Infrared Spectrometer
Filter
Showing 1–30 of 90 results
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB-Rx |
| Instrument Type | In-situ, Real-time FTIR Spectrometer |
| Spectral Range | 600–8000 cm⁻¹ (configurable by probe/fiber combination) |
| Resolution | Adjustable from 1 cm⁻¹ to 64 cm⁻¹ (in 2 cm⁻¹ increments) |
| Scan Speed | Variable, dependent on resolution and scan count |
| Signal-to-Noise Ratio | 50,000:1 (60 s acquisition, 4 cm⁻¹ resolution) |
| Detector | Uncooled Room-Temperature Pyroelectric (DTGS) |
| ATR Probe Materials | Hastelloy® C-276, ZnSe, Diamond, ZrO₂ |
| Fiber Types | Silver Halide (AgClBr), Sulfide Glass |
| Spectral Digitization | 24-bit ADC |
| Detection Limit | 0.1% w/w acetone in toluene (60 s, 4 cm⁻¹) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MB3000 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 490–8500 cm⁻¹ |
| Resolution | Adjustable from 1 to 64 cm⁻¹ (2× step increments) |
| Signal-to-Noise Ratio | 50,000:1 (60 s acquisition, 4 cm⁻¹ resolution) |
| Detector | DTGS |
| Beam Splitter | ZnSe |
| Interferometer | Dual-pivot Michelson with high-throughput optical design |
| Laser Source | Solid-state laser |
| ADC Resolution | 24-bit |
| Wavenumber Accuracy | < 0.01 cm⁻¹ (@1918 cm⁻¹) |
| Wavenumber Repeatability | < 0.001 cm⁻¹ (@1918 cm⁻¹) |
| Short-term Stability | < 0.09 % |
| Temperature Stability | < 1 %/°C |
| Power Consumption | 65 W |
| Dimensions | 435 × 280 × 372 mm |
| Weight | 24 kg |
| Compliance | CSA, RoHS, CE |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MR304/170 |
| Instrument Type | Fourier Transform Infrared Spectrometer |
| Spectral Resolution | Adjustable up to 1 cm⁻¹ |
| Data Interface | 100 Mbps Ethernet |
| Scan Speed | ≥83 Hz (12 ms per interferogram) |
| Field of View Options | 5 mrad, 28 mrad, 75 mrad |
| NESR | <1.0 × 10⁻⁹ W·cm⁻²·sr⁻¹·cm |
| Compliance | ASTM E1421, ISO 18356, MIL-STD-461G (EMC), GLP/GMP-ready data audit trail |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 4300 |
| Instrument Type | Handheld |
| Instrument Class | Fourier Transform Infrared (FTIR) |
| Spectral Range | 5,200–650 cm⁻¹ |
| Resolution | 4 cm⁻¹ (standard) |
| Detector | DTGS with Diamond ATR option |
| Sampling Modes | Diamond-ATR, Ge-ATR, Specular Reflectance, Diffuse Reflectance, Grazing Angle, Retro-reflector |
| Dimensions | 35 cm (H) × 19 cm (D) |
| Weight | 2.2 kg |
| Power Supply | Hot-swappable Li-ion battery (4 h typical runtime) / 100–240 VAC, 50/60 Hz |
| Software Platform | MicroLab Mobile, MicroLab Expert, optional MicroLab Pharma (21 CFR Part 11 & EU Annex 11 compliant) |
| Sample Types | Solids, Pellets, Liquids, Pastes, Powders, Gels |
| Library Options | Preloaded application-specific spectral libraries (ATR, geological minerals), customizable library creation |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 4500 |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared (FTIR) |
| Spectral Range | 4000–650 cm⁻¹ |
| Dimensions (W×H×D) | 29 cm × 19 cm × 22 cm |
| Weight | 6.8 kg |
| Power Supply | Internal rechargeable battery (up to 4 h operation) / 100–240 VAC, 50/60 Hz |
| Software | MicroLab FTIR and MicroLab Expert |
| Sample Types | Solids, pellets, liquids, pastes, powders, gels |
| Sampling Interfaces (Fixed Options) | Diamond ATR (1×, 3×, or 5× reflection), Multireflection ZnSe ATR, TumblIR, DialPath |
| Library Support | Application-specific spectral libraries pre-installed |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 5500 |
