement Range0.00–14.00 pX
Detection Limit0.01 ppm
Response Time1 s
Accuracy±0.01 pX (for monovalent ions)
Temperature Range−10 to 110 °C
Resolution0.01 pX / 0.01 mol/L / 0.01 mg/L / 0.01 ppm
pH Range−2.000 to 19.999 pH
mV Range−1999.9 to +1999.9 mV
Temperature CompensationAutomatic/manual (0–60.0 °C for ion mode
Data Storage1000 sets (manual & auto)
InterfaceUSB
Display90 × 68 mm LCD with white backlight and real-time clock
IP RatingIP54
ComplianceGLP-compliant data management
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
OriginShanghai, China
ModelMP3500
Instrument TypePortable
Measurement PrinciplePolarographic Electrochemical Probe
DO Range0–20.00 mg/L
Accuracy (DO)±0.30 mg/L
Repeatability0.1%
Detection Limit0.01 mg/L
DO Temperature Compensation0–45 °C
DO Salinity Compensation0–45 ppt
Barometric Pressure Compensation80–105 kPa
IP RatingIP57
Data Storage1000 sets (GLP-compliant)
Display68 × 53 mm LCD with white backlight
InterfaceUSB
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAlalis
OriginShanghai, China
ModelDO300(5m)
Instrument TypePortable
Measurement PrincipleElectrochemical Clark-type Polarographic Sensor
Range0–20.00 mg/L
Accuracy±0.30 mg/L
Repeatability0.1%
Detection Limit0.10 mg/L
Temperature CompensationAutomatic (0–45 °C)
Salinity CompensationAutomatic (0–45 ppt)
Barometric Pressure CompensationManual (80–105 kPa)
Response Time30 s (90% at 25 °C)
Residual Current Equivalent0.10 mg/L
Data Storage500 sets (manual & auto)
Display68 × 53 mm LCD with white backlight and time stamp
IP RatingIP57
InterfaceUSB
GLP ComplianceYes
Temperature Range (sensor)−10 to 110 °C
ResolutionDO: 0.01/0.1 mg/L
Saturation0.1/1 %
Temp0.1 °C
Basic Error (Temp)±0.4 °C
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0