Industrial Process Control Instruments
Filter
Showing 91–120 of 1030 results
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | High-Performance Process Controller |
| Pricing | Available Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Fermentation Monitor 5100 |
| Measurement Range | 0–30 °Plato / 0–10 %v/v ethanol |
| Temperature Control Range | −20 °C to +100 °C |
| Wetted Materials | Stainless Steel 1.4404, PEEK, Sapphire (Al₂O₃, 99.997 % purity) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | L-Col 6100 |
| Pricing | Available upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | L-Com 5500 |
| Price | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | L-Dens 2300 |
| Price | Upon Request |
| Measurement Principle | Oscillating U-tube (Digital Density Measurement) |
| Accuracy | ±1 kg/m³ |
| Density Range | 500–2000 kg/m³ |
| Temperature Range (Process) | –10 °C to +60 °C (up to +95 °C for 30 min, GLS FCM version) |
| Pressure Rating (Absolute) | Up to 6 bar (GLS), up to 16 bar (GLS FCM) |
| Recommended Flow Rate | 10–80 L/h |
| Wetted Materials | Borosilicate glass / PVDF / Kalrez (GLS) |
| Communication Interface | RS-232 |
| Process Connection | G 1/8" female thread or flange adapters |
| Dimensions (L×W×H) | 88×38×48 mm (GLS), 126×56×46 mm (GLS FCM), 99×34×38 mm (GLS PP), 134×64×64 mm (SST E) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | L-Dens 3300 |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | L-Dens |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | L-Rix 4100 / L-Rix 5100 / L-Rix 5200 |
| Refractive Index Range | 1.31–1.54 |
| Accuracy | ±0.0002 nD (equivalent to ±0.1% w/w) |
| Temperature Control Range | −20 °C to 120 °C |
| Wetted Materials | Stainless Steel 1.4404, PEEK, Sapphire (Al₂O₃ – 99.997%), EPDM O-ring 60×3 (VARIVENT N, Shore A 70) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | L-Sonic 5100 / L-Sonic 6100 |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Oxy 5100 |
| Price | Upon Request |
| Resolution | 0.4 ppb |
| Measurement Range | 0–2000 ppb or 0–24 ppm |
| Repeatability | ≤0.5 ppb or ≤1 % of reading |
| Long-term Stability | ≤0.8 ppb per 24 h |
| Temperature Compensation Range | –5 °C to +40 °C |
| Communication Interfaces | Analog Output (AO), Analog Input (AI), Digital Input (DI), Digital Output (DO), CAN bus |
| Dimensions (H × W × D) | 174 mm × 174 mm × 230 mm |
| Operating Ambient Temperature | –5 °C to +50 °C |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Wine Monitor |
| Pricing | Available Upon Request |
| Brand | API |
|---|---|
| Origin | USA |
| Model | SPN300 |
| Sensor Type | Capacitive/Inductive |
| Resolution | 0.1 µm |
| Dynamic Response | 25 kHz |
| Measurement Range | 0.1–0.8 mm |
| Linearity | < 0.1% FS |
| Thermal Stability | < 0.1% / °C |
| Sensor Dimensions | 30.5 mm (Ø) × 53.3 mm (L) |
| Brand | Apure |
|---|---|
| Model | A10CD-A / A10CD-S |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Measurement Range | 0.05 µS/cm – 200 mS/cm |
| Resistivity Range | 0.00 – 20.00 MΩ·cm |
| Temperature Range | 0–60 °C |
| Resolution | 0.01 µS/cm |
| Output | Dual isolated 4–20 mA (conductivity/resistivity & temperature) |
| Relay Outputs | 2 programmable SPDT relays (3 A / 250 V AC, NO contact) |
| Power Supply | AC 220 V or DC 24 V |
| Power Consumption | ≤5 W |
| Enclosure Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Panel Cutout | 92.5 × 92.5 mm |
| Temperature Compensation | Automatic (PT1000 or NTC10K) or Manual |
| Display Language | Switchable between Chinese and English |
