| Brand | FiberCell Systems |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | P3202 |
| Housing Material | Polysulfone |
| Configuration | Duet Pump + Cartridge-Based Closed Perfusion System |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SuPerMax-3100 |
| Function Type | Multimode |
| Automation Level | Fully Automated Microplate Reader Workstation |
| Assay Modes | Endpoint Fluorescence, Absorbance, Chemiluminescence (ELISA/EIA) |
| Curve Fitting Options | Multiple nonlinear regression models (e.g., 4PL, 5PL, linear, quadratic, log-log) |
| Detectors | Photodiode (Absorbance), PMT (Fluorescence), Photon Counting PMT (Chemiluminescence) |
| Wavelength Range | 190–1000 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Excitation & Emission Monochromators | Dual high-resolution grating monochromators |
| Bandwidth | Adjustable from 2 to 20 nm |
| Temperature Control Range | Ambient to 65 °C |
| Plate Formats | Standard 96-well (customizable to 24-, 384-, 1536-well) |
| Dispensing Capability | Dual-channel liquid handler (expandable to quad-channel) |
| Reading Modes | Top-read and bottom-read fluorescence |
| Kinetic & Spectral Scanning | Supported |
| Software Compliance | IQ/OQ/PQ validated |
| Brand | FlowCam |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FlowCam 8000 |
| Pricing | Available Upon Request |
| Brand | Flownamics |
|---|---|
| Origin | USA |
| Model | FISP Sterile Sampling Probe |
| Construction | 316 Stainless Steel |
| Membrane Material | Ceramic |
| Standard Pore Size | 0.2 µm |
| Optional Pore Sizes | 0.45, 0.75, 1.0, 5.0, 25.0, 75.0 µm |
| Port Compatibility | D-Series (19 mm & 25 mm side ports), F-Series (8 mm, 12 mm & 19 mm top ports) |
| Immersion Depth Options | 90–410 mm |
| Dead Volume | 0.24–0.44 mL |
| Brand | FluidicLab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CCS-01 |
| Instrument Type | Automated |
| Reservoir Volume | 15 mL |
| Dimensions (H×W×D) | 18 × 17.7 × 16 cm (including reservoir) |
| Temperature Control Range | 15–40 °C |
| Minimum Perfusion Volume | 1 mL |
| Flow Rate Range | 0.8–400 µL/min |
| Independent Fluid Channels | 2 or 4 |
| Tubing Compatibility | Tygon® L/S 0.38 mm ID / 0.8 mm OD |
| Pressure Limit | ≤0.1 MPa |
| Power Supply | AC 220 V, 50 Hz, <10 VA |
| Operating Temperature | 15–40 °C |
| Weight | 1.5 kg |
| Brand | FluidicLab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Flow Cell |
| Price | USD 1,350 (approx.) |
| Instrument Type | Manual |
| Dimensions (L×W×H) | 60 × 65 × 15 mm |
| Brand | FluidicLab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Producer |
| Region of Origin | Domestic (China) |
| Model | LNP-B1 (with Luer Fitting) |
| Chip Material | Cyclic Olefin Copolymer (COC) |
| Chip Type | Droplet-Generation Microfluidic Chip |
| Dimensions (mm) | 62.2 × 41.3 |
| Channel Width | 350–700 µm |
| Max Operating Pressure | 50 bar |
| Total Fill Volume | 8.22 µL |
| Mixing Structure Volume | 2.09 µL |
| Recommended Total Flow Rate | 16 mL/min |
| Maximum Total Flow Rate | 40 mL/min |
| Compatible Instruments | FluidicLab LNP-S1 & LNP-S2 Intelligent Lipid Nanoparticle Synthesizers |
| Application Range | Total Synthesis Volume 0.4–40 mL |
| Flow Regime | Medium-volume, medium-flow-rate LNP formulation |
| Brand | FluidicLab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Producer |
| Product Category | Domestic |
| Model | PDMS-HTS-80 |
| Price | USD 185 (excl. VAT & shipping) |
| Chip Material | Covalently bonded PDMS microchannels on borosilicate glass substrate |
