Life Science Instruments
Filter
Showing 31–60 of 2744 results
| Brand | ACE GIKEN |
|---|---|
| Origin | Japan |
| Material | SUS314 stainless steel |
| Sterilization Method | Vacuum-compatible |
| Maximum Working Pressure | 0.5 MPa |
| Volume Capacity | 1.8 L |
| Mounting Type | Top-discharge (BU series) |
| Compliance | Designed for pharmaceutical and biotech cleanroom environments |
| Customization Options | Level sensors, residual volume detection, agitators (25 W / 40 W), sight glasses, LCD indicators |
| Brand | ACE GIKEN |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Atom Ace 100 Complete System |
| Material | SUS314 Stainless Steel |
| Sterilization Method | Vacuum Sterilization |
| Compatible Container Sizes | 1 kg, 3 kg, Cartridge, and Drum Formats |
| Control Interface | DPC-800C / DPC-800CDX Controller |
| High-Pressure Valve | BP-109 Series Balpet Valve |
| Tubing | Polyurethane Tubing (φ4×φ2.5×2m ×2 pcs |
| Nozzles | 20 pcs Metal Nozzles (Customizable Orifice Sizes) |
| Mounting Kit | 3-Piece Stand Assembly (Base, Vertical Rod, Nozzle Holder) |
| Brand | ACE GIKEN |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CT-10 |
| Price | USD 1,850 (excl. tax & shipping) |
| Material | SUS314 Stainless Steel |
| Sterilization Method | Vacuum Sterilization |
| Brand | ACE GIKEN |
|---|---|
| Model | DPS-110ⅢL |
| Origin | Japan |
| Construction Material | SUS314 Stainless Steel |
| Sterilization Method | Vacuum Sterilization |
| Compliance | Designed for ISO 13485-aligned bioprocessing environments |
| Fluid Path Architecture | Modular, serviceable screw-valve assembly with replaceable bushing |
| Drive Mechanism | Precision stepper-motor-controlled screw rotation |
| Max. Dispense Volume | ~10× higher than SB-110ⅢS reference model |
| Maintenance Interface | Lock-nut coupling between wetted and drive sections |
| Included Components | SA-110ⅢL controller, foot switch, PU tubing (φ4×φ2.5×2m ×2 |
| Brand | ACE GIKEN |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DPS-800SPⅡ |
| Housing Material | SUS314 Stainless Steel |
| Sterilization Method | Vacuum Sterilization |
| Control Architecture | Microprocessor-Based Dual-Parameter Independent Adjustment (Liquid Pressure, Atomizing Air Pressure, Dispense Duration) |
| Valve Core Technology | Balpet® Precision Metering Valve Platform |
| Integration Interface | TTL/24 VDC I/O Terminals |
| Hose Compatibility | PU Tubing (φ4×φ2.5 mm, φ6×φ4 mm), Nylon Tubing (φ8×φ6 mm) |
| Nozzle Options | Interchangeable Internal/External Atomization Nozzles (Custom Sizing Available) |
| Regulatory Compliance | Designed for ISO 13485-aligned bioprocess environments |
| Sterility Assurance | Compatible with vacuum-based depyrogenation and terminal sterilization protocols |
| Brand | ACE GIKEN |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NS-1MD |
| Material | SUS314 Stainless Steel |
| Sterilization Method | Vacuum-Compatible Design |
| Maximum Workpiece Diameter (Horizontal) | φ200 mm |
| Maximum Workpiece Diameter (Angled Mode) | φ60 mm |
| Maximum Swivel Diameter (Horizontal) | φ230 mm |
| Maximum Swivel Diameter (Angled Mode) | φ100 mm |
| Maximum Workpiece Height | 45 mm |
| Maximum Workpiece Weight | 4 kg |
| Applicable Viscosity Range | 1–100,000 cP |
| Nozzle Stroke | 50 mm |
| Adapter Rotation Speed | 0–120 rpm (variable) |
| Angular Adjustment Range | 0°–30° |
| Oven Clearance Height | 50–110 mm |
| Positioning Accuracy (Radial Runout) | ±0.2 mm |
| Process Cycle Time | ≤2 s per deposition point |
| Power Supply | AC 100 V, 50/60 Hz |
| Operating Air Pressure | 0.4–0.5 MPa (dry air) |
| Net Weight | ~25 kg |
| Brand | ACE GIKEN |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NS-1MXIII |
