Life Science Instruments
Filter
Showing 1411–1440 of 7558 results
| Brand | CID Inc. (USA) |
|---|---|
| Origin | USA |
| Model | CI-340 |
| CO₂ Range | 0–2000 ppm (standard), 0–3000 ppm (optional) |
| PAR Range | 0–2500 µmol·m⁻²·s⁻¹ |
| Flow Rate | 100–1000 mL/min |
| Operating Temp | 0–45 °C |
| Operating RH | 5–95% RH (non-condensing) |
| Battery Life | 4–6 h (standard operation), up to 10 h with low-power configuration |
| Weight | 1.5 kg (with leaf chamber & Li-ion battery) |
| Data Storage | 4 MB flash memory (~1.6 million data points) |
| Display | 40×6-character LCD (320×64 pixels) |
| Interface | USB |
| CO₂ Sensor | NDIR, 1 Hz chopper frequency, <2% accuracy, 0.1 ppm resolution |
| Humidity Sensor | Capacitive, 0–2100% RH, ±2% RH @10% RH, ±3.5% RH @90% RH |
| PAR Sensor | GaAsP photodiode with cosine correction, 400–700 nm, ±5 µmol·m⁻²·s⁻¹ accuracy |
| Air Temp Sensor | Thermocouple, –15–50 °C, ±0.1 °C |
| Leaf Temp Sensor | Non-contact infrared, –10–50 °C, ±0.3 °C |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CI-340 |
| Pricing | Available Upon Request |
| Brand | CID |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | CI-600 |
| Pricing | Upon Request |
| Operating Environment | 0–50 °C, 0–100% RH (non-condensing) |
| Imaging Resolution Options | 100 / 300 / 600 / 1200 DPI |
| Sensor Pixel Count | 2.35 Megapixels |
| Scan Area per Frame | 21.56 cm × 19.56 cm |
| Scan Time | ≥30 seconds (resolution-dependent) |
| Probe Dimensions | 34.3 cm length × 6.4 cm diameter |
| Transparent Access Tube ID | 6.36 cm, OD: 7.0 cm, Wall Thickness: 3.2 mm, Length Options: 1 m or 2 m |
| System Mass | 750 g (probe only) |
| Power Supply | UMPC-based terminal |
| Data Storage | Direct to onboard processing terminal |
| Image Formats | BMP, JPG, TIFF, PNG |
| Software Platforms | CI-690 RootSnap (touch-optimized), WinRHIZO Tron MF (desktop-based) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CSG-2000 Series |
| Price | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Circumrotation Behavior Analysis System |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CITSensBio |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Temperature Operating Range | 4–40 °C |
| Reaction Volume Compatibility | 50 mL – 10 L |
| Number of Bioreactor Vessels Supported | Single-vessel real-time monitoring (modular expansion to multi-vessel via ZOMOFI® gateway) |
| Construction Material | Medical-grade PEEK housing, platinum-iridium sensing elements, sterilizable silicone O-rings |
| Sterilization Method | Gamma irradiation (25–35 kGy), validated for ISO 11137 compliance |
| Origin | France |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | CITSensBio |
| Price Range | USD 13,500 – 27,000 (est.) |
| Sterilization Method | Gamma Irradiation |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 37550 |
| Price Range | USD 7,000 – 14,000 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | C76688 |
| Pricing | Available Upon Request |
| Brand | Bioyong |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Clin-TOF-I |
| Price Range | USD 140,000 – 280,000 |
| Brand | Clinkx |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Model | BV200 Series |
| Wavelength | 470 nm (single-band blue LED) |
| Active Imaging Area | 170 mm × 130 mm |
| Dimensions (L×W×H) | 210 mm × 210 mm × 30 mm |
| LED Lifetime | >100,000 hours |
| Quantum Efficiency | ≥95% |
| Filter | Amber-colored cut-on filter |
| Safety Design | Eye-safe operation without UV-blocking goggles required |
| Compatible Dyes | SYBR Safe, GelRed, GelGreen, BlueView, and other non-UV nucleic acid stains |
