Empowering Scientific Discovery

Guining (Shanghai) Laboratory Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelASA-03RXD
Imaging PrincipleCCD-based 30° parallel-light profilometry
Sample TypeSilicone replica
Quantitative OutputWrinkle count, volume (triangular cross-section model), depth, width, area ratio, texture parameters (Rz, Rt), 3D surface visualization
ComplianceJSCA Guideline for Evaluation of Anti-Wrinkle Products
Software PlatformWindows 10 native application with calibration, edge enhancement, and XY/depth conversion modules
Optional ModulesSebum measurement kit (ASS-001 SEBU patch + absorbance analysis software)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelAS-GP1
Measurement PrincipleDual-finger-type quasi-static compression with real-time viscoelastic force feedback
Sensor TypeLightweight, bidirectional tactile probes with adjustable clamping displacement and dwell time
Output ParametersMaximum Stress (kPa), Skin Hardness Index, Elastic Recoil Ratio (%), Viscoelastic Relaxation Time Constant (s), Collagen Aging Index (unitless derived metric), Initial Rebound Velocity (mm/s), Sagging Index (normalized strain recovery deficit)
ComplianceDesigned for GLP-aligned dermatological research workflows
Software InterfacePC-based acquisition with waveform visualization, timestamped data export (CSV, PNG), and multi-point protocol storage
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelAS-TZ1
Measurement PrincipleLow-frequency AC impedance
Impedance Range0.5–99 kΩ
Phase Angle Range0–90°
Repeatability±2% (0.1–10 kΩ), ±1% (10–99 kΩ)
Excitation Voltage5 V DC
Test Frequency12 Hz
ElectrodesAg/AgCl (donor side), Ag (receiver side)
Display65 × 15 mm LCD
Dimensions190 × 60 × 200 mm
Power Supply6 V DC (battery-operated)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelASA-MX100
Measurement PrincipleConductivity-based Corneal Hydration & Transepidermal Electrical Resistance (TEER)
Probe TypesC3D-MX (3D skin models), R2-MX (scalp), T4-MX (nail)
Measurement Time5 s per reading
Electrode ConfigurationSeparated excitation/detection electrodes
Output InterfaceRS-232 digital port
CalibrationFully digital one-button calibration
ComplianceDesigned for GLP-compliant dermatological research and cosmetic efficacy testing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASE
OriginJapan
ModelLHT-04
Measurement PrincipleVentilated Capsule Method
Measurement Range0.00–3.00 mg/cm²/min (at 30 °C, 40 % RH)
Accuracy±10 %
Response Time1 s
Measurement Area1 cm²
Channel Count1
Probe Length0.9 m (standard), up to 1.2 m (optional)
Data Logging Duration4 h
Power Supply2 × AA batteries
Operating Temperature15–35 °C
Operating Humidity40–60 % RH
Dimensions (W×H×D)76 × 35 × 135 mm
Weight350 g
ComplianceDesigned for ISO 9241-305 (human thermal comfort), ASTM E1980 (sweat rate in physiological testing), and GLP-aligned data integrity workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelAS-VT100RS
Measurement PrincipleClosed-chamber dynamic humidity gradient analysis
TEWL Range0–300 g/m²/h
Resolution0.1 g/m²/h
Measurement Time5–14 s
Probe Aperture Options6, 8, 10, or 12 mm (DIP-switch configurable)
Dimensions165 × 70 × 28 mm
Weight200 g
Power SupplyAC adapter or AA batteries
Environmental MonitoringIntegrated temperature & relative humidity sensors
Data OutputRS-232 serial interface
Sample TypesHuman skin (in vivo), excised animal skin (rat, pig, rabbit), 3D reconstructed human epidermis (RHE), and cultured skin models
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelASP-02
Measurement Range0–9 pH
Resolution0.1 pH
Accuracy±0.2 pH
Response Time≤10 s
CalibrationTwo-point with pH 4.0 and pH 7.0 standard buffers
Operating Temperature0–50 °C
Storage Environment5–50 °C, 5–85% RH (non-condensing)
Power Supply2 × AA alkaline batteries
Main Unit Dimensions122 × 80 × 33.5 mm (H×W×D)
Main Unit Weight~200 g
Electrode Dimensions135 mm length × φ12 mm diameter
Cable Length1 m
Electrode Weight~60 g
Sample InterfaceFlat-surface combination pH electrode for direct skin contact
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0