BrandDr-Water
OriginHunan, China
ModelDr-W960
Instrument TypePortable
Biological IndicatorBioluminescent Bacteria (Aliivibrio fischeri, Vibrio qinghaiensis, Photobacterium phosphoreum)
Operating Temperature10–40 °C (ambient)
Detection Time≤15 min post-sample preparation
Light Detection Range300–1100 nm
PhotodetectorSilicon Photomultiplier (SiPM)
Display5″ IPS Capacitive Touchscreen (1024×768)
Power SupplyRechargeable Li-ion Battery + AC Adapter
Data ConnectivityUSB-C, Wi-Fi, Bluetooth 5.0, 4G LTE
Data Storage≥10 million test records
ComplianceISO 11348-3, GB/T 15441-1995
Toxicity QuantificationRelative Luminescence Inhibition (%) → Converted to Equivalent Toxic Unit (TU) or Reference Toxicant (e.g., ZnSO₄·7H₂O mg/L)
Accuracy±1% RSD (n=3, vs. certified reference standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDr-Water
OriginHunan, China
ModelDr-W100
Instrument TypePortable/HANDHELD Water Quality Analyzer
Detection ParametersTurbidity, Color, Free Chlorine, Chlorine Dioxide, Total Hardness, Permanganate Index (COD<sub>Mn</sub>), Ammonia Nitrogen, Ozone, Urea, Iron, Manganese
Turbidity Ranges0–20 NTU / 0–200 NTU / 0–1000 NTU
Repeatability≤ ±2%
Accuracy≤ ±5%
Wavelength Range330–900 nm
Wavelength Accuracy±5 nm
Optical Resolution0.001 Abs
Optical Stability≤ ±0.005 Abs/20 min
Light SourceImported Cold LED (Lifespan >100,000 h)
Sample Cell16 mm & 25 mm Cuvettes
Display5-inch HD Color Touchscreen
Power SupplyRechargeable Li-ion Battery + AC Adapter
Data Storage1,000,000 Records
ConnectivityUSB Type-C (Charging & Data Transfer)
Calibration ModesBlank, Factor, and Calibration Curve
Readout UnitsConcentration or Absorbance
Housing MaterialCorrosion-Resistant ABS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDoctorWater
OriginHunan, China
ModelDr-W510
Instrument TypeBenchtop Laboratory Analyzer
Detection PrinciplePhotometric (Absorption Spectrophotometry)
Detectable MetalsMulti-parameter (e.g., Pb, Cd, Cr, Cu, Zn, Ni, As, Hg via compatible reagent kits)
Analysis Time≤10 minutes per sample
Accuracy≤±5%
Repeatability≤±2%
Wavelength Range330–900 nm
Wavelength Accuracy±5 nm
Absorbance Resolution0.001 Abs
Optical Stability≤±0.005 Abs / 20 min
Display8-inch HD color capacitive touchscreen
Language SupportEnglish & Chinese
Sample HoldersDual-position — 360° rotatable cuvette holder & standard 25 mm round cuvette slot
Light SourceImported long-life cold LED (≥100,000 h)
Calibration ModesBlank, Factor, and Calibration Curve
Data StorageUp to 1,000,000 measurement records
ConnectivityUSB interface
Output ModesConcentration (mg/L, µg/L) or Absorbance (Abs)
PrinterBuilt-in thermal printer
Housing MaterialCorrosion- and heat-resistant ABS
Dimensions (W×D×H)392 × 315 × 170 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWaterDoctor
OriginHunan, China
ModelDr-T8100
Instrument TypeBenchtop Laboratory Spectrophotometer
Detection ElementsChromium (Cr)
Detection Time10 min per sample
Accuracy≤ ±5%
Absorbance Resolution0.001 Abs
Wavelength Range190–1100 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability< 0.2 nm
Spectral Bandwidth2 nm
Transmittance Error±0.5%
Transmittance Repeatability≤ 0.2% T
Absorbance Repeatability≤ ±2%
Optical SystemDual-beam with Grating Monochromator
Light SourcesImported Deuterium Lamp (UV), Imported Tungsten-Halogen Lamp (Vis)
Display7-inch HD capacitive touchscreen
Sample HoldersDual independent positions — cylindrical cuvette (360° rotational alignment) and rectangular quartz/glass cuvette
Preloaded Calibration Curves1200 built-in methods
Data Storage1,000,000 measurement records
InterfaceUSB port for data export
