Industrial Process Control Instruments
Filter
Showing 61–90 of 490 results
| Brand | AII |
|---|---|
| Origin | USA |
| Model | GPR-2900 |
| Measurement Principle | Electrochemical Fuel Cell |
| Range Options | 0–1%, 0–5%, 0–10%, 0–25% O₂ by volume (FS) |
| Accuracy | < ±1% FS |
| Linearity | >0.995 |
| Response Time (t₉₀) | ≤10 seconds |
| Sensitivity | <0.5% FS |
| Pressure Range (Inlet) | 5–30 psig (max 100 psig) |
| Outlet Pressure | Ambient |
| Flow Rate | 1–5 SCFH (recommended: 2 SCFH) |
| Temperature Range (Sensor) | GPR-11-60-4: –10 to +45°C |
| XLT-11-24-4 | –20 to +45°C |
| Compensation | Automatic temperature and barometric pressure compensation |
| Output Signals | 0–1 VDC analog + isolated 4–20 mA |
| Display Resolution | 0.001% O₂ |
| Enclosure | Anodized aluminum panel-mount housing |
| Certifications | CE, ISO 9001 |
| Compliance | Designed for general-purpose industrial environments per IEC 61000-6-2/6-4 and EN 61326-1 |
| Brand | AII |
|---|---|
| Origin | USA |
| Model | GPR-3100 |
| Measurement Principle | Electrochemical Fuel Cell |
| Full Scale Range | 0–100% O₂ |
| Selectable Sub-Ranges | 50–100%, 80–100%, 90–100% O₂ |
| Accuracy | < ±1% FS |
| Linearity | > 0.995 |
| Response Time (T₉₀) | 13 s |
| Sensitivity | 0.1% RD |
| Operating Temperature | 5–45 °C |
| Inlet Pressure | 5–30 psig |
| Outlet Pressure | Ambient |
| Sample Flow Rate | 1–3 SCFH (recommended: 2 SCFH) |
| Temperature & Barometric Pressure Compensation | Yes |
| Output Signals | 0–1 V analog, isolated 4–20 mA |
| Display Resolution | 0.01% O₂ |
| Enclosure Type | Aluminum panel-mount housing |
| Certifications | CE, ISO 9001 |
| Compliance | Designed for general-purpose industrial use per IEC 61000-6-2/6-4 and EN 61326-1 |
| Brand | AII |
|---|---|
| Origin | USA |
| Model | GPR-3500MO |
| Principle | Supergalvanic electrochemical sensor |
| Range | 0–100% O₂ |
| Accuracy | ±0.1% O₂ (at ambient temperature, atmospheric pressure, and fixed flow rate) |
| Resolution | 0.01% O₂ |
| Linearity | R² > 0.995 |
| Response Time (t₉₀) | 13 seconds |
| Sensor Lifetime | >24 months |
| Certifications | ISO 9001, CE, CSA/NRTL |
| Power | Rechargeable battery with 220 V AC charger |
| Display | Backlit LCD showing real-time O₂ concentration, sample pressure, and temperature |
| Sample Flow Rate | 0.2–3 L/min (recommended: 1 L/min) |
| Calibration Gas | 98–100% O₂ standard |
| Operating Pressure Range | 5–100 psig (with automatic pressure compensation) |
| Operating Temperature Range | –5 to +45 °C (with automatic temperature compensation) |
| Gas Path Components | Integrated flow control valve, rotameter, rapid purge system, 1/8" Swagelok® compression fittings |
| Enclosure | Anodized aluminum, NEMA 4X rated |
| Dimensions | 5" × 9" × 3" (127 × 229 × 76 mm) |
| Weight | 8 lbs (3.6 kg) |
| Brand | AII |
|---|---|
| Origin | USA |
| Model | OMD-501X |
| Sensor Principle | Electrochemical Fuel Cell |
| Output | 4–20 mA, 1–5 VDC, Dual Alarm Relays, Modbus RTU over RS485 |
| Power Input | 9–28 VDC or 100–240 VAC |
| Enclosure | IP65-rated ABS, 1/4 DIN panel mount |
| Operating Temperature | 5–45°C (TO2 series), –20–45°C (PO2 series) |
| Response Time (t₉₀) | ≤15 s |
| Accuracy | ±1% of full scale |
| Linearity | >0.995 FS |
| Pressure Range | 0–3 MPa inlet, vent to atmosphere |
| Flow Rate | 0.25–2.5 L/min (recommended: 1 L/min) |
| Resolution | 0.01 ppm |
| Calibration | Certified standard gas at ~80% FS |
