Liquid Chromatography Mass Spectrometry
Filter
Showing 61–90 of 256 results
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | compact |
| Instrument Type | Quadrupole-Time-of-Flight (QTOF) |
| Application Scope | Universal LC-MS/MS Platform |
| Key Specifications | 50 GBit/sec acquisition rate |
| Resolution | Ultra-High Resolution TOF (UHR-TOF) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Time-of-Flight (TOF) |
| Configuration | Dual-Source GC-MS (EI + CI) |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) with Helical Resonant Plasma (HRP) source |
| Resolution | >40,000 FWHM (m/z 200) |
| Mass Accuracy | <1 ppm RMS (calibrated) |
| Scan Rate | Up to 50 spectra/sec (full-spectrum, high-res) |
| CI Reagent Gases | N₂H⁺, H₃O⁺, H(H₂O)ₙ⁺, NH₄⁺ (software-switchable, no hardware intervention) |
| Compliance | Fully compatible with GLP/GMP workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Tandem Quadrupole (Triple Quad) |
| Configuration | LC-MS/MS |
| Application Scope | Universal Quantitative Analysis |
| Regulatory Compliance | Designed for GLP/GMP environments, compatible with 21 CFR Part 11 audit trail requirements |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Tandem Quadrupole (Triple Quad) |
| Model | EVOQ® DART-TQ+ |
| Application Scope | General-purpose small-molecule screening and quantitation |
| Ionization Modes | Fully integrated DART (Direct Analysis in Real Time), swappable with VIP-HESI (Heated Electrospray Ionization) and APCI sources |
| MRM Transition Rate | Up to 1,000 transitions/sec |
| Scan Speed | Up to 30,000 Da/sec |
| Detector | EDR™ Electron Multiplier with real-time gain optimization |
| Software Platform | tqControl™ with MRM Builder, automated tuning, daily performance verification, and rule-based data review |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Quadrupole-TOF |
| Application Scope | Universal LC-MS/MS |
| Optional Features | ETD, HighMass Mode |
| Resolution (FSR) | >80,000 at full sensitivity |
| Mass Accuracy | <1 ppm RMS (calibrated, typical) |
| Mass Range | Up to 20,000 m/z (HighMass mode) |
| Isotopic Pattern Fidelity | True Isotopic Pattern (TIP) enabled |
| Software Platform | Compass DataAnalysis, Compass AutoPrep, SmartFormula™, SmartFormula 3D™ |
| Regulatory Compliance | FDA 21 CFR Part 11 compliant workflows available |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | FTMS (Fourier Transform Mass Spectrometry) |
| Model | scimaX™ |
| Resolution | R > 20,000,000 (at m/z 400) |
| Cooling System | Helium-gas-cooled Maxwell™ superconducting magnet (cryogen-free) |
| Ion Sources | Dual ESI/MALDI with automated switching |
| Fragmentation Modes | ECD, EID, ETD, CID, EDD, SORI-CID, MALDI-ISD, NETD |
| Acquisition Mode | CASI (Collision-Activated Selective Ion accumulation) |
| Application Scope | Universal — petroleumomics, phenomics, metabolomics, native proteomics, label-free MSI, fragment-based drug discovery |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | solariX |
| Instrument Type | FTMS (Fourier Transform Mass Spectrometer) |
| Magnetic Field Strength Options | 7T, 12T, 15T |
| Ionization Modes | ESI and MALDI (dual-source configurable) |
| Detection Technology | ParaCell detector with AMP (Absorption Mode Processing) |
| Software Platform | Bruker Compass suite including SmartFormula |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Model | timsMetabo™ |
| Application Scope | Universal (Metabolomics, Lipidomics, Untargeted Small-Molecule Analysis) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS)–based Mass Spectrometer |
| Model | timsOmni |
| Application Scope | Universal for native and denatured proteoforms, intact proteins, oligonucleotides, PTMs, small molecules, and multi-specific biologics |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | timsTOF fleX™ |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Scope | Universal Platform for Spatial Omics and Molecular Imaging |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Model | timsTOF fleX with MALDI-2 |