| Housing Material | SUS314 Stainless Steel |
| Sterilization Method | Vacuum-Compatible Design |
| Maximum Workpiece Diameter | φ100 mm |
| Maximum Workpiece Height | 50 mm |
| Weight Capacity | 1 kg |
| Rotary Runout Precision | ±0.1 mm |
| Vertical Stroke (Dispenser) | 50 mm (Pneumatic Cylinder) |
| Rotational Speed Range | 7.2–112 rpm (50 Hz) / 7.2–128 rpm (60 Hz), Digital Control |
| Dispenser Tilt Angle Adjustment | 0–30° (Manual) |
| Micro-Positioning Range (Vertical) | 0–25 mm (Micrometer-Driven) |
| Horizontal (Radial) Adjustment Range | 0–50 mm |
| Power Supply | AC 100 V, 50/60 Hz |
| Air Supply Pressure | 0.4–0.5 MPa (Dry Compressed Air) |
| Standard Accessories | Digital Timer, Tachometer, Interchangeable Workholding Adapters |
| Brand | ACE GIKEN |
|---|---|
| Origin | Japan |
| Model | SL900-GP |
| Construction Material | SUS314 Stainless Steel |
| Sterilization Method | Vacuum Sterilization |
| Compliance | Designed for Aseptic Bioprocessing Environments |
| Application Domain | Cell Culture Reactor Feed Control, High-Viscosity Biopolymer Delivery, Precision Peristaltic-Alternative Dosing |
| Brand | ACE GIKEN |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TC-100 / TC-250 / TC-150C |
| Material | SUS314 Stainless Steel |
| Sterilization Method | Vacuum Sterilization |
| Cartridge Capacity | 100 g, 150 g, 250 g |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ACM-200+ |
| Pricing | Available Upon Request |
| Brand | Flownamics |
|---|---|
| Origin | USA |
| Model | Acquire |
| Temperature Range | –10 °C to 20 °C |
| Sample Input Streams | Up to 8 |
| Compatible Vessels | Microplates (96-/384-well), Tubes (up to 50 mL) |
| Sterile Sampling Interface | Yes |
| Cooling Method | Peltier and/or Cryogenic Coolant |
| Remote Control | OPC UA-compatible |
| Footprint | Compact, Dual Configurations Available |
| Brand | ACST |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NanoFab |
| Price | USD 200,000 |
| Instrument Category | Microarray Fabrication System |
| Substrate Material | Silicon |
| Substrate Dimensions | 2 cm × 2 cm |
| Feature Size | 5 µm |
| Probe Anchoring Method | Atomic Stamp (Soft Lithography-Based) |
| Compatible Sample Types | Nucleic Acids, Proteins |
| Brand | ACST |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | NLP-2000 |
| Price | USD 200,000 |
| Instrument Type | Microarray Chip System |
| Footprint | 4 cm × 4 cm × ~18 cm (H) |
| Substrate Compatibility | Silicon, SiO₂, Silanized Glass, Amine-Activated Slides, Metals, PDMS, Hydrogels, Polystyrene, Catalysts, Thiols |
| Minimum Feature Size | 10 nm |
| Patterning Method | Direct-Write Dip-Pen Nanolithography (DPN) |
| Printable Materials | Proteins, DNA/RNA, Antigens, Liposomes, Nanoparticles, Polyethylene Glycol (PEG), UV-Curable Polymers, Thermoset Polymers, Glycerol, Silanes |
| Viscosity Range | 1–20,000 cP |
| Print Area | 40 mm × 40 mm |
| Resolution | Sub-100 nm lateral, <5 nm height control |
| Probe Array Configurations | Single-tip to M-type multi-tip (up to 128 tips) |
| Environmental Control | Integrated Humidity & Temperature Chamber (±0.1 °C, ±2% RH) |
| Motion Stages | Piezoelectric XYZ linear stages + dual-axis goniometer (Tx/Ty) |
| Imaging | High-resolution optical microscope (10×–100×, 0.7 µm resolution) |
| Software | ACST NanoPattern Suite v4.2 (Scriptable, GLP-compliant audit trail, FDA 21 CFR Part 11 optional) |
| Brand | Active Spectrum |
|---|---|
| Origin | USA |
| Model | CM-1000 |
| Measurement Principle | Dual-wavelength (700 nm & 840 nm) reflectance-based relative chlorophyll index |
| Measurement Area | 1.35 cm Ø at 30.5 cm distance |
| Effective Measurement Range | 0–999 (unitless relative chlorophyll index) |
