Industrial Process Control Instruments
Filter
Showing 451–480 of 1088 results
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202D |
| Measurement Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Resolution | 0.001 ppm / 0.01 ppb |
| Temperature Compensation | −10 to 130 °C (manual/automatic |
| Communication Interface | RS485 Modbus RTU |
| Dimensions | 144 × 144 × 108 mm |
| Operating Temperature | −10 to 70.0 °C |
| Storage Temperature | −20 to 70.0 °C |
| Accuracy | ±0.02 ppm / ±0.02 ppb |
| Display | Backlit dot-matrix LCD (dual-language: English/Chinese) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS) |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, panel-mount, pipe-mount |
| Cutout Size | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Measurement Principle | Clark-type Polarographic |
| Measurement Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Resolution | 0.001 ppm / 0.01 ppb |
| Accuracy | ±0.02 ppm / ±0.02 ppb |
| Temperature Compensation Range | –10 to 130 °C (manual or automatic, NTC10K/PT1000 supported) |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD (bilingual: English/Chinese) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% F.S.) |
| Digital Interface | RS485 Modbus RTU |
| Cleaning Control Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC), with hysteresis setting |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Electrode Compatibility | Bsens420, Bsens430, Bsens440 polarographic sensors |
| Membrane Type | Gas-permeable Teflon®-based oxygen-selective membrane |
| Maintenance Requirement | Periodic electrolyte replenishment |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202D |
| Measurement Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Resolution | 0.001 ppm / 0.01 ppb |
| Temperature Compensation | −10 to +130 °C (manual or automatic, NTC10K/PT1000 sensor support) |
| Communication Interface | RS485 Modbus RTU |
| Dimensions | 144 × 144 × 108 mm (H × W × D) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Online DO Analyzer |
| Model | PM8202D |
| Measurement Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Resolution | 0.001 ppm / 0.01 ppb |
| Accuracy | ±0.02 ppm / ±0.02 ppb |
| Temperature Compensation | –10 to +130 °C (manual or automatic, NTC10K or PT1000 sensor support) |
| Operating Temperature | –10 to +70.0 °C |
| Storage Temperature | –20 to +70.0 °C |
| Display | Backlit dot-matrix LCD with DO, temperature, time, and relay status |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS, configurable for DO or temperature) |
| Communication | RS485 Modbus RTU |
| Cleaning Cycle Control | Interval 0.1–1000 h, duration 1–1000 s |
| Alarm Outputs | Two independent Hi/Lo relays (5 A / 250 VAC / 30 VDC, programmable hysteresis) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Electrode Compatibility | Bsens420, Bsens430, Bsens440 polarographic sensors |
| Membrane Type | Clark-type oxygen-permeable membrane |
| Maintenance Requirement | Periodic electrolyte replenishment |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Online DO Analyzer |
| Model | PM8202D |
| Measurement Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Resolution | 0.001 ppm / 0.01 ppb |
| Accuracy | ±0.02 ppm / ±0.02 ppb |
| Temperature Compensation | −10 to +130 °C (manual or automatic, NTC10K or PT1000 sensor input) |
| Operating Temperature | −10 to +70.0 °C |
| Storage Temperature | −20 to +70.0 °C |
