Life Science Instruments
Filter
Showing 2461–2490 of 2769 results
| Brand | Air Liquide China |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | VOYAGEUR2 |
| Pricing | Upon Request |
| Effective Volume | 1.75 L |
| Absorbed LN₂ Capacity | 1.35 L |
| Neck Opening Diameter | 30 mm |
| Empty Weight | 2.4 kg |
| Full Weight | 3.5 kg |
| External Diameter | 174 mm |
| Total Height | 395 mm |
| Daily Evaporation Rate | 0.1 L/day |
| Dynamic Holding Time | 8 days |
| Cryovial Capacity (0.25 mL) | 220 straws |
| Cryovial Capacity (0.5 mL) | 100 straws |
| 2 mL Vial Capacity (on rods) | 84 vials |
| 5 mL Vial Capacity (on rods) | 42 vials |
| Brand | Warner Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smart USSING |
| Instrument Type | Automated |
| Dimensions (W × D × H) | 380 mm × 75 mm × 20 mm |
| Temperature Control Range | 10 °C to 40 °C |
| Brand | Water Bear Technology |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FC200 |
| Pricing | Available Upon Request |
| Imaging Principle | Confocal Laser Fluorescence Microscopy |
| Slide Format | Standard 25 × 75 mm Glass Slides |
| Maximum Scan Speed | 10 lines/sec |
| Optical Resolution | ≤5 µm (lateral, diffraction-limited) |
| Detection Mode | Multi-channel Fluorescence Intensity Quantification |
| Sample Platform | Integrated Microfluidic Chip Holder for Single-Cell Western Blot (scWB) Arrays |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FH100DX |
| Flow Rate | 14–4000 mL/min |
| Speed Range | 4–400 RPM |
| Reversible | Yes |
| Flow Accuracy | ±0.25% (with calibrated flow system) |
| Speed Resolution | 0.1 RPM |
| Speed Regulation Accuracy | ±0.25% of full scale |
| Control Inputs | 0–20 mA, 4–20 mA, or 0–10 V analog |
| Control Outputs | 4–20 mA or 0–10 V analog |
| Motor | 1/10 HP (75 W), PMDC, phase-controlled |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −25–65 °C |
| Enclosure Material | ABS housing |
| pump head options | glass-filled nylon, Delrin®, stainless steel, cold-rolled steel, nitrile rubber, polycarbonate |
| IP Rating | IP31 |
| Certifications | ETL, cETL, CE, RoHS |
| Dimensions (L×W×H) | 31.7 × 27.9 × 15.2 cm (12.5 × 11 × 6 in) |
| Net Weight | 7 kg (15 lbs) |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | Wave Cellbag |
| Sterilization Method | Gamma Irradiation |
| Material Compliance | USP Class VI |
| Regulatory Documentation | FDA-registered DMF on file |
| Intended Use | Research, Process Development, cGMP Manufacturing, Cell Therapy Production |
| Bag Configuration | Single-use, pre-sterilized, disposable bioprocess bag |
| Brand | WD Precision |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WD-JL1000 |
| Price | USD 5,600 (FOB Beijing) |
| Core Technology | Granier-type Thermal Dissipation Probe (TDP) |
| Data Logger | Campbell Scientific CR1000x |
| Sensor Compatibility | TDP30 / TDP50 / TDP80 stem flow probes |
| Power Management | Adaptive low-power operation with AVRD voltage regulation |
| Environmental Rating | -40°C to +70°C (standard), -55°C to +85°C (extended) |
| Data Storage | Up to 400 days at 1-hour interval (128 MB internal + microSD up to 16 GB) |
| Communication | RS-232/RS-485, Ethernet 10/100 Mbps, USB-micro B, CS I/O, CPI/CDM |
| Input Capacity | 16 single-ended / 8 differential analog channels |
| Compliance | Designed for GLP-aligned field deployments |
| compatible with ASTM E2899-22 (Standard Guide for In Situ Sap Flow Measurement) and ISO 16634-1 | 2021 (Plant physiology — Sap flow measurement — Part 1: Thermal dissipation method) |
| Brand | Wener |
|---|---|
| Model | SparkShake |
| Type | Magnetic Microplate Shaker |
| Dimensions (L×W×H) | 146 × 103 × 42 mm |
