| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AbioWelder™ 100 |
| Pricing | Upon Request |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | AppliAsep Aseptic Sampling System |
| Pricing | Available Upon Request |
| Brand | Applitech |
|---|---|
| Model | Countleader FL 100 |
| Detection Principle | Digital Imaging Cytometry with Dual-Channel Fluorescence (470/525 nm & 535/617 nm) |
| Sample Volume | 15 µL per well |
| Throughput | Up to 8 samples simultaneously |
| Analysis Modes | Brightfield, Trypan Blue Exclusion, AO/PI Dual-Fluorescence, GFP/RFP Transfection Efficiency |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready |
| Consumable | Proprietary FL8-slide (8-well, single-use) |
| Software | Integrated image analysis platform with audit trail, electronic signature, and 3Q validation support |
| Data Output | PDF, Excel, TIFF |
| User Management | Three-tier role-based access control (Administrator, Operator, Viewer) |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Countleader FL 1000 |
| Pricing | Upon Request |
| Brand | Applitech |
|---|---|
| Model | d-Control |
| Architecture | Open-architecture DeltaV™-based control platform |
| Compliance | Designed for cGMP, FDA 21 CFR Part 11-ready environments |
| Scalability | Supports up to 32 bioreactors per system |
| Integration | OPC UA/DA compliant |
| Data Export | Native Excel-based reporting via DeltaV Historian |
| Alarm Management | Priority-ranked, timestamped, SMS-enabled alerting |
| Deployment Scope | Lab-scale → Pilot-scale → GMP manufacturing |
| Third-party Compatibility | Full integration with MES, LIMS, and ERP systems |
| Brand | Applitech |
|---|---|
| Origin | Germany |
| Manufacturer | Cytena GmbH (distributed by Applitech) |
| Product Type | Imported |
| Model | F.SIGHT 2.0 |
| Pricing | Upon Request |
| Brand | Applitech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Liquid Dispensing System |
| Pricing | Upon Request |
| Brand | Appliteh |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Origin | Domestic (China) |
| Model | AbioFill V100 |
| Pricing | Upon Request |
| Fill Volume Range | 250 µL – 5 mL |
| Fill Speed | 350–800 µL/s |
| Accuracy | ±<5% volumetric error |
| Cell Viability Deviation | <2% (across 24 vials) |
| Live Cell Concentration Deviation | <5% |
| Vial Capacity per Batch | Up to 24 cryovials (in multiples of 4) |
| UV Sanitization Option | Optional integrated UV-C module with software control |
| Compliance | Designed for GMP environments with audit trail, multi-level user permissions, and 21 CFR Part 11–ready data integrity architecture |
| Brand | Appliteh |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Origin | Domestic (China) |
| Model | AppliAsep Sterile Sampling System |
| Pricing | Available Upon Request |
| Brand | ARALAB |
|---|---|
| Model | FitoClima 600 |
| Internal Volume | 600 L |
| Temperature Range | −5 °C to +45 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±1.0 °C (at setpoint) |
| Temperature Fluctuation | ±0.5 °C (1σ) |
| Humidity Range | 20–95% RH |
| Humidity Uniformity | ±2% RH |
| Humidity Fluctuation | ±0.5% RH (1σ) |
| Shelf Dimensions | 630 mm × 510 mm |
| Shelf Load Capacity | 18 kg per shelf |
| Standard Shelves | 4 stainless steel shelves |
| Max. Shelves | 10 |
| Total Standard Shelf Area | 1.33 m² |
| External Dimensions (H×W×D) | 1980 × 745 × 950 mm |
| Net Weight | 175 kg |
| Power Supply | 1/N/PE, 230 V ±10%, 50 Hz, 16 A |
| Water Supply | Deionized or distilled water, 1–5 bar, conductivity <40 μS/cm |
| Brand | ARALAB |
|---|---|
| Model | FitoClima 600 PLH / FitoClima 1200 PLH |
| Temperature Range | 5°C to +45°C (±0.1°C) |
| Humidity Range | 40–90% RH (±0.1% RH) |
| Light Intensity | 0–300 µmol/m²·s (up to 21,500 Lux) |
| Internal Volume | 600 L / 1200 L |
| Illumination Type | White LED or Fluorescent Plant-Growth Lighting |
| Temperature Uniformity | ±1.0°C |
| Humidity Uniformity | ±2% RH |
| Airflow Control | 1–100% adjustable (0.3–1 m/s) |
| Compliance | EN 60068-3-5, IEC 61000-6-3, EMC 2004/108/EC, MD 2006/42/CE, LVD 2006/95/CE, EN 14509-CPR 305/2011/EU, EN 13823:2010+A1:2014 |
| Brand | Arctiko |
|---|---|
| Origin | Denmark |
| Model | LTFE110 / LTFE210 / LTFE290 / LTFE310 / LTFE370 / LTFE410 / LTFE510 |
| Temperature Range | −10 °C to −45 °C |
| Total Volume | 130–416 L |
| External Dimensions (W×D×H) | 725–1705 × 655 × 865 mm |
| Display | Digital LED |
| Alarm System | Visual & Audible, Remote Alarm Output |
| Interior | Adjustable Wire Baskets, Pull-Out Defrost Tray |
