| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | FDCS196 with Image Station |
| Microscope Type | Upright Biological Microscope |
| Eyepiece Configuration | Binocular |
| Temperature Range | −195 °C to +125 °C |
| Vacuum Range | down to 10⁻³ mbar |
| Temperature Stability & Accuracy | ±0.01 °C (with 100 Ω Pt sensor, ±0.1 °C absolute accuracy) |
| Heating/Cooling Rate | up to 150 °C/min |
| Optical Aperture Diameter | 1.3 mm |
| Sample X–Y Translation Range | 16 mm |
| Heating Stage Surface Area | 22 mm diameter |
| Minimum Objective/Condenser Working Distance | 4.5 mm / 12.5 mm |
| Cooling Method | Direct cryogen (e.g., liquid nitrogen) cooling of high-conductivity silver heating block |
| Illumination Path | C-mount-compatible transmitted-light optical train |
| Vacuum Monitoring | Pirani gauge integrated |
| Compliance | ISO 9001-certified service and training support |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | C140 |
| Price Range | USD 6,800–13,600 (FOB) |
| Temperature Range (lamp off) | −10 °C to +50 °C |
| Temperature Range (lamp on) | −5 °C to +55 °C |
| Temperature Stability | ±0.1 °C |
| Temp. Resolution | 0.1 °C |
| Heating Rate | +1.5 °C/min (IEC 60068-3-5) |
| Cooling Rate | −1.2 °C/min (IEC 60068-3-5) |
| Illumination Range (per shelf) | 5,000–30,000 lux |
| Photosynthetic Photon Flux (PPF) | 150–280 µmol/m²·s |
| Humidity Control Range | 10–98 %RH ±1 % |
| Humidity Source | Deionized or softened water (CaCO₃ ≤ 400 ppm), supply pressure 1–10 bar |
| Chamber Volume | 140 L |
| External Dimensions (W×D×H) | 615 × 475 × 669 mm |
| Internal Dimensions (W×D×H) | 519 × 475 × 669 mm |
| Door Configuration | Single left/right-swing door with auto-closing & thermal lock (>90 °C) |
| Sealing | Magnetic gasket |
| Shelving | Adjustable steel shelves with polymer coating |
| Lighting | Independently controllable fluorescent lamps per shelf |
| Ventilation | Dual internal fans for uniform temp./RH distribution |
| Controller | Microprocessor-based, 20-step programmable cycle, real-time monitoring of setpoint/actual values |
| Safety | Password-protected limit editing, audible/visual alarms, DIN 12880 Class 1 manual-reset overtemperature cutoff |
| Insulation | CFC-/HCFC-free polyurethane foam |
| Construction | Galvanized steel with white epoxy coating or AISI 304 stainless steel option |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FDM C140 |
| Price Range | USD 6,800–13,600 (FOB Italy) |
| Temperature Range (with Humidification) | 0 °C to +60 °C |
| Temperature Uniformity | ±0.5 °C |
| Relative Humidity Range | 10–98 % RH ±1 % RH |
| Chamber Capacity | 140 L |
| Temperature Resolution & Setpoint Increment | 0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating Rate | +1.5 °C/min (per IEC 60068-3-5) |
| Cooling Rate | −1.2 °C/min (per IEC 60068-3-5) |
| Noise Level | <55 dB(A) |
| Power Supply | 220–230 V AC, 50 Hz |
| Construction | AISI 304 stainless steel interior & white epoxy-coated galvanized steel exterior |
| Insulation | CFC/HCFC-free polyurethane foam (≥60 mm thickness) |
| Door | Dual-hinge, auto-closing, magnetic gasket seal, thermal lockout above 90 °C |
| Shelving | Adjustable, powder-coated steel racks (2 included, max 5) |
| Controller | Dual microprocessor system (separate PID loops for temperature and humidity), 20-step standard programmability, up to 50 stored programs (optional 200-step extended firmware) |
| Humidification | Low-inertia steam generator, compatible with deionized water or softened water (CaCO₃ ≤400 ppm), supply pressure 1–10 bar |