| Compensation | Integrated temperature and pressure compensation |
| Sensor Lifetime | 24 months at 25°C |
| Warranty | 12 months (instrument + sensor) |
| Sample Compatibility | N₂, Ar, He, H₂, CO₂, C₂H₂, C₂H₄, C₄H₆, hydrocarbons, inert & reactive backgrounds |
| Optional Sensor Types | TO2-1x (ppm, inert background), TO2-2x (ppm, CO₂-tolerant), PO2-160 (%O₂), PO2-24 (%O₂, CO₂-tolerant) |
| Remote Sensor Housing | 6 ft cable included |
| Mounting Options | KF-40 flange (glovebox), flow-through body with 6 mm / 1/8″ / 1/4″ compression fittings |
| Data Storage | 8 GB USB logging |
| Display | Backlit LCD, menu-driven interface |
| Brand | AlphaOmega |
|---|---|
| Origin | USA |
| Model | 2520 |
| Measurement Ranges | 0–1%, 0–5%, 0–10%, 0–25%, 0–50%, 0–100% O₂ |
| Accuracy | ±0.1% FS |
| Linearity | ±0.1% FS |
| Response Time (t₉₀) | <10 s |
| Sensor Type | Electrochemical (O₂-specific) |
| Sample Temperature | 0–50 °C |
| Sample Pressure | 0.1–1 kg/cm² |
| Sample Flow Rate | 0.5–1.0 L/min |
| Temperature Compensation | Built-in |
| Display | 3½-digit LCD |
| Power | Rechargeable NiCd battery + universal AC adapter (battery charges during AC operation) |
| Enclosure | NEMA 1-rated polycarbonate |
| Dimensions | 5.8" H × 6.7" W × 3.4" D |
| Weight | <1 kg |
| Inlet/Outlet | Quick-connect fittings |
| Integrated Components | 12 VDC sampling pump, flowmeter with control valve at outlet |
| Analog Output | None |
| Brand | AlphaOmega |
|---|---|
| Origin | USA |
| Model | ZRO 2000 |
| Measurement Range | 0–100% O₂ (ppb–100% trace-to-full scale) |
| Accuracy | ±2% of reading (subject to clean, non-reducing sample gas) |
| Operating Temperature | 10–40 °C |
| Sample Gas Temperature Limit | ≤50 °C |
| Sample Pressure Range | 0.007–0.035 kg/cm² (≈1–5 psig) |
| Relative Humidity Limit | ≤85% RH |
| Power Input | 90–264 VAC, 50/60 Hz |
| Analog Output | Selectable 0–20 mA or 4–20 mA DC |
| Alarm Outputs | Two SPDT relays (10 A @ 30 VDC / 115–230 VAC) |
| Display | 6-digit LCD, 0.7" character height (17.8 mm) |
| Enclosure | Aluminum, NEMA 1-rated |
| Dimensions | 13" H × 10.71" W × 6.3" D |
| Sample Connection | 1/4" stainless steel compression fittings |
| Sensor Type | Heated zirconia electrochemical cell |
| Internal Audible Alarm | Yes, with front-panel mute switch |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3050-AM |
| Pricing | Available Upon Request |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3050-DO |
| Pricing | Available Upon Request |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Model | 3050-OLV |
| Measurement Principle | Quartz Crystal Oscillation (QCM) |
| Output Units | ppmv H₂O, °C露点 (Dew Point Temperature at Specified Pressure) |
| Compliance | Suitable for Class I, Div 1 Hazardous Areas (with optional enclosure) |
| Certifications | ATEX, IECEx (optional), UL/cUL Listed |
| Typical Pressure Range | 0.1–10 MPa (user-configurable compensation) |
| Response Time (t₉₀) | < 60 s |
| Detection Limit | < 1 ppmv H₂O in gas streams |
| Brand | AMETEK |
|---|---|
| Origin | Canada |
| Model | IPS-4 |
| Measurement Principle | Dual-Wavelength Ultraviolet and Infrared Absorption Spectroscopy |
| Compliance | Designed for hazardous area installation (Class I, Div 1/Zone 1 optional), CE, RoHS, ATEX/IECEx certification available per configuration |
| Sample Interface | In-situ probe or extractive gas cell (standard 1–5 m pathlength) |
| Output | 4–20 mA analog + Modbus RTU/TCP digital interface |