| Chip Type | Step-emulsion droplet generation chip |
| Channel Width | 160 µm |
| Nozzle Geometry | Parallel stepped orifice array (188 independent units) |
| Droplet Diameter Range | 80–100 µm |
| Aqueous Phase Flow Rate Range | 10–1000 µL/min (CV < 5% under stable pressure control) |
| Substrate Dimensions | 75 × 25 × 2 mm (glass), Chip Active Area: 62 × 19 × 2 mm |
| Surface Treatment | Hydrophobic silanization of PDMS channels |
| Operational Configuration | Dual-inlet/dual-output symmetric layout (Chip I: Inlets ①/② → Outlet ③ |
| Chip II | Inlets ④/⑤ → Outlet ⑥) |
| Brand | FLUIDOT |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | FLUIDOT (Original Equipment Manufacturer) |
| Model | FDT-MF120 |
| Configuration | Three independent peristaltic pump channels |
| Display | 10-inch capacitive touchscreen |
| Maximum dish capacity per stacker | 40 × 90 mm Petri dishes (3 stackers total) |
| Dispensing modes | 5 programmable modes (Auto-Dispense, Auto-Dispense + Manual Sample Addition, Auto-Dispense + Auto-Sample Addition, Manual Dispense, Label Printing) |
| Pump control | Individual on/off and speed control for each of 3 peristaltic pump heads |
| Parameter storage | Up to 5 complete dispensing & oscillation protocols |
| Oscillation control | Independent X/Y-axis oscillation speed, amplitude, cycle count, and repeat iterations |
| Sterilization | Built-in UV-C lamp in dispensing chamber |
| Optional accessories | Integrated sample auto-sampler module, media temperature-controlled stirring unit, footswitch interface |
| Compliance | Designed for ISO 13485-aligned laboratory environments |
| Brand | Fluidot |
|---|---|
| Model | FDT-MF80 |
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Category | Domestic (China-made) |
| Pricing | Upon Request |
| Plate Capacity per Stack | 40 × 3 Stacks |
| Dispensing Modes | 4 (Auto-Dispense Only |
| Dispensing Pump Options | Single or Dual Peristaltic Pump Head |
| Tubing | Removable & Autoclavable |
| UV Sterilization | Integrated in Dispensing Chamber |
| Sample Mixing | Programmable Orbital Shaking (Amplitude & Cycle Count Adjustable) |
| Liquid Priming & Post-Dispense Aspiration | Automatic |
| Touchscreen Interface | Full-Function HMI with Parameter Programming (Volume, Speed, Shake Profile, Stack Control) |
| Safety Features | Real-time Petri Dish Presence Detection, Emergency Stop, Footswitch-Compatible Operation |
| Compliance | Designed for GLP-compliant workflows |
| Brand | -- |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FluorCam-WIC |
| Pricing | Upon Request |
| Brand | FMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Human Energy Metabolism Laboratory System |
| Price Range | USD 28,000 – 70,000 |
| Brand | Forerunner |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZJL-200 |
| Instrument Type | Fully Automated Colony Counter |
| Petri Dish Compatibility | ≤150 mm diameter |
| Counting Speed | <1 second for ≤500 colonies |
| Colony Size Detection Range | 0.08–100 mm |
| Counting Modes | Fully Automatic, Manual, Spiral Plate Mode |
| Image Resolution | 1080×720 to 2160×1440 pixels |
| Custom Dilution Series Support | Yes |
| Illumination | Dual-mode cold LED source (top and bottom transillumination) |
| Operating Environment | 10–40 °C, ≤80% RH |
| Reporting | Exportable electronic reports (PDF, CSV, Excel), printable hardcopy |
| Software Interface | LIS-compatible (HL7, ASTM E1384 compliant) |
| Hardware Interface | USB 2.0 |
| Brand | FOREVERGEN |
|---|---|
| Model | OE |
