| Brand | Affinité |
|---|---|
| Origin | Canada |
| Model | P4SPR, P4PRO |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Channel Configuration | 4-channel (3 sample + 1 reference) |
| Detection Range | >88 Da |
| Sample Volume | 100 µL |
| Injection Volume | 10–200 µL |
| Analysis Time | 10 min |
| Temperature Control | Ambient |
| Light Source | Multicolor LED (550–750 nm) |
| Detector | High-uniformity gold thin-film sensor |
| Refractive Index Range | 1.333–1.390 RIU |
| Association Rate (kₐ) | 10³–10⁹ M⁻¹s⁻¹ |
| Dissociation Rate (k_d) | 10⁻⁶–10⁻¹ s⁻¹ |
| Affinity Range | pM–mM |
| Dimensions | ≤175 × 155 × 55 mm |
| Weight | <1.3 kg |
| Brand | AGDIA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RF1604 |
| Sample Throughput | 8 samples per run |
| Heating Rate | 1°C per 10 seconds |
| Temperature Accuracy | ±0.1°C |
| Well-to-Well Temperature Uniformity | ±0.1°C |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2100 |
| Instrument Type | Protein Electrophoresis System |
| Primary Device | Microfluidic Capillary Electrophoresis Platform |
| Sample Throughput | Up to 12 Samples per Run |
| Sample Volume | 1–5 µL (varies by assay type) |
| RNA Quality Metric | RNA Integrity Number (RIN) |
| Power Consumption | 60 VA |
| Safety Compliance | IEC 61010-1, Installation Category II, Pollution Degree 2 |
| Laser Classification | Class 1 |
| Operating Temperature | 15–27 °C |
| Dimensions (W × D × H) | 162 mm × 412 mm × 290 mm |
| Weight | 10 kg |
| Input Voltage | 100–240 VAC |
| Input Frequency | 50–60 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 4150 TapeStation |
| Instrument Type | Nucleic Acid Quality Control Electrophoresis System |
| Sample Capacity | Up to 16 samples per run |
| Input Voltage | 100–240 VAC, 50–60 Hz |
| Dimensions (W × D × H) | 254 mm × 510 mm × 417 mm |
| Power Consumption | 50 VA |
| Weight | 17.8 kg |
| Sample Volume Requirement | 1–2 µL per assay |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 4200 TapeStation |
| Instrument Type | Nucleic Acid Quality Control Electrophoresis System |
| Sample Capacity | 1–96 samples per run |
| Voltage/Current | 100–240 VAC, 50–60 Hz |
| Dimensions (W × D × H) | 435 mm × 510 mm × 445 mm |
| Power Consumption | 50 VA |
| Weight | 25.5 kg |
| Sample Volume Requirement | 1–2 µL per assay |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | AriaMx PCR |
| Instrument Type | Real-Time Quantitative PCR System |
| Thermal Uniformity | ±0.4 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Range | 25.0–99.9 °C |
| Max Ramp Rate | 6 °C/sec |
| Reaction Volume | 10–30 µL |
| Well Format | 96-well |
| Optical Modules | Up to 6 interchangeable filter-based modules |
| Excitation Source | Dye-specific LEDs per module |
| Detection Source | 8-channel photodiode array per module |
| Fluorophores Supported | SYBR Green, EvaGreen, FAM, HEX, ROX, CY3, CY5, ATTO 425 |
| Multiplex Capacity | Up to 5 targets per well |
| Data Acquisition Time | <3 sec per cycle |
| Onboard Storage | 5 GB |
| Touchscreen Interface | Yes |
| Remote Monitoring | Yes |
| Software Included | ARIA Software with LIMS connectivity, melt curve analysis, and FDA 21 CFR Part 11–compliant audit trail options |
| Self-Installable Optics | Yes |
| Dimensions (W×D×H) | 50.0 × 46.0 × 42.0 cm (19.7 × 18.1 × 16.5 in) |
| Warranty | 1 year standard |
| Regulatory Status | For Research Use Only (RUO) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 405 LS |
| Soaking Time | 1–600 seconds |
| Wash Cycles | 1–10 |
| Residual Volume | <2 µL per well |
| Plate Shaking | User-definable speed and duration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 405 TS |
| Instrument Type | Multifunctional Microplate Washer |
| Wash Head Design | Dual-Action Wash Head |
| Fluid Channels | 96-well and 192-channel parallel dispensing/suction |
| Soak Time Range | 0–60 minutes |
| Wash Cycles | 1–250 cycles per protocol |
| Residual Volume per Well | ≤2 µL |
| Plate Shaking | Four Adjustable Intensity Levels (Low, Medium, High, Variable) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | BioTek 406 FX |
| Instrument Type | Multi-Function Plate Washer and Dispenser |
| Sample Format Compatibility | 96-well to 1536-well microplates |
| Dispensing Technology | Non-contact positive displacement (4 syringe pumps) and peristaltic pumping (2 channels) |
| Wash Head | Dual-Action™ with adjustable aspiration/dispense height, X/Y positioning, and angled dispensing nozzles |
| Waste Disposal | Direct drain waste system |
| Automation Interface | Left- and right-side robotic arm access |
| Software Options | LHC Control Software and LHC Secure Software (21 CFR Part 11 compliant) |
