Empowering Scientific Discovery

Jiangsu Schuetz Measurement & Control Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSGC-100 CEMS-VOC
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS
OriginJiangsu, China
ModelSA-200 TCD
Detection PrincipleThermal Conductivity Detection (TCD)
Measuring RangeH₂ 0–99.999 vol% (configurable per background gas)
Accuracy±2% FS
Repeatability±1% FS
Stability±1% FS / 7 days
Response Time (T90)<30 s
Display240×128 LCD
Data StorageSD card (standard), USB flash drive (optional)
Output4–20 mA (default), configurable to 0–20 mA / 0–1 V / 0–5 V / 0–10 V / 1–5 V
CommunicationRS485 (standard), RS232 (optional)
Power Supply85–264 VAC, 50/60 Hz
Power Consumption<35 VA
Operating Temperature–10 to +45 °C
Relative Humidity<80% RH
Sample Flow Rate200–400 mL/min
Sample PressureAmbient ±10% (at outlet)
Inlet/Outlet Port1/4" NPT internal thread, stainless steel
Enclosure Dimensions483 × 300 × 177 mm (L×W×H)
MountingPanel mount, cutout 445 × 180 mm (rectangular), fixing holes Φ6 × 4 at 465 × 101.5 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelS-Handheld 10
PricingUpon Request
Detection PrinciplesInfrared (NDIR), Electrochemical, PID, Catalytic Bead
Sensor LifespanElectrochemical: 2–3 years
NDIR5–10 years
Catalytic Bead~3 years
PID2–3 years
Response Time (T90)≤60 s
Operating Temperature5–45 °C
Relative Humidity Range10–95 %RH (non-condensing)
Barometric Pressure Measurement300–1100 hPa (±1 hPa accuracy)
Power Supply5 VDC, rechargeable 6800 mAh Li-ion battery
RuntimeUp to 8 h (pump-on continuous operation)
Display4.3″ TFT-LCD, 800 × 480 resolution
Sampling MethodIntegrated active pump, 300 mL/min flow rate
FiltrationBuilt-in hydrophobic particulate filter and water trap
Data Storage100,000 records (concentration + timestamp + alarm flags)
ConnectivityUSB Type-C (data transfer & charging), optional Bluetooth 5.0
Dimensions217 × 92 × 80 mm (L × W × H)
Weight~850 g
Alarm TypesLow/High, STEL, TWA
CertificationsCE, RoHS, IP65-rated enclosure
ComplianceDesigned for alignment with ISO 10156, IEC 60079-0/-11 (for intrinsic safety configurations), and applicable regional occupational exposure standards (e.g., OSHA PELs, ACGIH TLVs)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchütz SIGAS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelS-ANALYZER 200 BMBT
Price RangeUSD 5,600–8,400 (FOB)
Response Time<25 s (at 60 L/h stable flow)
Warm-up Time3–30 min (at 20°C, dependent on detector configuration)
O₂ Resolution0.001% (BMBT O₂ channel)
CO/CO₂/CH₄ Resolution0.1 µmol/mol
Display5.6" Touchscreen LCD
Analog Output4–20 mA (normal operation), 2 mA (alarm/preheat)
Digital Outputs6 configurable relay channels (fault, auto-calibration control, concentration high/low alarms)
CommunicationRS232 (DB9 female), RS485 Modbus RTU
Power Supply198–242 V AC, 50/60 Hz, <125 W
Enclosure RatingIP41 (IEC 60529)
Weight~10 kg (net), ~19 kg (packed)
Sample Flow Rate0.2–1.2 L/min (±0.02 L/min stability required)
Sample Temperature5–35 °C
Sample Pressure≤116 kPa (abs)
Sample HumidityNon-condensing
Particulate Load≤100 µg/m³, particle size ≤1 µm
Zero Gas99.999% N₂
Span Gas75–125% of full scale
Mid-point Calibration Gas37.5–62.5% of full scale
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSchütz Measurement & Control / SIGAS
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelSGS-Type Gas Analysis System
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSIGAS
OriginJiangsu, China
ModelS-SYSTEM CEMS
Detection GasesFlue Gas
Accuracy±1% FS
Response TimeT90 < 2 s at 60 L/h flow
Warm-up Time~2 min
Resolution0.01 ppm
Linearity Error≤ ±2% FS to ±5% FS
Zero CalibrationClean Air
Inlet Gas Temperature Range5–30 °C
Display Unitsppm, mg/m³
Output Signals4–20 mA, RS485
Enclosure RatingIP42 (EN 60529)