| Mobility & Security | Casters with Locks |
| Cabinet Finish | White Powder-Coated Steel |
| Energy Efficiency | Optimized Refrigeration Cycle |
| Compliance | CE, IEC 61010-1, IEC 60335-2-24 |
| Brand | Arctiko |
|---|---|
| Origin | Denmark |
| Model | ULTF Series |
| Temperature Range | –40 °C to –85 °C |
| Compressor Configuration | Single-stage |
| Control System | Digital microprocessor controller with 72-hour battery backup |
| Alarm System | Remote audible/visual alarm with CO₂ support option |
| External Dimensions (W×D×H, mm) | ULTF 80 — 552×648×850 |
| Total Volume (L) | ULTF 80 — 71 |
| Energy Efficiency | Optimized low-power design |
| Noise Level | <55 dB(A) at 1 m |
| Footprint | Compact horizontal configuration |
| Brand | Argus |
|---|---|
| Origin | Germany |
| Model | PiCUS-3 |
| Sensor Count | 6 or 12 |
| Sensor Cable Length | 3.5 m |
| Measurement Principle | Elastic Wave Propagation Time-of-Flight Tomography |
| Spatial Resolution | 1 µs time resolution |
| Operating Battery Life | >6 h |
| Charging Time | 2 h |
| GPS Accuracy | 0–20 m |
| Display | Color LCD (real-time tomographic visualization) |
| Data Transfer | USB 2.0 or Bluetooth (range: 0.5–10 m) |
| Dimensions | 55 × 42 × 13 cm |
| Weight | 8.9 kg |
| Integrated Height Measurement | Yes |
| Optional Electronic Caliper Range | 160–2150 mm (stainless steel) |
| Brand | Argus |
|---|---|
| Origin | Germany |
| Model | TMS3 |
| Weight | 73 g |
| Dimensions | 61 mm × 41 mm × 20 mm |
| IP Rating | Fully Sealed, Waterproof & Dustproof |
| Tilt Measurement Accuracy | ±0.03° |
| Sampling Frequency | 20 Hz (50 ms interval) |
| Measurement Axes | 3D (X/Y/Z, cardinal directions) |
| Operating Temperature Range | −20 °C to +50 °C |
| Battery Capacity | 250 mAh |
| Continuous Operation | >15 days |
| Charging | Wireless (Qi-compatible) |
| Data Storage | 256 MB (≈20 days at 20 Hz) |
| Communication | Bluetooth 2.1 |
| Sensor Mounting | Omnidirectional |
| Control Sensor Height | 2–3 m above ground |
| Base Sensor Placement | At root collar / anchorage zone |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 100 |
| Certification | ISO 13485:2016 (Manufacturing Site, Edinburgh, Scotland) |
| Technology | Non-contact Piezoelectric Inkjet Dispensing |
| Throughput | >10,000 Unique Spots per Second |
| Minimum Dispense Volume | Sub-nanoliter (typ. 0.1–2.0 nL) |
| Spot Precision | ≤ ±5 µm positional accuracy |
| Compatible Substrates | Glass slides, silicon wafers, membranes, polymer films, functionalized surfaces |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 100 |
| Spotting Method | Non-contact piezoelectric inkjet |
| Spot Volume Range | picoliter to nanoliter (pL–nL) |
| Spotting Speed | 711 spots per second |
| Substrate Capacity | 6 × SBS-format microtiter plates or 100 standard microscope slides |
| Repeatability (CV) | < 5% |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO 13485 and ASTM E2519-22 reference practices for microarray fabrication |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 100-S |
| Spotting Method | Non-contact piezoelectric inkjet |
| Spotting Speed | 711 spots/second |
| Substrate Capacity | 48 × SBS-format microplates or 100 × standard microscope slides (76 × 26 mm) |
| Spot-to-spot Precision | CV < 5% |
| Dispense Volume Range | picoliter to nanoliter |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO 13485 and ASTM E2578-07 (Standard Guide for Microarray Processing) |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 1000 |
| Spotting Method | Non-contact piezoelectric inkjet |
| Spot Volume Range | picoliter to nanoliter (pL–nL) |
| Spotting Speed | 711 spots per second |
| Substrate Capacity | 6 × SBS-compliant microtiter plates or 1,000 standard microscope slides |
| Repeatability (CV) | < 5% |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO 13485 and ASTM E2539-22 reference practices for microarray fabrication |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 1000-S |
| Spotting Method | Non-contact piezoelectric inkjet |
| Spot Volume Range | picoliter to nanoliter (pL–nL) |
| Spotting Speed | 711 spots per second |
| Substrate Capacity | 48 SBS-format microplates or 1,000 standard microscope slides |
| Positional Reproducibility | CV < 5% |
| Compliance | CE-marked, ISO 13485–compatible workflow design |
| Brand | Arrayjet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 100S |
| Spotting Type | Non-contact inkjet |
| Spot Volume Range | 40 pL to 10 nL |