| Magnetic Separation Support | Optional magnetic plate adapter |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Product Category | Imported Instrument |
| Model | 50TS |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head Configurations | 4-, 8-, 12-, or 16-channel selectable |
| Wash Fluid Ports | 4-, 8-, 12-, or 16-needle manifold |
| Soak Time | User-definable |
| Wash Cycles | 1–10 cycles |
| Orbital Shaking | Programmable intensity (5 levels) and duration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 800 TS |
| Function Type | Absorbance-Only Microplate Reader |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, and Scanning |
| Curve Fitting Options | Multiple nonlinear regression models (e.g., 4PL, 5PL, linear, quadratic, log-log) |
| Detector Type | Photodiode-based UV-Vis spectrophotometric detector |
| Wavelength Range | 400–750 nm standard |
| Absorbance Range | 0–4.0 OD |
| Absorbance Linearity | ±1.0% ± 0.010 OD (0–2.0 OD at 405 nm) |
| Plate Read Time | 11 seconds per 96-well plate |
| Precision | ±1.0% ± 0.010 OD (0–2.0 OD at 405 nm) |
| Incubation Temperature | Up to 50 °C |
| Orbital Shaking | Linear and orbital modes |
| Supported Plate Formats | 6-, 12-, 24-, 48-, 96-, 384-well microplates |
| Filter Capacity | 5-position filter wheel |
| Onboard Storage | Internal memory + USB export capability |
| Software Platform | Integrated touchscreen interface + compatibility with Agilent BioTek Gen5 v3.11 or later |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies (BioTek Division) |
| Product Type | Imported Instrument |
| Model | AutoScratch |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | BioSpa 8 |
| Temperature Control | Up to 45 °C |
| Humidity Control | 80–95% RH |
| CO₂/O₂ Control | Yes |
| Microplate Capacity | 8 plates |
| Compatible Vessel Formats | 6–1536-well microplates, cell culture dishes |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | BioStack |
| Instrument Category | Biopharmaceutical Applications |
| Plate Capacity Options | 10 / 30 / 50 microplates |
| Compatible Well Formats | 6–1536-well plates |
| Automation Level | Fully automated de-lidding and re-lidding |
| Integration Ready | Yes — with Agilent BioTek washers, dispensers, multimode readers, imagers, and Synergy Neo2 systems |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Cytation 1 |
| Temperature Control | Four-zone incubation up to 45 °C |
| Humidity Control | Integrated with four-zone incubation system |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Cytation 5 |
| Temperature Control Range | Up to 45 °C (Incubation) |
| Imaging Magnification | 1.25× to 60× (Air Objectives), 4× to 40× (Phase Contrast) |
| Microscope Type | Inverted |
| Camera | Sony CMOS, 16-bit color |
| Supported Vessels | 6–1536-well plates, slides, Petri dishes, T25 flasks, hemocytometers, chambered coverslips, Take3/Take3 Trio microplates |
| Environmental Control | Quad-zone temperature control (up to 65 °C), condensation management, CO₂/O₂ regulation, Peltier cooling |
| Detection Modes | UV-Vis absorbance, fluorescence intensity (filter & monochromator), luminescence, time-resolved fluorescence (TRF), TR-FRET, AlphaScreen/AlphaLISA, BRET, fluorescence polarization (FP) |
| Monochromator | Quad-grating system with tunable bandwidth |
| Automation Compatibility | BioSpa 8, BioStack, BenchCel, third-party robotic handlers |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Cytation 7 |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Cytation 7 |
| Temperature Control Range | Up to 45 °C |
| Throughput | High-speed automated imaging and detection |
| Cooling Option | Optional Peltier-based cooling module |
| Environmental Control | Integrated gas control (CO₂/O₂) capability |
| Automation Interface | Compatible with robotic liquid handlers and stackers |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Cytation C10 |
| Temperature Control Range | Up to 45 °C |
| Environmental Control | Dual-gas (CO₂/O₂) regulation with condensation prevention |
| Imaging Modalities | Confocal fluorescence, widefield fluorescence, brightfield, phase contrast, high-contrast brightfield, color brightfield |
| Camera | Hamamatsu ORCA-Fusion BT sCMOS (16-bit), Sony IMX series CMOS (16-bit) |
| Objective Compatibility | Olympus air objectives (1.25×–60×), phase contrast (4×–40×), water immersion (20×–60×) |
| Plate Support | 6–1536-well microplates, slides, Petri dishes, T25 flasks, chambered coverslips, hemocytometers, Take3/Take3 Trio microvolume plates |
| Z-stack capability | Motorized focus with DSD (Deep Slice Disk) 60 µm pinhole option |
| Excitation Source | Tunable quad-grating monochromator (UV–Vis), laser-based confocal illumination |