| Environmental Rating | IP66/NEMA 4X enclosure |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5900 |
| Pricing | Available Upon Request |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 888 |
| Pricing | Available Upon Request |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | iCinac |
| Channel Capacity | 16 or 32 simultaneous channels |
| Measurement Parameters | pH, Temperature (°C), Redox Potential (mV) |
| Power Supply | 110–220 V AC ±15%, 50–60 Hz |
| Dimensions | 510 × 450 × 300 mm (L × W × H) |
| Weight | 11–13 kg |
| Sensor Interface | Digital ISM-compatible multiparameter electrodes (pH/T/Redox) with embedded calibration memory |
| Data Output | 32 configurable outputs (digital + dual analog: 0–10 V / 4–20 mA) |
| Software | iCINAC v5.x with real-time compensation, audit trail, and GLP-compliant data logging |
| Brand | AMS |
|---|---|
| Origin | Germany |
| Model | RHADOX 7100 |
| Explosion Protection | ATEX II 2G Ex pxb IIB+H2 T4 Gb X (Zone 1) / ATEX II 3G IIB+H2 T3 Gc (Zone 2) |
| Response Time (T90) | 10–30 s |
| Repeatability | ≤1.0% of measured value |
| Long-term Drift | ≤2% of full scale per month |
| Temperature Drift | <0.02% / K (relative to span end) |
| Air Demand Range | 1.5–30 m³ air/m³ gas |
| Wobbe Index Range | 5–120 MJ/m³ |
| Analog Output | 2 × 4–20 mA (galvanically isolated) |
| Display | 2×16-character backlit LCD + optional full-color status display |
| Operating Temperature | –5°C to +45°C (electronics), +5°C to +60°C (gas path) |
| Gas Inlet/Outlet | 6/12 mm stainless steel tubing or flanged connections |
| Sample Flow Rate | 20–100 Nl/h (process gas), 50–500 Nl/h (instrument air) |
| Gas Pressure | ≥0.1 bar(g), max 17 bar(g) |
| Instrument Air | ≥2 bar(g), max 8 bar(g) |
| Power Supply | 115/230 V AC, 50–60 Hz, 500 VA |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 1000×900×350 mm |
| Weight | ~100–125 kg (configurable) |
| Brand | AMS |
|---|---|
| Origin | Germany |
| Model | RHADOX 7100/7100EX/7300/7300EX |
| Repeatability | CARI & Wi ≤ 1.0% of reading |
| Drift | ≤ 2% of reading/month |
| Response Time (T90) | 10–30 s (gas viscosity-dependent) |
| Explosion Protection | ATEX II 2G Ex pxb IIB+H2 T4 Gb X (Zone 1) |
| Operating Temperature | +5 °C to +60 °C |
| Sample Flow Rate | 20–100 NL/h (gas), 50–500 NL/h (instrument air) |
| Gas Inlet Pressure | ≥ 0.1 bar(g) (7100 series), ≥ 0.5 bar(g) (7300 series), max 17 bar(g) |
| Instrument Air Pressure | ≥ 2 bar(g), max 8 bar(g) |
| Analog Outputs | 2 × 4–20 mA (7100), 4 × 4–20 mA (7300), galvanically isolated |
| Digital Interface | RS232 (standard), optional RS485 or Ethernet |
| Measurement Parameters | Wobbe Index (Wi), Combustion Air Requirement Index (CARI), Specific Gravity (SG), Lower Calorific Value (LCV) |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | APT2000 |
| Pricing | Available Upon Request |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TDP2021 |
| Pricing | Available Upon Request |
| Brand | Antek by PAC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | NSure |
| Price Range | USD 70,000 – 140,000 (FOB) |
| Detection Principle | Ultraviolet Fluorescence (UVF) |
| Compliance | ASTM D5453, D6667, SH/T 0689, ISO 20846, GB/T 11060.8 |
| Measurement Range | 0–8000 ppm total sulfur |
| Repeatability | ≤1% RSD |
| Cycle Time | 1–5 min (typ. 3 min) |
| Accuracy | ≤1% FS |
| Output | 4–20 mA analog + fault alarm |
| Enclosure Rating | NEC Class 1 Div 2 Groups A, B, C, D / ATEX Zone 1 Ex db ib px b IIC T4 Gb |
