| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GE AKTA Explorer 100 Biological Purification System |
| Operational Age | >10 years |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Operating Temperature | 4–35 °C |
| Relative Humidity | 20–95% (non-condensing) |
| Power Consumption | 1100 W (instrument: 800 W, PC: 300 W) |
| UV Detection Range | –6 to +6 AU |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| Temperature Sensor Range | 0–99 °C (±1.5 °C accuracy, 4–45 °C) |
| pH Sensor Range | 0–14 pH (±0.1 pH accuracy, pH 2–12) |
| Fraction Collector Volume Range | 0.1–50 mL |
| Integrated Pressure Sensors | System pump, sample pump, column inlet, column outlet |
| Integrated Air Bubble Detectors | Sample inlet, Pump A, Pump B |
| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | GE AKTA Explorer |
| Operational Age | >10 Years |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Operating Temperature | 4–35 °C |
| Relative Humidity | 20–95% (non-condensing) |
| Power Consumption | 1100 W (Instrument: 800 W |
| PC | 300 W) |
| UV Detection Range | −6 to +6 AU |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| Temperature Sensor Range | 0–99 °C (±1.5 °C accuracy, 4–45 °C) |
| pH Sensor Range | 0–14 pH (±0.1 pH accuracy, pH 2–12) |
| Fraction Collector Volume Range | 0.1–50 mL |
| Integrated Pressure Sensors | System pump, sample pump, column inlet, column outlet |
| Integrated Air Bubble Detectors | Sample inlet, Pump A, Pump B |
| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AKTA Explorer 100 |
| Operational Age | >10 Years |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Operating Temperature | 4–35 °C |
| Relative Humidity | 20–95% RH (non-condensing) |
| Power Consumption | 1100 W (system: 800 W, PC: 300 W) |
| UV Detection Range | –6 to +6 AU |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| Temperature Sensor Range | 0–99 °C (±1.5 °C accuracy, 4–45 °C range) |
| pH Sensor Range | 0–14 pH units (±0.1 pH accuracy, pH 2–12 range) |
| Fraction Collector Volume Range | 0.1–50 mL |
| Integrated Pressure Sensors | System pump, sample pump, column inlet, column outlet |
| Integrated Air Bubble Detectors | Sample inlet, Pump A, Pump B |
| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | GE AKTA Explorer 100 Protein Purification System |
| Price Range | USD $10,500 – $15,800 (FOB) |
| Operational Age | >10 years |
| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | GE AKTA Explorer 100 |
| Operational Age | >10 years |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | XSeries II ICP-MS (Refurbished) |
| Mass Range | 2–260 amu |
| Sensitivity (Li-7) | 50 Mcps/ppm |
| Sensitivity (Y-89) | 60 Mcps/ppm (XSeries II standard configuration) |
| Sensitivity (Tl-205) | 80 Mcps/ppm |
| Detection Limit (Be-9) | 0.5 ppt |
| Detection Limit (In-115, Bi-209) | 0.1 ppt |
| Oxide Ratio (CeO+/Ce+) | ≤1.5% |
| Doubly Charged Ion Ratio (Ce2+/Ce+) | ≤3.0% |
| Isotopic Ratio Precision (107Ag/109Ag) | RSD ≤0.1% |
| Abundance Sensitivity (low-mass) | 5 × 10⁻⁷ |
| Abundance Sensitivity (high-mass) | 1 × 10⁻⁷ |
| Collision Cell | ORS3™ (He-only mode) |
| High Matrix Tolerance | Up to 3% total dissolved solids (TDS) via HMI technology |
| Software Platform | MassHunter Workstation (QA/QC, audit trail, automated method execution) |
| Brand | Pharma-test |
|---|---|
| Origin | USA |
| Model | PTWS 1420 |
| Configuration | Dual-motor independent paddle/stirrer control |
| Test Stations | 14 dissolution vessels + 2 auxiliary heating/medium reservoir vessels |
| Compliance | USP <711>, <724>, EP 2.9.3 & 2.9.4, BP, DAB, JP 15 |
| Temperature Monitoring | Individual cup-level ITM sensors |