| Environmental Rating | 0–60 °C ambient, ≤85% RH non-condensing |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A10CD-AA1 |
| Conductivity Range | 0.05 µS/cm – 200 mS/cm |
| Resistivity Range | 0.00 – 20.00 MΩ·cm |
| Temperature Range | 0–100 °C (manual or automatic with PT1000/NTC10K sensor) |
| Basic Accuracy | ±0.01 µS/cm |
| Resolution | 0.01 µS/cm |
| Dimensions | 96 × 96 × 132 mm (H×W×D) |
| Power Supply | AC 220 V or DC 24 V |
| Power Consumption | ≤5 W |
| Operating Environment | 0–60 °C, ≤85% RH |
| Output | Dual isolated 4–20 mA (conductivity/resistivity + temperature) |
| Relay Outputs | 2 programmable SPDT relays (3 A / 250 V AC, NO contact) |
| Enclosure Rating | IP65 front panel |
| Mounting Cutout | 92.5 × 92.5 mm |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | A10DO-AA1 |
| Price | USD 105 (FOB Shanghai) |
| Measurement Range | 0.00–20.00 ppm |
| Resolution | 0.01 ppm |
| Stability | ≤ 0.02 ppm/24 h |
| Temperature Compensation | 0–100 °C (manual or automatic via PT1000/NTC10K sensor) |
| Output Interfaces | Dual isolated 4–20 mA outputs (configurable for DO and temperature), RS485 optional |
| Relay Outputs | 2 programmable SPDT relays (3 A / 250 V AC, NO contact), adjustable hysteresis |
| Power Supply | AC 220 V ±10% / DC 24 V ±10%, ≤ 5 W |
| Enclosure Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Panel Cutout | 92.5 × 92.5 mm |
| Operating Environment | 0–60 °C, ≤ 85 % RH (non-condensing) |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A10PR-A |
| Measurement Range | pH 0.00–14.00 |
| ORP | −1999 to +1999 mV |
| Resolution | 0.01 pH / 1 mV |
| Accuracy | ±0.01 pH / ±1 mV |
| Temperature Compensation | 0–100 °C (manual, PT1000, or NTC10K) |
| Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Power Supply | AC 220 V or DC 24 V |
| Power Consumption | ≤5 W |
| Environmental Operating Range | 0–60 °C, ≤85% RH |
| Output | Dual isolated 4–20 mA outputs (configurable for pH/ORP and temperature) |
| Relay Outputs | Two programmable SPST relays (3 A / 250 V AC, NO contact), adjustable hysteresis |
| Stability | ≤0.02 pH/24 h |
| Mounting Cutout | 92.5 × 92.5 mm |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A10PR-AA1 |
| Price | USD 70 (FOB) |
| pH Range | 0.00–14.00 pH |
| ORP Range | −2000 to +2000 mV |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±1 mV, ±0.2 °C |
| Dimensions | 96 × 96 × 132 mm (H × W × D) |
| Temperature Compensation | Automatic (PT1000/NTC10K) or Manual (0–100 °C) |
| Output | Dual isolated 4–20 mA outputs (configurable for pH/ORP and temperature, max load 500 Ω) |
| Relay Outputs | Two programmable SPDT relays (3 A / 250 V AC, NO contact), adjustable hysteresis |
| Power Supply | AC 220 V ±10% or DC 24 V ±10%, ≤5 W |
| Operating Environment | 0–60 °C, ≤85% RH (non-condensing) |
| Panel Cutout | 92.5 × 92.5 mm |
| Brand | APURE |
|---|---|
| Model | A10PR-SA1-CCEP |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Measurement Range | pH 0.00–14.00 |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Temperature Compensation | 0–100 °C (Manual / PT1000 / NTC10K) |
| Output | Isolated 4–20 mA (pH or temperature selectable) |
| Communication | MODBUS RTU (RS-485) |
| Relay Outputs | 2 × SPDT, 3 A / 250 V AC, programmable high/low setpoints with adjustable hysteresis |
| Power Supply | AC 220 V, ≤7 W |
| Dimensions | 96 mm (H) × 96 mm (W) × 132 mm (D) |
| Panel Cutout | 92.5 mm × 92.5 mm |
| Operating Environment | 0–50 °C, ≤85% RH (non-condensing) |
| Data Logging | Real-time pH trend + 30-event relay alarm history |