| Certification | ISO 13485:2016 (Manufacturing Site, Edinburgh, UK) |
| Brand | ArrayJet |
|---|---|
| Origin | United Kingdom |
| Model | Mercury 25 |
| Spotting Method | Non-contact piezoelectric inkjet |
| Number of Parallel Nozzles | 128 |
| Spotting Speed | 711 spots per second |
| Substrate Capacity | 1 × SBS-standard microplate or 25 × standard microscope slides (76 × 26 mm) |
| Spot-to-Spot Reproducibility | CV < 5% |
| Environmental Control | Integrated humidity and temperature regulation with evaporation suppression |
| Brand | Artemis |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | MARS |
| Instrument Category | Optical In Vivo Imaging System |
| Camera | Teledyne Princeton Instruments NIRvana Series |
| Optical Configurations | FAST (Wide-Field Acquisition) & Pathfinder (High-Resolution Targeted Imaging) |
| Modularity | Fully Modular Platform for Multimodal Integration |
| Sample Capacity | Single-animal positioning stage (mouse/rat compatible) |
| Dye Compatibility | Water-soluble D-A-D small-molecule NIR-II fluorophores (e.g., QY ≈ 1.2% at ~1000–1700 nm) |
| Brand | Artemis |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Artemis Medical Technology Co., Ltd. |
| Model | MARS Series |
| Instrument Type | Optical In Vivo Imaging System |
| Spectral Range | 400–1700 nm |
| Penetration Depth | >15 mm |
| Spatial Resolution | <3 µm |
| Fluorescence Lifetime Resolution | <5 µs |
| Frame Rate | >1000 fps |
| Multimodal Options | X-ray, CT, FLIM, NIR-I, Hyperspectral In Situ Imaging, Photothermal Therapy Module |
| Sample Capacity | Single-animal (mouse/rat) positioning stage |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Artemis |
|---|---|
| Model | MARS |
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Imaging Modalities | Fluorescence (400–900 nm), X-ray, Computed Tomography (CT) |
| Category | Optical & Multimodal Preclinical Imaging System |
| Regulatory Classification | Class II Medical Device (China NMPA), CE-marked for research use only (RUO) |
| Brand | Artemis |
|---|---|
| Model | MARS-Full Spectrum |
| Imaging Modalities | Multispectral Fluorescence (400–1700 nm), X-ray, CT |
| Spectral Range | 400–900 nm (Visible–NIR-I), 900–1700 nm (NIR-II/SWIR) |
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Optical In Vivo Imaging System |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Artemis |
|---|---|
| Model | MARS-NANO |
| Type | Research-Grade Fluorescence Microscope |
| Excitation Range | 400–1700 nm |
| Optical Architecture | Upright, Modular (Confocal, Two-Photon, Hyperspectral) |
| Primary Application Domain | Small-Animal In Vivo Imaging |
| Regulatory Classification | Non-Medical Device |
| Origin | Shanghai, China |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Co., Ltd. |
| Type | Imported Instrument |
| Model | AS ONE Cell Picking System |
| Separation Method | Fully Automated Microfluidic Single-Cell Isolation |
| Cell Viability | 60–90% |
| Chip Format | Array of >100,000 Microwells (Ø ≈ 10 µm) |
| Detection Mode | Fluorescence Intensity + Brightfield Imaging |
| Recovery Mechanism | Glass Capillary-Based Contact-Free Aspiration |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | CM-191 |
| Measurement Principle | Antimony Electrode Potentiometry (pH 4.00–9.00) & Glass Electrode Potentiometry (pH 0.00–14.00) |
| Temperature Compensation | Automatic/Manual (0°C to 100°C) |
| Input Impedance | >10¹³ Ω |
| Resolution | 0.01 pH / 1 mV |
| Accuracy (pH) | ±0.01 pH |
| Accuracy (mV) | ±1 mV |
| Display | Digital LCD |
| Power Supply | AC 100 V, 50/60 Hz (12 V DC adapter) |
| Power Consumption | ~1 VA |
| Dimensions (W×D×H) | 165 × 180 × 70 mm |
| Weight | ~1000 g |
| Data Output | 0–1.4 V analog signal (compatible with external data loggers) |
| Standard Accessories | pH 4.01 & 6.86 calibration buffers (1× each), 12 V AC adapter, 0–100°C thermometer |
| Optional Electrodes | CMS-191 antimony micro-catheter electrode (1.0 mm OD), CM-181 glass electrode (2.4 mm OD) |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Co., Ltd. |
| Model | C3-6653-01 |
| Instrument Type | Power Supply-Integrated Horizontal Electrophoresis Apparatus |
| Operating Voltage | 35 / 50 / 100 V DC (selectable, fixed-step) |
| Safety Interlocks | Lid-open detection, no-buffer sensing, overcurrent cutoff |
| Dimensions (W × D × H) | 190 × 130 × 55 mm |
| Power Input | 100 V AC (Japan standard) |
| Compliance | JIS T 0601-1, IEC 61010-1 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use) |