| Automated Sampling | EPE robotic arm with precise Z-axis immersion and positioning |
| Dosing | TMA automatic tablet/capsule drop module |
| Drive System | Monoshaft™ single-shaft universal adapter for USP Apparatus 1 (basket), 2 (paddle), 5 (paddle-over-disk), and 6 (cylinder) |
| Method Storage | Unlimited protocols via SD card |
| Calibration & Qualification | Built-in OQ/PQ reminder, pre-run self-diagnostic (optical + audible feedback) |
| Fluid Handling | DSR-M 13-channel piston pump with LCD display, 20-sample capacity, HPLC vial/tube rack compatibility |
| Thermal System | 1500 W rapid-heating water bath with removable tank, diffuser-assisted uniformity, low-volatility vessel lids |
| Connectivity | USB remote control, RS232 printer interface |
| Acoustic Design | Low-noise, vibration-damped recirculating pump |
| Software Features | User management, method management, stepwise manual start, audit-ready event logging |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Mass Range | m/z 10–2000 |
| Ionization Sources | ESI & APCI |
| Scan Modes | Full Scan, SIM, MRM |
| MRM Acquisition Rate | Up to 1000 transitions/sec |
| Dynamic Range | 10⁶–10⁷ |
| Detection Limit | Low pmol/L (ESI-MRM) |
| Software | MassLynx v4.2 or later |
| Compliance | Designed for GLP/GMP environments |
| Typical Service Life | 3–5 years (verified operational history, full service logs available upon request) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Operational Age | 4–5 years |
| Configuration | Standard GC system with integrated 7683 autosampler control |
| Regulatory Readiness | Built-in 21 CFR Part 11 compliance features (audit trail, electronic signature support, user access levels) |
| Detection Options | FID, TCD, µECD, NPD, MSD, ICP-MS, and optional PFPD, SCD, AED via Agilent partner ecosystem |
| Injection Modes | Split/splitless (0–100 psi & 0–150 psi), packed column, on-column, PTV, and volatile analysis interface |
| Data Systems | Compatible with Agilent ChemStation Plus (ChemStore C/S, ChemAccess), PetroQA/QC Cerity NDS |
| Speed Capability | Fast GC mode (up to 10× faster than conventional GC) |
| Sample Introduction | Supports headspace, purge-and-trap, valve injection, and large-volume injection (LVI) without pre-concentration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agilent 6890N (Refurbished) |
| Price Range | USD 4,200 – 11,200 |
| Detector | FID (Detection Limit: <5 pg C/s on propane) |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Split/Splitless Injector Pressure Range | 0–100 psi (optional 0–150 psi) |
| Total Flow Range (Split/Splitless) | 0–200 mL/min N₂, 0–1000 mL/min H₂ or He |
| Autosampler | Integrated Agilent 7683 Control |
| GC Speed | Up to 10× faster than conventional GC |
| Compliance | Designed for ASTM D3606, D5186, ISO 6416, USP <621>, FDA 21 CFR Part 11-ready configurations available |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Agilent VK7025 Dissolution Tester |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Instrument Age | 4–5 years |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Service Provider |
| Product Category | Imported Instrument |
| Model | 6890/7890/8890 Qualification Services |
| Price Range | USD 10,500–20,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Pharmaceutical Analysis |
| Oven Temperature Range | 0–500 °C |
| Oven Ramp Rate | 0–100 °C/min |
| Oven Cool-down Rate | 0–100 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 psi |
| Inlet Maximum Operating Temperature | 450 °C |
| Inlet Pressure Setting Range | 0–970 psi |
| Inlet Total Flow Setting Range | 0–1200 mL/min |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | iCAP 6000 |
