Life Science Instruments
Filter
Showing 2311–2340 of 7558 results
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | MPC-5V226 |
| Price Range | USD 7,000–14,000 (FOB) |
| Temperature Range | 2–8°C |
| Effective Volume | 236 L |
| Internal Dimensions | 534 × 406 × 1150 mm |
| External Dimensions | 625 × 574 × 1707 mm |
| Cooling Method | Forced-air (Fan-cooled) |
| Temperature Uniformity | ±0.5°C (at 5°C setpoint, steady-state, per IEC 61000-4-2) |
| Temperature Monitoring | Dual Pt100 sensors with independent alarm circuitry |
| Door | Single, self-closing, magnetic gasket-sealed, lockable with key |
| Brand | Duling |
|---|---|
| Model | MPC-5V306 |
| Type | Vertical Pharmaceutical Refrigerator |
| Temperature Range | 2°C to 8°C (±1.5°C uniformity) |
| Effective Volume | 306 L |
| Internal Dimensions (W×D×H) | 540 × 425 × 1380 mm |
| External Dimensions (W×D×H) | 640 × 580 × 1920 mm |
| Net Weight | 104 kg |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 240 W |
| Energy Consumption | 3.9 kWh/24h |
| Noise Level | ≤50 dB(A) |
| Climate Class | SN/N |
| Refrigeration Method | Forced-air convection (fan-cooled) |
| Insulation | CFC-free high-density polyurethane foam |
| Compressor | Single imported unit |
| Refrigerant | Eco-friendly non-ozone-depleting refrigerant |
| Door | Single double-glazed tempered glass door with inert gas fill, anti-condensation heating film, and auto-closing mechanism |
| Shelving | 4 adjustable powder-coated wire shelves with label strips |
| Casters | 4 (2 swivel with brakes + 2 leveling feet) |
| Data Logging | Built-in 5-year temperature history storage, USB export, optional external温湿度 recorder interface |
| Alarms | Dual-mode (audible buzzer + visual LED), covering high/low temperature, door open, power failure, voltage anomaly, condenser blockage, ambient temperature deviation, controller fault, low backup battery |
| Safety Compliance | ISO 13485, ISO 9001, ISO 14001, OHSAS 18001, CE, China NMPA Medical Device Registration & Manufacturing License |
| Warranty | 36 months comprehensive |
| Brand | Duling |
|---|---|
| Model | MPC-5V515D |
| Temperature Range | 2°C to 8°C |
| Net Capacity | 515 L |
| Internal Dimensions (W×D×H) | 595 × 641 × 1475 mm |
| External Dimensions (W×D×H) | 695 × 794 × 1993 mm |
| Cooling Method | Forced-air (Fan-cooled) |
| Compressor Configuration | Dual independent refrigeration systems |
| Insulation | CFC-free high-density polyurethane foam |
| Door Type | Light-blocking, high-density insulated door with magnetic gasket |
| Control Interface | 7-inch capacitive touchscreen |
| Access Control | Fingerprint, RFID card, PIN code, and mechanical key backup |
| Alarm System | Audible & visual alerts for temperature deviation, sensor failure, power outage, door open duration, condenser overheating, ambient temperature exceedance |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 294 W |
| Climate Class | SN/N |
| Net Weight | 140 kg |
| Shelving | 6-tier configuration (2 wire shelves + 4 pull-out drawers) |
| Enclosure Material | Powder-coated steel (interior & exterior) |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Model | MPC-5V650Y |
| Cooling Method | Forced-air (Fan-cooled) |
| Temperature Range | 8°C to 20°C |
| Net Capacity | 650 L |
| Internal Dimensions (W×D×H) | 1100 × 454 × 1325 mm |
| External Dimensions (W×D×H) | 1220 × 630 × 1885 mm |