| Enclosure Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Display | Backlit dot-matrix LCD (dual-language: English/Chinese) |
| Data Logging Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for DO or temperature) |
| Digital Communication | RS485 Modbus RTU |
| Relay Outputs | Two independent Hi/Lo alarm relays (5 A / 250 VAC / 30 VDC, programmable hysteresis) |
| Cleaning Cycle Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Installation Options | Wall-mount, pipe-mount, panel-mount |
| Ingress Protection | IP65 |
| Electrode Compatibility | Bsens420, Bsens430, Bsens440 polarographic sensors (Clark-type, membrane-covered, aqueous electrolyte-based) |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer | GreenPrima AG |
| Type | PM8202O |
| Resolution | 0.01 ppm |
| Measurement Range | 0.00–20.00 ppm |
| Repeatability | ±0.01 ppm |
| Stability | ±0.5% FS |
| Temperature Compensation | −10 to +130 °C (NTC10K/PT1000) |
| Output | Dual isolated 4–20 mA (max. 500 Ω, 0.1% FS), RS485 Modbus RTU (HART optional) |
| Cleaning Output | Adjustable interval (0.1–1000 h), duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relays (5 A / 250 VAC / 30 VDC) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Sensor Model | Bsens410 |
| Sensor Material | 316L stainless steel |
| Max. Pressure | 5 bar |
| Cable Length | 7 m |
| Sensor Protection Rating | IP68 |
| Ambient Operating Temperature | 0–70 °C |
| Storage Temperature | −20–70 °C |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Imported Industrial Process Analyzer |
| Model | PM8202P |
| Measurement Range | -2 to 16 pH, -2000 to +2000 mV, 0 to 130 °C |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±0.1 mV, ±0.1 °C |
| Temperature Compensation Range | -10 to 130 °C (Manual/Automatic |
| Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Imported |
| Model | PM8202P |
| Measurement Range | -2 to 16 pH, -2000 to +2000 mV, 0 to 130 °C |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±0.1 mV, ±0.1 °C |
| Temperature Compensation Range | -10 to 130 °C (Manual/Automatic |
| Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Industrial Instrument |
| Model | PM8202P |
| Measurement Range | -2 to 16 pH, -2000 to +2000 mV, 0 to 130 °C |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±0.1 mV, ±0.1 °C |
| Temperature Compensation Range | -10 to 130 °C (manual/automatic |
| Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Imported Industrial Online pH Meter |
| Model | PM8202P |
| Measurement Range | -2 to 16 pH, -2000 to +2000 mV, 0 to 130 °C |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±0.1 mV, ±0.1 °C |
| Temperature Compensation Range | -10 to 130 °C (manual/automatic |
| Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PRO LEV200 |
| Product Type | Ultrasonic Level Transmitter |
| Measuring Range | 6 m / 10 m |
| Blind Zone | 0.25 m / 0.5 m |
| Accuracy | ±0.2% F.S. |
| Display | LCD |
| Resolution | 1 mm |
| Max. Process Pressure | 1.5 bar |
| Operating Temperature | −30 to +70 °C |
| Housing Material | PC/PP |
| Output | 2-wire 4–20 mA (max. 750 Ω) |
| Power Supply | 24 VDC |
| Enclosure Rating | IP67 |
| Sensor Material | ETFE or PVDF |
| Communication | None (standard model) |
| Explosion Protection | Not applicable (non-ATEX version) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PRO LEV200 Plus |
| Product Type | Ultrasonic Level Meter |
| Measuring Range | 6 m / 10 m |
| Blind Zone | 0.25 m / 0.5 m |
| Accuracy | ±0.2% F.S. |
| Display | LCD |
| Resolution | 1 mm |
| Max. Process Pressure | 1.5 bar |