Software LanguageChinese UI standard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDr-Water
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDr-W690
Detection PrincipleChlorophyll Fluorescence Method
Chlorophyll a Range0.01–500 µg/L
Cyanobacteria Range0–50 × 10⁶ cells/L
Detection Limit0.01 µg/L (Chl-a) / 1 × 10⁴ cells/L (Cyanobacteria)
Accuracy±5% FS
Resolution0.01 µg/L (Chl-a), 1 × 10⁴ cells/L (Cyanobacteria)
Measurement Time20 s
Display8-inch HD color TFT capacitive touchscreen
Sample CellDedicated 10-mm square quartz cuvette
Data Storage1,000,000 records with timestamp, ID, and operator tag
ConnectivityUSB 2.0 interface
Power SupplyAC 220 V ±10%, 50 Hz
Operating Environment5–40 °C, RH <85% non-condensing
Housing MaterialFlame-retardant ABS with IP54-rated enclosure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDoctorWater
OriginHunan, China
ModelW600
Detection PrincipleChlorophyll Fluorescence Method
Chlorophyll-a Range0.01–500 µg/L
Detection Limit0.01 µg/L
Cyanobacteria Range0–40 × 10⁶ cells/L
Resolution1 × 10⁴ cells/L (cyanobacteria), 0.01 µg/L (chlorophyll-a)
Accuracy±5%
Display8-inch IPS capacitive touchscreen (1024 × 768)
Operating SystemAndroid-based embedded OS
PowerRechargeable Li-ion battery + AC adapter
Data Storage≥10 million records
ConnectivityUSB, Wi-Fi, Bluetooth, 4G
ComplianceDesigned for field-deployable water quality monitoring per ISO 10260, ASTM D3921, and EPA Method 445.0 (fluorometric chlorophyll-a)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDoctorWater
OriginHunan, China
ModelDr-W120
Instrument TypePortable
Measurement PrincipleOptical (LED-based colorimetric method with interference-compensated photometry)
Measurement Range (DO)0.20–15.00 mg/L
Accuracy≤ ±5%
Repeatability≤ ±2%
Detection Limit0.20 mg/L
Wavelength Range330–900 nm
Wavelength Accuracy±5 nm
Absorbance Resolution0.001 Abs
Optical Stability≤ ±0.005 Abs/20 min
Display5-inch HD color capacitive touchscreen
Power SupplyRechargeable Li-ion battery + AC adapter
Data Storage1,000,000 measurement records
InterfaceUSB Type-C (charging & data transfer)
Calibration ModesBlank, Factor, and Curve calibration
Language SupportEnglish / Chinese switchable
Sample Format16 mm and 25 mm round cuvettes
Light SourceImported long-life cold LED (≥100,000 h)
Housing MaterialCorrosion-resistant ABS
PrinterBuilt-in thermal printer
Readout Unitsmg/L, ppm, or Abs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDoctorWater
OriginHunan, China
ModelDr-T9020
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleOptical (LED-based Photometry) + Electrochemical (Galvanic/Clark-type DO Sensor)
Measurement Range (DO)0–20 mg/L
Accuracy (DO)≤ ±5% FS
Repeatability (DO)≤ ±2% FS
Detection Limit (DO)Not Specified
Wavelength Range340–900 nm
Wavelength Accuracy±1 nm
Spectral Bandwidth4 nm
Absorbance Resolution0.001 Abs
Photometric Stability≤ ±0.005 Abs/20 min
Preloaded Calibration Curves1000+
Data Storage Capacity1,000,000 measurements
Display8-inch HD capacitive touchscreen
Interface LanguageChinese (English optional)
Sample HoldersRotatable 16-mm tube position + dual cuvette positions (10 mm & 30 mm pathlength) + 4 independent digital electrode ports
Power SupplyAC 100–240 V, 50/60 Hz
Dimensions (W×D×H)392 × 315 × 170 mm
Weight4.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDoctorWater
OriginHunan, China
ModelDr-W121
Instrument TypePortable
Wavelength Range330–900 nm
Wavelength Accuracy±5 nm
Photometric Accuracy≤±5%
Repeatability≤±2%
Absorbance Resolution0.001 Abs
Optical Stability≤±0.005 Abs/20 min
Detector SystemAutomatic Wavelength Positioning Optical Detection System