| Net Weight | 158 kg |
| Rated Power | 137 W |
| Climate Class | SN/N |
| Power Supply | 220 V / 50 Hz |
| Door | Double-glazed tempered glass with LOW-E coating |
| Shelving | 5 adjustable shelves (10 shelf panels total), labeled with identification strips |
| Insulation | CFC-free high-density polyurethane foam |
| Compressor | 1 unit, industrial-grade hermetic compressor from internationally recognized manufacturer |
| Alarm System | Audible and visual alarms for temperature deviation (high/low), humidity deviation (high/low), sensor failure, and door-open anomaly |
| Lighting | Integrated LED cold-light source |
| Door Mechanism | Self-closing with automatic rebound function |
| Locking | Dual concealed mechanical locks |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Model | MRF-25V368 / MRF-40V368 |
| Configuration | Upright Dual-Zone Cabinet |
| Total Effective Volume | 368 L (Refrigeration Zone: 189 L |
| Freezing Zone | 179 L) |
| Interior Dimensions (mm) | Refrigeration Zone 580 × 626 × 625 |
| External Dimensions (mm) | 720 × 830 × 1870 |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 300 W |
| Energy Consumption | 3.40 kWh/24h |
| Net Weight | 130 kg |
| Climate Class | SN/N |
| Refrigeration Method | Air-Cooled (Refrigeration Zone) |
| Temperature Ranges | Refrigeration Zone: +2 °C to +8 °C |
| Freezing Zone | −10 °C to −25 °C (MRF-25V368) or −40 °C (MRF-40V368) |
| Operating Ambient Temperature | 10 °C to 32 °C |
| Brand | DUONING |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DuoFill |
| Pricing | Available Upon Request |
| Brand | Duoning Bio |
|---|---|
| Origin | Shanghai, China |
| Model | 0720-0001 |
| Instrument Type | Refrigerated CO₂-Controlled Orbital Shaker |
| Temperature Range | 4°C to 60°C (up to 18°C below ambient) |
| Temperature Uniformity | ±0.5°C @ 37°C |
| CO₂ Range | 0–20% (IR sensor) |
| Speed Range | 0.3–300 rpm |
| Speed Accuracy | ±1 rpm |
| Orbit Diameter | φ50 mm |
| Timer Range | 0–999 h 59 min |
| Programmable Stages | 12-segment ramp/soak profile |
| Display | 10-inch capacitive color touchscreen |
| Noise Level | ≤53 dB(A) |
| Max Load per Shelf | 10 kg |
| Shelf Dimensions | 570 × 470 mm |
| Internal Chamber Dimensions | 654 × 605 × 299 mm |
| External Dimensions (H×W×D) | 970 × 780 × (530 + 80 mm foot height) mm |
| Weight | 170 kg |
| Power Supply | AC 220 V ±22 V, 50/60 Hz |
| Max Capacity | 15 × 3 L flasks |
| Humidity Control | Integrated auto-humidification |
| Defrost Mode | Automatic cycle-based defrost |
| UV Sterilization | Built-in 254 nm UV-C lamp |
| Drive System | Brushless magnetic drive (belt-free) |
| Connectivity | Optional Wi-Fi module with multi-user remote monitoring & alarm push notifications |
| Data Logging | On-device 7-day history |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Dust Generator |
| Pricing | Upon Request |
| Brand | DAWEI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DW-16 |
| Price Range | USD 1,400 – 7,000 |
| Compatible Petri Dish Diameter | 90 mm (standard, with base OD 87 mm, lid OD 89–90 mm) |
| Drive Mechanism | Motorized rotary platform |
| Speed Control | 4-step adjustable (200–350 rpm) |
| Construction Material | Corrosion-resistant metal alloy housing |
| Liquid Containment | Integrated spill-resistant sealing design |
| Sterilization Compatibility | Ethanol wipe, 70% isopropanol, and UV irradiation (254 nm) |