| Optical System | Echelle grating with cross-disperser |
| Spectral Range | 166–847 nm |
| Resolution | High spectral resolution for trace analysis in complex matrices |
| Detector | High-sensitivity CCD |
| RF Generator | 27.12 MHz solid-state |
| Power Range | 750–1500 W (adjustable) |
| Cooling | Air or water cooling |
| Nebulizer | Concentric or optional ultrasonic |
| Spray Chamber | Chemically resistant (e.g., PTFE) |
| Peristaltic Pump | 4-channel, flow-rate adjustable |
| Sample Throughput | As low as 30 s per sample |
| Detection Limits | Sub-ppb (element-dependent) |
| Linear Dynamic Range | 6–7 orders of magnitude |
| Precision | RSD < 2% |
| Software | Thermo Scientific iTEVA |
| Compliance | 21 CFR Part 11 ready |
| Dimensions | ~700 × 650 × 600 mm |
| Weight | ~80 kg |
| Power Supply | 200–240 V, 50/60 Hz |
| Operating Environment | 15–30 °C, <80% RH (non-condensing) |
| Brand | Pharma-test |
|---|---|
| Origin | USA |
| Model | PTWS 1420 |
| Configuration | Dual-drive, 14-vessel dissolution system with independent paddle/stirrer speed control per side |
| Compliance | Fully compliant with USP <711>, <724>, EP <2.9.3>, <2.9.4>, BP, DAB, and JP <15> |
| Vessel capacity | 14 test positions + 2 auxiliary temperature-controlled media reservoirs |
| Temperature monitoring | Individual cup-level ITM sensors (±0.2 °C accuracy) |
| Automated dosing | TMA tablet drop module |
| Sampling system | EPE robotic autosampler with precise XYZ positioning and immersion depth control |
| Drive architecture | Monoshaft™ single-shaft design for seamless USP Apparatus 1 (basket), 2 (paddle), 5 (paddle-over-disk), and 6 (cylinder) interchangeability without re-heighting |
| Method storage | Unlimited methods via SD card with user-accessible encryption and audit trail metadata |
| Pump system | DSR-M 13-channel piston pump with LCD interface, 20-sample programmable sequence, compatible with standard HPLC vials and tube racks (2–20 mL) |
| Water bath | 1500 W rapid-heating stainless-steel bath with detachable design, integrated diffuser for ±0.1 °C thermal uniformity across all vessels |
| Acoustic & vibration performance | Low-noise circulation pump with anti-vibration mounting |
| Pre-run diagnostics | Integrated self-test with visual LED indicators and audible status tones |
| Qualification support | Built-in OQ/PQ checklist prompts and timestamped event logging |
| Connectivity | USB host for PC remote operation |
| Safety & ergonomics | Low-volatility vessel lids, step-start manual mode, dual-motor left/right independent drive control |
| Software compliance | Audit-trail-enabled method execution logs meeting FDA 21 CFR Part 11 requirements for electronic records and signatures |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | TQD |
| Mass Range | m/z 10–2000 |
| Ionization Sources | ESI & APCI |
| Scan Modes | Full Scan, SIM, MRM |
| MRM Transition Rate | Up to 1000 transitions/sec |
| Dynamic Range | 10⁶–10⁷ |
| Detection Limit | Low pmol/L (ESI) |
| Software | MassLynx v4.2 or later |
| Compliance | ASTM D7598, USP <1225>, FDA 21 CFR Part 11 (with audit trail enabled) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Third-Party Service Provider |
| Product Category | Imported Instrumentation |
| Model | Agilent 1100/1200/1360 HPLC 3Q Qualification Package |
| Price Range | USD 11,000–20,500 (FOB) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical Use |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Operating Pressure | 40 MPa |
| Flow Accuracy | < ±0.1% RSD |
| Injection Volume Range | 1–50 µL |
| Autosampler Tray Capacity | 100 positions |