Display5-inch HD Color Touchscreen
Sample Format16 mm & 25 mm Cuvettes
Light SourceImported Cold LED (Lifespan >100,000 h)
Power SupplyRechargeable Li-ion Battery + AC Adapter
Data Storage Capacity1,000,000 Measurements
ConnectivityUSB Type-C (Charging & Data Transfer)
Calibration ModesBlank, Factor, and Calibration Curve
Readout UnitsConcentration (mg/L) or Absorbance (Abs)
Housing MaterialCorrosion-Resistant ABS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDoctor Water
OriginHunan, China
ModelDr-T9010
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleRapid Digestion Spectrophotometry (COD) & Nesslerization or Salicylate Method (Ammonia-N)
Wavelength Range340–900 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability<0.2 nm
Spectral Bandwidth4 nm
Photometric Accuracy±0.5% T
Photometric Repeatability≤0.2% T
Absorbance Resolution0.001 Abs
Optical Stability≤±0.005 Abs/20 min
Detection Range (COD)2–20,000 mg/L
Detection Range (NH₃-N)0.02–100 mg/L (configurable per method)
Accuracy≤±5%
Repeatability≤±2%
LOD (COD)2 mg/L
Measurement Time≤10 min (post-digestion)
CalibrationSingle- or Multi-point with Pre-stored Curves (n=1000)
Display8-inch HD Capacitive Touchscreen
Data Storage1,000,000 records
InterfaceUSB-A for U-disk export & thermal printer
Power SupplyAC 100–240 V, 50/60 Hz
Dimensions392 × 315 × 170 mm
Weight4.4 kg
Housing MaterialFlame-retardant ABS with Chemical Resistance
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDoctorWater
ModelDr-T9905
TypePortable/Water Quality Analyzer
Detection PrincipleDual-Mode Photometric & Electrochemical
Measurable ParametersCOD (2–20,000 mg/L), Ammonia-N, Total Phosphorus, Total Nitrogen, Heavy Metals, pH, Dissolved Oxygen, Conductivity, Turbidity, Temperature, ORP, TDS, Chlorophyll-a, Phycocyanin, SS, Residual Chlorine, Oil-in-Water, Salinity
Wavelength Range340–900 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability<0.2 nm
Spectral Bandwidth4 nm
Transmittance Error±0.5%
Transmittance Repeatability≤0.2% T
Absorbance Resolution0.001 Abs
Optical Stability≤±0.005 Abs/20 min
Pre-stored Calibration Curves600
Data Storage Capacity1,000,000 records
Display5-inch HD capacitive touchscreen
Power SupplyRechargeable Li-ion battery + AC adapter
ComplianceGB 11893–1989 (Total Phosphorus), GB/T 11894–1989 (Total Nitrogen), ISO 7027, ASTM D5810, EPA Method 351.2 (adapted)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWater Doctor
OriginHunan, China
ModelDr-W5000
Instrument TypePortable
Measurement PrincipleUltraviolet Fluorescence Spectrometry
Measurement Range0.005–1500 mg/L (as petroleum hydrocarbons)
Detection Limit0.005 mg/L
Accuracy±5% of reading
DetectorUV-optimized photomultiplier tube (PMT) with excitation at 254 nm and emission detection at 365 nm
Measurement Time≤120 seconds per sample
Display5-inch high-resolution color TFT touchscreen
Power SupplyRechargeable lithium-ion battery (standby >30 days
Data Storage1,000,000 measurement records with timestamp, sample ID, and calibration history
ConnectivityUSB 2.0 for data export and firmware update
Operating Environment5–40 °C, relative humidity <85% RH (non-condensing)
Sample VesselDedicated quartz-cuvette-compatible disposable glass tubes (10 mm pathlength)
Extraction Solventn-Hexane (ASTM D7066-compliant)
Auto-SleepActivated after 5 minutes of inactivity
Built-in Thermal PrinterYes
Color Compensation AlgorithmReal-time spectral correction for chromophoric interference
Onboard Calibration ModuleUser-accessible zero/span and multi-point calibration routines
