| Brand | Millipore |
|---|---|
| Origin | USA |
| Configuration | Sterile, Pre-assembled Transwell-Compatible Insert System |
| Membrane Material | Polycarbonate (PCF) or Polyester (PET) |
| Pore Size | 0.4 µm (PCF) or 1.0 µm (PET) |
| Well Count | 24 |
| Format | Integrated Insert + Receiver Plate + Lid |
| Sterility | Certified Sterile, Non-Pyrogenic, DNase/RNase-Free |
| Packaging | Individual Blister Pack or Multi-Pack |
| Compliance | ISO 13485–Certified Manufacturing |
| Intended Use | In vitro cell culture, co-culture, permeability assays, differentiation studies, and barrier function analysis |
| Brand | Millipore |
|---|---|
| Origin | Japan |
| Model | BM-100 |
| Category | Imported Instrument |
| Primary Function | Automated 2D Electrophoresis Platform |
| Compliance | Designed for GLP-compliant proteomics workflows |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | NovAseptic® Magnetic Stirrer |
| Pricing | Available Upon Request |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | Scepter 3.0 |
| Measurement Time | ≤30 s per sample |
| Sample Volume | 5 µL |
| Cell Size Detection Range | 10–30 µm |
| Cell Concentration Range | 1×10⁴–1×10⁷ cells/mL |
| Throughput | Up to 100 samples per day |
| Principle | Electrical Impedance (Coulter Principle) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Model | SMCxPRO™ |
| Compliance | CE-IVD, FDA-cleared for RUO and clinical research use |
| Detection Principle | Digital immunoassay with magnetic bead-based single-molecule counting |
| Sensitivity | Sub-fg/mL (e.g., TNF-α: 0.1 pg/mL |
| IL-2 | 0.2 pg/mL |
| cTnI | 0.4 pg/mL) |
| Dynamic Range | >4 logs (up to 5–6 logs depending on analyte and assay configuration) |
| Sample Throughput | Up to 96 samples per run |
| Sample Types | Human serum, plasma, CSF, saliva, cell culture supernatant |
| Antibody Pairs Validated | >600 pre-qualified matched pairs |
| Software | SMCxPRO™ Control & Analysis Suite v3.2 (21 CFR Part 11 compliant audit trail, user role management, electronic signature support) |
| Brand | Miltenyi Biotec |
|---|---|
| Origin | Germany |
| Model | autoMACS® Pro |
| Automation Level | Fully Automatic |
| Sample Throughput | Up to 6 × 5 mL, 5 × 15 mL, or 3 × 50 mL tubes per run |
| Max Total Cells per Sample | 4 × 10⁹ |
| Max Magnetically Labeled Cells per Sample | 2 × 10⁸ |
| Sample Volume Range | 0.2–50 mL |
| Compatible Starting Materials | Whole blood, PBMCs, bone marrow, dissociated tissues, tumor digests, cultured cells (primary & cell lines) |
| Species Compatibility | Human, mouse, rat, non-human primates, and others via indirect MicroBeads |
| Column Types | Reusable autoMACS Columns (single or dual configuration) |
| Separation Modes | Positive selection, untouched isolation, depletion |
| Regulatory Compliance | Designed for GLP-compliant workflows |
| Dimensions (w × d × h) | 605 × 343 × 392.5–454 mm (with MiniSampler: 605 × 455 × 392.5–454 mm) |
| Cooling System | Integrated Chill Racks (2–8 °C sample/ reagent storage) |
| Brand | Miltenyi Biotec |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MACSima |
| Pricing | Upon Request |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Model | Vetus 9 |
| Imaging Platform | ZST+ Zone Scanning Technology |
| Core Modalities | B-mode, Color/Power Doppler, Pulsed-wave & Continuous-wave Spectral Doppler, Contrast-enhanced Ultrasound (UWN+), Shear Wave Elastography, Tissue Doppler Imaging (TDI), Tissue Tracking Quantification |
| Regulatory Status | CE Marked, FDA 510(k) cleared for veterinary use |
| Intended Use | Diagnostic imaging and functional assessment in companion animals, equine, and large animal clinical practice |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vertical Electrophoresis Tank |
| Model | miniPRO4 / miniPRO2 |
| Gel Dimensions | 83 × 73 mm |
| Gel Capacity | Up to 4 gels simultaneously |
| External Dimensions | 180 × 120 × 160 mm |
| Standard Configuration | 4 independent gel casting bases, cam-actuated alignment frame, edge-toothed combs with integrated ridge, pre-aligned glass plates with bonded sealing spacers |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Model | Mitos Dropix |
