| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tankblot Eco-Maxi |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tankblot Eco-Mini |
| Pricing | Available Upon Request |
| Brand | Tanon |
|---|---|
| Origin | Shanghai, China |
| Model | EPS-200 |
| Output Channels | 4 independent |
| Voltage Range | 5–200 V |
| Current Range | 10–2000 mA |
| Timer Range | 0–999 min |
| Display | 3-digit LED (voltage/current) + 1-digit status indicator |
| Protection | Auto no-load cutoff, over-current & short-circuit protection |
| Memory Function | Yes |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Brand | Tanon |
|---|---|
| Model | EPS-600 |
| Output Channels | 4 independent |
| Voltage Range | 5–600 V |
| Current Range | 5–800 mA |
| Timer Range | 0–999 min |
| Display | 3-digit LED (voltage/current) + 1-digit status indicator |
| Protection | Auto no-load cutoff, over-current & short-circuit protection |
| Memory | Last-used parameter retention |
| Compliance | CE-marked for laboratory use in accordance with IEC 61010-1 |
| Brand | Tanon |
|---|---|
| Origin | Shanghai, China |
| Model | HE-220 |
| Maximum Gel Area | 18.5 × 12 cm |
| Gel Tray Dimensions | 18.5 × 12 cm |
| Comb Configuration | 25-well molded comb |
| External Dimensions (L×W×H) | 31 × 17.5 × 8 cm |
| Compatible Power Supplies | EPS-100, EPS-200, EPS-300, EPS-600 |
| Brand | Tanon |
|---|---|
| Origin | Shanghai, China |
| Model | VE-180 |
| Gel Area | 8.3 × 7.3 cm |
| Spacing Options | 0.75 mm, 1.0 mm, 1.5 mm |
| Max Gels per Run | 2 |
| Outer Buffer Capacity | 750 mL |
| Inner Buffer Capacity | 130 mL |
| Dimensions (L×W×H) | 16 × 11.5 × 15 cm |
| Compatibility | Standard Mini-Pre-Cast Gels (e.g., Bio-Rad Mini-PROTEAN®, Thermo Fisher Novex®, Lonza NuPAGE®) |
| Brand | Tanon |
|---|---|
| Origin | Shanghai, China |
| Model | VE-580 |
| Gel Area (per gel) | 8.6 × 8 cm |
| Max Operating Voltage | 250 V |
| Compatible Gel Formats | 1–4 gels (10 × 10 cm casting frame) |
| Comb Options | 10-, 15-, and 17-well combs |
| Construction | Reinforced borosilicate glass plates with scratch-resistant coating |
| Base Design | Dual-circuit isolated power interface |
| Electrode Configuration | Dual independent electrode arrays |
| Cooling | Passive convection via V-groove side vents |
| Compliance | Designed for ISO/IEC 17025-aligned lab workflows, compatible with GLP documentation requirements |
| Brand | Tanon |
|---|---|
| Model | VE-586 |
| Type | Semi-Dry Transfer Electrophoresis Cell |
| Origin | Shanghai, China |
| Compatible Power Supply | EPS-200 / EPS-300 / EPS-600 |
| Compatible Vertical Electrophoresis Units | VE-680 / VE-180 |
| Max Gel Capacity | 4 × standard mini-gels (e.g., 8.5 × 7.5 cm) |
| Electrode Design | Patented perforated electrode frame |
| Cooling | Passive heat dissipation via optimized electrode geometry and open-frame architecture |
| Accessories Supported | 586-1700 transfer filter paper, VE-10 single-well antibody incubation box, VE-110 multi-well antibody incubation box |
| Compliance | Designed for routine laboratory use in accordance with standard molecular biology workflows per ISO/IEC 17025-aligned practices |
| Brand | TATUNG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | THI-150 / THI-250 |
| Heating Method | Air-jacketed |
| Cooling Method | Compressor-based |
| Humidification Water Reservoir | External |
| Temperature Range (with Humidification) | 4–60 °C |
| Temperature Range (without Humidification) | 0–60 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±2.0 °C |
| Humidity Range | 55–90 %RH |
| Humidity Accuracy | ±5 %RH |
| Chamber Capacity | 250 L |
| External Dimensions (W×D×H) | 635 × 665 × 1765 mm |
| Brand | TCT (Xiamen Tongchuang) |
|---|---|
| Origin | Fujian, China |
| Instrument Type | Fully Automated |
| Detection Method | NDIR (CO₂, CH₄), NDUV (H₂S), Electrochemical or PMD Paramagnetic (O₂) |
| Measured Gases | CO₂, O₂, CH₄, H₂S |
| Accuracy | ≤ ±1.5% of reading or ±0.2% FS (CO₂/CH₄), ≤ ±1.5% of reading or ±1% FS (H₂S) |