| Instrument Type | Laboratory Benchtop FTIR Spectrometer |
| Spectral Range | 4,000 to 650 cm⁻¹ |
| Dimensions (W × D × H) | 20 cm × 20 cm × 11 cm |
| Weight | 3.6 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Sampling Modules | Fixed Diamond ATR, Multireflection ZnSe ATR, TumblIR, DialPath |
| Software Platform | MicroLab, MicroLab Expert, MicroLab Quant, MicroLab Pharma (optional) |
| Library Support | Pre-validated application-specific spectral libraries |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Cary 630 |
| Instrument Type | Benchtop Fourier Transform Infrared Spectrometer |
| Wavenumber Range | KBr beam splitter: 7,000–350 cm⁻¹ |
| ZnSe beam splitter | 5,100–600 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Dimensions (W × D × H) | 14 × 26 × 16 cm |
| Weight | 3.5 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Sample Compatibility | Solids, powders, pellets, liquids, gels, pastes, gases |
| Sampling Modules | Diamond ATR, Multireflection ZnSe ATR, TumblIR, DialPath, Ge ATR, Mirror Reflection (10° and 45°), Transmission, Diffuse Reflectance, Gas Cell |
| Software | Agilent MicroLab, MicroLab Expert, MicroLab Pharma (optional, 21 CFR Part 11 & EU Annex 11 compliant) |
| Brand | AIRSENSE |
|---|---|
| Origin | Imported |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared (FTIR) |
| Model | MI10 |
| Wavenumber Range | 500–5000 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Compliance | Designed for field-deployable chemical identification in accordance with ISO 17025-aligned operational workflows |
| Software | Embedded real-time spectral acquisition and library-matching interface |
| Data Handling | On-device storage with USB export and optional cloud-sync capability |
| Environmental Rating | IP54-rated enclosure for dust and splash resistance |
| Power Supply | Rechargeable Li-ion battery (≥4 h continuous operation) |
| Dimensions & Weight | 320 × 240 × 120 mm |
| Brand | ARC |
|---|---|
| Origin | Switzerland |
| Model | FT-NIR Rocket |
| Instrument Type | Portable |
| Spectral Range | 900–2600 nm (11000–3800 cm⁻¹) |
| Resolution | 4 cm⁻¹ (≤0.8 nm @ 1100 nm, ≤2 nm @ 1700 nm, ≤5 nm @ 2600 nm) |
| Wavenumber Accuracy | <1 cm⁻¹ @ 4000 cm⁻¹ (25±5°C) |
| Signal-to-Noise Ratio | >10,000:1 (RMS, full spectrum, single scan) |
| Dynamic Range | >3000:1 |
| Scan Speed | 1 spectrum/sec (averaging mode) |
| A/D Conversion | 24-bit |
| Detector | InGaAs photodiode array |
| Reference Laser | Integrated solid-state 850 nm laser |
| Optical Interface | SMA905, fiber input ≥1 mm core, NA = 0.2 |
| Power Supply | 5 V DC via USB 2.0 |
| Operating Temperature | 10–30 °C |
| Dimensions | 180 × 160 × 80 mm |
| Weight | 850 g |
| Compliance | CE, RoHS, USB-IF certified |
| Brand | Arcoptix |
|---|---|
| Origin | Switzerland |
| Instrument Type | Laboratory FT-IR |
| Spectral Range | 5000–830 cm⁻¹ |
| Resolution | 0.5 cm⁻¹ (standard 4 cm⁻¹, optional down to 0.5 cm⁻¹) |
| Signal-to-Noise Ratio | > 1:40,000 (at 8 cm⁻¹, 60 s acquisition) |
| Detector | Peltier-cooled MCT (4-stage TE), ZnSe beamsplitter |
| Interface | USB 2.0 |
| Dimensions | 180 × 160 × 80 mm |
| Weight | 1.8 kg |
| Operating Temperature | 10–40 °C |
| Brand | Arcoptix |
|---|---|
| Origin | Switzerland |
| Model | FT-IR Rocket |
| Detector | Thermoelectrically Cooled HgCdTe (MCT) |
| Interferometer Type | Permanently Aligned Dual Corner-Cube Design |
| Reference Laser | Solid-State Stabilized Laser (PPM-level wavelength stability) |
| Spectral Range | Mid-Infrared (Typical 2–12 µm, configuration-dependent) |