| Automation Integration | BioSpa 8 incubator, BioStack stacker |
| Software Platform | Gen5 Image+ data acquisition and analysis suite |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Product Category | Imported Instrument |
| Model | EL406 |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Epoch |
| Function Type | Absorbance-Only Microplate Reader |
| Automation Level | Fully Automated |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 200–999 nm |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Epoch2 |
| Function Type | UV-Vis Absorbance-Only Microplate Reader |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting Options | Linear, Quadratic, Cubic, Four-Parameter Logistic (4PL), Five-Parameter Logistic (5PL), Log-Log, Spline |
| Detector Type | UV-Visible Photodiode Array |
| Wavelength Range | 200–999 nm (1 nm increments) |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | ±1% ± 0.01 OD (0–2 OD) |
| Plate Read Time | 8 sec (96-well), 14 sec (384-well) |
| Precision | ±1% ± 0.01 OD (0–2 OD) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | LogPhase 600 |
| Instrument Type | Automated Microbial Growth Monitoring System |
| Throughput | Up to four 96-well microplates simultaneously |
| Optical Density Measurement | OD600 (600 nm) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Synergy H1 |
| Pricing | Upon Request |
| Functionality | Multi-Mode |
| Automation Level | Fully Automated |
| Assay Methods | Endpoint, Kinetic, Wavelength Scan, Well Area Scan |
| Curve Fitting Options | Linear, Logarithmic, Four-Parameter Logistic (4PL), Five-Parameter Logistic (5PL) |
| Detector Type | Photomultiplier Tube (PMT) / Photodiode (PD) |
| Wavelength Range | Filter-based: 200–700 nm |
| Monochromator-based | 250–900 nm |
| Absorbance Range | 0.0000–4.0000 OD |
| Absorbance Linearity | Not Specified |
| Read Speed | 96-well plate in 11 s |
| Accuracy | Not Specified |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Synergy HTX |
| Function Type | Multi-Mode |
| Automation Level | Fully Automated |
| Assay Methods | Endpoint, Kinetic, Well-Scanning |
| Curve Fitting Options | Linear, Point-to-Point, Four-Parameter Logistic (4PL) |
| Detector Types | Fluorescence, UV-Vis Absorbance, Luminescence, Time-Resolved Fluorescence (TRF), AlphaScreen/AlphaLISA |
| Wavelength Range | Filter-Based: 200–850 nm |
| Monochromator-Based | 200–999 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | <1% deviation from ideal linearity across 0–3.0 OD |
| 96-Well Read Time | 14 seconds |
| Absorbance Precision | ±0.0001 OD |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Synergy LX |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Well-Scanning |
| Curve Fitting Options | Linear, Point-to-Point, Four-Parameter Logistic (4PL) |
| Detector Types | UV-Vis Absorbance, Fluorescence Intensity, Luminescence |
| Wavelength Range | Filter-Based: 320–850 nm |
| Monochromator-Based | 200–999 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | <1% deviation from ideal over 0–2.5 OD |
| Read Time (96-well plate) | 12 s |
| Absorbance Precision | ±0.0001 OD |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | BioTek Synergy Neo2 Hybrid |
| Detection Methods | Absorbance, Fluorescence Intensity (tunable bandwidth), Luminescence, Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP), TR-FRET, BRET, AlphaScreen/AlphaLISA |
| Detector Types | Dual Photomultiplier Tubes (PMTs), Monochromator-based and Filter-based Optical Paths, 337 nm Pulsed Laser for TRF, 100 mW Solid-State Laser for Alpha Detection |
| Automation | Fully Automated with BioStack Neo |
| Environmental Control | 4-Zone Temperature Control up to 70 °C, CO₂/O₂ Regulation, Anti-Condensation System, Linear & Orbital Shaking |
| Sample Formats | 6–1536-well Microplates, Take3/Take3 Trio Microvolume Plates, Petri Dishes, Cell Culture Dishes |
| Software | Gen5 v3.1+ with LIMS Integration, FDA 21 CFR Part 11 Compliance Support, Audit Trail, Electronic Signatures |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | Take3 |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Fragment Analyzer 5400 |
| Instrument Type | Nucleic Acid Electrophoresis System |
| Sample Throughput | >2,400 samples per 24 hours |
| Voltage/Current | 100–240 VAC, 47–63 Hz |
| Dimensions (W × D × H) | 36 cm × 51 cm × 61 cm |
| Power Consumption | 150 VA |
| Operating Temperature | 19–25 °C |
| Relative Humidity | 20–80 % RH |
| Weight | 38.5 kg |
| Sample Format | 96-well plate per run |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | Lionheart FX |
| Temperature Control | Up to 40 °C |
| Humidity Control | Integrated Humidity Chamber |
| Imaging Throughput | High-speed Kinetic Acquisition |