| Operating Temperature | −30 to +70.0 °C |
| Sensor Material | ETFE or PVDF |
| Housing Material | PC/PP |
| Output | 2-wire 4–20 mA (max. 750 Ω) |
| Power Supply | 24 VDC |
| Protection Rating | IP67 |
| Process Connection | G2" |
| Application | Solid & Liquid Level Measurement |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | PROL E V200 |
| Product Type | Ultrasonic Level Transmitter |
| Measurement Principle | Non-contact ultrasonic time-of-flight (ToF) |
| Output | 2-wire 4–20 mA (max. 750 Ω) |
| Display | LCD with 1 mm resolution |
| Accuracy | ±0.2% FS |
| Measuring Range | 6 m / 10 m (configurable) |
| Blind Zone | 0.25 m / 0.5 m |
| Operating Temperature | –30 to +70 °C |
| Maximum Process Pressure | 1.5 bar |
| Housing Material | PC/PP |
| Sensor Material | ETFE or PVDF |
| Ingress Protection | IP67 |
| Electrical Interface | G2" |
| Media Compatibility | Liquids and bulk solids |
| Environmental Compliance | ATEX II 1/2G Ex ia II C T6 (optional variant) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | PROL EV200 |
| Product Type | Ultrasonic Level Transmitter |
| Measurement Principle | Non-contact ultrasonic time-of-flight (ToF) |
| Max. Range | 10 m |
| Blind Zone | 0.5 m |
| Accuracy | ±0.2% FS |
| Display | Backlit LCD |
| Resolution | 1 mm |
| Operating Temperature | −30 to +70 °C |
| Enclosure Material | PC/PP |
| Sensor Material | ETFE or PVDF |
| Output | 2-wire 4–20 mA (max. 750 Ω) |
| Power Supply | 24 VDC |
| Ingress Protection | IP67 |
| Explosion Protection | ATEX II 1/2G Ex ia II C T6 |
| Process Connection | G2" |
| Maximum Process Pressure | 1.5 bar |
| Application Scope | Liquids and bulk solids in industrial process control |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROL EV200 |
| Product Type | Ultrasonic Level Transmitter |
| Measuring Range | 6 m / 10 m |
| Blind Zone | 0.25 m / 0.5 m |
| Accuracy | ±0.2% FS |
| Display | LCD |
| Resolution | 1 mm |
| Max. Process Pressure | 1.5 bar |
| Operating Temperature | −30 to +70 °C |
| Housing Material | PC/PP |
| Sensor Material | ETFE or PVDF |
| Output | 2-wire 4–20 mA (max. 750 Ω) |
| Power Supply | 24 VDC |
| Protection Rating | IP67 |
| Explosion Protection | None |
| Process Connection | G2" |
| Media Compatibility | Liquids and solids |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Level Meter |
| Model | PROL EV200 / PROL EV300 |
| Measurement Principle | Non-contact ultrasonic time-of-flight (ToF) |
| Range | 6 m / 10 m (selectable per variant) |
| Blind Zone | 0.25 m / 0.5 m |
| Accuracy | ±0.2% FS |
| Resolution | 1 mm |
| Max Process Pressure | 1.5 bar |
| Operating Temperature | −30 to +70 °C |
| Housing Material | PC/PP (EV200), Aluminum/PVDF (EV300) |
| Sensor Diaphragm Material | ETFE or PVDF |
| Output Options | 2-wire 4–20 mA (max 750 Ω), 4-wire 4–20 mA + Modbus RTU + dual relay, or 2-wire HART-enabled variants |
| Power Supply | 24 VDC |
| Ingress Protection | IP67 (EV200), IP68 (EV300) |
| Explosion Protection | ATEX II 1/2G Ex ia II C T6 |
| Process Connection | G2" |
| Media Compatibility | Liquids and bulk solids |
| Display | Backlit LCD |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ProLe v600 |
| Pricing | Available Upon Request |
| Measurement Principle | Non-contact ultrasonic level sensing with hydraulic algorithm-based flow calculation |
| Range | 5 m |
| Resolution | 1 mm |
| Blind Zone | 0.25 m |
| Accuracy | ±0.2% of Full Scale |
| Output Signals | 4–20 mA analog output, RS485 serial interface (Modbus RTU protocol) |
