| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon NIR / NIR+ |
| Instrument Type | Multicolor Fluorescent Gel Imaging System |
| Detection Principle | Confocal Laser Scanning with Dual-NIR Fluorescence Excitation and Emission Filtering |
| Laser Wavelengths | 685 nm, 785 nm |
| Emission Filters | IRshort 720BP20, IRlong 825BP30 |
| Scan Modes | Automatic, Semi-Automatic, Manual |
| Sample Formats | SDS-PAGE gels, agarose gels, nitrocellulose/PVDF membranes, microplates, Petri dishes, glass slides, tissue sections |
| Detector | Enhanced Photomultiplier Tube (PMT) optimized for NIR spectral range |
| Dynamic Range | >4 orders of magnitude (log-linear response) |
| Spatial Resolution | ≤50 µm (pixel size adjustable) |
| Software Platform | ImageQuant TL with GLP-compliant audit trail and 21 CFR Part 11 optional modules |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon RGB |
| Imaging Modes | Multicolor Fluorescence (RGB), Dual-Channel Near-Infrared (NIR), Phosphor Imaging, Optical Density (OD) |
| Pixel Resolution | Down to 10 µm |
| Scan Area | Up to 40 × 46 cm (Typhoon 5/RGB) |
| Dynamic Range | >5 orders of magnitude |
| Detection Sensitivity | As low as 3 pg protein (fluorescently labeled) |
| Laser Configuration | 5-laser platform (Typhoon 5) |
| Detector Type | High-gain Photomultiplier Tubes (PMTs) |
| Upgrade Path | Field-upgradable across models |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Biacore 1K SPR System |
| Configuration | Single-injection needle, six-flow-cell platform |
| Regulatory Readiness | Optional GxP-compliant software package (21 CFR Part 11 audit trail enabled) |
| Software | Biacore Insight™ v3.x |
| Service Support | OptiRun™ lifecycle service program |
| Upgrade Path | Compatible with Biacore 1K+ expansion module for enhanced ligand multiplexing and sample throughput |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Biacore 1K+ SPR System |
| Channel Configuration | Single-needle, 6-flow cell architecture |
| Sample Capacity | Dual 96-well microplate support + dual reagent racks |
| Buffer Selection | Integrated automated buffer selector |
| Temperature Control | Precise thermostatic sample compartment |
| Software Platform | Biacore Insight™ with FDA 21 CFR Part 11-compliant audit trail and GLP/GMP-ready data management |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biacore 1S+ SPR System |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Flow Cell Configuration | Six parallel flow cells |
| Detection Range | fM to mM |
| Sample Capacity | Up to two 96-well or 384-well microplates plus 21–43 additional sample positions |
| Analysis Time per Cycle | 2–15 minutes |
| Temperature Control Range | 4–37°C |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biacore 8K+ SPR System |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Channel Configuration | Multi-channel (8 sample needles, 16 simultaneous interaction channels) |
| Detection Range | fM to mM |
| Sample Capacity | Up to 4,608 samples (12 × 384-well plates or 24 × 96-well plates) |
| Analysis Time per Cycle | 2–15 minutes |
| Temperature Control Range | 4°C to 40°C |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Biacore S200 |
| Instrument Type | Label-Free Molecular Interaction Analyzer |
| Application Focus | Fragment-Based Drug Discovery (FBDD), Kinetic & Affinity Analysis, Epitope Mapping, Competitive Binding Assays |
| Regulatory Context | Designed for GLP-compliant workflows |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Biacore X100 |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Channel Configuration | Multi-channel |
| Detection Range | pM–mM |
| Sample Capacity | 15 samples per run |
| Analysis Time | 2–15 minutes per interaction cycle |
| Temperature Control Range | 4–40 °C |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | BioProcess pcc 1/2" |
| Control Software | UNICORN™ or DeltaV™ |
| Column Configuration | 3-column (3C) or 4-column (4C) |
| Application | Continuous downstream purification of therapeutic proteins |
| Compliance Framework | Supports FDA 21 CFR Part 11, GMP, and GLP audit trails via software configuration |
| Service Support | OptiRun™ lifecycle service packages available |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioProcess Resin Mixer |
| Pricing | Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Ettan 2D DIGE |
| Instrument Type | Two-Dimensional Fluorescent Differential Gel Electrophoresis System |
| Core Components | Ettan IPGphor 3 Isoelectric Focusing Unit, Amersham DIGE Unit LF24 Vertical SDS-PAGE Electrophoresis System, Typhoon Laser Scanner with Multi-Channel Fluorescence Detection, CyDye DIGE Fluorophores (Cy2/Cy3/Cy5), Melanie 9 Image Analysis Software |