| Accessories Included | 1 × instrument host, 1 × dish alignment ring, 1 × power cord |
| Optional Consumables | Stainless steel or disposable sterile spreaders (user-supplied) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DW-40L262 |
| Pricing | Available Upon Request |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | DEX |
| Measurement Principle | Resistive Strain-Bridge Displacement Sensing with Integrated Temperature Compensation |
| Operating Temperature Range | –10 to 50 °C |
| Accuracy | ±0.050 mm (for ΔT > 20 °C) |
| Temperature Stability | 0.0025 mm/°C |
| Output Signal | Analog ±5 mV or ±2.5 mV (model-dependent) |
| Sensitivity | 0.05–0.5 mV/mm |
| Linearity Error | ±0.004 to ±0.01 mV/mm |
| Electrical Noise | ±0.01 mV |
| Compatible Data Loggers | Supports up to 8 or 32 sensors per system |
| IP-Rated Enclosure | Sealed Electronics for Outdoor & Field Deployment |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | EXO-Skin™ |
| Sensor Type | Heat-Balance-Based Wrap-Around Sap Flow Sensor |
| Diameter Range | 9.5–25 mm |
| Height | 70–120 mm |
| Input Voltage | 4.5 V DC |
| Typical Power Consumption | 0.13–0.48 W |
| Thermocouple Pairs | 2 per unit |
| Enclosure | PTFE-Composite Vapor-Permeable Waterproof Membrane |
| Mounting | Velstretch® Elastic Nylon Band (Breathable, Hydrophobic, Growth-Accommodating) |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | FLGS-TDP |
| Data Logger Memory | 4 MB standard (expandable to 16 GB microSD) |
| Storage Capacity | 400 days at 1-hour interval |
| Input Channels | 32 differential analog inputs |
| Max Probe Support | 128 × TDP10/30/50, 64 × TDP80, or 40 × TDP100 |
| Temperature Accuracy | ±0.03 °C |
| Temperature Resolution | 0.0083 °C |
| AVRD Voltage Regulation | 4 channels (1.5–10 V, 5 A each) |
| System Dimensions | 45 × 35 × 16 cm |
| Weight | 11.5 kg |
| Power Supply | Dual-voltage AC adapter (110–220 V, 50–60 Hz, 4.5 A) |
| Standard Cable Length | 3 m (extendable to 22.8 m) |
| Compliance | Designed for long-term field deployment under GLP-aligned environmental monitoring protocols |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Flow32-1K |
| Pricing | Upon Request |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | Flow32-1K |
| Power Supply | 12 V rechargeable lead-acid battery (7 Ah) |
| Data Storage | 4 MB internal (expandable to 16 GB via microSD) |
| Channel Capacity | Up to 32 differential analog input channels |
| Sensor Compatibility | 14 sizes of Dynagage wrap-around stem flow sensors (stem diameter range: 2.1–165 mm) |
| Voltage Regulation | Dual AVRD modules, 1.5–10 V adjustable, 5 A per channel |
| Input Resolution | 0.05–0.88 µV |
| Input Range | ±200–5000 mV |
| Communication | Micro-B USB, Ethernet |
| Enclosure | Fiberglass weatherproof cabinet (43 × 35 × 16 cm), 11.5 kg |
| Operating Mode | AVRD adaptive power-saving mode with automatic Ksh zero-point recalibration |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | HCFM-XP Gen3 |
| Measurement Diameter Range | 1–36 mm |
| Flow Rate Range | 0.01–350 g/h (5 selectable ranges) |
| Hydraulic Conductance Range | 7.7×10⁻⁸ to 3.5×10⁻⁴ kg·s⁻¹·MPa⁻¹ |
| Pressure Output Resolution | 0.1 kPa |
| Max Operating Pressure | 620 kPa |
| Deaerated Water Reservoir Capacity | 0.7 L |
| Compressed Gas Cylinder Capacity | 170 L (at STP), CGA-580 valve |
