| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 1000 |
| Spotting Method | Non-contact piezoelectric inkjet |
| Spot Volume Range | picoliter to nanoliter (pL–nL) |
| Spotting Speed | 711 spots per second |
| Substrate Capacity | 6 × SBS-compliant microtiter plates or 1,000 standard microscope slides |
| Repeatability (CV) | < 5% |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO 13485 and ASTM E2539-22 reference practices for microarray fabrication |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 25 |
| Spotting Method | Non-contact piezoelectric inkjet |
| Number of Parallel Nozzles | 128 |
| Spotting Speed | 711 spots per second |
| Substrate Capacity | 1 × SBS-standard microplate or 25 × standard microscope slides (76 × 26 mm) |
| Spot-to-Spot Reproducibility | CV < 5% |
| Environmental Control | Integrated humidity and temperature regulation with evaporation suppression |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 100 |
| Spotting Method | Non-contact piezoelectric inkjet |
| Spot Volume Range | picoliter to nanoliter (pL–nL) |
| Spotting Speed | 711 spots per second |
| Substrate Capacity | 6 × SBS-format microtiter plates or 100 standard microscope slides |
| Repeatability (CV) | < 5% |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO 13485 and ASTM E2519-22 reference practices for microarray fabrication |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 100-S |
| Spotting Method | Non-contact piezoelectric inkjet |
| Spotting Speed | 711 spots/second |
| Substrate Capacity | 48 × SBS-format microplates or 100 × standard microscope slides (76 × 26 mm) |
| Spot-to-spot Precision | CV < 5% |
| Dispense Volume Range | picoliter to nanoliter |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO 13485 and ASTM E2578-07 (Standard Guide for Microarray Processing) |
| Brand | M2 Automation |
|---|---|
| Origin | Germany |
| Model | iTWO-300P |
| Spotting Type | Non-contact piezoelectric dispensing |
| Spot Volume Range | 30 pL to 1 µL |
| Spotting Speed | Up to 1,000 droplets/sec |
| Substrate Capacity | Standard microscope slides, 96-/384-/1536-well plates, films, discs, microfluidic chips |
| Repeatability | ±5 µm |
| Minimum Feature Size | ≤1 µm |
| Maximum Stage Velocity | 75 cm/s |
| CV (Coefficient of Variation) | <2% |
| Compatible Spotting Modules | Piezo-based pL dispensers, M2MD nL dispensers, solenoid valves, multi-channel contact pins |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 1000-S |
| Spotting Method | Non-contact piezoelectric inkjet |
| Spot Volume Range | picoliter to nanoliter (pL–nL) |
| Spotting Speed | 711 spots per second |
| Substrate Capacity | 48 SBS-format microplates or 1,000 standard microscope slides |
| Positional Reproducibility | CV < 5% |
| Compliance | CE-marked, ISO 13485–compatible workflow design |
| Brand | M2 Automation |
|---|---|
| Origin | Germany |
| Model | iONE-600 |
| Spotting Technology | Non-contact piezoelectric dispensing |
| Maximum Spotting Rate | 1000 spots/sec |
| Spot Volume Range | 30 pL to 1 µL |
| Positioning Repeatability | ±3 µm |
| Maximum Stage Speed | 100 cm/s |
| Slide/Plate Capacity | 80 standard microscope slides (75 × 25 mm) |
| Spotting Precision (CV) | < 2% |
| Integrated Bubble Removal & Filtration | Yes |
| Onboard Quality Control Cameras | Top-view and droplet-view imaging |
| Environmental Control | Humidity and temperature stabilization module available |
| Brand | INNOPSYS |
|---|---|
| Origin | Germany |
| Model | InnoQuant |
| Laser Wavelengths | 375 nm, 488 nm, 561 nm, 640 nm |
| Detection Channels | 4 independent PMT detectors |
| Filter Wheels | 7-position per channel |
| Spatial Resolution | 0.5 µm/pixel |
| Scan Area | 18 mm × 18 mm (full slide, no tiling) |
| Scan Time | ≤17 min @ 0.5 µm/pixel |
| Output Format | 8-bit or 16-bit TIFF |
| Imaging Mode | Point-scanning confocal |
| Z-axis Auto-focus | Real-time dynamic focus tracking |