| Weight | 2000 g |
| Speed Range | 100–2000 rpm |
| Amplitude | 2 mm |
| Positioning Accuracy | ±0.1 mm |
| Oscillation Modes | Orbital or Linear |
| Plate Compatibility | SBS-standard microplates (6-, 12-, 24-, 48-, 96-, 384-well plates and reservoirs) |
| Max Load | 500 g |
| Temp. Range | 5–80 °C |
| RH Limit | ≤85% non-condensing |
| Interface | RS232 |
| Control | Physical button panel |
| Origin | Shanghai, China |
| Manufacturer | Wener Nanotech |
| Brand | Top Cloud-agri |
|---|---|
| Model | TPM-BX-1 |
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Pricing | Upon Request |
| Brand | SOCOREX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Miniature Set |
| Instrument Type | Manual Mechanical Cell Disruptor |
| Sterilization | Autoclavable (121°C, 20 min) |
| Material | Low-Extractable Borosilicate Glass (WHEATON 33) |
| Package Includes | 7 Units (1× Tenbroeck, 1× G.P.I. 0.5 mL, 1× Dounce 1 mL, 1× 0.1 mL, 1× 0.2 mL, 1× Potter-Elvehjem 2 mL, 1× Conical 1 mL) |
| Compliance | USP <661.1>, ISO 8536-1 |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | BioMIX1 |
| Speed Range | 2–250 rpm |
| Stirring Capacity | 5–5000 mL |
| Power Consumption | 6 W |
| Operating Temperature | −10 to 50 °C (up to 80% RH) |
| Enclosure Material | Stainless Steel (IP64) |
| Dimensions (W×D×H) | 180×230×38 mm |
| Weight | 1.4 kg |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Control Unit | Integrated Display & Drive |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | DIGICEN 21/21R |
| Instrument Type | Benchtop Refrigerated Microplate Centrifuge |
| Max RCF | 26480 × g |
| Max Speed | 16500 rpm |
| Sample Capacity | 4 × 100 mL |
| Acceleration Time | ≥5 s |
| Operating Noise | ≤60 dB(A) |
| Temperature Range | −20 °C to +40 °C |
| Refrigerant | R449A |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, Directive 2011/65/EU, 2012/19/EU, 98/79/EC |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WH-05G |
| Heating Method | Air-Jacketed |
| Temperature Range (with Humidity) | +5°C above ambient to 65°C |
| Capacity | 50 L |
| Temperature Accuracy (at 37°C) | < ±0.3°C |
| Temperature Uniformity (at 37°C) | ±0.1°C |
| Chamber Material | Stainless Steel (AISI 304) |
| Control Interface | High-Resolution Touchscreen PID Controller |
| Power Supply | AC 220–240 V, 50/60 Hz |
| Heating Power | 340 W |
| Dimensions (Interior, W×D×H) | 345 × 368 × 375 mm |
| Dimensions (Exterior, W×D×H) | 440 × 480 × 610 mm |
| Net Weight | 35 kg |
| Safety Features | Independent Over-Temperature Protection, Audible/Visual Alarm, Auto-Heater Cut-Off, Door-Interlocked Fan & Heater Shutdown |
| Optional | RS232 Communication Port, Data Logging Software, Access Ports |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WH-40C |
| Temperature Range | +4 °C to 60 °C |
| Temperature Accuracy (ATC-calibrated) | < ±0.1 °C |
| Temperature Stability | ±1 °C at 37 °C |
| Chamber Volume | 400 L |
| Interior Dimensions (W×D×H) | 630 × 600 × 1100 mm |
| Exterior Dimensions (W×D×H) | 750 × 730 × 1550 mm |
| Net Weight | 160 kg |
| Heating Power | 450 W |
| Refrigeration Power | 400 W |
| Power Supply | AC 220–240 V, 50/60 Hz |
| Shelving | 2 standard / up to 5 stainless steel adjustable shelves |
| Control Interface | Membrane keypad with digital PID temperature regulation |
| Timer Functions | Programmable start/stop/alarm (1 min to 99 h 59 min) |
| Safety Features | Overtemperature cut-off, door-open alarm & auto fan/heater shutdown, audible alert, dual-seal insulated door with anti-fog double-glazed observation window |