| Power Supply | 24 VDC |
| Operating Temperature | –30 to +70 °C |
| Maximum Pressure Rating | 1.0 bar |
| Process Connection | G2" (ISO 228-1) |
| Housing Material | Polycarbonate (PC) / Polypropylene (PP) blend |
| Ingress Protection | IP67 |
| Dimensions (L×W×H) | 138 × 246 × 134 mm |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROLEV 500D |
| Product Type | Level Meter |
| Controller Housing Material | ABS |
| Display | 320×240 matrix color LCD with backlight |
| Operating Temperature (Controller) | −20 to +60.0 °C |
| Output | 2 × 4–20 mA + Modbus RTU (RS-485) + 2 relays |
| Output Variant | 2 × 4–20 mA + Modbus RTU (RS-485) + 5 relays |
| Power Supply | 85–230 V AC or 24 V DC |
| Enclosure Rating (Controller) | IP66 |
| Mounting | Wall, pipe, or DIN rail |
| Dimensions (Controller) | 184 × 223 × 130 mm |
| Sensor Model | PSU06 / PSU12 |
| Measuring Range | 0.3–6 m / 0.5–12 m |
| Accuracy | ±0.2 % FS |
| Resolution | 1 mm |
| Max. Process Pressure | 1.0 bar |
| Operating Temperature (Sensor) | −30 to +70.0 °C |
| Sensor Housing Material | PC/PP |
| Cable Length | 10 m |
| Sensor IP Rating | IP68 |
| Process Connection | G1" |
| Sensor Diaphragm Material | ETFE or PVDF |
| Application Scope | Solids and liquids |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROLEV200 Plus |
| Product Type | Ultrasonic Level Transmitter |
| Measuring Range | 6 m / 10 m |
| Blind Zone | 0.25 m / 0.5 m |
| Accuracy | ±0.2% F.S. |
| Display | LCD |
| Resolution | 1 mm |
| Max. Process Pressure | 1.5 bar |
| Operating Temperature | −30 to +70.0 °C |
| Sensor Material | ETFE or PVDF |
| Housing Material | PC/PP |
| Output | 2-wire 4–20 mA (max. 750 Ω) |
| Power Supply | 24 VDC |
| Enclosure Rating | IP67 |
| Explosion Protection | None |
| Process Connection | G2" |
| Media Compatibility | Liquids and Solids |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROLEV V200 |
| Product Type | Ultrasonic Level Meter |
| Measuring Range | 6 m / 10 m |
| Blind Zone | 0.25 m / 0.5 m |
| Accuracy | ±0.2% F.S. |
| Display | LCD |
| Resolution | 1 mm |
| Max. Process Pressure | 1.5 bar |
| Operating Temperature | −30 to +70.0 °C |
| Sensor Material | ETFE or PVDF |
| Housing Material | PC/PP |
| Output | 2-wire 4–20 mA (max. 750 Ω) |
| Power Supply | 24 VDC |
| Protection Rating | IP67 |
| Explosion Protection | None |
| Process Connection | G2" |
| Application | Solid & Liquid Level Measurement |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Ultrasonic Level Transmitter |
| Model | PROLEV200 |
| Measurement Principle | Non-contact ultrasonic time-of-flight (ToF) |
| Max. Range | 10 m |
| Blind Zone | 0.5 m |
| Accuracy | ±0.2% FS |
| Output | 2-wire 4–20 mA (max. 750 Ω) |
| Display | Backlit LCD, 1 mm resolution |
| Operating Temperature | −30 to +70 °C |
| Enclosure Material | PC/PP |
| Sensor Diaphragm | ETFE or PVDF |
| Pressure Rating | 1.5 bar |
| Electrical Interface | G2" male thread |
| Ingress Protection | IP67 |
| Certification | ATEX II 1/2G Ex ia II C T6 (optional) |
| Compliance | IEC 61000-6-2/-6-4, IEC 61326-1, EN 61000-4-2/3/4/6 |
| Brand | GreenPrima |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | PROLEV200 / PROLEV300 |
| Measurement Range | 6 m / 10 m |
| Blind Zone | 0.25 m / 0.5 m |
| Accuracy | ±0.2% FS |
| Display | LCD |
| Resolution | 1 mm |
| Max Pressure | 1.5 bar |
| Operating Temperature | −30 to +70 °C |
| Housing Material | PC/PP (PROLEV200) / Aluminum/PVDF (PROLEV300) |