| Zero Drift | CO₂ ≤ ±0.1%/8h |
| Span Drift | CO₂ ≤ ±0.1% FS/8h |
| Repeatability | CO₂ ≤ ±1% FS |
| Linearity | 0.99 ≤ slope ≤ 1.01 |
| Response Time (T90) | < 3 s (at inlet) |
| Sampling Frequency | 1 Hz |
| Gas Conditioning | Integrated electronic cooler (4–5°C), particulate filter, flow meter, condensate detection |
| Output | Standard Modbus RTU (RS-485), optional analog (0–5 V / 4–20 mA) |
| Channels | Configurable 1–12 multi-tank sequential sampling |
| Dimensions (W×H×D) | 450 mm × 370 mm × 310 mm |
| Weight | ~20 kg (EC-4 configuration) |
| Operating Temperature | 5–45 °C |
| Storage Temperature | −25 to +65 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Power Supply | 230 V AC |
| Warm-up Time | < 1 h (at 20 °C) |
| Ingress Protection | IP20 |
| Brand | TCT |
|---|---|
| Model | Ferment500 |
| Origin | Fujian, China |
| Instrument Type | Fully Automatic |
| Detection Method | Gas Sensing (Thermal Conductivity for CO₂ |
| Measured Parameters | CO₂, O₂, CER, OUR, RQ |
| Accuracy | ≤ ±1.5% FS |
| Sampling Frequency | ≥1 Hz |
| Dimensions | 355 mm × 195 mm × 436 mm |
| Channel Architecture | Four Independent Physical Channels with Dedicated Sensors |
| Environmental Compensation | Integrated Temperature, Humidity & Pressure Compensation |
| Gas Pre-treatment | Built-in Condensation-Based Moisture and Foam Removal System |
| Display | High-Resolution Touchscreen LCD |
| Calibration | Per-Channel Single-Point Calibration |
| Connectivity | Optional Ethernet/Wi-Fi with OTA Firmware Updates, Remote Diagnostics, Alarm Notification, Predictive Maintenance Logging |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | MagicPrep NGS |
| Intended Use | Research Use Only (RUO) |
| Automation Level | Fully Integrated, Walk-Away Operation |
| Platform Compatibility | Illumina Sequencing Platforms |
| Throughput | Up to 96 samples per run |
| Setup Time | <10 minutes |
| Library Prep Workflow | Fragmentation, End Repair, A-Tailing, Adapter Ligation, PCR Amplification, Cleanup |
| Success Rate | >99% (based on internal validation studies under controlled lab conditions) |
| Regulatory Status | Not for clinical diagnostic use |
| Compliance | Designed in accordance with ISO 13485-aligned quality system principles for RUO instrumentation |
| Brand | TECAN |
|---|---|
| Origin | USA |
| Model | Uno |
| Type | Fully Automated Benchtop System |
| Sample Volume | 20 µL |
| Throughput | 400 cells per run |
| Temperature Control | Ambient |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hybrigene HB-3D |
| Price | Upon Request |
| Brand | Telstar |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Custom-Built |
| Instrument Type | Class III Biological Safety Cabinet |
| External Dimensions (L×W×H) | Customizable |
| Internal Dimensions (L×W×H) | Customizable |
| Filter Efficiency (HEPA/ULPA) | ≥99.999% at 0.12 µm |
| Brand | Telstar |
|---|---|
| Origin | Spain |
| Model | Telstar Pura 2, Pura 3, Pura 4, Pura 3+, Pura 4+ |
| Air Classification | ISO Class 5 (EU GMP Grade A) in all chambers |
| Airflow | Unidirectional laminar flow (certified per ISO 14644-1) |
| Illumination | 700 lux (test chamber), 300 lux (transfer chamber) |
| Noise Level | <70 dBA |
| Inlet Filtration | HEPA H14 (99.997% @ 0.3 µm) |
| Exhaust Filtration | HEPA H14 (99.997% @ 0.3 µm) |
| Pre-filter | E10 |
| Bio-decontamination Efficacy | ≥6-log reduction of Geobacillus stearothermophilus spores |
| Sterility Test Pump | Integrated with standard Millipore (Merck) or Sartorius filtration units |
| Non-viable Particle Monitoring | APEX P5 portable airborne particle counter (dual-channel, 0.3/0.5 µm, 3000-record memory, 3.5" color touchscreen, stainless steel 304 housing) with LMS Express software (21 CFR Part 11 compliant) |
| Viable Microbial Monitoring | Sartorius MD8 airscan with gelatin membrane filtration |
| H₂O₂ Monitoring | In-chamber single-channel sensor (0–300 ppm) |
| Validation Support | FAT/SAT/DQ/IQ/OQ/PQ documentation templates available |