| Repeatability | ±5% of reading |
| Measurement Interval | 2 seconds per reading |
| Detector | Four photodiodes (2 for sample reflectance, 2 for ambient light compensation) |
| Data Storage | 1,350 records with GPS metadata |
| Power | Two AAA alkaline batteries (~3,000 measurements per set) |
| Operating Distance Range | 30.5 cm to 183 cm |
| Weight | Handheld, lightweight ergonomic design |
| Environmental Compensation | Automatic ambient light correction |
| Connectivity | Optional GPS integration via serial interface |
| Compliance | Designed for field-deployable agronomic and ecological monitoring in accordance with ISO 11097 (optical plant sensors), ASTM E2912 (standard practice for spectral reflectance measurements of vegetation), and GLP-aligned data integrity workflows |
| Brand | ACV |
|---|---|
| Model | BloFlu 96/96Pro |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well and 384-well formats |
| Heating Rate | 5°C/s |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.3°C |
| Excitation/Detection Technology | Fixed-Optics Light-Path System (Patented “Light-Shuttle” Architecture) |
| Calibration | Factory-Pre-Calibrated for All Fluorescence Channels |
| Control Interface | Integrated Touchscreen with Real-Time Signal Monitoring |
| Data Handling | Automated Data Transfer and On-Device Analysis |
| Thermal Gradient Function | Programmable Linear Gradient Across Block (Spanning up to 30°C) |
| Brand | ACV |
|---|---|
| Origin | Shandong, China |
| Model | MoleDete C |
| Instrument Type | Gradient Thermal Cycler |
| Sample Throughput | Interchangeable reaction modules including 96×0.2 mL gradient single-block, 96×0.2 mL / 48×0.5 mL gradient deep-well block, dual 48×0.2 mL gradient block, 384-well single-block gradient module, and qPCR gradient module |
| Max Heating/Cooling Rate | 5 °C/sec (with optional rapid module) |
| Temperature Accuracy | ±0.2 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C (within 10 sec at 90 °C) |
| Brand | ACV |
|---|---|
| Origin | Shandong, China |
| Model | NuacGel Series |
| Instrument Type | Standard Gel Imaging System |
| Electrophoresis Module | Horizontal Benchtop Unit with Dual-Side Casting Platform |
| Imaging Module | Compact CMOS-Based UV/Visible Gel Documentation System |
| Power Supply | Programmable Constant Voltage/Constant Current Source with Real-Time Monitoring and Multi-Step Method Support |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory workflows |
| Safety Features | Interlocked transparent chamber, UV shielded viewing window, emergency stop button, automatic power cutoff on lid opening |
| Sample Throughput | Up to four 70 mm × 70 mm or two 70 mm × 70 mm + two 70 mm × 100 mm gels simultaneously |
| Imaging Sensor | High-sensitivity monochrome CMOS sensor with adjustable exposure and auto-focus optics |
| Software | Image Lab Touch™ embedded interface with automated capture, background subtraction, band intensity quantification, molecular weight estimation, and export-ready TIFF/PNG/JPEG output |
| Brand | ACV |
|---|---|
| Origin | Shandong, China |
| Model | ProLux Series |
| Instrument Type | WB Imaging & Processing System |
| Automation Level | Fully Automated |
| Transfer Method | Wet Transfer |
| Maximum Gel Capacity (Electrophoresis) | 4 mini-gels |
| Maximum Transfer Capacity | 2 gels (100 mm × 75 mm) |
| Temperature Control Range | 2–40 °C (Peltier-based) |
| Incubation Channels | 12 independent channels |
| Membrane Throughput | up to 24 membranes per run |
| Wash Buffer Volume Control | Adjustable per cycle |
| Imaging Sensor | High-sensitivity cooled CMOS |
| Light Sources | LED-based transillumination and epi-illumination |
