Liquid Chromatography Mass Spectrometry
Filter
Showing 31–60 of 189 results
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Agilent InfinityLab LC/MSD iQ |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Scope | General-Purpose LC/MS Analysis |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC/MSD |
| Instrument Type | Single Quadrupole |
| Application Scope | General-Purpose |
| Mass Range | m/z 10–2000 |
| Scan Speed | 10,400 Da/s |
| Minimum SIM Dwell Time | 5 ms |
| Polarity Switching Time | < 300 ms |
| Ion Sources | ESI, APCI, Multi-Mode (ESI + APCI) |
| Dimensions (W × D × H) | 44.3 cm × 63.5 cm × 47.0 cm |
| Compatible Software | OpenLab CDS, OpenLab ChemStation, MassHunter WalkUp, MassWorks Software |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC/MSD XT |
| Instrument Type | Single Quadrupole |
| Sensitivity | Sub-pg on-column detection limit (e.g., 500 fg injected for caffeine in ESI positive mode) |
| Ionization Sources | Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), Atmospheric Pressure Photoionization (APPI), Agilent Jet Stream (AJS) ESI/APCI, Dual-Mode Source |
| Mass Range | m/z 10–3000 |
| Scan Speed | Up to 10,000 Da/sec |
| Polarity Switching | < 200 ms |
| Software Platform | OpenLAB CDS (Chemical Workstation), compliant with FDA 21 CFR Part 11 and EU Annex 11 |
| Calibration Technology | MassWorks™ high-accuracy mass calibration (Cerno Bioscience integration) |
| Form Factor | Stackable module compatible with Agilent 1260/1290 Infinity II LC systems |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | InfinityLab Pro iQ / Pro iQ Plus |
| Instrument Type | Single-Quadrupole Mass Spectrometer |
| Application Scope | General-Purpose LC/MS Detection |
| Mass Range | m/z 2–1600 (Pro iQ) |
| Sensitivity | < 100 fg on-column (Pro iQ, ESI positive mode, reserpine) |
| Ion Sources | ESI, APCI, Dual ESI/APCI (MMI), AJS (Pro iQ Plus only) |
| Vacuum System | Agilent MS45 rotary vane pump |
| SIM Minimum Dwell Time | 1 ms |
| Polarity Switching Speed | < 15 ms |
| Dynamic Range | Up to 6 orders of magnitude (linear) |
| Dimensions (W × D × H) | 39.6 cm × 54.8 cm × 35.0 cm |
| Software Platform | OpenLab CDS (v2.8 FP2 and later), MassHunter WalkUp, MassWorks Oligonucleotide Analyzer, Deconvolution Accelerator for OpenLab CDS |
| Key Technologies | Cyclone Ion Guide, Hyperbolic Quadrupole Mass Analyzer, VacShield Vacuum Shield, SWARM Auto-Tuning, InfinityLab Assist Interactive Touch Interface |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Revident LC/Q-TOF |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Application Field | General-Purpose Small-Molecule Analysis |
| Mass Range | m/z 20–10,000 |
| Sensitivity | <40 fg on-column reserpine (positive mode), <40 ppt (S/N ≥ 1000:1 for 1 pg on-column) |
| <40 fg on-column chloramphenicol (negative mode), <40 ppt (S/N ≥ 750 | 1 for 1 pg on-column) |
| Resolution | TOF mass resolution (FWHM) >60,000 at m/z 2722, acquisition-rate independent |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LCMS-Ultivo |
| Instrument Type | Triple Quadrupole |
| Application Field | General-Purpose |
| Mass Range | 10–2,000 m/z |
| Sensitivity | <5 fg on-column injected caffeine (S/N ≥ 100:1 for MRM) |
| Resolution | Unit mass resolution (0.7 Da full width at half maximum) |
| Accurate Mass Capability | Not applicable (triple quadrupole, not high-resolution) |
| Operating Pressure Range | Ion source: atmospheric pressure |
| Collision cell | ~2–3 mTorr |
| Analyzers & detector | <1 × 10⁻⁶ Torr |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Ultivo |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Sensitivity | IDL < 12.5 fg |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | UHPLC TQMS G1 / LC-MS/MS |
| Mass Range | 2–1500 amu (standard), 2–2000 amu (G1s variant) |
| Resolution | 0.4 / 0.7 / 1.5 FWHM (full width at half maximum) |
| Application Scope | General-purpose quantitative and qualitative analysis |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | UHPLC TQMS G1 |
| Price | Upon Request |
| Application Scope | General-purpose |
| Mass Range | 2–1500 amu (G1) / 2–2000 amu (G1s) |
| Resolution | 0.4 / 0.7 / 1.5 FWHM |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PQ LC–PlasmaQuant MS |