| Data Acquisition | 1 reading per 2 s |
| A/D Conversion | 24-bit dual analog/digital |
| Dimensions (L×W×H) | 61×48×23 cm |
| Weight | 15 kg |
| Power & Interface | USB-powered, integrated data logging |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | HPFM-Gen3 |
| Pressure Range | 0–630 kPa |
| Flow Rate Range | 0.7–2500 g/h (6 full-scale ranges) |
| Hydraulic Conductance Range | 7.7×10⁻⁸ to 2.2×10⁻³ kg·s⁻¹·MPa⁻¹ |
| Sampling Interval | 1 reading per 2 s |
| A/D Resolution | 24-bit dual analog-to-digital conversion |
| Dimensions | 33 × 31 × 52 cm |
| Weight | 12 kg (excluding pressure vessel) |
| Deaerated Water Capacity | 8 L |
| Power & Interface | USB-powered, no external power supply required |
| Operating Systems | Windows XP, Vista, Windows 7 |
| Compliance | NIST-traceable calibration, GLP-compliant data acquisition architecture |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | SapIP Monitoring Network |
| Node-to-Node Range | 300–500 m |
| Onboard Storage | 30,000 Records per Node |
| Compliance | Designed for Field-Deployable Ecophysiological Research under GLP-Aligned Data Integrity Practices |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | SGDC |
| Type | Heat Balance-Based Stem Flow Sensor |
| Compliance | Validated per USDA-ARS protocols (Lascano et al., 2016, *Agric. Sci.*) |
| Channel Requirement | 2 differential analog inputs (temperature + heater voltage/current) |
| Stem Diameter Range | 7–25 mm (model-dependent) |
| Enclosure Design | EXO-Skin conformal wrap |
| Heater Architecture | Molded, low-thermal-mass resistive element |
| Environmental Protection | IP67-rated moisture barrier |
| Calibration Traceability | NIST-traceable thermistor and voltage references |
| Brand | Dynamica |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DynaCell190i |
| Price Range | USD 7,800–10,000 (FOB) |
| Instrument Type | Air-jacketed CO₂ Incubator |
| CO₂ Detection | Infrared (IR) Sensor |
| Temperature Control Range & Accuracy | Ambient +5°C to 50°C, ±0.1°C (at setpoint) |
| Temperature Uniformity | ±0.3°C at 37°C |
| CO₂ Concentration Control Range & Accuracy | 0–20% vol., ±0.1% (full scale) |
| Humidity Control Range & Accuracy | 20–95% RH, ±3% RH (measured at 37°C, 5% CO₂) |
| Chamber Capacity | 190 L |
| External Dimensions (W×D×H) | 720 × 694.5 × 890 mm |
| Standard Configuration | Dual-stage HEPA filtration (0.3 µm, ≥99.97% efficiency), Dual sterilization protocol (180°C dry-heat bake-out, 90°C moist-heat cycle) |
| Brand | Dynamica |
|---|---|
| Model | EHS-530 |
| Cabinet Class | Class II, Type A2 |
| Construction Material | 304 Stainless Steel Interior (One-Piece Seamless Welded) |
| External Dimensions (L×W×H) | 1950 × 750 × 2100 mm |
| Internal Work Area Dimensions (L×W×H) | 1862 × 574 × 628 mm |
| HEPA/ULPA Filtration Efficiency | ≥99.9995% @ 0.12 µm |
| Airflow System | Recirculating (70% re-circulated, 30% exhausted via dedicated duct or thimble connection) |
| Motor Type | Brushless DC ECM Motor with Variable Speed Control |
| Control Interface | DynaAir Color Touchscreen Controller with Real-Time Airflow Monitoring |
| Sensor | High-Sensitivity Thermal Anemometer for Inflow & Downflow Velocity Detection |
| Compliance | EN 12469:2000, NSF/ANSI 49-2022, ISO 14644-1 Class 5 (ISO Class 5 Equivalent), GLP-Ready Configuration |
| Brand | Dynamica |
|---|---|
| Model | HALO MPR-96 |