| User Interface | Dual-language (Chinese/English), menu-guided navigation |
| Security | Password-protected configuration access |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | A11PR-AA1 |
| Price | USD 70 (FOB Shanghai) |
| Measurement Range | pH: 0.00–14.00 |
| ORP | −2000 to +2000 mV |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±1 mV, ±0.2 °C |
| Dimensions | 96 mm (H) × 96 mm (W) × 128 mm (D) |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | A20CD-AA1 |
| Conductivity Range | 0.05 µS/cm – 200 mS/cm |
| Resistivity Range | 0.00 – 20.00 MΩ·cm |
| Temperature Range | −30 °C to +150 °C (manual or automatic with PT1000/NTC10K sensor) |
| Basic Accuracy | ±0.01 µS/cm |
| Resolution | 0.01 µS/cm |
| Dimensions | 144 mm (H) × 144 mm (W) × 115 mm (D) |
| Power Supply | AC 220 V or DC 24 V |
| Power Consumption | ≤5 W |
| Environmental Operating Conditions | 0–60 °C, ≤85% RH (non-condensing) |
| Mounting Cutout | 138 mm × 138 mm |
| Analog Outputs | Two isolated 4–20 mA outputs (conductivity/resistivity and temperature, max. load 500 Ω) |
| Relay Outputs | Two SPDT relays (3 A / 250 V AC, NO contact), configurable for high/low alarm with adjustable hysteresis |
| Display Language | Switchable between Chinese and English |
| Password Protection | User-accessible configuration lock |
| Menu Navigation | Context-sensitive on-screen prompts |
| Brand | APURE |
|---|---|
| Model | A20PR-AA1 |
| Measurement Range | pH 0.00–14.00 |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Temperature Compensation | 0–100 °C (manual, PT1000, or NTC10K) |
| Output | Isolated 4–20 mA (dual optional), RS-485 Modbus RTU (optional) |
| Relay Outputs | 2 configurable SPDT relays (3 A/250 VAC), including self-cleaning function |
| Power Supply | AC 220 V or DC 24 V |
| Enclosure Dimensions | 144 × 144 × 115 mm (H × W × D) |
| Panel Cutout | 138 × 138 mm |
| Stability | ≤0.02 pH/24 h |
| Operating Environment | 0–60 °C |
| Power Consumption | ≤5 W |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | A30CD-AA1 |
| Conductivity Range | 0.05 µS/cm – 200 mS/cm |
| Resistivity Range | 0.00 – 20.00 MΩ·cm |
| Temperature Range | 0–100 °C |
| Basic Accuracy | ±0.01 µS/cm |
| Resolution | 0.01 µS/cm |
| Dimensions (H×W×D) | 48 × 96 × 110 mm |
| Mounting Cutout | 42 × 90 mm |
| Output | Isolated 4–20 mA (configurable for conductivity, resistivity, or temperature) |
| Relay Output | 1 × SPDT, 3 A / 250 V AC, programmable high/low alarm with adjustable hysteresis |
| Power Supply | AC 220 V ±10% or DC 24 V ±10% |
| Power Consumption | ≤15 W |
| Operating Environment | 0–60 °C, ≤85% RH (non-condensing) |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | A30PR-AA1 |
| Price | USD 55 (FOB) |
| pH Range | 0.00–14.00 |
| ORP Range | −1999 to +1999 mV |
| pH Resolution | 0.01 |
| ORP Resolution | 1 mV |
| pH Accuracy | ±0.01 |
| ORP Accuracy | ±1 mV |
| Temperature Compensation | 0–100 °C (Manual / Automatic with PT1000 or NTC10K sensor) |
| Stability | ≤0.02 pH/24 h |
| Output | Isolated 4–20 mA (max. load 500 Ω) |
| Relay Output | 1 × SPDT, 3 A / 250 V AC (configurable high/low alarm with adjustable hysteresis) |
| Display | Custom segment LCD |
| Power Supply | AC 220 V ±10% or DC 24 V ±10% |
| Power Consumption | ≤15 W |
| Operating Environment | 0–60 °C, ≤85% RH (non-condensing) |
| Dimensions (H×W×D) | 48×96×110 mm |
| Panel Cutout | 42×90 mm |
| Brand | APURE |
|---|---|
| Model | BT-280 |
| Measurement Range | pH 0.00–14.00 |
| Resolution | 0.01 pH |
| Accuracy | ±1% FS ±1 digit |