| Output | 2-wire 4–20 mA (max 750 Ω) / 4-wire 4–20 mA + Modbus RTU + dual relay |
| Power Supply | 24 VDC |
| Enclosure Rating | IP67 (PROLEV200) / IP68 (PROLEV300) |
| Process Connection | G2" |
| Sensor Diaphragm Material | ETFE or PVDF |
| Explosion Protection | ATEX II 1/2G Ex ia II C T6 (PROLEV300 variants) |
| Key | Model: ProLev300 |
|---|---|
| Measurement Principle | Non-contact ultrasonic time-of-flight |
| Range | 0.25–5 m (standard), 0.4–8 m (extended) |
| Blind Zone | 0.25 m / 0.4 m |
| Accuracy | ±0.2% of full scale |
| Resolution | 1 mm |
| Operating Temperature | −30 to +70 °C |
| Maximum Process Pressure | 1 bar |
| Housing Material | Anodized aluminum / PVDF |
| Electrical Connection | 4-wire (4–20 mA + Modbus RTU + 2 relay outputs) |
| Process Connection | G2" male thread |
| Ingress Protection | IP68 |
| Explosion Protection | ATEX II 1/2G Ex ia IIC T6 Ga |
| Power Supply | 24 VDC |
| Output Options | 4–20 mA, Modbus RTU (RS-485), dual SPDT relays |
| Sample Compatibility | Liquids and bulk solids in non-vacuum, non-foaming, low-dust industrial environments |
| Brand | GreenPrima |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | proLev500 / proLev500D |
| Product Type | Level Transmitter |
| Sensor Range | PU06: 0.3–6 m |
| PU12 | 0.5–12 m |
| Blind Zone | PU06: 0.3 m |
| PU12 | 0.5 m |
| Accuracy | ±0.2% of full scale |
| Resolution | 1 mm |
| Display | Color matrix LCD |
| Power Supply | 85–230 VAC or 24 VDC |
| Operating Temperature | Sensor: –25 to +75 °C |
| Controller | –10 to +60 °C |
| Enclosure Rating | Controller: IP66 |
| Sensor | IP68 |
| Max. Process Pressure | 0.5 bar |
| Housing Material | Polypropylene (PP) |
| Process Connection | G1" male thread |
| Cable Length | 10 m (separated configuration) |
| Language | English |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer | GreenPrima GmbH |
| Product Type | Ultrasonic Level Meter |
| Model | PROLEV500 |
| Sensor Models | PSU06 (0.3–6 m range), PSU12 (0.5–12 m range) |
| Accuracy | ±0.2% FS |
| Resolution | 1 mm |
| Max Process Pressure | 1.0 bar |
| Operating Temperature (Sensor) | −30 to +70 °C |
| Operating Temperature (Controller) | −20 to +60 °C |
| Sensor Housing Material | PC/PP |
| Controller Housing Material | ABS |
| Display | 320 × 240 pixel color LCD with backlight |
| Outputs | Dual 4–20 mA analog outputs + Modbus RTU (RS-485) + 2 relays (PROLEV500) or 5 relays (PROLEV500D) |
| Power Supply | 85–230 V AC or 24 V DC |
| Ingress Protection | IP66 (controller), IP68 (sensor) |
| Mounting Options | Wall, pipe, or DIN rail |
| Dimensions (Controller) | 184 × 223 × 130 mm |
| Cable Length | 10 m standard |
| Process Connection | G1" female thread |
| Sensor Diaphragm Material | ETFE or PVDF |
| Signal Processing | Microprocessor-based echo analysis with adaptive gain control, temperature compensation, and false-echo suppression |
| Brand | GreenPrima |
|---|---|
| Origin | Italy |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROLEV500 / PROLEV500D |
| Product Type | Level Transmitter |
| Sensor Range | 0.3–6 m (PSU06) / 0.5–12 m (PSU12) |
| Accuracy | ±0.2% FS |
| Resolution | 1 mm |
| Max Pressure | 1.0 bar |
| Sensor Operating Temp | −30 to +70.0 °C |
| Sensor Housing Material | PC/PP |
| Sensor Cable Length | 10 m |
| Sensor Process Connection | G1" |
| Sensor Protection Rating | IP68 |
| Transmitter Operating Temp | 0 to +70.0 °C |
| Display | LCD (level, temperature, status) |