| Optical Interface | Fiber-Coupled or Free-Space Input |
| Resolution | Up to 0.5 cm⁻¹ (configurable) |
| Scan Rate | Up to 10 scans/sec (typical) |
| Weight | < 1.2 kg |
| Dimensions | 120 × 85 × 65 mm |
| Brand | Arcoptix |
|---|---|
| Origin | Switzerland |
| Model | FT-IR Rocket |
| Detector | Thermoelectrically Cooled MCT (2-stage or 4-stage) |
| Spectral Range | Mid-IR (typically 2.5–12 µm / 4000–833 cm⁻¹, configuration-dependent) |
| Resolution | 4 cm⁻¹ or 8 cm⁻¹ |
| Coupling Options | Fiber-optic (SMA-905 or FC/PC) and Free-space |
| Light Source | Integrated Broadband IR Emitter |
| Compliance | CE-marked, RoHS-compliant |
| Software Interface | USB 2.0, SDK for LabVIEW, Python, MATLAB |
| Brand | ARCoptix |
|---|---|
| Origin | Switzerland |
| Model | FT-NIR 0.9–2.6 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Spectral Range | 900–2600 nm (3800–11,000 cm⁻¹) |
| Resolution | 4 cm⁻¹ |
| SNR | >200,000:1 (at 4 cm⁻¹, 60 s acquisition) |
| Wavelength Stability | <10 ppm long-term repeatability |
| Baseline Intensity Drift | <2% over 10 h (1100–2500 nm) |
| Detector | Extended-range InGaAs PIN photodiode (thermoelectrically cooled option available) |
| Data Acquisition Rate | 1 spectrum/s (continuous mode) |
| Interface | USB 2.0 (Ethernet optional) |
| A/D | 24-bit |
| Power | 7.5–12 V DC, 1–6 W |
| Operating Temperature | 5–40 °C |
| Dimensions | 180 × 160 × 80 mm |
| Weight | 1.7 kg |
| Brand | Arcoptix |
|---|---|
| Origin | Switzerland |
| Model | FTNIR-L1 |
| Instrument Type | Portable |
| Spectral Range | 11000–3850 cm⁻¹ (0.9–2.6 µm) |
| Resolution | 4 or 8 cm⁻¹ |
| Wavenumber Accuracy | < 2% (1100–2500 nm) over 10 hours |
| Detector | Single-element TE-cooled InGaAs photodiode |
| Input | Fiber-coupled |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | FR60 |
| Instrument Type | Portable Hybrid FTIR-Raman Spectrometer |
| IR Wavenumber Range | 4200–650 cm⁻¹ |
| Raman Wavenumber Range | 175–2800 cm⁻¹ |
| IR Resolution | < 4 cm⁻¹ |
| Raman Resolution | < 10 cm⁻¹ |
| Scan Speed | Full-spectrum acquisition in ≤ 5 seconds |
| Signal-to-Noise Ratio (SNR) | > 2000:1 (IR, 100 scans) |
| Wavenumber Accuracy | < ±0.1 cm⁻¹ at 2000 cm⁻¹ |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WQF-520A |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | Better than 0.5 cm⁻¹ |
| Scan Velocity | 2 mm/s (optical path difference rate) |
| Signal-to-Noise Ratio | >15,000:1 (at 4 cm⁻¹, 1 min scan, peak-to-peak) |
| Dimensions | 540 × 515 × 260 mm |
| Weight | 28 kg |
| Interface | USB 2.0 |
| Light Source | High-intensity air-cooled infrared source with spherical reflector |
| Detector | Standard DTGS or optional MCT (configurable) |
| Environmental Protection | Hermetically sealed Michelson interferometer with desiccant-view window |
| Software Platform | Windows-based native Chinese GUI with spectral library management, quantitative analysis, and GLP-compliant reporting modules |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | WQF-530A |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 350–7800 cm⁻¹ |
| Resolution | <0.85 cm⁻¹ (upgradable to ≤0.4 cm⁻¹) |
| Signal-to-Noise Ratio (S/N) | >20,000:1 (upgradable to 55,000:1) |
| Wavenumber Accuracy | <0.1 cm⁻¹ |
| Detector | DLATGS (Deuterated Triglycine Sulfate) with Temperature Stabilization |
| Scan Speed | Microprocessor-controlled, user-selectable |
| Data Interface | Ethernet (RJ-45), USB 2.0 |
| Software Compliance | 21 CFR Part 11-ready audit trail, electronic signature support |