| Fluorescence Channels | RGB + Far-Red/NIR (upgradable) |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compatible workflow logging |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | AM-350 |
| Measurement Width | 103 mm |
| Maximum Sample Length | 2 m |
| Scanning Speed | up to 20 mm/sec |
| Linear Accuracy | ±1% |
| Area Accuracy | ±2% |
| Perimeter Accuracy | ±5% |
| Resolution | 0.065 mm² |
| Memory | 256 KB RAM (stores up to 2,000 datasets) |
| Display | 64 × 240 pixel LCD |
| Rechargeable Battery | 12 V, 1.2 Ah (enables ~3,000 field scans) |
| Operating Temperature | 0–45 °C |
| Dimensions | 275 × 250 × 30 mm |
| Weight | 1.8 kg |
| Output Formats | BMP, TIFF |
| Interface | USB |
| Measured Parameters | leaf area, cumulative area, mean area, diseased area, length, width, perimeter, length-to-width ratio, shape factor (4πA/P², where A = area, P = perimeter) |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AM350 Portable Leaf Area Meter |
| Price | Upon Request |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | APS Multi-Channel |
| Configuration Options | 5-channel or 10-channel modular system |
| Gas Exchange Measurement Principle | Infrared Gas Analysis (IRGA) with integrated multi-port gas multiplexer |
| Leaf Chamber Interface | Detachable, independently controlled cuvettes connected via extended pneumatic tubing and signal cables |
| Compliance | Designed for GLP-compliant environmental physiology studies |
| Software Platform | APS Control Suite with audit trail, timestamped raw data export (CSV/NetCDF), and optional FDA 21 CFR Part 11–ready configuration |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | iFL Portable |
| Pricing | Available Upon Request |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCi T |
| CO₂ Range | 0–2000 ppm (0.1 ppm resolution, ±1% accuracy, 0.25 s response) |
| H₂O Range | 0–75 mbar (0.1 mbar resolution, 0.5% RH repeatability) |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ (silicon photodiode, ±5 µmol·m⁻²·s⁻¹) |
| LED Light Sources | RGB (0–2400 µmol·m⁻²·s⁻¹) or White (0–2500 µmol·m⁻²·s⁻¹) |
| Leaf Chamber Temp | −5 to 50 °C (±0.2 °C) |
| Airflow | 100–500 mL/min (±2% FS) |
| Battery Life | ~10 h (12 V, 2.8 Ah sealed lead-acid) |
| Weight | 2.4 kg (main unit), 0.6 kg (standard chamber) |
| Dimensions | 240 × 125 × 140 mm (unit) |
| Data Storage | Removable SD card (up to 32 GB) |
| Compliance | ASTM E2912-13 (gas exchange instrumentation), ISO 17025 traceable calibration protocols, GLP-compliant data logging with timestamp, GPS geotagging (latitude/longitude/elevation) |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCi-T |
| CO₂ Measurement Range | 0–2000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Measurement Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ |
| Leaf & Chamber Temperature Range | −5 to 50 °C |
| Accuracy | ±0.2 °C |
| Airflow Rate | 68–340 mL/min |
| Flow Accuracy | ±2% of full scale |
| Preheat Time | 5 min at 20 °C |
| Data Storage | SD card (up to 32 GB, 16 million data points) |
| Display | 480 × 272-pixel color WQVGA touchscreen (95 × 53.9 mm) |
| Weight | 2.4 kg |
| Dimensions | 240 × 125 × 140 mm |
| Battery Life | ~10 h (12 V / 2.8 Ah lead-acid) |
| Operating Environment | 5–45 °C |
| GPS | Integrated |
| IRGA Type | Differential open-path, auto-zeroing with pressure & temperature compensation |
| H₂O Sensor | Dual-laser tunable diode absorption spectroscopy (TDLAS) |
| Fluorescence Module (optional) | Supports F₀, Fₘ, Fₘ′, QY_Ln, NPQ, OJIP-test (26 parameters), 100 kHz sampling rate |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCpro T Intelligent Photosynthesis System |
| CO₂ Range | 0–2000 ppm |