| Brand | Clinkx |
|---|---|
| Origin | Shanghai, China |
| Model | XinPAGE Mini |
| Instrument Type | Protein Electrophoresis Apparatus |
| Gel Dimensions | 100 mm × 75 mm |
| Gel Thickness | 1.0 mm |
| Number of Gels | 1–4 |
| Compatible Pre-cast Gels | Standard stepless pre-cast gels |
| Glass Plate Size | 100 mm × 85 mm |
| Comb Options | 10-well and 15-well, 1.0 mm thickness |
| Electrode Dimensions | 1.6 mm × 1.0 mm |
| External Dimensions | 218 mm (W) × 144 mm (D) × 162 mm (H) |
| Electrode Lifespan | >100,000 mating cycles |
| Safety Compliance | GB, IEC 61010-1, EN 61010-1 |
| Brand | Clinkx |
|---|---|
| Origin | Shanghai, China |
| Model | XinPower 310 |
| Output Voltage Range | 1–600 V |
| Output Current Range | 1–1250 mA |
| Output Modes | Constant Voltage, Constant Current, Constant Power |
| Number of Output Pairs | 4 |
| Display | 5-inch IPS touchscreen (800 × 480 resolution) |
| Timer Range | 0–999 min |
| Dimensions (W×D×H) | 212 × 283 × 140 mm |
| Safety Features | Overvoltage protection, open-circuit detection, short-circuit/overload protection, leakage current monitoring, automatic micro-current hold mode post-run |
| Brand | Clinkx |
|---|---|
| Origin | Shanghai, China |
| Model | XinPower 610 |
| Instrument Type | Electrophoresis Power Supply |
| Output Channels | 4 pairs (dual independent outputs) |
| Voltage Range | 1–600 V |
| Current Range | 1–1250 mA |
| Output Modes | Constant Voltage, Constant Current, Constant Power |
| Display | 5-inch IPS TFT LCD, 800 × 480 resolution |
| Timer Range | 0–999 min |
| Dimensions (W×D×H) | 212 × 283 × 140 mm |
| Safety Features | Overvoltage, open-circuit, short-circuit, overload, and leakage current protection |
| Brand | Clinkx |
|---|---|
| Origin | Shanghai, China |
| Model | XinPower 620 |
| Output Channels | Dual Independent Outputs (4 pairs of terminals) |
| Voltage Range | 1–300 V |
| Current Range | 1–1250 mA |
| Power Mode Options | Constant Voltage, Constant Current, Constant Power |
| Timer Range | 0–999 min |
| Display | 5-inch IPS HD touchscreen (800 × 480 resolution) |
| Dimensions | 212 mm (W) × 283 mm (D) × 140 mm (H) |
| Safety Features | Overvoltage protection, open-circuit detection, short-circuit/overload protection, leakage current monitoring, automatic micro-current hold mode post-run |
| Brand | ClinkX |
|---|---|
| Origin | Shanghai, China |
| Model | XinPOWER Series |
| Instrument Type | Protein Electrophoresis Power Supply |
| Gel Dimensions Supported | 65 mm × 65 mm, 130 mm × 130 mm, 65 mm × 130 mm |
| Sample Capacity | Up to 60 samples per run |
| Output Range | 0–300 V / 0–600 mA (constant voltage or constant current mode) |
| Physical Dimensions | 300 mm × 245 mm × 100 mm (L × W × H) |
| Display | Dual-line LCD showing real-time voltage, current, power, and timer |
| Programmable Methods | 10 stored protocols, each with up to 10 sequential steps |
| Parallel Output Channels | 4 independent output ports |
| Safety Features | Overvoltage, arc detection, open-circuit & short-circuit monitoring, load transient compensation, earth-leakage protection, auto-recovery after power interruption, pause/resume function |
| Brand | Clinox |
|---|---|
| Origin | Shanghai, China |
| Model | IVScope 8200 |
| Imaging Modality | Optical (Bioluminescence & Fluorescence) |
| Camera | 6 MP, Front-Illuminated Cooled CCD (Optional Water-Cooled) |
| Cooling Temperature | Down to −90 °C |
| Lens | Motorized f/0.8 Aperture |
| Field of View | Adjustable from 10.5 cm × 8.4 cm to 23.5 cm × 18.8 cm |
| Maximum FOV | 24 cm × 24 cm |