ComplianceDesigned to support ASTM D7678, ISO 9377-2, and EPA Method 1664B workflows (extraction-dependent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWater Doctor
OriginHunan, China
ModelDr-W660
Measurement PrincipleIn-situ Fluorescence Detection
Chlorophyll-a Range0.01–500 µg/L
Phycocyanin (Cyanobacteria) Range0–40 × 10⁶ cells/L
Detection Limit0.01 µg/L (Chl-a), 1 × 10⁴ cells/L (Cyanobacteria)
Resolution0.01 µg/L (Chl-a), 10⁴ cells/L (Cyanobacteria)
Accuracy±5% FS
Display5-inch HD color capacitive touchscreen
PowerRechargeable Li-ion battery (≥30-day standby), AC adapter support
Data Storage1,000,000 records
InterfaceUSB 2.0
PrinterIntegrated thermal printer
Sample Cell10 mm square quartz cuvette
Housing MaterialCorrosion-resistant ABS
Operating Temp5–40 °C
Relative Humidity<85% RH (non-condensing)
ComplianceDesigned for field-deployable compliance with ISO 10260 (water quality — determination of chlorophyll-a by fluorescence), ASTM D7212-19 (standard test method for chlorophyll-a in water by fluorometric measurement)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWater Doctor
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDr-M5100
Instrument TypeLaboratory Benchtop Analyzer
PrincipleInfrared Spectrophotometry (Triple-Wavelength Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 3030 cm⁻¹)
Measurement Range0.0–800 mg/L (water matrix)
Detection Limit3σ ≤ 0.03 mg/L (based on 11 blank measurements)
Accuracy±2% relative error
Wavenumber Range2400–3400 cm⁻¹ (equivalent to 2941–4167 nm)
Wavenumber Accuracy±1 cm⁻¹
Absorbance Range0.0000–2.0000 AU (T = 100%–1%)
Extraction SolventsPerchloroethylene or Carbon Tetrachloride (compliant with HJ 637–2018)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWater Doctor (DoctorWater)
OriginHunan, China
ModelDr-W900
Instrument TypePortable
Biological IndicatorBioluminescent Bacteria (Aliivibrio fischeri, Photobacterium phosphoreum, Vibrio qinghaiensis)
Operating Ambient Temperature10–40 °C
Reagent Storage Temperature2–8 °C (adjustable, ±1 °C accuracy)
Detection Temperature Control15–25 °C (adjustable, ±1 °C accuracy)
Incubation Capacity10 sample positions with independent temperature control
Detection Time≤15 minutes post-sample preparation
ComplianceGB/T 15441–1995, ISO 11348-3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDoctorWater
OriginHunan, China
ModelDr-WCl
Instrument TypePortable
Measurement PrincipleDPD Colorimetric Spectrophotometry
Measuring ParameterFree Chlorine (Residual Chlorine)
Range0.02–2.00 mg/L
Accuracy≤ ±5%
Repeatability≤ ±2%
Resolution0.001 mg/L
LOD0.02 mg/L
Wavelength Range330–900 nm
Wavelength Accuracy±5 nm
Optical Stability≤ ±0.005 Abs/20 min
Display5-inch HD color TFT touchscreen
Light SourceImported long-life cold LED (≥100,000 h)
Sample Cell16 mm and 25 mm round cuvettes
Calibration ModesBlank, Factor, and Calibration Curve
Data StorageUp to 1,000,000 records
Power SupplyRechargeable Li-ion battery + AC adapter
InterfaceUSB Type-C (charging & data transfer)
Print OutputBuilt-in thermal printer
Readout ModesConcentration (mg/L) and Absorbance (Abs)
Housing MaterialCorrosion- and heat-resistant ABS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDoctorWater
OriginHunan, China
ModelDr-T8000
Instrument TypeLaboratory Water Quality Analyzer
Detection PrincipleSpectrophotometry (UV-Vis)
Measurable ParametersCOD, Ammonia Nitrogen, Total Phosphorus, Total Nitrogen, Turbidity, Color, Suspended Solids, Heavy Metals, and >50 additional water quality indicators
Wavelength Range190–1100 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability<0.2 nm
Spectral Bandwidth2 nm
Photometric Accuracy (Transmittance)±0.5%
Photometric Repeatability≤0.2% T