| H₂O Control Range | 0–75 mbar |
| PAR Source | Adjustable RGB or White LED (0–2400 µmol·m⁻²·s⁻¹) |
| Temperature Control | Peltier-based (ΔT = +15 °C / −10 °C vs. ambient or ambient-follow mode) |
| GPS | Integrated with UTC time, latitude/longitude, and altitude logging |
| Humidity Sensors | Dual high-precision laser-trimmed capacitive sensors |
| IRGA Design | Gold-coated, miniaturized, time-domain differential dual-beam NDIR for drift-free CO₂ measurement |
| Leaf Chamber Climate Control | Simultaneous closed-loop regulation of CO₂, H₂O, PAR, and temperature |
| Battery Life | Up to 16 h (Li-ion) |
| Weight | Control Unit 4.1 kg, Measurement Unit 0.8 kg |
| Data Storage | SD card + USB interface |
| Fluorescence Integration | Direct hardware synchronization with FluorCam and portable chlorophyll fluorometers |
| Compliance | Designed for GLP-aligned field data acquisition |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCpro T Portable Photosynthesis System |
| CO₂ Measurement Range | 0–3000 ppm |
| CO₂ Resolution | 1 ppm |
| H₂O Measurement Range | 0–75 mbar |
| H₂O Resolution | 0.1 mbar |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ (cosine-corrected) |
| Leaf/Chamber Temperature Range | −5 to 50 °C (±0.2 °C accuracy) |
| Airflow Rate | 100–500 mL·min⁻¹ |
| CO₂ Control | Up to 2000 ppm via internal supply |
| H₂O Control | Humidity adjustable above/below ambient |
| Temperature Control | Peltier-based, ±15 °C offset from ambient |
| PAR Control | White LED up to 2500 µmol·m⁻²·s⁻¹ |
| Weight | 4.1 kg (main unit), 0.8 kg (handheld sensor handle) |
| Battery Life | Up to 16 h (12 V, 7.5 Ah Li-ion) |
| Display | 95 × 53.9 mm WQVGA color touchscreen (80 × 272 px) |
| Data Storage | Removable SD card (up to 32 GB) |
| Communication | Mini-B USB + RS232 (max. 230,400 baud) |
| Operating Environment | 5–45 °C, high-humidity/dusty conditions supported |
| Brand | ADC Bio |
|---|---|
| Origin | United Kingdom |
| Model | LCpro T |
| CO₂ Measurement Range | 0–3000 ppm (±1% accuracy, 0.1 ppm resolution, dual-beam IRGA) |
| H₂O Measurement Range | 0–75 mbar (0.1 mbar resolution, dual-laser tunable hygrometer) |
| PAR Range | 0–3000 µmol·m⁻²·s⁻¹ (cosine-corrected Si photodiode, ±5 µmol·m⁻²·s⁻¹) |
| Leaf & Chamber Temperature | −5 to 50 °C (±0.2 °C) |
| Air Flow Rate | 100–500 mL·min⁻¹ (±2% FS) |
| Response Time (CO₂) | 0.25 s |
| Auto-Zero Cycle | 4 s |
| Battery Life | Up to 16 h (12 V, 7.5 Ah Li-ion) |
| Weight | 4.1 kg (main unit), 0.8 kg (handle) |
| Dimensions | 230 × 110 × 170 mm (unit), 300 × 80 × 75 mm (handle) |
| Data Storage | Removable SD card (up to 32 GB) |
| Environmental Operating Range | 5–45 °C |
| Optional Leaf Chambers | Broadleaf (6.25 cm²), Narrowleaf (5.2 cm²), Conifer (175 cm³), Arabidopsis/Small-Leaf (16 mm Ø), Mini-Canopy (≤55 mm height), Whole-Plant Arabidopsis, Fruit Chamber (1 L), Soil Respiration Chamber (1 L), Fluorescence Adapter (compatible with OS-5p) |
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Antares |
| Instrument Type | Automated Microcalorimetric Microbial Activity Monitoring System |
| Throughput | 19 samples |
| Sample Vessel | Ø40 × H86 mm ampoule |
| Temperature Range | 5–50 °C (water-circulating thermostat control) |
| Data Acquisition Interval | 60 s (continuous operation up to 166 days) |
| Dimensions | W465 × D650 × H500 mm |
| Weight | ~100 kg |
| Power Supply | AC 100 V, 10 A |
| Installation Requirement | Temperature-stabilized laboratory environment |
| Brand | Advanced Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | VIPS® PRO |
| Pricing | Available Upon Request |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PTA |
| Pricing | Available Upon Request |