| Application Scope | Universal (Biological Tissue Imaging, Lipidomics, Metabolomics, Drug Distribution Studies) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Software Platform | SCiLS Lab, DataAnalysis, and TIMS Control integrated in Compass 6.0 suite |
| Ionization Modes | MALDI and MALDI-2 (laser post-ionization), ESI (via LC coupling) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | timsTOF HT |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Technology | Parallel Accumulation–Serial Fragmentation (PASEF®), CCS-enabled 4D-Proteomics |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometer (TIMS-TOF MS) |
| Ionization Modes | Dual MALDI/ESI |
| Application Focus | Label-free Ultra-High-Throughput Screening (uHTS) in Drug Discovery |
| Software Platform | MALDI PharmaPulse® 2023 |
| Compliance Ready | GLP/GMP-aligned data handling, 21 CFR Part 11–compatible audit trail (via optional software configuration) |
| Throughput | Up to 3 samples/sec on 1536-well plates |
| CCS Calibration | Yes, with internal standards |
| MALDI Source | 10 kHz smartbeam™ 3D laser, MALDI-2 option available |
| Sample Handling | Robotic MALDI target auto-loader, disposable targets (96–1536-well compatible) |
| Data Export | Native support for Genedata Screener®, Assay Explorer, and other HTS informatics platforms |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | timsTOF Pro 2 |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Domain | Specialized Omics Research (Proteomics, Lipidomics, Phosphoproteomics, Clinical Biomarker Discovery) |
| Regulatory Context | Compliant with GLP/GMP data integrity requirements |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometer (TIMS-TOF) |
| Model | timsTOF SCP |
| Application Domain | Specialized Single-Cell Proteomics, Immunopeptidomics, PTM Analysis, Epigenoproteomics |
| Ion Source | Optimized Dual-Orthogonal Reflectron Ion Source with 1-mm Transfer Capillary |
| Vacuum Architecture | 8-stage Differential Vacuum System |
| Acquisition Mode | dia-PASEF® (Data-Independent Acquisition Parallel Accumulation–Serial Fragmentation) |
| CCS Capability | Yes, Collision Cross Section–enabled Ion Mobility Separation |
| Scan Speed | >120 Hz MS/MS |
| Software Platform | timsControl, PaSER (Real-time Parallel Database Search Engine), Compatible with MaxQuant/Perseus, PEAKS Studio |
| Data Format | Open .d Format (Bruker) |
| Regulatory Compliance | Supports 21 CFR Part 11–compliant workflows (audit trail, electronic signatures, data integrity controls) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | timsUltra AIP |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Scope | Specialized Proteomics & Multi-Omics Platforms |
| Software Integration | TIMS PASEF®, TIMScore™, DIA-NN 4D-Proteomics™, Spectronaut® 20, ICC 2.0 |
| Brand | Elite |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Model | MS2 Vertical 9100 |
| Price Range | USD 210,000 – 325,000 (FOB China) |
| Mass Range | m/z 5–1500 |
| Sensitivity (ESI+) | ≥ 500,000:1 (S/N, 100 fg injected on-column, reserpine) |
| Maximum System Pressure | 130 MPa |
| Ionization Sources | Dual-source configuration (e.g., ESI & APCI swappable without venting) |
| Brand | Elite |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole |
| Mass Range | m/z 5–1500 |
| Sensitivity (ESI+) | ≥ 500,000:1 (S/N, 100 fg injected on-column, reserpine) |
| Maximum System Pressure | 130 MPa |
| Ionization Sources | Dual ESI/APCI Interchangeable Source |
| Software Platform | EliteChrom LC-MS Workstation |
| Brand | Elite |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | MS²Vertical 9020 |
| Price Range | USD 140,000 – 255,000 |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Application Scope | General-Purpose |
| Mass Range | m/z 5–3000 amu |
| Maximum LC System Pressure | 1300 bar |
| Brand | Elite |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole (QqQ) LC-MS/MS |
| Price Range | USD 140,000 – 255,000 (FOB) |