| Operating System Compatibility | Windows 10/11 (64-bit) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | ALPHA II |
| Instrument Type | Benchtop Laboratory FT-IR Spectrometer |
| Spectral Range | 7500–375 cm⁻¹ |
| Spectral Resolution | 0.8 cm⁻¹ |
| Scan Speed | 3 spectra/sec |
| Signal-to-Noise Ratio | 50,000:1 (at 4 cm⁻¹, 1 min measurement) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CryoSAS |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 280–1500 cm⁻¹ |
| Cooling Method | Closed-Cycle Cryocooler (No Liquid Helium Required) |
| Detection Temperature | <15 K |
| Compliance | ASTM/SEMI MF1630 (B, P), ASTM/SEMI MF1391 (C, O) |
| Sensitivity | Boron/Phosphorus down to ppta |
| Vacuum System | Dual-Stage (Mechanical + Turbo Molecular Pump) |
| Sample Capacity | 9-Position Precision Stepper Motor Stage |
| Sample Holder | Gold-Plated OFHC Copper for Thermal Uniformity |
| Software | Dedicated Industrial QC Interface with Touchscreen Control & Automated Reporting |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | IFS 125HR |
| Instrument Type | Laboratory FTIR Spectrometer |
| Instrument Principle | Fourier Transform Infrared Spectroscopy |
| Configuration | Dual-Sample Chamber, Vacuum-Optimized |
| Optional Features | Dual-Sided Interferogram Acquisition, Hybrid Scanner Interferometer with Sliding Bearings, Integrated 24-bit Digitect™ ADC, Ethernet Data Interface |
| Spectral Range Extension Capability | Far-IR (down to 125 cm⁻¹) to UV (via optional sources/detectors) |
| Resolution Capability | < 0.0225 cm⁻¹ (at specified conditions) |
| Vacuum Compatibility | Yes |
| Compliance Context | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | INVENIO |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 8,000 – 350 cm⁻¹ |
| Spectral Resolution | 0.16 cm⁻¹ |
| Scan Speed | 20 spectra/sec |
| Signal-to-Noise Ratio | >10,000:1 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | LUMOS II ILIM |
| Instrument Type | Laboratory-based Laser IR Microscope |
| Instrument Category | FTIR Imaging Microscope with Integrated Laser Illumination Module |
| Application Domain | Chemical Imaging, Spatially Resolved Spectroscopy, Hyperspectral Mapping |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Portable |
| FT-IR Architecture | Interferometric (Michelson-type) |
| Wavenumber Range | 6000 – 670 cm⁻¹ |
| Detector | Thermoelectrically Cooled MCT (TE-MCT), No Liquid Nitrogen Required |
| Enclosure Rating | IP65 (Instrument Body), IP67 (Carrying Case) |
| Light Source | CenterGlow™ Broadband IR Source (Lifespan >5 years) |
| Interferometer | RockSolid™ Dynamic Alignment-Free Design (Lifespan >10 years) |
| Laser | Solid-State Diode Laser (Lifespan >10 years) |
| ATR Accessory | Heated Diamond Crystal |
| Power Supply | Integrated Rechargeable Lithium Battery (Field-Operable, Grid-Independent) |
| Software Platform | OPUS TOUCH™ (Touch-Optimized, Role-Based Workflow Interface) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | VERTEX 70v |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 10–30,000 cm⁻¹ |
| Spectral Resolution | ≤0.4 cm⁻¹ (standard), upgradable to 0.16 cm⁻¹ |
| Scan Speed | 80 scans/sec |
| Signal-to-Noise Ratio | 50,000:1 (at 4 cm⁻¹, 1 min measurement) |
| Interferometer | RockSolid™ permanently aligned, gold-coated optics |
| Vacuum Capability | Full-vacuum optical bench optional |
| Beam Splitter Exchange | Motorized BMS-c unit supports up to 4 beam splitters without breaking vacuum |
| Detector Compatibility | Up to 5 software-controlled detectors (RT, LN₂-cooled, LHe-cooled) |