| Instrument Type | Triple Quadrupole ICP-MS Coupled with Liquid Chromatography |
| Application Scope | Universal Elemental Speciation |
| Interface Configuration | Integrated LC–ICP-MS Coupling Kit |
| Software Platform | Clarity Chromatography Software (DataApex) + ASpect MS |
| Regulatory Compliance | FDA 21 CFR Part 11–Ready, GLP/GMP-Compatible Data Handling |
| Automation Level | Fully Automated Unattended Operation Support |
| Column Compatibility | Reversed-Phase HPLC, Ion Chromatography (IC), Size-Exclusion Chromatography (SEC) |
| Detection Capability | Sub-ng/kg LODs for As/Cr species |
| Dynamic Range | 11 orders of magnitude (ADD11 digital detector) |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | LC Cassitrap 120K |
| Pricing | Upon Request |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | SQ910 LC-MS |
| Pricing | Available Upon Request |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TQ9100 |
| Instrument Type | Triple Quadrupole Mass Spectrometer (QqQ) |
| Application Scope | General-Purpose LC-MS/MS |
| Resolution | Unit Resolution (m/Δm ≈ 1,000 FWHM at m/z 500) |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Domestic Product Classification | China-Made Instrument |
| Model | TQ9120 LC-MS/MS |
| Pricing | Available Upon Request |
| Brand | ASPEC |
|---|---|
| Origin | USA |
| Manufacturer | IonSense, Inc. |
| Model | ASAP |
| Instrument Type | Atmospheric Pressure Ionization Source |
| Mass Range | 5–3000 amu |
| Sensitivity | pg-level (dependent on coupled mass spectrometer) |
| Resolution | Determined by host MS platform |
| Accurate Mass Capability | Enabled via compatible high-resolution MS (e.g., Orbitrap, FT-ICR, QTOF) |
| Brand | ASPEC (Prosolia) |
|---|---|
| Origin | USA |
| Model | Flowprobe |
| Instrument Type | Ambient Ion Source |
| Compatible MS Platforms | Thermo Orbitrap, Bruker timsTOF, SCIEX TripleTOF & QTRAP |
| Sample Interface | Liquid Microjet Surface Sampling Probe (LMJ-SSP) |
| Spatial Resolution | ~630 µm (rapid profiling), down to ~50 µm (high-res DESI-2D integration) |
| Operating Mode | Real-time, continuous-flow in situ microextraction coupled with ESI ionization |
| Optical Guidance | Integrated coaxial camera for real-time probe positioning and surface navigation |
| Application Scope | Label-free molecular imaging of tissues, single-cell metabolomics, spatially resolved lipidomics/peptidomics, forensic toxicology, dried blood spot (DBS) analysis, time-resolved pharmacokinetics |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Automs TQ6000 |
| Price Range | USD 300,000–320,000 (FOB) |
| Instrument Type | Triple Quadrupole (QqQ) |
| Application Scope | General-Purpose LC-MS/MS |
| Maximum System Pressure | >12,000 psi |
| Ionization Modes | Dual ESI/APCI with Tool-Free Switching |
| Software Interface | Fully Localized Chinese GUI with Intelligent Quantitation & Method Development Engine |
| Regulatory Compliance | Designed to support GLP/GMP workflows, audit trail-enabled data handling, and 21 CFR Part 11–compliant user access control (optional configuration) |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Triple Quadrupole (QqQ) |
| Application Field | General-Purpose |
| Mass Range | 10–2250 Da |
| Ionization Sources | Dual ESI/APCI |
| Collision Cell | Curved RF-only Quadrupole Design |
| Gas System | Counter-Flow Curtain Gas Configuration |
| Software | Integrated Intelligent Tuning, Calibration, Method Optimization & Reporting Engine |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | HMS7680 |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Application Scope | General-Purpose |
| Ionization Sources | ESI and APCI |
| IM Resolution Modes | 3 Adjustable Settings |
| Mass Analyzer Configuration | Quadrupole + Orthogonal TOF |
| Collision Cell | Axial DC Voltage Gradient CID with Tunable Collision Gas |
| Temperature Control | Water-Cooled, Thermally Stabilized Flight Tube with Intelligent Compensation |
| Acquisition Mode | 4D Full-Spectrum Simultaneous Detection |
| Software Features | Automated Tuning, Real-Time Mass Calibration, Method Optimization, and Integrated Data Processing & Reporting |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | compact |