| Origin | Switzerland |
| Wavelength Range | 400–750 nm (MPR-96UV: 340–750 nm) |
| Absorbance Range | 0–4.0 OD |
| Resolution | 0.001 OD |
| Stability | ±0.001 OD (after 15 min warm-up) |
| Accuracy | ±1.0% ±0.01 OD (405 nm, 0.000–2.500 OD) |
| Repeatability | ±0.5% ±0.005 OD (405 nm, 0.000–2.500 OD) |
| Linearity | ±1.0% (405 nm, 0.000–2.500 OD) |
| Filter Positions | 5 (4 fixed + 1 user-selectable, 400–750 nm) |
| Read Time | ≤10 s (single wavelength, 96-well) |
| Plate Formats | 96-well flat, U-bottom, V-bottom |
| Optical Channels | 8 measurement + 1 reference |
| Detector | Silicon photodiode |
| Light Source | Tungsten-halogen lamp |
| Display | Backlit LCD, 320×240 px |
| Incubation (optional) | Ambient +4°C to +50°C, ±0.5°C accuracy |
| Dimensions (W×D×H) | 290×425×200 mm |
| Weight | 15 kg (net), 20 kg (gross) |
| Power | 110–220 V auto-switching, 50/60 Hz, 50 W (standby), 100 W (operational) |
| Brand | Dynamica |
|---|---|
| Model | NU-437-400S / NU-437-600S |
| Type | Class II A2 Biological Safety Cabinet |
| External Dimensions (W×D×H) | 1972 × 835 × 1600 mm (NU-437-600S) / 1362 × 835 × 1600 mm (NU-437-400S) |
| Internal Work Area (W×D×H) | 1788 × 597 × 724 mm (NU-437-600S) / 1178 × 597 × 724 mm (NU-437-400S) |
| Inflow Velocity | 0.53 m/s |
| Downflow Velocity | 0.30 m/s |
| HEPA Filtration Efficiency | ≥99.999% for particles 0.1–0.3 µm (H14 grade) |
| Airflow Configuration | 30% exhaust, 70% recirculation |
| Construction | 16-gauge 304 stainless steel, fully welded double-wall chamber |
| Pressure Integrity | Withstands 500 Pa static pressure test |
| Compliance | YY 0569–2011 (China), aligned with NSF/ANSI 49 and EN 12469 principles |
| Brand | Wyatt |
|---|---|
| Origin | USA |
| Manufacturer | Wyatt Technology Corporation |
| Type | Plate Reader III |
| Key | DLS & SLS Integration |
| Sample Throughput | 96-well and 384-well microplates |
| Detection Modes | Dynamic Light Scattering (DLS), Static Light Scattering (SLS), Temperature Ramp & Hold |
| Measurable Parameters | Hydrodynamic Radius (Rh), Radius of Gyration (Rg), Molecular Weight (Mw), Aggregation Onset Temperature (Tonset), Melting Temperature (Tm), Aggregation Temperature (Tagg), Diffusion Interaction Parameter (kD), Second Virial Coefficient (A2), B22, Turbidity, Viscosity (relative), Conformational Stability Index, Isothermal/Variable-Temperature Stability Profiles |
| Compliance | ASTM E2490, ISO 22412, USP <788>, FDA 21 CFR Part 11 Ready (with optional audit trail module) |
| Software Platform | Dynamics v8.x with GLP/GMP-compliant data handling |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | DZ-360A Ultra-Large Capacity Orbital Shaker |
| Pricing | USD 6,750 (FOB China) |
| Instrument Category | General-Purpose Orbital Shaker |
| Timing Range | Not equipped with digital timer |
| Oscillation Frequency | Not specified in technical documentation |
| Oscillation Amplitude | 30 mm |
| Temperature Control | Ambient-only operation (no integrated heating/cooling) |
| Platform Count | 3 independent orbital platforms |
| Total Capacity | 300 × 500 mL flasks or 96 × 500 mL Erlenmeyer flasks |
| External Dimensions | 1600 × 1400 × 1400 mm (W × D × H) |
| Power Consumption | 1000 W |
| Drive Mechanism | Balanced eccentric drive with reinforced steel frame |
| Operating Mode | Continuous orbital motion (20–25 rpm typical range for ultra-large loads, per industry-standard load calibration) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DZ-9001 |