| Type | Microfluidic Droplet Coalescence Platform |
| Application Domain | Life Sciences, Synthetic Biology, High-Throughput Screening |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Model | Mitos Dropix |
| Type | Microfluidic Droplet Coalescence Platform |
| Application Domain | Life Sciences, Synthetic Biology, High-Throughput Screening |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CellXpress.ai |
| Pricing | Upon Request |
| Temperature Control | Yes |
| Humidity Control | Yes |
| Incubation Capacity | Up to 44 microplates (2 stackers) or 154 microplates (7 stackers) |
| Imaging Speed | 3.5 minutes per 96-well plate (single channel, single field of view) |
| Environmental Control | CO₂, temperature, and humidity regulation |
| Excitation Wavelengths | 7 LED sources, 365–730 nm |
| Camera Resolution | 24 MP |
| Objective Lenses | 2×, 4×, 10×, 20×, 40× |
| Imaging Channels | Brightfield + up to 6 fluorescence channels |
| AI Decision Engine | Rule-based machine learning for real-time morphological assessment |
| Air Filtration | HEPA filtration + integrated UV sterilization |
| Predefined & Custom Protocols | Yes |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GenePix 4000B |
| Instrument Type | Microarray Scanning System |
| Laser Configuration | Dual-laser (635 nm & 532 nm), Simultaneous Excitation and Detection |
| Resolution Range | 5–100 µm adjustable |
| Scan Speed | ~6.5 min per slide at 10 µm resolution (dual-channel) |
| Optical Path | Non-confocal epifluorescence |
| PMT Auto-balancing | Yes, real-time channel normalization |
| Focus Adjustment | Motorized Z-axis with manual override |
| Laser Power Control | Digitally tunable per channel |
| Calibration | Built-in NIST-traceable performance verification protocol |
| Software Integration | Native compatibility with GenePix Pro 7.x and Acuity 5.x |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ImageXpress HCS.ai |
| Pricing | Available upon Request |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | IXM-4 |
| Temperature Control | 30–40 °C ±0.5 °C |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Model | SpectraMax 190 |
| Detection Method | Absorbance (UV-Vis) |
| Automation Level | Fully Automated |
| Wavelength Range | 190–850 nm (1 nm step) |
| Minimum Bandwidth | 2 nm |
| Absorbance Range | 0–4.0 OD |
| Pathlength Correction | Patented PathCheck™ sensor (temperature-independent, converts to 1-cm equivalent) |
| Detection Channels | 8-sample + 1-reference photodiode array |
| Temperature Control | Ambient +4°C to 45°C (±0.5°C accuracy) |
| Orbital Shaking | Linear or orbital, programmable speed/amplitude |
| Microvolume Capability | SpectraDrop™ module (2 µL/sample, 64 wells/scan, dsDNA sensitivity: 2 ng/µL) |
| Software | SoftMax Pro® 7 (GLP-compliant, 21 CFR Part 11 ready, audit trail, 19 curve-fit models, custom equation editor) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Momentum |
| Instrument Type | Tomographic Imaging |
| Energy Resolution | 1.4–5.3 mT |
| Spatial Resolution | 100 µm |
| Scan Speed | 10 s per volume |
| Field of View (FOV) | 6 cm × 6 cm × 12 cm |
| Sample Capacity | 1 animal |
| Brand | Monaco |
|---|---|
| Model | MS-1 |
| Type | Manual Microplate Heat Sealer |
| Compatible Plate Formats | 96-well and 384-well microplates |
| Sealable Materials | Pressure-sensitive sealing films and adhesive films |
| Additional Compatibility | Flat-cap 8-tube strips |
| Construction | Corrosion-resistant stainless steel housing |
| Operating Principle | Manual thermal compression sealing |
| Origin | Jiangsu, China |
| Regulatory Classification | CE-compliant design for laboratory use under ISO 13485-aligned manufacturing practices |
| Brand | Monad |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | AutoDrip 1 |
| Pricing | Available Upon Request |
| Dispensing Range | 5–2000 µL |
| Precision & Accuracy | <3% CV and %Error (per ISO 8655-6) |
| Calibration | Dual-point volumetric calibration (low/high range) |
| Compatible Plate Formats | 24-well, 48-well, 96-well microplates |
| Pump Technology | Dual-head peristaltic pump system |
| Included Tubing Sets | Five pre-calibrated disposable tubing paths (GLA9005–GLA9009) |