| Temperature Compensation | 0–100 °C (manual, PT1000, or NTC10K) |
| Output | Isolated 4–20 mA (configurable for pH, ORP, or temperature |
| Relay Outputs | 2 SPST relays (3 A / 250 VAC, NO contact |
| Power Supply | AC 220 V ±10% or DC 24 V ±10% |
| Dimensions | 96 × 96 × 110 mm (H × W × D) |
| panel cutout | 91 × 91 mm |
| Operating Environment | 0–50 °C |
| Stability | ≤0.1 pH/24 h |
| Brand | Apure |
|---|---|
| Model | RP-3000 |
| Measurement Range | pH 0–14, ORP −1999 to +1999 mV |
| Resolution | 0.01 pH, 1 mV |
| Accuracy | ±0.01 pH, ±1 mV |
| Temperature Compensation | 0–100 °C (manual/automatic with PT1000 sensor) |
| Output | Dual isolated 4–20 mA (pH and ORP configurable) |
| Relay Outputs | 2 SPDT relays (configurable high/low alarm for pH or ORP) |
| Display | 800×480 IPS color LCD |
| Enclosure Rating | IP65 |
| Dimensions | 144×144×115 mm (H×W×D) |
| Power Supply | AC 100–240 V, ≤5 W |
| Operating Environment | 0–60 °C, ≤85% RH |
| Calibration | Manual 2- or 3-point using standard buffers (pH 4.00, 6.86, 7.00, 9.18, 10.00) |
| Stability | ≤0.02 pH/24 h, ≤3 mV/24 h |
| Brand | APURE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RW-60 |
| Output Signal | 4–20 mA analog + RS485 Modbus RTU digital |
| Display | Backlit LCD with bilingual (English/Chinese) UI |
| Power Supply | 24 VDC ±15% |
| Environmental Rating | IP66 |
| Operating Temperature | –10 to 60 °C |
| Temperature Compensation | Automatic, high-precision thermistor-based |
| Relay Outputs | 2 configurable SPDT relays (max. 5 A @ 250 VAC) |
| Measurement Principle | Time-of-Flight (ToF) ultrasonic echo detection |
| Typical Range | 0.3 to 6.0 m (adjustable via software) |
| Repeatability | ±1 mm |
| Response Time | < 2 s (configurable) |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AS860 |
| Price | USD 17,200 (FOB) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | CGA |
| Price | USD 28,000 (approx.) |
| Linearity Error | <0.1% FS |
| Repeatability | <0.1% FS |
| Span Drift | ≤1% per 30 days |
| Response Time (T90) | 5 seconds |
| Explosion Protection | Not certified (non-hazardous area use only) |
| Sensor Technologies | FID, NDIR, Paramagnetic, Electrochemical (eCell), Alumina-based Hygrometer (Al₂O₃), EPD (Electrostatic Precipitation Detector) |
| Temperature Compensation | Integrated |
| Pressure Compensation | Integrated |
| Calibration Options | Multi-point auto-calibration available per module |
| Module Architecture | Up to 3 internal sensor modules + 1 external Al₂O₃ module |
| Data Logging | Onboard with real-time trend visualization |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA0211 |
| Repeatability | ±1% FS |
| Detection Limit | 0.03 ppm |
| Detector Type | TCD (Thermal Conductivity Detector) |
| Column Oven Temperature Range | 5 °C to 45 °C |
| Carrier Gas Purity Requirement | 5N (99.999%) |
| Compliance | Designed for continuous online operation in industrial process environments |
| Configuration | Modular sensor architecture with field-replaceable sensing modules |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA0221 |
| Repeatability | < ±0.1% O₂ |
| Detection Limit | < ±0.1% O₂ |
| Detector Type | Paramagnetic |
| Column Temperature Control Range | 5 °C to 45 °C |
| Gas Supply Purity | 5N (99.999%) |
| Output | 4–20 mA |
| Communication | RS-485, Ethernet, Modbus (optional) |
| Relay Outputs | 3 × user-configurable dry-contact relays |
| Data Export | CSV format |
| Calibration | Auto/manual zero/span, multi-point, calendar-based scheduling, programmable purge time, intelligent stability detection |