Absorbance Resolution0.001 Abs
COD Range2–20,000 mg/L
Measurement Repeatability≤±2%
Optical SystemDual-beam with Grating Monochromator
Light SourcesImported Deuterium Lamp (UV), Imported Tungsten-Halogen Lamp (Vis)
Display7-inch HD capacitive touchscreen
Sample HoldersDual independent positions — for 16-mm round cuvettes (360° rotational detection) and standard 10-mm square cuvettes
CalibrationSingle-point and multi-point calibration
Pre-stored Calibration Curves1200+ (compliant with HJ/T 399–2007, HJ 535–2009, GB 11893–1989, HJ 636–2012)
Data Storage1,000,000 measurement records
OutputBuilt-in thermal printer
InterfaceUSB port for data export
ComplianceDesigned to meet Chinese environmental monitoring standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDoctorWater
OriginHunan, China
ModelDr-YZ60
Instrument TypePortable/HANDHELD Water Quality Analyzer
Detection ParameterspH, Dissolved Oxygen (DO), Ammonia Nitrogen (NH₃-N), Nitrate Nitrogen (NO₃⁻-N), Nitrite Nitrogen (NO₂⁻-N), Water Temperature
pH Measurement Range6.5–8.5 pH
Repeatability≤ ±2%
Accuracy≤ ±5%
Wavelength Range330–900 nm
Wavelength Accuracy±5 nm
Optical Resolution0.001 Abs
Optical Stability≤ ±0.005 Abs/20 min
Light SourceImported Cold Light LED (Lifespan > 100,000 h)
Sample Cell16 mm & 25 mm Cuvettes
Display5-inch HD Color Touchscreen
Power SupplyRechargeable Li-ion Battery + AC Adapter
Data Storage Capacity1,000,000 Records
InterfaceUSB Type-C (Charging & Data Transfer)
Calibration ModesBlank, Factor, and Calibration Curve
Readout ModesConcentration & Absorbance
Housing MaterialCorrosion-Resistant ABS
PrintingBuilt-in Thermal Printer
Language SupportEnglish & Chinese
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWater Doctor
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDr-M1102
Instrument TypePortable
Measurement PrincipleElectrochemical (Ion-Selective Electrode)
Range0–100 mg/L NH₃–N
Accuracy±10% FS
Detection Limit0 mg/L (defined by electrode sensitivity and signal-to-noise ratio)
Measurement Time≤60 s per parameter
Simultaneous Channels6 independent electrode ports
Display8-inch HD color capacitive touchscreen
Data Storage1,000,000 measurement records with timestamp, location (optional GPS), and electrode ID
Power SupplyRechargeable Li-ion battery (≥12 h continuous operation)
IP RatingIP68 for electrodes
Operating Environment0–50 °C, ≤85% RH (non-condensing)
ConnectivityUSB 2.0, optional Bluetooth 5.0 module
Software ComplianceAudit-trail enabled logging, user-access levels, data export in CSV/Excel format
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDoctorWater
OriginHunan, China
ModelDr-M5600
Instrument TypePortable
Measurement PrincipleInfrared Spectrophotometry (Fourier-transform-free dispersive IR)
Measurement Range0.0–800 mg/L (oil in water)
Detection Limit3SD ≤ 0.03 mg/L (based on 11 blank measurements)
Wavenumber Accuracy±1 cm⁻¹
Absorbance Resolution0.0001 AU
Scan SpeedFull-spectrum acquisition in 30 seconds
Wavenumber Range2400–3400 cm⁻¹
Absorbance Range0.0000–2.0000 AU
RepeatabilityRSD ≤ 0.5% (20–80 mg/L standard), RSD ≤ 5% (0.2 mg/L sample)
LinearityR > 0.999
CalibrationPreloaded EPA- and HJ-compliant calibration curves
Power SupplyIntegrated rechargeable Li-ion battery + AC 220 V
Display10.1″ capacitive touchscreen
Data OutputThermal printer + USB interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWater Doctor
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelDr-M1202P
Instrument TypePortable
Measurement PrincipleElectrochemical (Ion-Selective Electrode, ISE)
Measurement Range0–100 mg/L NH₃–N
Accuracy±10% of reading