| Safety | Manual-reset Class 1 overtemperature protection (DIN 12990), password-protected parameter limits, visual/audible alarm on deviation |
| Brand | Femtonics |
|---|---|
| Origin | Hungary |
| Model | Smart |
| Microscope Type | Multiphoton (Two-Photon & Three-Photon) Microscope |
| Configuration | Upright, Motorized XYZ-Adjustable Frame |
| Scan Modes | Galvo, Resonant, or Hybrid Scanning |
| Wavelength Range | Visible to Near-Infrared (NIR) |
| Compatibility | In Vivo, Acute Slice, Cell Culture, VR Integration |
| Optional Modules | Multi-Beam Path, FLIM Extension, Epi-Fluorescence Unit, Ex Vivo Chamber, Green LED Vascular Illumination, Bridge Mount, Piezo Objective Positioner, Motorized Tilt Objective Unit |
| Compliance | Designed for GLP/GMP-aligned neuroscience labs |
| Brand | Femtonics |
|---|---|
| Origin | Hungary |
| Model | Atlas |
| Objective Lenses | 16× water immersion, 25× water immersion, 25× multi-immersion |
| Spatial Resolution | X: 450 nm, Y: 450 nm, Z: 2300 nm |
| Scan Speed | 100 kHz point access, 40 fps @ 510×510 px (500×500 µm²), up to 3000 fps in ROI mode |
| Compliance | CE-marked, ISO 13485–aligned design, compatible with GLP/GMP audit trails via optional software modules |
| Brand | Tailin Biotech |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Origin Category | Domestic (China) |
| Model | Ferret Isolator |
| Pricing | Available Upon Request |
| Brand | Festo |
|---|---|
| Origin | Germany |
| Model | EHAA-G1-E20-40-GGA1-AP |
| Mounting Orientation | Vertical |
| Corrosion Resistance Class | CRC2 (Medium) |
| PWIS Compliance | VDMA 24364, Category III |
| Storage Temperature | −20 °C to +70 °C |
| Operating Ambient Temperature | 0 °C to +40 °C |
| Relative Humidity | 0–100% (non-condensing) |
| Weight | 95 g |
| Screw Material | High-alloy stainless steel |
| Bracket Material | High-alloy stainless steel |
| Positioning Element Material | High-alloy steel |
| Brand | Festo |
|---|---|
| Origin | Germany |
| Model | VABS-K3-16S-20-N18-P |
| Nominal Diameter | 2 mm |
| Valve Body Size | 16 mm |
| Fluid Connection | Internal Thread, 1/8 NPT |
| Mounting Orientation | Adjustable |
| Max. Number of Valve Positions | 1 |
| Flow Direction | Bidirectional |
| Operating Media | Liquids and Gases |
| Material Compatibility | PEEK (Polyetheretherketone) |
| Corrosion Resistance Class | CRC0 (No corrosion resistance) |
| PWIS Compliance | VDMA 24364, Category III |
| Storage Temperature | –20 °C to +70 °C |
| Medium Temperature Range | 0 °C to +50 °C |
| Ambient Temperature Range | 0 °C to +50 °C |
| Tightening Torque (Valve Mounting) | 0.3 Nm |
| Tightening Torque (Base Installation) | 7 Nm |
| Max. Recommended Torque (Threaded Interface) | 0.6 Nm |
| Weight | 26 g |
| Food Industry Suitability | Confirmed per supplementary documentation |
| Brand | Festo |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VTOE-D9-T3-M22C-08-F-P-P-S |
| Nominal Orifice Diameter | 0.8 mm |
| Dispensing Needle ID | 1 mm |
| Needle Length | 30 mm |
| Grid Pitch | 9 mm |
| Valve Function | 2/2-way, normally closed, monostable |
| Operating Pressure Range | 0–0.05 MPa (0–7.25 psi) |
| Internal Volume (incl. fluid interface) | 113 µL |
| Minimum Dispense Volume | 5 µL |
| Typical Volume Accuracy | <1% CV for volumes >5 µL |
| Max. Switching Frequency | 4 Hz |
| Opening Time | 7 ms |
| Closing Time | 2 ms |
| Continuous Duty Cycle | 100% (standalone), 50% (modular installation, max. on-time 1 s) |
| Electrical Power Consumption | 1.8 W |
| Nominal Voltage | DC 24 V ±10% |
