| Brand | LANTIAN |
|---|---|
| Model | AOX-C |
| Origin | Zhejiang, China |
| Manufacturer | LANTIAN Instrument Co., Ltd. |
| Application | AOX determination in water and solid matrices per HJ/T 83–2001, ISO 9562:1989, and GB/T 15959–1995 |
| Detection Method | High-temperature catalytic combustion followed by alkaline absorption and ion chromatographic quantification of F⁻, Cl⁻, Br⁻ |
| Sample Types | Drinking water, surface water, groundwater, wastewater, effluent, seawater, pulp mill discharge, soil, sediment, sludge, and waste oils |
| System Configuration | Integrated furnace with built-in scrubbing system, quartz combustion tube, dual-zone oxygen supply, nitrogen-driven adsorption module, standardized absorption train, and IC-compatible sample preparation workflow |
| Compliance | Designed to support GLP-compliant AOX testing workflows |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-WK-S |
| Detection Principle | Microcoulometric Titration after High-Temperature Combustion |
| Compliance | HJ 1214–2021 (China National Standard) |
| Maximum Generator Current | ±2 mA |
| Amplifier Output Voltage | ±30 V |
| Bias Voltage Range | 0–500 mV (continuously adjustable) |
| Detection Limit | 0.007 µg/L (at 100 mL sample volume) |
| Optimal Measurement Range (as Cl) | 0.02–2 mg/kg |
| Precision | ≤10% RSD (for samples ≤2 mg/L) |
| Activated Carbon Loading | 50 mg ±5 mg |
| Combustion Temperature Range | 500–1100 °C (±1 °C accuracy) |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Rated Power | 3000 W |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-WK-S |
| Compliance Standard | HJ 1214–2021 (PRC National Ecological and Environmental Standard) |
| Generator Current Range | ±2 mA |
| Amplifier Output Voltage | ±30 V |
| Bias Voltage Adjustment Range | 0–500 mV (continuously adjustable) |
| Detection Limit | 0.007 µg/L (at 100 mL sample volume) |
| Measurement Range (as Cl) | 0.02–2 mg/kg |
| Accuracy | ±1 µg Cl |
| Repeatability | ≤10% RSD (for samples ≤2 mg/L) |
| Activated Carbon Dosage | 50 mg ±5 mg |
| Combustion Temperature Control Range | 500–1100 °C |
| Stability | ±1 °C |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Rated Power | 3000 W |
| Brand | LANTIAN |
|---|---|
| Model | AOX-C |
| Detection Principle | High-Temperature Combustion Coupled with Ion Chromatography |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Combustion Temperature | Up to 1150 °C |
| Sample Introduction | Nitrogen-Pressurized Column Adsorption |
| Sample Mass Range | 5–1000 mg |
| Detection Range | 0.8–1000 µg/L (as Cl⁻ equivalent) |
| Analysis Time (instrumental) | 3–10 min per sample |
| Carrier Gas | O₂ ≥99.6% (recommended ≥99.999%) |
| Accessories Included | Integrated combustion furnace, quartz combustion tube, dual sample boats, quartz push rod, rubber end caps, adsorption column assembly (×2), 1.27 m silicone tubing (OD 15 mm), 5 scrubbing bottles, 2 absorption bottles, 2 absorption tubes, mounting fixtures,纱布,胶布,扎线 |
| Software Option | Real-time instrument control and quantitative data processing module (optional) |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-C |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Detection Method | High-Temperature Combustion Coupled with Ion Chromatography (IC) |
| Measurable Species | AOX (as Cl), AOCl, AOF, AOBr |
| Sample Matrices | Drinking water, surface water, groundwater, wastewater, effluent, seawater, pulp mill discharge, soil, sediment, sludge, and waste oils |
| System Configuration | Integrated furnace with built-in gas scrubbing, dual-zone combustion tube, nitrogen pressurized adsorption unit, alkaline absorption train, and IC-ready halide quantification |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX- Organic Halogen Combustion Furnace |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995, GB 8978–1996, GB 3544–2008 |
| Sample Throughput | Up to 24 samples per batch (standard configuration) |
| Combustion Temperature Range | Ambient to 1100 °C (programmable, ±2 °C stability) |
| Gas Supply | Dual-gas system (N₂ for adsorption, O₂ for combustion) |
| Tube Material | High-purity quartz combustion tube (OD 15 mm, length 600 mm) |
| Integrated Scrubbing System | Five-stage acid/alkali wash bottles + dual absorption traps |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | AOX-C |
| Compliance | HJ/T 83–2001, ISO 9562:1989, GB/T 15959–1995 |
| Detection Method | Ion Chromatography (IC) of Inorganic Halides (Cl⁻, F⁻, Br⁻) after High-Temperature Combustion |
| Sample Matrix | Water (drinking, surface, groundwater, wastewater, seawater, treated effluent), sludge, sediment, soil, and waste oils |
| Key Components | Integrated furnace with built-in scrubbing system, quartz combustion tube, dual-zone oxygen supply, nitrogen-pressurized adsorption module, IC-compatible absorption train |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-WK-S |
| Compliance Standard | HJ 1214–2021 |
| Detection Principle | Microcoulometric Titration |
| Max Generator Current | ±2 mA |
| Amplifier Output Voltage | ±30 V |
| Bias Voltage Range | 0–500 mV (continuously adjustable) |
| Detection Limit | 0.007 mg/L (at 100 mL sample volume) |
| Optimal Measurement Range (as Cl) | 0.02–2 mg/kg |
| Accuracy | ≤10% relative deviation (at 1 µg Cl) |
| Repeatability | ≤10% RSD (for samples ≤2 mg/L) |
| Activated Carbon Dosage | 50 mg ±5 mg |
| Combustion Temperature Range | 500–1100 °C (±1 °C control accuracy) |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Rated Power | 3000 W |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AOX-WK-3 Microcoulometric Halogen Analyzer |
| Detection Principle | Microcoulometric Titration after High-Temperature Combustion (900–1100 °C) |
| Applicable Standards | GB/T 34845–2017, GB/T 22904–2008, GB/T 35613–2017, GB/T 39084–2020, GB/T 35611–2017, GB/T 41533–2022 |
| Detection Target | Adsorbable Organic Halogens (AOX), expressed as Cl⁻ |
| Detection Limit | 2 mg/kg |
| Quantification Range | 0.5–5 mg/kg (Cl) |
| Precision | ±1 µg Cl |
| Repeatability | ≤10% RSD at ≤2 mg/L sample concentration |
| Combustion Temperature Control | 500–1100 °C, ±1 °C accuracy |
| Generator Current Range | ±2 mA |
| Amplifier Output Voltage | ±30 V |
| Bias Voltage Adjustment | 0–500 mV, continuously adjustable |
| Sample Introduction | 50 mg ±5 mg activated carbon cartridge |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Rated Power | 3000 W |
| Interface | RS-232 (DB9) |
| Software Platform | Windows-based proprietary AOX analysis suite with real-time parameter monitoring, data logging, audit trail, and report generation (PDF/CSV export) |
| Brand | LANTIAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | AOX-C Ion Chromatography-Based AOX Analyzer |
| Price | USD 4,200 (FOB Zhejiang) |