| Service | Global technical support via Telstar UK |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 3350 |
| Certification | DIN EN 12830:2018 |
| Communication | WLAN, LAN, testo UltraRange radio |
| Alarm | Visual LED alert (flashing) |
| Software Integration | testo Saveris PRO / CFR, testo Saveris Cockpit |
| Compliance | Supports 21 CFR Part 11 audit trail and GLP/GMP workflows |
| Power | Battery-operated (included) |
| Display | Built-in LCD |
| Sensor Type | Integrated NTC temperature sensor |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1751 |
| Measurement Range | -35 °C to +55 °C |
| Accuracy | ±0.5 °C (-35 °C to +55 °C) ±1 digit |
| Resolution | 0.1 °C |
| Memory Capacity | 1,000,000 readings |
| Battery Life | Up to 3 years (15-min interval, +25 °C) |
| Power Supply | 3 × AAA alkaline batteries |
| Protection Rating | IP65 |
| Dimensions | 89 × 53 × 27 mm |
| Weight | 130 g |
| Interface | Mini-USB port & SD card slot |
| Compliance | EN 12830, HACCP, EU Directive 2014/30/EU (EMC), RoHS 2011/65/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1753 |
| Temperature Range | −50 °C to +1000 °C (Type K), −50 °C to +400 °C (Type T) |
| Accuracy | ±0.5 °C (−50 to +70 °C), ±0.7 % of reading (+70.1 to +1000 °C for K |
| Resolution | 0.1 °C |
| Memory Capacity | 1,000,000 readings |
| Battery Life | Up to 3 years (15-min interval, +25 °C) |
| Power Supply | 3 × AAA alkaline batteries |
| IP Rating | IP65 |
| Dimensions | 96 × 54 × 29 mm |
| Weight | 130 g |
| Operating Temperature | −20 °C to +55 °C |
| Storage Temperature | −20 °C to +55 °C |
| Measurement Interval | 10 s – 24 h |
| Compliance | EU Directive 2014/30/EU (EMC), 2011/65/EU (RoHS) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1843 |
| Measurement Range | −35 to +70 °C |
| Accuracy | ±0.5 °C |
| Resolution | 0.1 °C |
| Response Time (t₉₀) | 30 min |
| Logging Interval | 1 min to 24 h |
| Memory Capacity | 40,000 readings |
| Battery Life | 500 days (at 25 °C, 15-min interval) |
| Weight | 44 g |
| Dimensions | 97 × 12 × 40 mm (L×W×H) |
| Enclosure Material | ABS |
| IP Rating | IP67 |
| Display | Single-line segment LCD |
| Interface | USB Type-A, NFC |
| Compliance | EN 12830, CE 2014/30/EU, DIN EN 61326-1:2013, DIN EN 50581:2013, FDA 21 CFR Part 11 (with testo ComSoft CFR software), HACCP, GxP |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0554 1901 |
| Compliance | 21 CFR Part 11 compliant software platform |
| System Requirements | Windows 7 (32/64-bit), Windows 8, Windows 10 or newer |
| Included Software | testo 190 CFR Software (locally installed, registration required) |
| Maximum Simultaneous Loggers | 8 (programming & readout), 254 (validation-scale data aggregation) |
| Key Functionality | F₀ calculation, photo-annotation of measurement locations, graphical + tabular data visualization, audit-trail-enabled reporting |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 190-P1-CFR |
| Absolute Pressure Range | 1 mbar to 4 bar abs |
| Accuracy | ±20 mbar |
| Resolution | 1 mbar |
| Response Time (t₉₀) | 0.2 s |
| Memory Capacity | 60,000 measurements |
| Measurement Interval | 1 s – 24 h |
| Operating Temperature | 0 – 140 °C |
| Storage Temperature | −20 – +50 °C |
| Housing Material | Stainless steel body with PEEK battery cap |
| Ingress Protection | IP68 |
| Battery | 1/2 AA lithium |
| Battery Life | 2,500 operating hours (10 s cycle at +121 °C) |
| Dimensions | Ø22 × 83 mm |
| Channel Count | 1 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 191 |
| Type | Integrated Temperature Validation System for Sterilization, Pasteurization & Lyophilization Processes |
| Compliance | Designed for HACCP, FDA 21 CFR Part 11 (with optional audit trail), ISO/IEC 17025-supporting workflows, EN 12830, ASTM F1783, and EU Annex 15 (Qualification of Aseptic Processes) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 191-P1-HACCP |
| Absolute Pressure Range | 1 mbar to 4 bar abs |
| Accuracy | ±20 mbar |
| Resolution | 1 mbar |
| Response Time (t₉₀) | 0.2 s |