| Ambient Temperature (operating) | 5–40 °C |
| Medium Temperature | 5–50 °C |
| Storage Temperature | −20–70 °C |
| Protection Class | IP30 |
| Weight | 18 g |
| Electrical Interface | 2-pin open cable, 150 mm length, AWG28, stripped ends |
| Fluid Interface | UNF 1/4-28 |
| Needle Material | High-alloy stainless steel (1.4301) |
| Corrosion Resistance Class | CRC0 |
| Shock & Vibration | EN 60068-2-27 / EN 60068-2-6, Severity Level 2 |
| Max. Altitude | ≤2000 m NHN |
| Pollution Degree | 2 |
| Relative Humidity | 0–95% non-condensing |
| Brand | Festo |
|---|---|
| Origin | Germany |
| Model | VYKA-F7-M32-12-PF-5YQ7 |
| Type | 3/2-way, normally open/closed, direct-acting pilot valve with spring return |
| Nominal bore | 1.2 mm |
| Operating voltage | DC 12–26 V (±10% tolerance) |
| Power consumption | 3.5 W (high-current phase), 0.3 W (low-current hold phase) |
| Switching time (open/close) | 9 ms (gas medium, 20 °C, 1 bar Δp) |
| Operating temperature (fluid) | 15–50 °C |
| Ambient temperature | 15–50 °C |
| Storage temperature | −20–70 °C |
| Pressure range | −0.05 to 0.2 MPa (−0.5 to 2 bar) depending on function |
| Differential pressure max | 0.2 MPa |
| Burst pressure | 2.3 MPa |
| Rated flow (DIN 1343, air, Δp = 1 bar) | 11 L/min |
| Kv value | 0.021 m³/h (water, Δp = 1 bar) |
| Housing material | Reinforced PEEK/PPA |
| Diaphragm & seal material | FFPM |
| Weight | 10.9 g |
| Protection class | IP40 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FFX-TG |
| Price Range | USD 13,500 – 40,500 (FOB Hamburg) |
| Separation Method | Fully Automated |
| Leukocyte (Nucleated Cell) Recovery Rate | ≥95% |
| Cell Viability | ≥90% |
| Sample Throughput | Up to 4 independent tissue samples per run |
| Tissue Input Mass | 10–300 mg |
| Processing Time | 2–3 minutes per sample |
| Rotor-Stator Gap | 100 µm |
| Brand | FiberCell Systems |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | P3202 |
| Housing Material | Polysulfone |
| Configuration | Duet Pump + Cartridge-Based Closed Perfusion System |
| Brand | FIDA |
|---|---|
| Origin | Denmark |
| Model | NEO |
| Sample Capacity | 2 × 96-well plates or 2 × 50 vials |
| Temperature Control Range | 15–55 °C |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FOP-LS-PT9-11 / FOP-LS-PT9-10 |
| Pricing | Upon Request |
| Brand | Fitlylab |
|---|---|
| Origin | Guangdong, China |
| Model | W1 |
| Material | Fully Stainless Steel (316L-grade components) |
| Filter Cup Diameter | φ47 mm or φ50 mm |
| Membrane Pore Size | 0.22 µm or 0.45 µm |
| Configuration | Triple-station with independent valve control per station |
| Sterilization Compatibility | Autoclavable (121 °C, 20 min, steam) |
| Compliance | Designed for ISO 7218, ASTM D5673, and USP <61> microbiological testing workflows |
| Includes | Stainless steel filtration cups, stainless steel support screens, stainless steel manifold支架, stainless steel isolation valves, anodized aluminum clamps, silicone tubing, overflow-prevention collection flask, vacuum pump interface |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-1000L |
| Flow Rate | 0–10 mL/min |
| Max Pressure | 2 MPa (20 bar) |
| UV Detection | 280 nm (LED source, ±3 nm accuracy, 2 mm path length) |
| Conductivity Range | 0–500 mS/cm |
| Auto-injector Valve | 3-position, 7-port valve with quantitative loop |
| Fraction Collector | X-Y matrix type, 48-position standard rack for 18×150 mm tubes or 15 mL centrifuge tubes |
| Software | Fully automated workstation with method library, peak-triggered collection, audit trail, user management, and instrument self-diagnosis |
