BrandArrayJet
OriginUnited Kingdom
ModelMercury 1000
Spotting MethodNon-contact piezoelectric inkjet
Spot Volume Rangepicoliter to nanoliter (pL–nL)
Spotting Speed711 spots per second
Substrate Capacity6 × SBS-compliant microtiter plates or 1,000 standard microscope slides
Repeatability (CV)< 5%
ComplianceDesigned for GLP/GMP-aligned workflows, compatible with ISO 13485 and ASTM E2539-22 reference practices for microarray fabrication
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArrayJet
OriginUnited Kingdom
ModelMercury 25
Spotting MethodNon-contact piezoelectric inkjet
Number of Parallel Nozzles128
Spotting Speed711 spots per second
Substrate Capacity1 × SBS-standard microplate or 25 × standard microscope slides (76 × 26 mm)
Spot-to-Spot ReproducibilityCV < 5%
Environmental ControlIntegrated humidity and temperature regulation with evaporation suppression
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArrayJet
OriginUnited Kingdom
ModelMercury 100
Spotting MethodNon-contact piezoelectric inkjet
Spot Volume Rangepicoliter to nanoliter (pL–nL)
Spotting Speed711 spots per second
Substrate Capacity6 × SBS-format microtiter plates or 100 standard microscope slides
Repeatability (CV)< 5%
ComplianceDesigned for GLP/GMP-aligned workflows, compatible with ISO 13485 and ASTM E2519-22 reference practices for microarray fabrication
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArrayJet
OriginUnited Kingdom
ModelMercury 100-S
Spotting MethodNon-contact piezoelectric inkjet
Spotting Speed711 spots/second
Substrate Capacity48 × SBS-format microplates or 100 × standard microscope slides (76 × 26 mm)
Spot-to-spot PrecisionCV < 5%
Dispense Volume Rangepicoliter to nanoliter
ComplianceDesigned for GLP/GMP-aligned workflows, compatible with ISO 13485 and ASTM E2578-07 (Standard Guide for Microarray Processing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandM2 Automation
OriginGermany
ModeliTWO-300P
Spotting TypeNon-contact piezoelectric dispensing
Spot Volume Range30 pL to 1 µL
Spotting SpeedUp to 1,000 droplets/sec
Substrate CapacityStandard microscope slides, 96-/384-/1536-well plates, films, discs, microfluidic chips
Repeatability±5 µm
Minimum Feature Size≤1 µm
Maximum Stage Velocity75 cm/s
CV (Coefficient of Variation)<2%
Compatible Spotting ModulesPiezo-based pL dispensers, M2MD nL dispensers, solenoid valves, multi-channel contact pins
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArrayJet
OriginUnited Kingdom
ModelMercury 1000-S
Spotting MethodNon-contact piezoelectric inkjet
Spot Volume Rangepicoliter to nanoliter (pL–nL)
Spotting Speed711 spots per second
Substrate Capacity48 SBS-format microplates or 1,000 standard microscope slides
Positional ReproducibilityCV < 5%
ComplianceCE-marked, ISO 13485–compatible workflow design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandM2 Automation
OriginGermany
ModeliONE-600
Spotting TechnologyNon-contact piezoelectric dispensing
Maximum Spotting Rate1000 spots/sec
Spot Volume Range30 pL to 1 µL
Positioning Repeatability±3 µm
Maximum Stage Speed100 cm/s
Slide/Plate Capacity80 standard microscope slides (75 × 25 mm)
Spotting Precision (CV)< 2%
Integrated Bubble Removal & FiltrationYes
Onboard Quality Control CamerasTop-view and droplet-view imaging
Environmental ControlHumidity and temperature stabilization module available
Added to wishlistRemoved from wishlist 0
Add to compare
BrandINNOPSYS
OriginGermany
ModelInnoQuant
Laser Wavelengths375 nm, 488 nm, 561 nm, 640 nm
Detection Channels4 independent PMT detectors
Filter Wheels7-position per channel
Spatial Resolution0.5 µm/pixel
Scan Area18 mm × 18 mm (full slide, no tiling)
Scan Time≤17 min @ 0.5 µm/pixel
Output Format8-bit or 16-bit TIFF
Imaging ModePoint-scanning confocal
Z-axis Auto-focusReal-time dynamic focus tracking