| Operating Temperature | 0 °C to 140 °C |
| Storage Temperature | −20 °C to +50 °C |
| IP Rating | IP68 |
| Dimensions | Ø22 mm × 83 mm |
| Battery | 1/2 AA lithium |
| Battery Life | 2,500 h (at 10 s measurement interval, +121 °C) |
| Memory Capacity | 60,000 measurements |
| Measurement Interval | 1 s to 24 h |
| Interface | USB |
| Enclosure Material | Stainless steel housing with PEEK battery cap |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 191-T2 HACCP |
| Measurement Range | −50 to +140 °C |
| Accuracy | ±0.2 °C (−50 to −40 °C), ±0.1 °C (−40 to +140 °C) |
| Resolution | 0.01 °C |
| Probe Length | 115 mm |
| Probe Diameter | 3 mm |
| Housing Diameter × Height | 20 × 59 mm |
| IP Rating | IP68 |
| Sensor Type | Pt1000 |
| Response Time t₉₀ | 6 s |
| Memory Capacity | 60,000 readings |
| Battery | 1/2 AA lithium |
| Battery Life | 2,500 h (10 s interval at +121 °C) |
| Operating Temperature | −50 to +140 °C |
| Storage Temperature | −20 to +50 °C |
| Measurement Interval | 1 s to 24 h |
| Certifications | CE |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1914 |
| Measurement Principle | Pt1000 Resistance Thermometry |
| Temperature Range | –50 to +140 °C |
| Accuracy | ±0.2 °C (–50 to –40 °C), ±0.1 °C (–40 to +140 °C) |
| Resolution | 0.01 °C |
| Response Time t₉₀ | 6 s |
| Probe Length | 775 mm |
| Probe Diameter | 1.5 mm |
| Housing Diameter × Height | 20 × 72 mm |
| IP Rating | IP68 |
| Battery | 1/2 AA lithium |
| Operating Life | 2,500 h (10 s measurement interval at +121 °C) |
| Memory Capacity | 30,000 readings per channel |
| Enclosure Material | Stainless steel housing with PEEK-coated battery cap |
| Compliance | CE-marked, designed for HACCP-critical thermal validation |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 3163 |
| Operating Temperature | −18 to +50 °C |
| Storage Temperature | 0 to +50 °C |
| Relative Humidity Range | 20–80 % RH |
| Weight | 500 g (incl. batteries) |
| Dimensions | 270 × 60 × 61 mm |
| Detectable Refrigerants | R22, R134a, R404A, R410A, R507, R438A, and all CFCs, HCFCs, HFCs |
| Sensitivity | 4 g/year (0.15 oz/year) |
| Sensor Lifetime | 80–100 h (~1 year of typical field use) |
| Battery Type | 2 × D cells |
| Continuous Operation Time | ~16 h |
| Compliance | EN 14624:2012, SAE J1627, EU Directive 2004/108/EC, F-Gas Regulation (EU) No. 517/2014 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 3164 |
| Detection Sensitivity | < 3 g/year (per EN 14624:2012) |
| Operating Temperature | −20 °C to +50 °C |
| Storage Temperature | −25 °C to +70 °C |
| Relative Humidity Range | 20–80 % RH |
| Weight | 348 g |
| Dimensions (L × W × H) | 190 × 57 × 42 mm |
| Gooseneck Length | 370 mm |
| Response Time | < 1 s |
| Warm-up Time | < 50 s (at 0–50 °C) |
| Battery | Integrated NiMH battery pack (6 cells), ~6 h continuous operation |
| Detectable Refrigerants | R134a, R22, R404A, H₂, CFCs, HCFCs, HFCs |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 4770 |
| Measurement Range | 30–300,000 fpm (flashes per minute) |
| Flash Intensity | up to 4800 lux @ 30 cm / 6000 fpm |
| Flash Duration | Adjustable |
| Display | LCD |
| Protection Rating | IP65 |
| Battery Life | ~11 h (NiMH rechargeable, at 6000 fpm) / ~5 h (alkaline, at 6000 fpm) |
| Accuracy | ±0.02 % of reading |
| Resolution | ±0.1 fpm (30–999 fpm), ±1 fpm (1000–300,000 fpm) |
| Trigger I/O | Yes |
| Flash Color Temperature | ~6500 K |
| Operating Current | ≤50 mA |
| Low-Voltage Cutoff | <1 V |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 0550 |
| Pressure Range | –1 to +60 bar (rel.) |
| Pressure Accuracy | ±0.5 % FS |
| Pressure Resolution | 0.01 bar |
| Temperature Range | –50 to +150 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Inputs | 2 × NTC plug-in ports |
| Pressure Ports | 3 × 7/16"–UNF |
| Max. Overpressure (HP) | 65 bar |
| Vacuum Range | –1 to 0 bar |
| Weight | 1060 g |
| Dimensions | 200 × 109 × 63 mm |
| Operating Temperature | –20 to +50 °C |
| IP Rating | IP42 |
| Refrigerants Stored | 60 preloaded |