| Spatial Resolution | 1024 × 1024 pixels |
| Minimum Exposure Time | <10 ms |
| Sample Capacity | Up to 5 Mice Simultaneously |
| Stage Temperature Control | Ambient to 42 °C |
| Illumination Sources | White Light (Reflectance), Optional UV/Visible/NIR LED Arrays & Upconversion Laser Module |
| Filter Wheel | Motorized, Supports Multiple Emission Filters |
| Software | Integrated Acquisition & Quantitative Analysis Suite with ROI-Based Radiance Calibration |
| Brand | Clinox |
|---|---|
| Origin | Shanghai, China |
| Model | IVScope 8500 |
| Imaging Modality | Bioluminescence & Fluorescence Optical Imaging |
| Camera | 1 MP Front-Illuminated Cooled CCD (Optional Water-Cooled) |
| Cooling Temperature | Down to –90 °C (with optional chiller) |
| Lens | Motorized f/0.8 Wide-Aperture Lens |
| Field of View | Adjustable from 11 cm × 11 cm to 25 cm × 25 cm |
| Maximum FOV | 24 cm × 24 cm |
| Spatial Resolution | 1024 × 1024 pixels |
| Minimum Exposure Time | <10 ms |
| Sample Capacity | Up to 5 Mice Simultaneously |
| Stage Temperature Control | Ambient to 42 °C |
| Excitation Sources | White Light (Reflectance), Optional UV/Vis/NIR LED Arrays & Upconversion Laser Module |
| Filter Wheel | Motorized, Supports Multiple Emission Filters |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Clinox |
|---|---|
| Origin | Shanghai, China |
| Model | IVScope 8500X |
| Imaging Modality | Optical (Bioluminescence/Fluorescence) + X-ray |
| Max Sample Capacity | 5 mice |
| CCD Resolution | 1024 × 1024 |
| Field of View | 11 cm × 11 cm to 25 cm × 25 cm (continuously adjustable) |
| X-ray Minimum Resolvable Feature Size | 0.16 mm |
| Lens Aperture | f/0.8 motorized auto-focus lens |
| Radiation Shielding | ≤0.5 mR/h at 5 cm from chassis wall (compliant with FDA 21 CFR 1020.40) |
| Stage Temperature Control | Ambient to 42 °C |
| Camera Type | Front-illuminated CCD (water-cooling optional) |
| Excitation Sources | White light reflectance (standard), UV/VIS/NIR reflectance & upconversion laser modules (optional) |
| Filter System | Motorized filter wheel with emission filter support |
| Anesthesia Interface | Integrated gas anesthesia delivery |
| Brand | Clinox |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XinBLOT |
| Instrument Type | Acetate Membrane Protein Electrophoresis System |
| Primary Unit | Electrophoresis Transfer Tank |
| Gel Dimensions | 100 mm × 110 mm |
| Sample Capacity | 2 transfer sandwiches |
| Input Voltage | 220 V AC |
| External Dimensions | 160 mm × 120 mm × 180 mm |
| Cooling | Dual integrated Peltier cooling modules |
| Brand | Clinox |
|---|---|
| Origin | Shanghai, China |
| Model | XinPRO Series |
| Instrument Type | Isoelectric Focusing Electrophoresis System |
| Main Unit | Vertical Electrophoresis Tank |
| Gel Dimensions | 83 mm × 73 mm |
| Sample Capacity | 60 wells |
| Input Voltage | 100–240 V AC |
| External Dimensions | 180 mm × 130 mm × 160 mm |
| Construction | Domestic Manufactured |
| Distribution Channel | Authorized Distributor |
| Brand | CLINX |
|---|---|
| Origin | Shanghai, China |
| Model | ChemiScope 6100 Touch |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 6.0 Megapixels |
| Brand | CLINX |
|---|---|
| Origin | Shanghai, China |
| Model | GenoSens 2150 |
| Camera Resolution | 5.2 MP (2540 × 2048) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.0 OD |
| Imaging Modes | UV (302/365 nm), Blue Light (470 nm), White Light, Reflected Fluorescence |
| Transilluminator Area | 211 mm × 260 mm |
| Lens | Motorized Autofocus Lens |
| Image Capture Area | 195 mm × 245 mm |