| Compliance | ASTM E1421, ISO 17025, USP <851>, FDA 21 CFR Part 11 (with OPUS software suite) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | VERTEX 80 / VERTEX 80v |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 50000–5 cm⁻¹ |
| Spectral Resolution | < 0.06 cm⁻¹ |
| Scan Speed | 115 scans/sec |
| Signal-to-Noise Ratio | 55,000:1 |
| Interferometer | UltraScan™ True-Alignment Patent Interferometer |
| Optical Platform | Fully Vacuum-Compatible Cast-Aluminum Base (VERTEX 80v) |
| Data Acquisition | DigiTect™ Digital Detection Technology |
| Beam Splitter Exchange | Automated, Vacuum-Compatible BMS-c |
| Detector Channels | Dual-Channel, 24-bit High-Speed ADC |
| Light Sources | Integrated Air-Cooled Source + Optional External Water-Cooled High-Power Source |
| Beam Ports | 5 Output Ports + 2 Input Ports |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | VERTEX NEO R |
| Instrument Type | Laboratory FTIR Spectrometer |
| Vacuum Capability | Full Vacuum Optical Bench |
| Interferometer | RockSolid™ Permanent Alignment |
| Detector Technology | MultiTect™ Multi-Element Detector Platform |
| Instrument Class | Research-Grade FTIR |
| Compliance | Designed for ASTM E1421, ISO 17025-compliant laboratories, GLP/GMP-ready configuration options |
| Software | OPUS 8.5 with FDA 21 CFR Part 11–compliant audit trail and electronic signature modules |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Laboratory FTIR |
| Model | VERTEX NEO Ultra |
| Spectral Resolution | 0.04 cm⁻¹ |
| Vacuum Operation | Yes |
| Detector Configuration | Up to 6 integrated detectors (MultiTect) |
| Beam Path Environment | Fully evacuated optical bench |
| ATR Capability | Vacuum-compatible attenuated total reflection module |
| Scan Modes | Step-scan (μs–ns–ms dynamics), Rapid-scan |
| Interferometer | UltraScan with linear air-bearing mirror drive |
| THz Extension | verTera module compatible |
| Optical Path Flexibility | 5 output ports, 4 beam splitters, 4 sources, 6 detectors — all switchable under vacuum |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-0916 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 7800–350 cm⁻¹ |
| Resolution | Better than 1.0 cm⁻¹, continuously adjustable |
| Signal-to-Noise Ratio | 30,000:1 (peak-to-peak, 4 cm⁻¹, 1-minute scan) |
| Beam Splitter | Ge-coated KBr substrate |
| Source | High-energy, long-life IR source with auto-sleep function |
| Interferometer | Magnetically suspended planar mirror, electromagnetic drive Michelson interferometer (30° incidence angle) |
| Detector | Moisture-resistant high-sensitivity DLATGS detector |
| Quantification Method | FAME concentration calculated from absorbance at 1745 cm⁻¹ using ASTM D7371-compliant calibration |
| Interface | USB 2.0 high-speed bidirectional port |
| OS Compatibility | Windows XP through Windows 10 |
| Brand | Cloudoptek |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform Infrared (FTIR) & Raman Spectrometer |
| Model | DRF-600 |
| Compliance | CE, RoHS, ISO/IEC 17025–compatible operation environment |
| Brand | Cloudoptek |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform Infrared Spectrometer |
| Model | FTIR-800 |
| Key Specifications | ATR-based micro-FTIR optical architecture, solid/liquid sample compatibility, multi-component identification capability (≥3 components), fluorescence-insensitive detection, thermal-sensitive & energetic material compatible |
| Compliance | Designed to support field-deployable GLP-aligned workflows |