| Sample Phase | Liquid or gas |
| Max Inlet Pressure | 400 psig |
| Max Inlet Temp | 100 °C |
| Sample Filtration | ≥0.5 µm |
| Carrier Gas | Instrument air (99.975%, 50 psig, 5–15 cc/min) |
| Combustion Air | Instrument air (99.975%, 50 psig, 350–500 cc/min) |
| Power | 230 VAC, 6.5 A, 50–60 Hz, 1500 W |
| Operating Ambient | 0–40 °C |
| Display | 7″ Siemens industrial touchscreen HMI |
| Cooling | Integrated Peltier-cooled UVF detector |
| Dryer | Membrane-type water removal module |
| Flow Control | Electronically regulated mass flow controllers |
| Architecture | Modular single- or dual-stream configuration |
| DCS Interface | 3/4″ NPT(F) with explosion-proof junction box and sealed conduit entries |
| Communication Protocol | RS-458 Modbus RTU (standard) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Industrial Process Analyzer |
| Model | Cobrix 5501/5601 & Cobrix 7501/7601 |
| Measurement Parameters | °Brix (0–50), %Diet (0–150), CO₂ (0–6 vol. / 0–12 g/L), Alcohol (0–16% w/w or 0–20% v/v), Total Acidity (TA), Conductivity, Colorimetry, Dissolved Oxygen |
| Accuracy | ±0.02 °Brix (sugared), ±0.5% Diet (sugar-free) |
| Temperature Range | 0–30 °C (5501/5601), 0–25 °C (7501/7601) |
| IP Rating | IP65+ |
| Max. Sensor-to-Unit Distance | 250 m |
| Communication | Ethernet (Davis 5 software), 4–20 mA analog outputs, digital I/O, fieldbus interfaces (PROFIBUS, Modbus TCP, EtherNet/IP) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | L-Dens |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | L-Sonic 5100 / L-Sonic 6100 |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Oxy 5100 |
| Price | Upon Request |
| Resolution | 0.4 ppb |
| Measurement Range | 0–2000 ppb or 0–24 ppm |
| Repeatability | ≤0.5 ppb or ≤1 % of reading |
| Long-term Stability | ≤0.8 ppb per 24 h |
| Temperature Compensation Range | –5 °C to +40 °C |
| Communication Interfaces | Analog Output (AO), Analog Input (AI), Digital Input (DI), Digital Output (DO), CAN bus |
| Dimensions (H × W × D) | 174 mm × 174 mm × 230 mm |
| Operating Ambient Temperature | –5 °C to +50 °C |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Wine Monitor |
| Pricing | Available Upon Request |
| Brand | API |
|---|---|
| Origin | USA |
| Model | SPN300 |
| Sensor Type | Capacitive/Inductive |
| Resolution | 0.1 µm |
| Dynamic Response | 25 kHz |
| Measurement Range | 0.1–0.8 mm |
| Linearity | < 0.1% FS |
| Thermal Stability | < 0.1% / °C |
| Sensor Dimensions | 30.5 mm (Ø) × 53.3 mm (L) |
| Brand | Apure |
|---|---|
| Model | A10CD-A / A10CD-S |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Measurement Range | 0.05 µS/cm – 200 mS/cm |
| Resistivity Range | 0.00 – 20.00 MΩ·cm |
| Temperature Range | 0–60 °C |
| Resolution | 0.01 µS/cm |
| Output | Dual isolated 4–20 mA (conductivity/resistivity & temperature) |
| Relay Outputs | 2 programmable SPDT relays (3 A / 250 V AC, NO contact) |
| Power Supply | AC 220 V or DC 24 V |
| Power Consumption | ≤5 W |
| Enclosure Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Panel Cutout | 92.5 × 92.5 mm |
| Temperature Compensation | Automatic (PT1000 or NTC10K) or Manual |
| Display Language | Switchable between Chinese and English |
| Environmental Rating | 0–60 °C ambient, ≤85% RH non-condensing |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A10CD-AA1 |
| Conductivity Range | 0.05 µS/cm – 200 mS/cm |
| Resistivity Range | 0.00 – 20.00 MΩ·cm |