| Outputs | Dual 4–20 mA + Modbus RTU (RS-485) + Dual Relay |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Transmitter Enclosure | IP65 |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Diaphragm Material | ETFE or PVDF |
| Brand | GreenPrima |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ProLev600 |
| Measurement Principle | Non-contact ultrasonic level sensing with hydraulic rating curve integration |
| Range | 5 m |
| Blind Zone | 0.25 m |
| Accuracy | ±0.2% of full scale (f.s.) |
| Resolution | 1 mm |
| Operating Temperature | −30 to +70 °C |
| Maximum Process Pressure | 1 bar |
| Housing Material | Polycarbonate (PC) / Polypropylene (PP) |
| Power Supply | 24 VDC |
| Output Signals | 4–20 mA (2-wire), Modbus RTU (RS-485), Two programmable relay outputs (dry contact, pulse-capable) |
| Dimensions (L×W×H) | 138 × 246 × 134 mm |
| Process Connection | G2" (ISO 228-1) internal thread |
| Ingress Protection | IP67 |
| Compatible Primary Devices | Palmer-Bowlus flumes, Parshall, Palmer-Bowlus, Palmer-Bowlus Jr., Palmer-Bowlus XL, Palmer-Bowlus XL-Plus, Palmer-Bowlus Mini, Palmer-Bowlus Micro, Palmer-Bowlus Nano, Palmer-Bowlus Ultra, Palmer-Bowlus Flex, Palmer-Bowlus Custom |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROLEV600 |
| Price | Upon Request |
| Measurement Principle | Non-contact ultrasonic time-of-flight level sensing |
| Flow Calculation Method | Velocity-Area method with integrated堰/Flume algorithms |
| Accuracy | ±0.2% F.S. |
| Range | 0–5 m (level) |
| Resolution | 1 mm |
| Blind Zone | 0.25 m |
| Operating Temperature | −30 to +70.0 °C |
| Housing Material | PC/PP blend |
| Output Signals | 4–20 mA (2-wire), Modbus RTU (RS-485) |
| Power Supply | 24 VDC (±15%) |
| Ingress Protection | IP67 |
| Maximum Process Pressure | 1.0 bar |
| Process Connection | G2" male thread |
| Dimensions (L×W×H) | 138 × 246 × 134 mm |
| Display | Backlit LCD with tactile keypad |
| Supported Flumes/Weirs | Palmer-Bowlus, Parshall, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowl...... (truncated for brevity — full list includes Parshall, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus, Palmer-Bowlus...... (truncated) |
| Environmental Suitability | Designed for long-term operation in wastewater, stormwater, and aggressive chemical effluents |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROLEV600 |
| Pricing | Available Upon Request |
| Measurement Principle | Non-contact ultrasonic time-of-flight level sensing |
| Range | 5 m |
| Resolution | 1 mm |
| Blind Zone | 0.25 m |
| Accuracy | ±0.2% of Full Scale (F.S.) |
| Output Signals | 4–20 mA analog output, RS485 serial interface with Modbus RTU protocol |
| Power Supply | 24 VDC |
| Operating Temperature | –30 to +70 °C |
| Maximum Pressure Rating | 1.0 bar |
| Process Connection | G2" (ISO 228-1) |
| Housing Material | Polycarbonate (PC) / Polypropylene (PP) blend |
| Ingress Protection | IP67 |
| Dimensions (L×W×H) | 138 × 246 × 134 mm |
| Brand | GreenPrima |
|---|---|
| Origin | Italy |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | PROLEV600 |
| Pricing | Upon Request |
| Measurement Principle | Non-contact ultrasonic time-of-flight level sensing |
| Range | 5 m |
| Accuracy | ±0.2% F.S. |
| Resolution | 1 mm |
| Blind Zone | 0.25 m |
| Operating Temperature | −30 to +70.0 °C |
| Housing Material | PC/PP |
| Output Signals | 4–20 mA, Modbus RTU (RS-485) |
| Power Supply | 24 VDC |
| Ingress Protection | IP67 |
| Maximum Pressure Rating | 1.0 bar |
| Process Connection | G2″ (ISO 228-1) |