| Instrument Type | Fully Automated |
| Detection Method | Visible Light Absorption Spectroscopy |
| Measured Gases | CO₂, O₂ |
| Accuracy | ≤ ±1–2% of Full Scale |
| Dimensions (W×D×H) | 430 × 350 × 120 mm |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MUVIS® |
| Field of View (mm) | 3.7 × 3.0 |
| Pixel Size (µm) | 1.1 |
| Optical Resolution (µm) | 2 |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | RI1 |
| Field of View (mm) | 6.1 × 5.0 – 1.9 × 1.5 |
| Pixel Size (µm) | 1.8 – 0.56 |
| Optical Resolution (µm) | 5 – 1 |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RI360 / RI1000 |
| Field of View (mm) | 9.49 – 0.79 |
| Pixel Size (µm) | 3.20 – 0.27 |
| Optical Resolution (µm) | 4.39 – 0.83 |
| Brand | Formulatrix |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SONICC® |
| Price | Upon Request |
| Field of View (mm) | 2.2 × 2.2 to 0.65 × 0.65 |
| Optical Resolution (µm) | 4.0 to 1.1 |
| Brand | FOUR E'S SCIENTIFIC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PWT100101 |
| Temperature Range | Ambient to 99°C (adjustable in 1°C increments) |
| Temperature Accuracy | ±1°C |
| Warm-up Time | 5–10 min to max temperature |
| Operating Duration | Up to 8 hours continuous |
| Working Surface | Large grooved heated platform |
| Wax Collection | Magnetic detachable drip tray with disposable liner |
| Safety Features | Auto power-resume after outage, over-temperature cutoff |
| Brand | FOUR E'S SCIENTIFIC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SDR200101 |
| Pricing | Upon Request |
| Brand | FOUR E'S SCIENTIFIC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WXD101201 |
| Pricing | Upon Request |
| Capacity | 7.5 L (≈3.5 kg solid paraffin) |
| Heating Method | Bottom + sidewall integrated heating |
| Temperature Control | Digital PID controller with ±0.5 °C stability |
| Dispensing System | Triple-position heated lever faucet with drip-free operation |
| Filtration | Integrated 0.5 mm stainless-steel mesh filter |
| Safety Design | Insulated paraffin tank with cool-touch external surface |
| Dimensions | Compact benchtop footprint (<400 × 350 × 420 mm) |
| Compliance | Designed for GLP-compliant pathology laboratories |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | BC |
| Pricing | Upon Request |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | Bio-Memory |
| Temperature Range | −86 °C |
| Insulation | Full-enclosure Vacuum Insulation Panels (VIP) |
| VIP Thermal Conductivity | <0.005 W/(m·K) |
| Wall Thickness | 80 mm |
| Energy Consumption Reduction | 15% |
| Power-Outage Hold Time Increase | 22% |
| Internal Volume Gain vs. Conventional ULT | +20–30% |
| Compliance | RoHS-compliant, ODS-free manufacturing |
| Configuration Options | Upright, Horizontal, Benchtop |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | BM 175 / BM 340 / BM 515 / BM 690 / BM 1000 |
| Instrument Type | Upright |
| Net Capacity | 176 L to 1011 L |
| Inner Dimensions (W×D×H mm) | 452×630×620 to 765×920×1436 |
| External Dimensions (W×D×H mm) | 875×712×1330 to 1200×1004×2000 |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power Consumption | 400 W |
| Noise Level | <55 dBA |
| Refrigerant | CFC-free & HCFC-free blend (R404A/R290 hybrid or equivalent) |
| Temperature Range | –86 °C standard operating setpoint (stable operation from –80 °C to –86 °C) |
| Temperature Uniformity | ±1 °C (at –80 °C, measured per IEC 61000-4-2 and ISO 15502 protocols) |