| Software | GenoSens Image Acquisition & Analysis Suite |
| Compliance | Designed for GLP-compliant workflows with audit trail-capable user account management |
| Brand | CLINX |
|---|---|
| Origin | Shanghai, China |
| Model | GenoSens 2150 Touch |
| Camera Resolution | 5.2 MP (2540 × 2048) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.0 OD |
| Imaging Area | 19.5 cm × 24.5 cm |
| UV Transillumination | 302 nm / 365 nm LED |
| Blue Light Transillumination | 470 nm LED |
| White Light Transillumination | LED |
| Reflective Fluorescence Excitation | Selectable single-wavelength LEDs (365–730 nm) |
| Emission Filters | 460–810 nm bandpass options |
| Integrated Touch Interface | 10.1″ industrial-grade capacitive touchscreen |
| Software | GenoSens Image Acquisition & Analysis Suite |
| Brand | CLINX |
|---|---|
| Origin | Shanghai, China |
| Model | GenoSens 2250 |
| Camera Resolution | 6.3 MP (3072 × 2048) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.0 OD |
| Transmission Area | 21 cm × 26 cm |
| UV Transillumination | 302 nm / 365 nm LED |
| Blue Light Transillumination | 470 nm LED |
| White Light Transillumination | LED |
| Reflected Fluorescence Excitation | 365/470/530/630/660/730 nm LEDs |
| Emission Filters | 460/525/585/690/715/810 nm |
| Image Capture Area | 19.5 cm × 30 cm |
| Dimensions (W×D×H) | 435 mm × 395 mm × 700 mm |
| Brand | CLINX |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | GenoSens 2250 Touch |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 6.3 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 4.0 OD |
| Brand | CLINX |
|---|---|
| Origin | Shanghai, China |
| Model | GenoSens S2 |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 6.37 MP (3089 × 2064 pixels) |
| Bit Depth | 16-bit |
| Lens | High-Resolution Fixed-Focal Lens |
| Imaging Area | 16 × 11.5 cm |
| UV Transillumination | 302 nm LED (17 × 13 cm active area) |
| Blue Light Transillumination | 470 nm LED (17 × 13 cm) |
| White Light Reflectance | Integrated LED |
| Filter | Multi-layer 99% UV-blocking emission filter |
| Sample Stage | Motorized adjustable stage with auto-alignment |
| Interface | USB 2.0, Wi-Fi module optional |
| Touchscreen | Embedded 10.1-inch capacitive multi-touch display |
| Dimensions (W×D×H) | 386 × 355 × 321 mm |
| Compliance | CE, RoHS, ISO 13485–compatible design for laboratory use |
| Brand | Clinx |
|---|---|
| Model | IVScope 7200 |
| Camera | 6 MP front-illuminated cooled CCD |
| Pixel Size | 4.54 µm × 4.54 µm |
| Lens Aperture | f/0.8 motorized lens |
| Cooling Temperature | down to −90 °C (with optional water-circulating chiller) |
| Sample Stage | motorized height-adjustable stage |
| Reflectance Illumination | standard white-light, optional UV/Vis/NIR |
| Filter System | optional motorized filter wheel with multiple emission filters |
| Optional Modules | RGBW high-power LED illumination system, integrated temperature & humidity control, lateral imaging module |
| Brand | Clinx |
|---|---|
| Model | IVScope 7500 |
| Camera | 1 MP back-illuminated cooled CCD |
| Pixel Size | 13 µm × 13 µm |
| Lens Aperture | f/0.8 |
| Cooling Temperature | down to −90 °C (with optional water chiller) |
| Illumination | configurable RGBW LED array (optional) |
| Environmental Control | optional integrated temperature & humidity regulation |
| Sample Stage | motorized height-adjustable platform |
| Filter System | optional motorized filter wheel |
| Imaging Modes | bioluminescence, fluorescence (UV–NIR), white-light reflectance |
| Compliance | designed for GLP-compliant plant phenotyping workflows |