| Optional Accessories | Data logging software, external port for sensor calibration or probe insertion, internal power socket, top-mounted LED illumination |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WS-350B |
| Display Type | Digital VFD |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Uniformity at 80°C | ±0.3°C |
| Temperature Accuracy at 80°C | ±0.7°C |
| Speed Range (with 96-well plate module) | 150–1500 rpm |
| Speed Range (with 1.5 mL tube module) | 150–1000 rpm |
| Speed Range (with 50 mL tube module) | 150–800 rpm |
| Orbit Diameter | 2 mm |
| Heating Power | 360 W |
| Dimensions (W×D×H) | 276 × 334 × 170 mm |
| Net Weight | 8.3 kg |
| Power Supply | 230 V, 50/60 Hz, 1.7 A |
| Operating Environment | 5–40°C, ≤80% RH |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WS198 |
| Temperature Range | Ambient +5 to 40 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Oscillation Frequency Range | 20–100 rpm |
| Oscillation Amplitude | 15 / 25 mm |
| Heating Power | 4 kW |
| Chamber Opening Dimensions | 82 × 66 × 50 cm (W×L×D) |
| External Dimensions | 106 × 75 × 75 cm (W×L×H) |
| Working Volume | 50–200 L |
| Compatible Sample Volumes | 25 mL–12 L cryobags |
| Display Resolution | 0.1 °C / 1 rpm |
| Safety Features | Over-temperature, over-current, and low-water-level protection |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WT4 |
| Temperature Range | -25 °C to 100 °C |
| Temperature Stability | ±0.05 °C |
| Dimensions (W×D×H) | 22 cm × 42 cm × 64 cm |
| Heating Power | 1.5 kW |
| Pump Flow Rate | 10 L/min |
| Maximum Pump Pressure | 0.23 bar |
| Bath Capacity | 4–6 L |
| Weight | 24 kg |
| Brand | -- |
|---|---|
| Origin | Canada |
| Manufacturer Type | General Distributor |
| Import Status | Imported |
| Model | WinCELL |
| Pricing | Upon Request |
| Brand | WIX |
|---|---|
| Origin | Shanghai, China |
| Model | WIX-autoPP Automated Western Blot Processing System |
| Throughput | Up to 24 membranes per run |
| Incubation Modules | 12 independently controlled modules |
| Temperature Control Range | 4–40 °C |
| Antibody Recovery Rate | ≥95% (up to 10 reuses) |
| Module Dimensions (optional) | 3×8 cm, 6×8 cm, or 9×8 cm |
| Membrane Wetting Maintenance | On-board wash buffer retention post-incubation |
| Fluidic Cross-Contamination Prevention | Automated in-line tubing rinse cycles |
| Compatibility | Open-platform design supports third-party primary/secondary antibodies and wash buffers |
| Brand | Workswell |
|---|---|
| Origin | Czech Republic |
| Model | WIC Infrared Thermal Imaging Camera for Animal Science |
| Resolution | 640 × 512 pixels |
| Thermal Sensitivity | 30 mK |
| Temperature Range | −25 °C to +150 °C (standard), optional up to +550 °C or +1500 °C with spectral filter |
| Accuracy | ±2 °C or ±2% of reading |
| Frame Rate | 9 Hz / 30 Hz |
| Spectral Band | 7.5–13.5 µm |
| Lens Options | 5°–69° FOV (9 mm–100 mm focal length) |
| Interface | USB 3.0 or GigE Vision compliant |
| IP Rating | IP65 |
| Software | WIRIS Suite with ROI analysis, multi-parameter environmental compensation, 14 color palettes, and time-synchronized imaging |
| Compliance | GenICam, USB3 Vision, IEEE 1588 Precision Time Protocol |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nanoliter2000 |
| Pricing | Upon Request |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model No. | 106667 |
| Electrode Type | Combined ISE with Integrated Reference System |
| Measuring Ion | Fluoride (F⁻) |
| pH Range | 5–7 |
| Membrane Material | Lanthanum Fluoride (LaF₃) Crystal |
| DIN Standard Compliance | DIN 38404-7, DIN EN ISO 10304-1 |
| Output Signal | mV vs. Ag/AgCl reference |
| Temperature Range | 0–50 °C |
| Response Time | <2 min (t₉₀) |
| Detection Limit | ≤1 µg/L (0.05 µM) F⁻ |