| Temperature Range | 0–100 °C (manual or automatic with PT1000/NTC10K sensor) |
| Basic Accuracy | ±0.01 µS/cm |
| Resolution | 0.01 µS/cm |
| Dimensions | 96 × 96 × 132 mm (H×W×D) |
| Power Supply | AC 220 V or DC 24 V |
| Power Consumption | ≤5 W |
| Operating Environment | 0–60 °C, ≤85% RH |
| Output | Dual isolated 4–20 mA (conductivity/resistivity + temperature) |
| Relay Outputs | 2 programmable SPDT relays (3 A / 250 V AC, NO contact) |
| Enclosure Rating | IP65 front panel |
| Mounting Cutout | 92.5 × 92.5 mm |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | A10DO-AA1 |
| Price | USD 105 (FOB Shanghai) |
| Measurement Range | 0.00–20.00 ppm |
| Resolution | 0.01 ppm |
| Stability | ≤ 0.02 ppm/24 h |
| Temperature Compensation | 0–100 °C (manual or automatic via PT1000/NTC10K sensor) |
| Output Interfaces | Dual isolated 4–20 mA outputs (configurable for DO and temperature), RS485 optional |
| Relay Outputs | 2 programmable SPDT relays (3 A / 250 V AC, NO contact), adjustable hysteresis |
| Power Supply | AC 220 V ±10% / DC 24 V ±10%, ≤ 5 W |
| Enclosure Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Panel Cutout | 92.5 × 92.5 mm |
| Operating Environment | 0–60 °C, ≤ 85 % RH (non-condensing) |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A10PR-A |
| Measurement Range | pH 0.00–14.00 |
| ORP | −1999 to +1999 mV |
| Resolution | 0.01 pH / 1 mV |
| Accuracy | ±0.01 pH / ±1 mV |
| Temperature Compensation | 0–100 °C (manual, PT1000, or NTC10K) |
| Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Power Supply | AC 220 V or DC 24 V |
| Power Consumption | ≤5 W |
| Environmental Operating Range | 0–60 °C, ≤85% RH |
| Output | Dual isolated 4–20 mA outputs (configurable for pH/ORP and temperature) |
| Relay Outputs | Two programmable SPST relays (3 A / 250 V AC, NO contact), adjustable hysteresis |
| Stability | ≤0.02 pH/24 h |
| Mounting Cutout | 92.5 × 92.5 mm |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A10PR-AA1 |
| Price | USD 70 (FOB) |
| pH Range | 0.00–14.00 pH |
| ORP Range | −2000 to +2000 mV |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±1 mV, ±0.2 °C |
| Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Temperature Compensation | Automatic (PT1000/NTC10K) or Manual (0–100 °C) |
| Output | Dual isolated 4–20 mA outputs (configurable for pH/ORP and temperature, max load 500 Ω) |
| Relay Outputs | Two programmable SPDT relays (3 A / 250 V AC, NO contact), adjustable hysteresis |
| Power Supply | AC 220 V ±10% or DC 24 V ±10%, ≤5 W |
| Operating Environment | 0–60 °C, ≤85% RH (non-condensing) |
| Panel Cutout | 92.5 × 92.5 mm |
| Brand | APURE |
|---|---|
| Model | A10PR-SA1-CCEP |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Measurement Range | pH 0.00–14.00 |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Temperature Compensation | 0–100 °C (Manual / PT1000 / NTC10K) |
| Output | Isolated 4–20 mA (pH or temperature selectable) |
| Communication | MODBUS RTU (RS-485) |
| Relay Outputs | 2 × SPDT, 3 A / 250 V AC, programmable high/low setpoints with adjustable hysteresis |
| Power Supply | AC 220 V, ≤7 W |
| Dimensions | 96 mm (H) × 96 mm (W) × 132 mm (D) |
| Panel Cutout | 92.5 mm × 92.5 mm |
| Operating Environment | 0–50 °C, ≤85% RH (non-condensing) |
| Data Logging | Real-time pH trend + 30-event relay alarm history |
| User Interface | Dual-language (Chinese/English), menu-guided navigation |
| Security | Password-protected configuration access |