| Column Oven Temperature Range | 10–60 °C |
| UV-Vis Detector Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Instrument Age | 4–5 years |
| Configuration | Includes integrated Agilent 7683 autosampler control |
| Detector Options | FID, TCD, µECD, NPD, MSD, ICP-MS, FPD (upgraded), plus optional SCD, PFPD, AED via Agilent Partners |
| Inlet Types | Split/splitless (0–100 psi & 0–150 psi), packed column, on-column, PTV, VOA |
| Software Compatibility | Agilent ChemStation Plus (ChemStore C/S, ChemAccess), Cerity QA/QC for Petrochemicals |
| Regulatory Compliance | Supports 21 CFR Part 11 audit trails, GLP/GMP data integrity requirements |
| GC Speed | Capable of fast GC operation (up to 10× faster than conventional GC) |
| Sample Introduction | Large-volume injection (LVI) enabled, headspace, purge-and-trap, valve-based injection modules available |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7697A |
| Sample Capacity | Up to 111 vials (auto-sampler mode) |
| Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Oven Temperature Range | Ambient to 200 °C |
| Transfer Line & Valve Temperature Range | Ambient to 200 °C |
| Injection Mode | Six-port valve with fixed-volume loop |
| Carrier Gas Control | Electronic Pressure Control (EPC) for He, N₂, H₂ |
| Software Compatibility | Agilent OpenLAB CDS and ChemStation |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Second-hand Dissolution Testing System |
| Model | VK7025 |
| Age | 4–5 years |
| Regulatory Compliance | USP <711>, EP 2.9.3, JP XVII, ChP 0931 |
| Sample Capacity | 6-vessel |
| Vessel Configurations | Basket (USP Apparatus 1) & Paddle (USP Apparatus 2) |
| Temperature Control | Independent vessel-level PT100 probes with ±0.2 °C accuracy |
| Automation Features | Motorized sampling arm, programmable DDM (Drug Delivery Module), TruCenter™ magnetic cup alignment, dome-shaped anti-evaporation lids |
| Software Compatibility | Agilent Dissolution Workstation (FDA 21 CFR Part 11 compliant with audit trail, electronic signature, and user access control) |
| Brand | Distek |
|---|---|
| Origin | USA |
| Model | 6100 |
| Vessel Positions | 6 (optional 7 or 8) |
| Volume Range | 100–4000 mL |
| Speed Range | 25–300 rpm |
| Speed Resolution | 0.1 rpm |
| Speed Accuracy | ±0.2 rpm |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.25 °C |
| Touchscreen Interface | Full-color graphical LCD |
| Automation Features | Auto-height adjustment, DDS (Drug Delivery System), TCS (Thermostatic Circulation System), electronic validation reminder, user access control (50 users), method library (100 methods), report history (100 latest) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Waters SQD |
| Mass Range | m/z 50–1000 |
| Ionization Sources | ESI and APCI |
| Detection Modes | Full Scan, SIM, SIR |
| Software | MassLynx v4.2 or later |
| Dynamic Range | 10⁶–10⁷ |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole GC-MS |
| Configuration | Standalone Mass Spectrometer (requires compatible Agilent GC, e.g., 7890B/7820A) |
| Detection Principle | Electron Ionization (EI) and Chemical Ionization (CI) |
| Mass Range | 10–1000 m/z |
| Scan Speed | Up to 20,000 Da/sec in MRM mode |
| Sensitivity | <10 fg OFN (octafluoronaphthalene) in EI MRM mode |
| Mass Resolution | Unit mass resolution (0.7 Da at peak apex) |
| Vacuum System | Dual-stage turbomolecular pump (≥260 L/s for MS region) |
| Interface Temperature | Up to 350 °C |
| Data System Compatibility | Agilent MassHunter Workstation (vB.08.00 or later) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UPLC + Xevo TQD |
| Price Range | USD $26,000 – $39,000 (FOB) |
| Operational Age | 3–5 years |