| Optional Modules | pH detector (with temperature compensation), high-pressure upgrade kit (up to 5 MPa), chromatography refrigerator |
| Brand | Flash Spectrum (Shanghai Flash Spectrum) |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-2000M |
| Flow Rate | 0–25 mL/min (upgradable to 50 mL/min) |
| Max Pressure | 5 MPa (50 bar / 725 psi) |
| UV Wavelength Range | 190–850 nm |
| UV Accuracy | ±1 nm |
| UV Repeatability | ±0.2 nm |
| Path Length | 2 mm |
| Conductivity Range | 0–999.9 mS/cm |
| Autoinjector Valve | 3-position, 7-port solenoid valve with quantitative loop capability |
| Fraction Collector | X-Y matrix type, 48-position, standard 18 mm × 150 mm tube rack |
| Gradient Formation | Linear and multi-step gradient, high-precision dual-pump mixing |
| Solvent Compatibility | Aqueous buffers for biomolecule purification |
| Viscosity Limit | ≤5 cP |
| Optional Modules | pH detector (with temperature compensation), high-pressure upgrade kit (to 15 MPa), chromatography cold cabinet |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Biotech Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-2000Prime |
| Flow Rate Range | 0.01–50 mL/min |
| Pressure Range | 0–1 MPa (145 psi) |
| UV Wavelength Range | 190–850 nm |
| Path Length | 2 mm |
| Conductivity Range | 1 µS/cm – 999.9 mS/cm |
| pH Range | 0–14 |
| pH Accuracy | ±0.01 pH unit with temperature compensation |
| Fraction Capacity | 120 tubes (15–18 mm diameter) |
| Solvent Compatibility | Aqueous biological buffers up to 10 cP viscosity |
| Gradient Formation | Programmable dual-pump high-precision mixing |
| Detection Modes | UV absorbance, conductivity, pH (optional), real-time peak tracking |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3000Go1 |
| Flow Rate | 0.01–50 mL/min (optional 0.01–100 mL/min) |
| Max Pressure | 27 MPa (270 bar) at ≤25 mL/min |
| UV Detection | 280 nm (±3 nm accuracy, 2 mm pathlength) |
| Conductivity Range | 0–999.9 mS/cm |
| Gradient Formation | High-precision dual-pump gradient system |
| Sample Injection | Automated 3-position, 7-port valve with quantitative loop |
| Fraction Collection | X-Y matrix collector (standard 96-position, 18×150 mm tube compatibility) |
| Software | ClearFirst-3000 Series Workstation (PC-based, method library, user management, audit trail-ready architecture) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3000Go2 |
| Flow Rate Range | 0.01–50 mL/min (optional up to 100 mL/min) |
| Max Pressure | 27 MPa (270 bar) at ≤25 mL/min |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| UV Detection | Quad-wavelength simultaneous detection |
| Conductivity Range | 0–999.9 mS/cm |
| pH Detector (optional) | with temperature compensation |
| Column Switching | Up to 5-column + 1 bypass position |
| Fraction Collector | X-Y matrix configuration, 96-position standard (18×150 mm tubes), programmable by peak, volume, or manual trigger |
| System Compatibility | Aqueous buffers, viscosity ≤5 cP |
| Software | ClearFirst-3000 Series Workstation (PC-based, method library, user management, audit trail, system self-test) |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3000Max |
| Flow Rate Range | 0.01–50 mL/min (optional 0.01–100 mL/min) |
| Max Pressure | 27 MPa (270 bar) at ≤25 mL/min |
| UV Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Conductivity Range | 0–999.9 mS/cm |
| Column Positions | Up to 5 |
| Buffer Inlets | 16 total (8 per pump) |
| Sample Inlets | 8 |
| Pathlength Options | 2 mm (standard), 5 mm & 10 mm (optional) |