| Storage Solution | 0.001 mol/L NaF or 10 g/L NaF standard solution |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Type | Ion-Selective Electrode (ISE) |
| Series | 500 (Half-Cell) and 800 (All-in-One Composite) |
| Connector Options | BNC or DIN |
| Measurement Range | Ion-specific, spanning from sub-ppb to saturated concentrations (e.g., F⁻: 0.02 mg/L to saturation |
| NH₄⁺ | 0.02–900 mg/L |
| NO₃⁻ | 0.4–62,000 mg/L) |
| Compliance | Designed for ASTM D1293, ISO 10523, USP <781>, and EPA Method 9056A applications |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | pH/ION 7320 |
| Display | Graphical monochrome LCD |
| Input Channels | Dual-channel (pH/ORP + ISE) |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.005 |
| ORP Range | ±1200.0 mV, ±2500 mV |
| ORP Accuracy | ±0.3 mV, ±1 mV |
| Ion Concentration Units | mg/L, mol/L, mg/kg, ppm, % |
| ISE Calibration | 2–7 points, linear & non-linear methods |
| Temperature Range | −5.0 to +105.0 °C |
| Temp. Accuracy | ±0.1 °C |
| CMC (Continuous Measurement Control) | Yes |
| Memory | 200 manual / 5000 automatic readings |
| Interface | Micro-USB |
| Power | Alkaline batteries or universal AC adapter |
| Dimensions | 190 × 240 × 80 mm (H × L × W) |
| Weight | 0.8 kg (1.0 kg with optional printer) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | SensoLyt 700IQ |
| Measuring Principle | Potentiometric pH/ORP with Built-in FET Pre-amplifier |
| Output | Digital IQ Interface (2-wire, power + data) |
| pH Range | 0.00–14.00 (electrode-dependent) |
| ORP Range | −2000 to +2000 mV |
| Temperature Measurement | NTC, −5 °C to +60 °C, ±0.5 K accuracy |
| Response Time (t₉₉) | <15 s |
| Pressure Rating | Up to 10 bar |
| IP Rating | IP68 |
| Materials | PVC sensor head, 316Ti stainless steel body |
| Cable Length Options | Via SACIQ-7.0 (order separately) |
| Compliance | EN 61326 Class B, FCC Class A, CE, cETLus |
| Lightning Protection | Integrated surge suppression |
| Calibration Modes | CAL TEC AUTO (auto-standard), CAL CON 2P, CAL CON 1P |
| Calibration Validation | Slope −50 to −62 mV/pH, Zero Offset −45 to +45 mV |
| Electrode Compatibility | SensoLyt SEA, SEA-HP, DWA, ECA, PtA |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | TS 608/2-i |
| Air Circulation | Forced Convection |
| Control Method | Digital PID Temperature Control |
| Temperature Range | 10 °C to 40 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Fluctuation | ±0.5 °C |
| Capacity | 180 L |
| External Dimensions (H×W×D) | 850×600×600 mm |
| Refrigerant | R-600a |
| Operating Ambient Temperature | 10 °C to 32 °C |
| Storage Ambient Temperature | −10 °C to +50 °C |
| Power Consumption | 200 W |
| Net Weight | 34 kg |
| Brand | X-Imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | X-Imaging HedylaX |
| Inoculation Modes | Solid-to-Liquid, Solid-to-Solid, Liquid-to-Solid, Liquid-to-Liquid |
| Colony Picking Accuracy | ≥98% (for colonies ≥1 mm in diameter) |
| Positioning Precision | ±0.15 mm (XY stage), ±0.05 mm (Z-axis) |
| Brand | X-imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Smart Automated Cell Line Development System |
| Pricing | Available Upon Request |
| Brand | X-imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Smart Automated Drug Screening System |
| Pricing | Upon Request |
| Brand | X-imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Smart Mass Spectrometry Pre-analytical Automation System |
| Pricing | Available upon Request |
| Brand | X-imaging |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Smart Plasmid Construction and Extraction Automation System |
| Pricing | Available upon request |