| Instrument Type | Quadrupole-Time-of-Flight (QTOF) |
| Application Scope | Universal LC-MS/MS Platform |
| Key Specifications | 50 GBit/sec acquisition rate |
| Resolution | Ultra-High Resolution TOF (UHR-TOF) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Time-of-Flight (TOF) |
| Configuration | Dual-Source GC-MS (EI + CI) |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) with Helical Resonant Plasma (HRP) source |
| Resolution | >40,000 FWHM (m/z 200) |
| Mass Accuracy | <1 ppm RMS (calibrated) |
| Scan Rate | Up to 50 spectra/sec (full-spectrum, high-res) |
| CI Reagent Gases | N₂H⁺, H₃O⁺, H(H₂O)ₙ⁺, NH₄⁺ (software-switchable, no hardware intervention) |
| Compliance | Fully compatible with GLP/GMP workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Tandem Quadrupole (Triple Quad) |
| Configuration | LC-MS/MS |
| Application Scope | Universal Quantitative Analysis |
| Regulatory Compliance | Designed for GLP/GMP environments, compatible with 21 CFR Part 11 audit trail requirements |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Tandem Quadrupole (Triple Quad) |
| Model | EVOQ® DART-TQ+ |
| Application Scope | General-purpose small-molecule screening and quantitation |
| Ionization Modes | Fully integrated DART (Direct Analysis in Real Time), swappable with VIP-HESI (Heated Electrospray Ionization) and APCI sources |
| MRM Transition Rate | Up to 1,000 transitions/sec |
| Scan Speed | Up to 30,000 Da/sec |
| Detector | EDR™ Electron Multiplier with real-time gain optimization |
| Software Platform | tqControl™ with MRM Builder, automated tuning, daily performance verification, and rule-based data review |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Quadrupole-TOF |
| Application Scope | Universal LC-MS/MS |
| Optional Features | ETD, HighMass Mode |
| Resolution (FSR) | >80,000 at full sensitivity |
| Mass Accuracy | <1 ppm RMS (calibrated, typical) |
| Mass Range | Up to 20,000 m/z (HighMass mode) |
| Isotopic Pattern Fidelity | True Isotopic Pattern (TIP) enabled |
| Software Platform | Compass DataAnalysis, Compass AutoPrep, SmartFormula™, SmartFormula 3D™ |
| Regulatory Compliance | FDA 21 CFR Part 11 compliant workflows available |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | FTMS (Fourier Transform Mass Spectrometry) |
| Model | scimaX™ |
| Resolution | R > 20,000,000 (at m/z 400) |
| Cooling System | Helium-gas-cooled Maxwell™ superconducting magnet (cryogen-free) |
| Ion Sources | Dual ESI/MALDI with automated switching |
| Fragmentation Modes | ECD, EID, ETD, CID, EDD, SORI-CID, MALDI-ISD, NETD |
| Acquisition Mode | CASI (Collision-Activated Selective Ion accumulation) |
| Application Scope | Universal — petroleumomics, phenomics, metabolomics, native proteomics, label-free MSI, fragment-based drug discovery |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | solariX |
| Instrument Type | FTMS (Fourier Transform Mass Spectrometer) |
| Magnetic Field Strength Options | 7T, 12T, 15T |
| Ionization Modes | ESI and MALDI (dual-source configurable) |
| Detection Technology | ParaCell detector with AMP (Absorption Mode Processing) |
| Software Platform | Bruker Compass suite including SmartFormula |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Model | timsMetabo™ |
| Application Scope | Universal (Metabolomics, Lipidomics, Untargeted Small-Molecule Analysis) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS)–based Mass Spectrometer |
| Model | timsOmni |
| Application Scope | Universal for native and denatured proteoforms, intact proteins, oligonucleotides, PTMs, small molecules, and multi-specific biologics |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | timsTOF fleX™ |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Scope | Universal Platform for Spatial Omics and Molecular Imaging |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Model | timsTOF fleX with MALDI-2 |
| Application Scope | Universal (Biological Tissue Imaging, Lipidomics, Metabolomics, Drug Distribution Studies) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Software Platform | SCiLS Lab, DataAnalysis, and TIMS Control integrated in Compass 6.0 suite |
| Ionization Modes | MALDI and MALDI-2 (laser post-ionization), ESI (via LC coupling) |