| Brand | SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SGC-100 CEMS-VOC |
| Pricing | Upon Request |
| Brand | SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | SA-200 TCD |
| Detection Principle | Thermal Conductivity Detection (TCD) |
| Measuring Range | H₂ 0–99.999 vol% (configurable per background gas) |
| Accuracy | ±2% FS |
| Repeatability | ±1% FS |
| Stability | ±1% FS / 7 days |
| Response Time (T90) | <30 s |
| Display | 240×128 LCD |
| Data Storage | SD card (standard), USB flash drive (optional) |
| Output | 4–20 mA (default), configurable to 0–20 mA / 0–1 V / 0–5 V / 0–10 V / 1–5 V |
| Communication | RS485 (standard), RS232 (optional) |
| Power Supply | 85–264 VAC, 50/60 Hz |
| Power Consumption | <35 VA |
| Operating Temperature | –10 to +45 °C |
| Relative Humidity | <80% RH |
| Sample Flow Rate | 200–400 mL/min |
| Sample Pressure | Ambient ±10% (at outlet) |
| Inlet/Outlet Port | 1/4" NPT internal thread, stainless steel |
| Enclosure Dimensions | 483 × 300 × 177 mm (L×W×H) |
| Mounting | Panel mount, cutout 445 × 180 mm (rectangular), fixing holes Φ6 × 4 at 465 × 101.5 mm |
| Brand | SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | S-Handheld 10 |
| Pricing | Upon Request |
| Detection Principles | Infrared (NDIR), Electrochemical, PID, Catalytic Bead |
| Sensor Lifespan | Electrochemical: 2–3 years |
| NDIR | 5–10 years |
| Catalytic Bead | ~3 years |
| PID | 2–3 years |
| Response Time (T90) | ≤60 s |
| Operating Temperature | 5–45 °C |
| Relative Humidity Range | 10–95 %RH (non-condensing) |
| Barometric Pressure Measurement | 300–1100 hPa (±1 hPa accuracy) |
| Power Supply | 5 VDC, rechargeable 6800 mAh Li-ion battery |
| Runtime | Up to 8 h (pump-on continuous operation) |
| Display | 4.3″ TFT-LCD, 800 × 480 resolution |
| Sampling Method | Integrated active pump, 300 mL/min flow rate |
| Filtration | Built-in hydrophobic particulate filter and water trap |
| Data Storage | 100,000 records (concentration + timestamp + alarm flags) |
| Connectivity | USB Type-C (data transfer & charging), optional Bluetooth 5.0 |
| Dimensions | 217 × 92 × 80 mm (L × W × H) |
| Weight | ~850 g |
| Alarm Types | Low/High, STEL, TWA |
| Certifications | CE, RoHS, IP65-rated enclosure |
| Compliance | Designed for alignment with ISO 10156, IEC 60079-0/-11 (for intrinsic safety configurations), and applicable regional occupational exposure standards (e.g., OSHA PELs, ACGIH TLVs) |
| Brand | Schütz SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | S-ANALYZER 200 BMBT |
| Price Range | USD 5,600–8,400 (FOB) |
| Response Time | <25 s (at 60 L/h stable flow) |
| Warm-up Time | 3–30 min (at 20°C, dependent on detector configuration) |
| O₂ Resolution | 0.001% (BMBT O₂ channel) |
| CO/CO₂/CH₄ Resolution | 0.1 µmol/mol |
| Display | 5.6" Touchscreen LCD |
| Analog Output | 4–20 mA (normal operation), 2 mA (alarm/preheat) |
| Digital Outputs | 6 configurable relay channels (fault, auto-calibration control, concentration high/low alarms) |
| Communication | RS232 (DB9 female), RS485 Modbus RTU |
| Power Supply | 198–242 V AC, 50/60 Hz, <125 W |
| Enclosure Rating | IP41 (IEC 60529) |
| Weight | ~10 kg (net), ~19 kg (packed) |
| Sample Flow Rate | 0.2–1.2 L/min (±0.02 L/min stability required) |
| Sample Temperature | 5–35 °C |
| Sample Pressure | ≤116 kPa (abs) |
| Sample Humidity | Non-condensing |
| Particulate Load | ≤100 µg/m³, particle size ≤1 µm |
| Zero Gas | 99.999% N₂ |
| Span Gas | 75–125% of full scale |
| Mid-point Calibration Gas | 37.5–62.5% of full scale |
| Brand | Schütz Measurement & Control / SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | SGS-Type Gas Analysis System |
| Pricing | Upon Request |
| Brand | SIGAS |
|---|---|
| Origin | Jiangsu, China |
| Model | S-SYSTEM CEMS |
| Detection Gases | Flue Gas |
| Accuracy | ±1% FS |
| Response Time | T90 < 2 s at 60 L/h flow |
| Warm-up Time | ~2 min |
| Resolution | 0.01 ppm |
| Linearity Error | ≤ ±2% FS to ±5% FS |
| Zero Calibration | Clean Air |
| Inlet Gas Temperature Range | 5–30 °C |
| Display Units | ppm, mg/m³ |
| Output Signals | 4–20 mA, RS485 |
| Enclosure Rating | IP42 (EN 60529) |