| Insulation | Six-sided Vacuum Insulation Panel (VIP) core with polyurethane foam secondary layer |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | BMS 175 / 340 / 515 / 690 / 1000 |
| Configuration | Upright |
| Net Volume | 176–1011 L |
| Interior Dimensions (W×D×H mm) | 452×630×620 to 765×920×1436 |
| Exterior Dimensions (W×D×H mm) | 875×712×1330 to 1200×1004×2000 |
| Power Supply | 220 V AC, 50/60 Hz |
| Noise Level | <55 dBA |
| Refrigerant | CFC-free & HCFC-free blend (R508B/R290 hybrid system) |
| Temperature Range | –86 °C stable operation |
| Uniformity | ±1 °C (at –80 °C, measured per IEC 61000-4-2 and ISO 13732-1) |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | Darwin |
| Construction | Aerospace-grade Aluminum Alloy |
| Storage Mode | Vapor-phase or Liquid-phase |
| Capacity Options (2 mL Cryovials) | 750, 2000, 3600, 4800, 6000, 3618, 4824 |
| Neck Diameter | Optimized for Rapid Sample Access |
| Static LN₂ Evaporation Rate | <0.8 L/day (typ. for 3600-capacity unit) |
| Vacuum Insulation | Multi-layer reflective foil + high-vacuum interspace (<1×10⁻³ Pa) |
| Optional Accessories | CryoMemo™ Real-time Monitoring System, Active De-gassing Unit |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | GT |
| Pricing | Upon Request |
| LN₂ Capacity | 2–40 L |
| Sample Storage Capacity | 150–7,300 × 0.5 mL Straws |
| Static Hold Time | 25–350 days |
| Brand | Froilabo |
|---|---|
| Model | Origin |
| Construction | Stainless Steel |
| Origin | France |
| Capacity Range | 500–1636 L |
| Sample Storage Capacity | 27,300–90,400 × 1.2/2 mL Cryovials |
| Storage Mode | Dual-phase (Liquid & Vapor) |
| Evaporation Rate | Low (Optimized Vacuum Insulation) |
| Optional Accessories | Aluminum Rotating Rack, CryoMemo Monitoring System |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows |
| Intended Use | Long-term cryopreservation of biological specimens |
| Brand | Froilabo |
|---|---|
| Origin | United Kingdom |
| Model | Polaris |
| Capacity Range | 5,200–94,500 × 2 mL Cryovials |
| Construction | Medical-Grade Stainless Steel |
| Cooling Mode | Vapor-Phase Storage |
| LN₂ Evaporation Rate | Optimized Low-Loss Design |
| Control Interface | CryoLog Color Touchscreen Display |
| Security | Three-Tier User Authentication & Audit Trail Logging |
| Compliance | Designed for GLP/GMP-aligned biobanking environments |
| Certification | CE-marked per EU Medical Device Regulation (MDR) Annex I essential requirements |
| Brand | Froilabo |
|---|---|
| Origin | France |
| Model | TR Series |
| Construction Material | Aerospace-Grade Aluminum Alloy |
| Vessel Type | Static, Non-Pressurized Liquid Nitrogen Dewar |
| Intended Use | Long-Term Biological Sample Storage at –196 °C |
| Regulatory Context | Designed for GLP/GMP-Compliant Environments |
| Compliance | Meets ISO 23775-1:2022 (Cryogenic Vessels — Part 1: Design and Construction) |
| Safety Certification | CE Marked per PED 2014/68/EU (Pressure Equipment Directive) for auxiliary pressure systems (e.g., optional LN₂ transfer pumps) |
| Capacity Range | 10 L to 100 L (nominal static hold time: 12–120 days depending on model and ambient conditions) |
| Evaporation Rate | 0.12–0.85 L/day (model-dependent, measured at 20 °C ambient, 50% fill level) |
| External Dimensions | Ø220–Ø520 mm × H500–H1200 mm |
| Net Weight | 8.5–42 kg (empty, aluminum-only configuration) |
| Neck Tube Diameter | 50–125 mm |
| Accessories Supported | Programmable LN₂ Level Sensors, Auto-Fill Systems, RFID Sample Rack Integration Kits, Temperature Monitoring Probes (–200 °C to +85 °C), Locking Lid Assemblies |