| Application Scope | General-purpose quantitative and qualitative analysis in regulated and research laboratories |
| Compliance | Designed to support GLP/GMP workflows and 21 CFR Part 11–compliant data integrity requirements |
| Brand | Elite |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Triple Quadrupole (QqQ) |
| Mass Range | m/z 19–2800 |
| Configuration | Integrated LC-MS/MS System |
| Application Scope | General-Purpose Quantitative and Qualitative Analysis |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Brand | EXPEC / Superspectra |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 5210 |
| Instrument Type | Triple Quadrupole (QqQ) |
| Application Scope | General-Purpose |
| Mass Range | Not Specified |
| Sensitivity | Not Specified |
| Resolution | Not Specified |
| Mass Accuracy | Not Specified |
| Operating Pressure Range | Not Specified |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | EXPEC 5310 |
| Instrument Type | Triple Quadrupole |
| Application Scope | General-Purpose |
| Brand | HEXIN MASS SPECTROMETRY |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LC-TQ 5200 |
| Instrument Type | Triple Quadrupole (Tandem Quadrupole) |
| Application Scope | General-Purpose |
| Mass Range | Available upon request |
| Sensitivity | Available upon request |
| Resolution | Available upon request |
| Mass Accuracy | Available upon request |
| Operating Pressure Range | Available upon request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | iASAP Inert Gas Atmospheric Pressure Solid Analysis Probe |
| Instrument Type | APCI Ion Source |
| Application Scope | General-Purpose |
| Mass Range | 10–2000 m/z |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine) |
| Resolution | 0.5–0.85 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Compliance | Compatible with Advion expression® CMS and compact CMS platforms |
| Brand | Ion Tec Co., Ltd. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole (QqQ) LC-MS/MS |
| Mass Range | m/z 15–2000 |
| Sensitivity | ≤0.5 pg on-column injection of reserpine (S/N ≥ 100:1 in MRM mode) |
| Resolution | >2000 (full width at half maximum, FWHM) |
| Brand | IonSense |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DART JS |
| Instrument Type | Atmospheric Pressure Ion Source |
| Application Scope | Universal |
| Mass Range | 15–6000 Da |
| Sensitivity | Low-ppt (liquid samples) |
| Resolution | Determined by coupled mass spectrometer |
| Accurate Mass Capability | Dependent on host MS platform |
| Operating Pressure | Ambient (atmospheric pressure) |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Configuration | Liquid Chromatography–Mass Spectrometry (LC-MS) Platform |
| Ionization Modes | Electrospray Ionization (ESI), Direct Analysis in Real Time (DART™), Cold Spray Ionization (CSI) |
| Intended Use | General-purpose high-resolution mass analysis in research, quality control, and regulatory-compliant laboratories |
| Compliance Context | Designed to support GLP/GMP workflows and data integrity requirements per FDA 21 CFR Part 11 and ISO/IEC 17025 guidelines |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Citius HRT |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Resolution | 100,000 (FWHM at m/z 500) |
| Acquisition Rate | 100–200 full-spectrum scans per second |
| Mass Accuracy | < 1 ppb (rms, external calibration) |
| Dynamic Range | 10⁵–10⁶ |
| Ion Sources | ESI, APCI, DESI compatible |
| Flight Path Length | 64 m (folded via FFP™ technology) |
| Calibration Modes | External standard, continuous internal standard, pseudo-external |
| Brand | Advion |
|---|---|
| Origin | USA |
| Model | TriVersa NanoMate® |
| Instrument Type | Chip-Based Nanoelectrospray Ion Source |
| Mass Range | 100 Da – 100 kDa |
| Sensitivity | Dependent on Coupled Mass Spectrometer |
| Resolution | Dependent on Coupled Mass Spectrometer |
| Accurate Mass Capability | Dependent on Coupled Mass Spectrometer |
| Compliance | ASTM E2915, ISO/IEC 17025 (when operated in GLP/GMP environments), FDA 21 CFR Part 11–ready software architecture |