| Price | USD 1,230 (FOB Jiangsu) |
| Speed Range | 50–250 rpm |
| Operating Temperature | Ambient (15–30 °C) |
| Platform Capacity | 60 × 250 mL Erlenmeyer flasks |
| Display | LED digital interface |
| Drive Mechanism | Brushless DC motor with eccentric drive |
| Orbit Diameter | 25 mm |
| Dimensions (W×D×H) | 720 × 720 × 850 mm |
| Net Weight | 85 kg |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | DZ-900A |
| Price | USD 2,480 (FOB Jiangsu) |
| Instrument Category | General-Purpose Orbital Shaker |
| Timer Range | Not equipped with mechanical/electronic timer (external timer or lab workflow control required) |
| Oscillation Frequency | 40–250 rpm |
| Orbital Diameter | 25 mm (standard for orbital shakers unless specified otherwise) |
| Temperature Control | Ambient-only operation (non-thermostatic) |
| Shelf Configuration | Two independently accessible stainless-steel shaking platforms |
| Capacity | 120 × 250 mL flasks or 96 × 500 mL flasks per layer |
| Dimensions (W×D×H) | 950 × 650 × 730 mm |
| Power Consumption | 100 W |
| Drive Mechanism | Brushless DC motor with microprocessor-controlled feedback loop |
| Operating Mode | Horizontal orbital motion (eccentric drive) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DZ2000 |
| Price | USD 2,650 (FOB) |
| Optical System | UCIS Infinity-Corrected, Parfocal, Positive-Image Path |
| Magnification Range | 40×–400× (expandable to 960× with optional 60× objective) |
| Eyepieces | Widefield PL10×/20 mm (high-eye-point, reticle-compatible) |
| Objectives | Infinity Long Working Distance (LWD) Plan Achromatic: 4×, 10×, 20×, 40× |
| Phase Contrast | 10×, 20×, 40× LWD |
| Condenser | N.A. 0.70, WD 72 mm / 120 mm, removable, with aperture diaphragm |
| Focusing | Coaxial coarse/fine focus |
| Stage | Mechanical XY stage, 80 × 50 mm travel |
| Illumination | 6 V / 30 W halogen lamp with aspheric collector lens |
| Fluorescence Module | Rotating filter turret for dual-band (B/G) or quad-band (UV/V/B/G) excitation |
| Camera Port | Trinocular port with 80:20 beam splitter ratio |
| Compliance | Designed per ISO 10934-1 (Microscopes — Nomenclature of components), IEC 61010-1 (Safety requirements for electrical equipment), and GLP-aligned documentation architecture |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | YDS-30 |
| Price | USD 420 (FOB) |
| Capacity | 30 L |
| Neck Diameter | 50 mm |
| Outer Diameter | 445 mm |
| Height | 660 mm |
| Empty Weight | 13 kg |
| Full Weight | 37.2 kg |
| Hold Time | 220 days |
| Cryogenic Insulation | High-Vacuum Multi-Layer Superinsulation (MLI) |
| Shell Material | Anodized Anti-Corrosion Aluminum Alloy |
| Protective Cover | Genuine Leatherette Outer Sleeve |
| Lid Type | Flip-Open with Locking Clamp |
| Customization | Available for neck diameter, internal rack configuration, and non-standard dimensions |
| Brand | Ebaiao |
|---|---|
| Origin | Hunan, China |
| Manufacturer | Yes |
| Instrument Type | Benchtop |
| Function Modules | Automatic Tube Cap Opening |
| Sample Throughput | ≥96 tubes per run |
| Sample Type | Whole Blood, Plasma, Buffy Coat, RBC |
| Pipetting Range | 1–1000 µL |
| Pipetting Speed | 1–3 seconds per transfer |
| Pipetting Accuracy | CV ≤5.0% at 2 µL (using 10-µL tips), CV ≤3.0% at 10 µL, CV ≤0.5% at >50 µL |