BrandWater Doctor
OriginHunan, China
ModelDr-W5000
Instrument TypePortable
Measurement PrincipleUltraviolet Fluorescence Spectrometry
Measurement Range0.005–1500 mg/L (as petroleum hydrocarbons)
Detection Limit0.005 mg/L
Accuracy±5% of reading
DetectorUV-optimized photomultiplier tube (PMT) with excitation at 254 nm and emission detection at 365 nm
Measurement Time≤120 seconds per sample
Display5-inch high-resolution color TFT touchscreen
Power SupplyRechargeable lithium-ion battery (standby >30 days
Data Storage1,000,000 measurement records with timestamp, sample ID, and calibration history
ConnectivityUSB 2.0 for data export and firmware update
Operating Environment5–40 °C, relative humidity <85% RH (non-condensing)
Sample VesselDedicated quartz-cuvette-compatible disposable glass tubes (10 mm pathlength)
Extraction Solventn-Hexane (ASTM D7066-compliant)
Auto-SleepActivated after 5 minutes of inactivity
Built-in Thermal PrinterYes
Color Compensation AlgorithmReal-time spectral correction for chromophoric interference
Onboard Calibration ModuleUser-accessible zero/span and multi-point calibration routines
ComplianceDesigned to support ASTM D7678, ISO 9377-2, and EPA Method 1664B workflows (extraction-dependent)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWater Doctor
OriginHunan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDr-M5100
Instrument TypeLaboratory Benchtop Analyzer
PrincipleInfrared Spectrophotometry (Triple-Wavelength Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 3030 cm⁻¹)
Measurement Range0.0–800 mg/L (water matrix)
Detection Limit3σ ≤ 0.03 mg/L (based on 11 blank measurements)
Accuracy±2% relative error
Wavenumber Range2400–3400 cm⁻¹ (equivalent to 2941–4167 nm)
Wavenumber Accuracy±1 cm⁻¹
Absorbance Range0.0000–2.0000 AU (T = 100%–1%)
Extraction SolventsPerchloroethylene or Carbon Tetrachloride (compliant with HJ 637–2018)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDoctorWater
OriginHunan, China
ModelDr-M5600
Instrument TypePortable
Measurement PrincipleInfrared Spectrophotometry (Fourier-transform-free dispersive IR)
Measurement Range0.0–800 mg/L (oil in water)
Detection Limit3SD ≤ 0.03 mg/L (based on 11 blank measurements)
Wavenumber Accuracy±1 cm⁻¹
Absorbance Resolution0.0001 AU
Scan SpeedFull-spectrum acquisition in 30 seconds
Wavenumber Range2400–3400 cm⁻¹
Absorbance Range0.0000–2.0000 AU
RepeatabilityRSD ≤ 0.5% (20–80 mg/L standard), RSD ≤ 5% (0.2 mg/L sample)
LinearityR > 0.999
CalibrationPreloaded EPA- and HJ-compliant calibration curves
Power SupplyIntegrated rechargeable Li-ion battery + AC 220 V
Display10.1″ capacitive touchscreen
Data OutputThermal printer + USB interface