| Sample Capacity | Up to 3 samples co-separated per 2D gel |
| Sensitivity | Quantitative detection of ≤10% protein abundance change with ≥95% statistical confidence |
| Minimum Sample Requirement | As low as 5 µg total protein per sample |
| Compliance | Designed for GLP-compliant proteomics workflows |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Ettan IPGphor 3 |
| Instrument Type | Isoelectric Focusing (IEF) Electrophoresis System |
| Gel Format Compatibility | IPG strips (7 cm, 11 cm, 13 cm, 18 cm, 24 cm) |
| Sample Capacity | Up to 12 IPG strips per run (with standard manifold) or single IPG strip with Ettan IPGphor Manifold |
| Voltage Range | 0–10,000 V (programmable ramping and stepwise control) |
| Current Limit | 0–100 µA–100 mA (auto-adjusting) |
| Temperature Control Range | 15–30 °C (±0.1 °C stability) |
| Dimensions (W×D×H) | 278 × 160 × 471 mm |
| On-device Method Storage | 10 methods (9 steps each) |
| PC Software Control | Ettan IPGphor 3 Control Software (supports up to 4 instruments simultaneously) |
| Data Logging | Real-time voltage, current, and kV·h monitoring with graphical export |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | iCELLis™ Nano Bioreactor System |
| Temperature Range | Double-jacketed with TCU – 20–40 °C |
| Surface Area Range (iCELLis™ 500+) | 60–500 m² |
| Surface Area Range (iCELLis™ Nano) | 0.53–4 m² |
| Configuration | Single-use, integrated fixed-bed bioreactor |
| Operating Modes | Batch and perfusion |
| Compliance | Designed to support GMP-compliant manufacturing |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | NanoAssemblr™ Ignite™ Instrument |
| Flow Rate Range | 20–200 mL/min |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Instrument Type | High-Throughput |
| Synthesis Scale Range | 10–1800 µmol |
| Explosion-Proof Design | Yes |
| Industrial-Grade Components | Yes |
| Regulatory Compliance | GMP-Ready, Supports FDA 21 CFR Part 11 & EU Annex 11 |
| Software Platform | UNICORN® v7.x or later |
| Scalability | Linear lab-to-commercial scale-up |
| Annual Production Capacity | Up to hundreds of kilograms (kg/yr), extendable to metric tons under continuous operation |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | OligoProcess™ |
| Synthesis Scale | 10–1800 mmol per run |
| Regulatory Compliance | FDA 21 CFR Part 11, GMP-ready architecture |
| Software Platform | UNICORN 7.x or later |
| Column Technology | Flow-through synthesis columns (compatible with ÄKTA oligopilot plus and OligoPilot 400) |
| Construction | Industrial-grade, explosion-proof certified components |
| Application Scope | Clinical-phase development through commercial-scale cGMP manufacturing |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | ReadyToProcess WAVE 25 |
| Maximum Working Volume | 25 L |
| Drive Mechanism | Motorized Rocking Platform with Adjustable Speed, Angle, and Motion Profile |
| Temperature Control | Integrated Heated Tray with Dual Independent PID Loops (Dual-Mode Operation) |
| Weight Measurement | Built-in Load Cells with Auto-Calibration Capability |
| Gas Transfer | Passive O₂/CO₂ Exchange via Sterile Vent Filters (Heated Exhaust Filter Included) |
| Data Storage | Dual Mirrored SSDs + UNICORN Database Integration |
| Communication Protocol | OPC UA Compliant |
| Compliance | Designed for GMP Environment |
| Brand | Cytiva |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | GE ReadyToProcess WAVE 25 Bioreactor |
| Temperature Range | 6–60 °C |
| Working Volume Range | 10–2000 L |
| Number of Vessels | 1 |
| Construction Material | Stainless Steel |
| Sterilization Method | Single-Use Bioreactor System |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | WAVE 20/50 |
| Maximum Working Volume | 25 L |
| Tray Sizes | 5 L / 10 L / 25 L |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Instrument Model | Sefia S-2000 |
| Type | Fully Automated |
| Regulatory Designation | Import (CE-marked for IVDR/MDR-compliant use in cell therapy manufacturing) |
| Single-Use Kit Compatibility | CT-300.1, CT-400.1 + PB-100.1, CT-200.1, CT-800.1, CT-350.1S |
| Software Integration | Chronicle™ v3.2+ with eSOP/eBMR and 21 CFR Part 11 / EU Annex 11 compliance |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Type | Fully Automated |
| Model | Sefia™ Automated Cell Expansion System |
| Compliance | CE-marked (2006/42/EC), IEC 61010, IEC 61326, ICES-001 Class A, China RoHS SJ/T11364-2014 |
| Software Compliance | Chronicle™ Viewer validated per GAMP™5 and FDA 21 CFR Part 11 |