| Fraction Collector Capacity | 96-position 18×150 mm tube rack (standard), 11-position large-volume collection |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3000Plus |
| Flow Rate Range | 0.01–50 mL/min (optional 0.01–100 mL/min) |
| Max Pressure | 27 MPa (270 bar) at ≤25 mL/min |
| UV Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Conductivity Range | 0–999.9 mS/cm |
| Column Positions | Up to 5 |
| Detection Channels | Quad-wavelength UV-Vis + Conductivity + Optional pH/Pressure |
| Gradient Formation | High-precision dual-pump gradient mixing |
| Fraction Collection | X-Y matrix collector with 96-position 18 mm tube rack (standard), 11-position large-volume collection |
| Compliance | Designed for GLP-compliant workflows, supports audit trail-ready method storage and user management |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Biotech Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3000Pro |
| Pump Flow Range | 0.01–50 mL/min (optional 0.01–100 mL/min) |
| Max Pressure | 27 MPa (270 bar) at ≤25 mL/min |
| UV Detection Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical Path Lengths | 2 mm (standard), 5 mm & 10 mm (optional) |
| Conductivity Range | 0–999.9 mS/cm |
| Conductivity Detector | High-precision, dual-electrode design |
| pH Detector (optional) | Temperature-compensated, accuracy优于进口同类产品 |
| Gradient Formation | Precision high-pressure binary gradient mixing |
| Detection Channels | Quad-wavelength simultaneous detection |
| Column Compatibility | Single-column configuration (1-position), optional 6-port column switching valve (5 columns + bypass) |
| Fraction Collector | X-Y matrix format, 96-position rack support (18 × 150 mm tubes or 15 mL conical tubes), programmable peak-, volume-, or manual-triggered collection |
| System Fluidics | Bio-inert PEEK and titanium components, pressure-rated to 27 MPa |
| Software | ClearFirst-3000 Series Workstation (Windows-based, GLP-compliant audit trail, user management, method library, instrument self-diagnosis) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3000Pro |
| Flow Rate Range | 0.01–50 mL/min (optional 0.01–100 mL/min) |
| Max Pressure | 27 MPa (270 bar) at ≤25 mL/min |
| UV Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Conductivity Range | 0–999.9 mS/cm |
| Path Length Options | 2 mm (standard), 5 mm & 10 mm (optional) |
| Gradient Formation | High-precision dual-pump gradient mixing |
| Detection Channels | Quad-wavelength simultaneous UV-Vis detection |
| Column Compatibility | Single-column configuration (expandable via optional multi-column switching valve) |
| Fraction Collection | X-Y matrix collector with 96-position 18×150 mm tube rack (standard), configurable for multiple tube formats |
| Software | ClearFirst-3000 Series Workstation (Windows-based, GLP-compliant audit trail, method database, user management, instrument self-test) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3200 |
| Flow Rate Range | 0.01–300 mL/min (optional up to 400 mL/min) |
| Max Pressure | 20 MPa (200 bar) at ≤50 mL/min |
| UV Wavelength Range | 190–850 nm |
| UV Wavelength Accuracy | ±1 nm |
| UV Wavelength Repeatability | ±0.2 nm |
| Optical Path Lengths | 2 mm (standard), 5 mm & 10 mm (optional) |
| Conductivity Range | 0–999.9 mS/cm |
| Conductivity Accuracy | ≤±0.01 mS/cm |
| Buffer Inlets | 4 (dual-pump configuration) |
| Fraction Collector | X-Y matrix, 96-position, compatible with 18×150 mm tubes and 15 mL centrifuge tubes |