Detection Limit0 mg/L (defined by electrode sensitivity and signal-to-noise ratio)
Measurement Time≤60 seconds per sample
Sample ThroughputThree independent electrode measurement positions
Display5-inch HD color TFT touchscreen
Language SupportEnglish & Chinese
Data StorageUp to 1,000,000 measurement records
Power SupplyRechargeable Li-ion battery + USB Type-C AC/DC adapter (dual-mode operation)
Electrode Protection RatingIP68
Operating Environment0–50 °C, ≤85% RH (non-condensing)
Electrode Cable Length3–5 m (customizable)
Built-in Thermal PrinterYes
Data InterfaceUSB Type-C (for charging, data export, and firmware update)
Reading ModesReal-time, Timed, and Interval
Auto Temperature CompensationYes
Sleep ModeConfigurable idle timeout
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWater Doctor
OriginHunan, China
ModelDr-WCI
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleDPD Colorimetric Spectrophotometry (ASTM D1253, ISO 7393-2, EPA 330.5)
Measuring ParameterFree Chlorine (Residual Chlorine)
Range0.02–2.00 mg/L as Cl₂
Accuracy≤ ±5% of reading
Repeatability≤ ±2% RSD
Detection Limit0.02 mg/L
Absorbance Resolution0.001 Abs
Wavelength Range330–900 nm
Wavelength Accuracy±5 nm
Optical Stability≤ ±0.005 Abs / 20 min
Display8-inch HD capacitive touchscreen
Language SupportEnglish & Chinese
Sample HoldersRotatable 16-mm cuvette position + fixed 25-mm cuvette position
Calibration ModesBlank, Factor, and Multi-point Curve Calibration
Data StorageUp to 1,000,000 measurement records
ConnectivityUSB port for data export
Output ModesConcentration (mg/L) or Absorbance (Abs)
PrinterBuilt-in thermal printer
Housing MaterialFlame-retardant ABS with chemical resistance
Dimensions (W×D×H)392 × 315 × 170 mm
Light SourceLong-life imported cold LED (rated >100,000 hours)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDoctorWater
OriginHunan, China
ModelDr-T9904
Measurement MethodPhotometric (UV-Vis Spectrophotometry)
Range0–100 mg/L TN
Accuracy≤ ±5%
Detection Limit0 mg/L (as reported
Resolution0.001 Abs
Wavelength Range340–900 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability<0.2 nm
Spectral Bandwidth4 nm
Transmittance Error±0.5%
Transmittance Repeatability≤0.2% T
Optical Stability≤±0.005 Abs/20 min
Light SourceImported Cold LED (Lifespan >100,000 h)
Display8-inch HD Capacitive Touchscreen
Sample HoldersRotatable Cuvette Holder (360°), Dual Cuvette Positions (10 mm & 30 mm pathlength), 4 Independent Digital Electrode Ports
CalibrationSingle- and Multi-point Standard Curve Generation
Preloaded Curves1,000 Method-Specific Calibration Curves
Data Storage1,000,000 Records with Timestamp, Operator ID, and Batch Traceability
OutputThermal Printer, USB Export (CSV), On-screen Graphing & Filtering
HousingCorrosion-Resistant ABS Enclosure
Dimensions392 × 315 × 170 mm
Weight4.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDr-Water
OriginHunan, China
ModelDr-W130
Wavelength Range330–900 nm
Wavelength Accuracy±5 nm
Photometric Accuracy≤±5%
Repeatability≤±2%
Absorbance Resolution0.001 Abs
Optical Stability≤±0.005 Abs/20 min
Light SourceImported Cold LED (Lifespan >100,000 h)
Display5-inch HD Color TFT Touchscreen
Sample Format16 mm & 25 mm Cuvettes
Calibration ModesBlank, Factor, and Calibration Curve
Data StorageUp to 1,000,000 Records
Power SupplyRechargeable Li-ion Battery + AC Adapter
InterfaceUSB Type-C (Charging & Data Transfer)
Housing MaterialCorrosion-Resistant ABS
Readout ModesConcentration & Absorbance
Turbidity Measurement ModesStandard, Low-Turbidity, Signal-Averaging, and Rapid-Settling
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0