- All
- Favorite
- Popular
- Most rated
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Model | JTSQ-50A |
| Capacity | 50 L |
| Temperature Control Range | RT+5°C to 60°C |
| Temperature Uniformity | ±0.3°C |
| Humidity Range | 35% ±5% RH (natural evaporation) |
| CO₂ Control Range | 0–20.0% (IR sensor, ±0.2% accuracy) |
| O₂ Control Range | 1.0–19.0% (hypoxic) or 23.0–50.0% (hyperoxic), up to 90.0% optional |
| O₂ Sensor | Imported zirconia |
| CO₂ Sensor | Imported NDIR infrared |
| Temperature Sensor | PT100 |
| Control System | PLC-based with 4.3″ capacitive touchscreen |
| Sterilization | UV lamp (optional 90°C moist-heat or 180°C dry-heat) |
| Heating Method | Air-jacketed |
| Internal Dimensions (W×D×H) | 340 × 340 × 450 mm |
| Standard Shelving | 2 stainless steel shelves |
| Power Consumption | 250 VA (±10%) |
| Brand | JTONE |
|---|---|
| Origin | Anhui, China |
| Model | HH.CP-TW |
| Capacity | 160 L |
| Temperature Range | RT+5°C to 50°C |
| Temperature Uniformity | ±0.3°C |
| Refrigerant | Eco-friendly non-CFC |
| Construction | Cold-rolled steel exterior with electrostatic powder coating |
| Airflow System | Vertical laminar airflow with forced convection circulation |
| CO₂ Control | Dual-stage infrared (IR) sensor-based regulation (5% setpoint typical) |
| Humidity Control | Passive water-jacket-assisted humidification (95% RH typical at 37°C) |
| Safety Features | Independent over-temperature cutoff, UV sterilization lamp, door-temperature compensation, microbial inlet filter (0.2 µm), optional CO₂ pressure regulator |
| Compliance | Designed to support GLP-compliant cell culture workflows |
| Software Interface | LCD microprocessor controller with real-time display of temperature, CO₂ concentration, and elapsed time |
Show next