| Column Capacity | 1 column (expandable via optional column selector valve) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-3500 |
| Flow Rate Range | 0.01–300 mL/min (optional up to 400 mL/min) |
| Pressure Range | 0–20 MPa (0–200 bar) at ≤50 mL/min |
| UV Wavelength Range | 190–850 nm |
| Detection Channels | Quad-wavelength simultaneous detection |
| Conductivity Range | 0–999.9 mS/cm |
| Conductivity Accuracy | ≤±0.01 mS/cm |
| Column Positions | 5 |
| Buffer Inlets | 4 (2 per pump) |
| Sample Inlets | 8 |
| Fraction Collection | X-Y matrix collector with 12 outlets (11 large-volume + waste), 18 mm tube rack (96-position), temperature-controlled |
| Gradient Formation | High-precision dual-pump gradient generation |
| System Compatibility | Aqueous biological buffers only |
| Software | ClearFirst-3500 Dedicated Workstation (Windows-based, GLP-compliant audit trail, method database, user management, instrument self-test) |
| Brand | Flash Spectrum (Shanghai Flash Spectrum Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-4000 |
| Flow Rate | 0–500 mL/min (optional 0–1000 mL/min) |
| Pressure Range | 0.01–10 MPa (0.1–250 mL/min) |
| UV Detection | Four-wavelength simultaneous detection (190–850 nm), wavelength accuracy ±1 nm, repeatability ±0.2 nm, pathlength 2 mm |
| Conductivity Range | 0–999.9 mS/cm |
| Collection Valve | 7-port high-volume fraction collector |
| Sample Inlet | 8-channel sample selection valve |
| Buffer Selection | 4-channel buffer expansion module |
| pH Detector (optional) | with temperature compensation |
| System Compatibility | Aqueous biological buffers up to 5 cP viscosity |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-4500 |
| Flow Rate (System Pumps) | 0–1200 mL/min |
| Flow Rate (Sample Pump) | 0–600 mL/min |
| Pressure Range | 0.01–2 MPa (20 bar) at ≤600 mL/min |
| UV Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical Path Length | 2 mm |
| Conductivity Range | 0–999.9 mS/cm |
| Detection Channels | Quad-wavelength UV-Vis + Conductivity + Optional pH/Pressure |
| Collection Ports | 12-position fraction valve |
| Compliance | Designed for GLP-compliant protein purification workflows under ISO 22367 and USP <1058> analytical instrument qualification guidelines |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ClearFirst-500L |
| Pricing | Available Upon Request |
| Flow Rate Range | 0–40 mL/min |
| Maximum System Pressure | 0.2 MPa (2 bar / 30 psi) |
| UV Detection Wavelength | 280 nm (LED-based) |
| Wavelength Accuracy | ±3 nm |
| Optical Path Length | 2 mm |
| Conductivity Range | 0–500 mS/cm |
| Fraction Collector Configurations | 48-position (18 mm × 150 mm tubes), 130-position (1.5 mL tubes), 88-position (13 mm × 100 mm tubes), 80-position (15 mm × 150 mm tubes), 20-position (50 mL tubes) |
| Solvent Compatibility | Aqueous Buffers Commonly Used in Biomolecular Purification |
| Detection Systems | UV (280 nm), Conductivity, Optional pH (with temperature compensation) |
| Control Interface | Android-based Touchscreen Console + Optional PC Software (ClearFirst PC Edition) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ClearFirst-500M |
| Flow Rate | 0–40 mL/min |
| Max Pressure | 0.2 MPa (2 bar / 30 psi) |
| UV Wavelength | 280 nm ±3 nm |
| Path Length | 2 mm |
| Conductivity Range | 0–500 mS/cm |
| Fraction Collector | X-Y robotic matrix collector |
| Detector Type | LED-based single-wavelength UV detector |
| Control Interface | Android-based touchscreen workstation |
| System Compatibility | Aqueous biobuffer-compatible fluidic path |
| Compliance | Designed for GLP-compliant workflows |