| Operating Environment | 15–25°C, 20–80% RH (non-condensing), 840–1060 mbar, indoor use only, max. altitude 2000 m |
| Consumables | Single-use FEP or silicone-based disposable kits (e.g., Cat. No. 29716713, 29739346) |
| Integration | Compatible with Chronicle™ Viewer for audit-trail-enabled data management and real-time process monitoring |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sepax C-Pro Cell Processor |
| Type | Fully Automated |
| Compliance | CE (2006/42/EC), IEC 61010, IEC 61326, IEC 62304 |
| Software Integration | Chronicle eSOP, GAMP 5-aligned, FDA 21 CFR Part 11-ready audit trail capability |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | STF-IRc |
| Tube OD Capacity | Up to 22.2 mm |
| Automation Level | Fully Automated |
| Sterility Assurance | Validated Aseptic Connection without Biosafety Cabinet |
| Application Domain | Bioprocessing Fluid Transfer |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | TE22 |
| Instrument Type | Wet Protein Electrophoretic Transfer System |
| Gel Capacity | Up to 4 × 9 cm × 10 cm gels per run |
| Cooling System | Integrated aluminum heat exchanger with recirculating buffer cooling |
| Temperature Rise | ≤5°C during standard transfer |
| Buffer Volume Requirement | 1 L per full-load run (4 gels) |
| Cassette Design | Open-mesh gel clamp for uniform pressure, gel/membrane alignment, and prevention of gel wrinkling or drying |
| Compliance | Designed for compatibility with standard SDS-PAGE and Western blotting workflows per ISO/IEC 17025-aligned laboratory practices |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | UniFlux Tangential Flow Filtration System |
| Flow Rate Options | 10, 60, 120 L/min (400 L/min available on custom basis) |
| Vessel Capacity Range | 5–600 L (stainless steel or single-use mixing systems supported) |
| Automation Platform | UNICORN Software (21 CFR Part 11 compliant) |
| Application Scope | Microfiltration (e.g., cell harvest) and Ultrafiltration (e.g., protein concentration & diafiltration) |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | UniFlux™ |
| System Variants | UniFlux™ 10, 30, 120, 400 |
| Membrane Area Range | 0.11–52 m² |
| Feed Volume Capacity | 1–10,000+ L |
| Construction Materials | 316L Stainless Steel, USP Class VI Polymers |
| Control Software | UNICORN™ v7.x or later |
| Regulatory Compliance | FDA 21 CFR Part 11, GMP/GLP-Ready, cGMP-Compatible Design |
| Pressure Monitoring | 4 Real-Time Channels |
| Sensor Integration | Temperature, UV Absorbance, pH, Conductivity, Air Flow, Transmembrane Pressure (TMP), Differential Pressure (ΔP), Crossflow & Permeate Flow Rates |
| Pump Types | Sanitary Diaphragm & Rotary Lobe Pumps |
| Integrity Test | Integrated Air Flow-Based Filter Integrity Testing |
| Cleaning | Fully Automated CIP Method Development & Water Flux Validation |
| Data Management | Audit Trail, Electronic Signatures, 10-Tier User Access Control, Logbook Generation |
| Brand | Cytiva |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Omics Bundle |
| Separation Method | Automated |
| Cell Viability (%) | ≥90% |
| Compatibility | Requires Integration with VIA Freeze™ Uno Controlled-Rate Freezer |
| Intended Use | Research Use Only (RUO), Not for Diagnostic Purposes |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | VIA Freeze Uno |
| Type | Fully Automatic |
| Cooling Method | Conductive |
| Compliance | cGMP, 21 CFR Part 11, ISO 13485 (via system integration) |
| Sample Capacity | 24–192 cryovials, up to 250 mL cryobags, cryostraws (with interchangeable trays) |
| Calibration | Supplied with NIST-traceable calibration certificate |
| Qualification | IQ/OQ documentation included |
| Software Integration | Chronicle™ Automation Platform (optional standalone purchase) |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | VIA Thaw™ L1000 |
| Type | Fully Automated |
| Regulatory Classification | Import (CE-marked for IVD/medical device use in EU |
| Compliance | Designed to support GMP-compliant cell therapy manufacturing per ISO 13485, ASTM F3276-21 (Standard Guide for Cryopreserved Cellular Product Thawing), and 21 CFR Part 11–ready when used with Chronicle™ software |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Wave Mixer |
| Type | Sterile, Non-invasive Oscillatory Mixing System |
| Capacity | Up to 10 L |
| Mixing Time | ≤6.5 s for full homogenization |
| Drive Mechanism | Programmable Rocking Platform with Sinusoidal Motion Profile |
| Sterility Assurance | Designed for use with single-use bioprocess bags (e.g., Cytiva HYPERSTACK®, Xcellerex™ XDR bags) |
| Compliance | Compatible with ISO 13485–certified manufacturing environments and supports GMP-aligned process validation |