| Standard Accessories | Small nozzle holder (GLA9001), large nozzle holder (GLA9002), small-pump calibrator (GLA9003), spare small-nozzle gaskets (5/pk, GLA9004) |
| Brand | Monad |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BlotEZ |
| Pricing | Available Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MOST 9000 |
| Pricing | Upon Request |
| Brand | Motic |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EasyScan 6 |
| Pricing | Available Upon Request |
| Objective Lenses | Plan Apochromatic 20×/0.75 and 10×/0.3 |
| Autofocus Technology | Real-time Auto Focus |
| Scan Modes | Standard (Real-time AF), High-Precision AF, Extended Depth of Field (EDF), Z-Stack (Multi-layer Z-direction Scanning) |
| Imaging System | Triple-Camera Architecture |
| Scan Camera | 5 MP, 2/3″ High-Speed CMOS Sensor |
| Pixel Resolution | 0.26 µm/pixel at 40×, 0.52 µm/pixel at 20× |
| Objective Turret | 3-Position |
| Illumination | 10 W LED (25,000 h lifetime) |
| Slide Capacity | 6 slides per batch |
| Slide Dimensions | 76 × 26 mm (tolerance: −0/+1 mm in length, −0/+1 mm in width) |
| Standard Software | EasyScanner, DSAssistant (DSServer optional) |
| Brand | Motic |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MV200 |
| Instrument Type | Inverted Microscope |
| Optical Design | Plan Phase Contrast Objective with Multi-layer Broadband Coating |
| Tube Lens | Fully Achromatically Corrected |
| Illumination | Integrated 12 V / 3 W LED |
| Condenser | Adjustable Aperture Diaphragm (N.A. 0.1–0.3) |
| Digital Integration | Built-in Digital Imaging Options (MV200-B, MV200-D, MV200-i, MV200-S variants) |
| Application Focus | Live-cell Observation, Tissue Culture, Microbiology, Immunology, Medical Education |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Microfluidic Chip System |
| Model | MPI-M |
| Pricing | Upon Request |
| Key Specifications | Dynamic Range > 5 decades |
| Emission Wavelength Detection Range | 300–650 nm |
| Photometric Sensitivity | SP > 1000 A/lm |
| High-Voltage Power Supply | 4-channel, 0–2000 V per channel, 0–2 mA per channel, 10-step programmable sequencing, selectable output modes (output / disconnect / ground), current-limiting protection |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | MPI-P |
| Instrument Category | Microfluidic Chip System |
| Electrochemical Analyzer Specifications | Potential Range: ±10 V |
| Current Range | ±250 mA |
| Reference Electrode Input Impedance | 10¹² Ω |
| Sensitivity | 1×10⁻¹² A to 0.1 A (16 decades) |
| Input Bias Current | <50 pA |
| Potential Increment | 1 mV |
| Scan Rate | 1×10⁻⁴ to 200 V/s |
| Supported Techniques | Cyclic Voltammetry (CV), Linear Sweep Voltammetry (LSV), Chronoamperometry (CA), Chronocoulometry (CC), Bulk Electrolysis (BE), Open Circuit Potential vs. Time (OCPT) |
| High-Voltage Power Supply | 4 Channels, 0–2000 V per channel, 0–2 mA per channel, Programmable Output Mode (Output/Disconnect/Ground), Current-Limit Protection (0–2 mA), 10-Step Program Sequence |
| Brand | X-Imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | mRNA Synthesis Automation System |
| Pricing | Available Upon Request |
| Brand | POWCLIN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MSFLO |
| Pricing | Upon Request |
| Technology Platform | Mass Cytometry (ICP-TOF) |
| Instrument Type | Flow Cytometer for Single-Cell Metal Isotope Detection |
| Primary Use Case | Academic & Translational Research |
| Brand | MSHOT |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MCS21 |
| Pricing | Upon Request |
| Imaging Modes | Brightfield, Phase Contrast, Fluorescence (Dual-Channel: Blue 475/30 nm & Green 560/40 nm) |
| Light Source | 625 nm Red LED for Phase Contrast |
| Objective | 10×/0.25 Phase Contrast |
| Z-Axis Focus | Motorized Autofocus |
| Camera | 5 MP, 2/3" CMOS, 40 fps |
| Software Architecture | Client/Server (C/S), Remote Control Enabled |
| Environmental Range | 5–42 °C, 5–95% RH |
| Power & Data | USB + DC Input |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MSZ-1 |
| Pricing | Upon Request |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MTS-1 |
| Pricing | Upon Request |