Lubricating Oil Tester
Filter
Showing 1–30 of 125 results
| Brand | Ankersmid |
|---|---|
| Origin | Germany |
| Model | OilHealth Probe |
| Type | Online Instrument |
| Application | Lubricating Oil Condition Monitoring |
| Core Technology | Multi-parameter Spectroscopic Analysis (FTIR + Electrochemical RULER + Viscosity Correlation) |
| Compliance Context | Designed for ISO 4406, ASTM D7883 (RULER), ASTM E2412 (FTIR), and OEM lubricant life extension protocols |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | Aquamax KF PRO LPG |
| Application | Coulometric Karl Fischer titration for trace moisture determination in pressurized liquefied gases (LPG, LNG) and vapor-phase hydrocarbon streams |
| Detection Range | 0.1–1000 µg H₂O (equivalent to 0.1–500 ppmv in gas phase, depending on sample volume and density) |
| Sample Form | Liquid or vapor-phase, pressurized |
| Automation Level | Fully automated sample introduction, titration, rinsing, and method execution |
| Compliance | Designed per ISO 8573-3, ASTM D6304, ASTM D7429, and EN 15472 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AD0972-100 |
| Pricing | Available Upon Request |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | C100 |
| Product Type | Online Instrument |
| Detection Target | Mechanical Contaminants |
| Particle Recognition Capability | ≥4 µm |
| Compliance Support | ISO 4406, NAS 1638 |
| Compatible Fluids | Hydraulic oil, lubricating oil, fuel, mineral oil, synthetic oil, coolant, cleaning solution, cutting fluid |
| AI Engine | Trained on >500 commercial lubricant models and ferrographic particle morphology database |
| Data Output | Wired (Ethernet gateway) or Wireless (Wi-Fi/LoRaWAN) |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | C120 |
| Type | Online Instrument |
| Detection Target | Mechanical Contaminants (Wear Debris) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ISO 4406, NAS 1638 |
| Fluid Compatibility | Hydraulic Oil, Lubricating Oil, Fuel Oil, Mineral & Synthetic Oils, Coolants, Cutting Fluids, Cleaning Solutions |
| Data Transmission | Wired Ethernet Gateway / Wireless (Wi-Fi/LoRaWAN) |
| AI Engine | Trained on >500 Commercial Lubricant Models & Lab-Validated Ferrographic Image Database |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | EX S100 |
| Product Type | Online Instrument |
| Detection Parameter | Mechanical Contaminants |
| Compliance | ATEX/IECEx Certified for Hazardous Areas |
| Particle Detection Threshold | ≥4 µm |
| Output Standards | ISO 4406, NAS 1638 |
| Compatible Fluids | Hydraulic Oils, Lubricating Oils, Mineral & Synthetic Oils, Fuels, Coolants, Cutting Fluids, Aqueous Solutions |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | EXC100 |
| Product Type | Online Instrument |
| Detection Parameter | Mechanical Contaminants |
| Compliance | ATEX/IECEx Certified for Hazardous Areas |
| Particle Detection Threshold | ≥4 µm |
| Output Standards | ISO 4406, NAS 1638 |
| Compatible Fluids | Hydraulic oil, lubricating oil, fuel, mineral & synthetic oils, coolants, cleaning fluids, cutting fluids |
| Data Interface | Wired Ethernet Gateway / Wireless (Wi-Fi/LoRaWAN) |
| AI Engine | Trained on >500 commercial lubricant models and ironographic particle morphology database |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | EXS120 |
| Product Type | Online Instrument |
| Detection Target | Mechanical Contaminants (Particulate Wear Debris) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ATEX/IECEx Zone 1/21 Certified |
| Measurement Principle | AI-Enhanced Digital Image Analysis of In-Stream Oil Flow |
| Data Output | ISO 4406, NAS 1638, Wear Mode Classification (Fatigue, Cutting, Pitting, etc.) |
| Fluid Compatibility | Mineral Oils, Synthetic Lubricants, Hydraulic Fluids, Fuels, Coolants, Cleaning Solutions, and Aqueous Cutting Fluids |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OiHealth PROBE |
| Product Type | Online Instrument |
| Voltage | 24 V DC |
| Current Consumption | <200 mA |
| Digital Outputs | RS485 (Modbus RTU), Ethernet RJ45 (Modbus TCP/IP, FTP, Telnet) |
| Maximum Operating Pressure | 5 bar |
| Viscosity Range | 0–460 cSt |
| Operating Temperature | −20 °C to +80 °C |
| Ingress Protection | IP65 |
| Hydraulic Connection | 1/2″ BSP |
| Certifications | CE, GL Class pending |
| Detection Principle | Optical Absorption & Scattering Spectroscopy |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OilCMS |
| Product Type | Portable Instrument |
| Detection Parameters | Tribological Wear Analysis |
| Oil Compatibility | Synthetic, Mineral, Organic Oils & Diesel (up to 3000 cSt) |
| Standards Compliance | ISO 4406, SAE AS4059, NAS 1638 |
| Software | Rubolab Oil Condition Monitoring Suite |
| Operating Modes | Offline (Bottle Sampling) & Online (High-Pressure Flow Cell) |
| Data Export | CSV, PDF |
| Calibration | Auto-calibration via embedded oil database (500+ lubricants), field-updatable |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OilMoisture |
| Type | Online Instrument |
| Detection Target | Water Contamination in Lubricants |
| Measurement Principle | Near-Infrared (NIR) Absorption Spectroscopy |
| Compliance Context | Designed for ISO 4406, ASTM D6304, and ISO 11171-compliant condition monitoring systems |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S100 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Type | Online Monitoring Sensor |
| Detection Parameter | Mechanical Contaminants (Particulate Matter) |
| Particle Detection Threshold | ≥4 µm |
| Compliance Standards | ISO 4406:2017, NAS 1638 Class Code Calculation, ASTM D7647 (Image-Based Particle Analysis), GLP-Traceable Data Logging |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S120 |
| Product Type | Online Instrument |
| Detection Parameter | Mechanical Contaminants (Particulate Matter) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ISO 4406, NAS 1638 |
| Data Transmission | Wired Ethernet Gateway / Wireless (Wi-Fi/4G) |
| Fluid Compatibility | Hydraulic Oil, Lubricating Oil, Fuel Oil, Mineral Oil, Synthetic Oil, Coolants, Cleaning Solutions, Cutting Fluids |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Product Type | Online Instrument |
| Detection Parameters | Mechanical Contaminants (Particulate Matter) |
| Particle Detection Threshold | ≥4 µm |
| Compliance | ISO 4406, NAS 1638 |
| Fluid Compatibility | Hydraulic Oil, Lubricating Oil, Mineral Oil, Synthetic Oil, Fuel Oil, Coolants, Cutting Fluids, Cleaning Solutions |
| Data Transmission | Wired Ethernet Gateway / Wireless (Wi-Fi/4G) |
| AI Engine | Trained on >500 Commercial Lubricant Models & Iron Spectroscopy Image Database |
| Software | Cloud-Enabled Diagnostic Platform with Audit Trail & GLP/GMP-Ready Reporting |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OilWear S120 |
| Product Type | Online Instrument |
| Detection Target | Solid Contaminants & Degradation Indicators |
| Particle Size Range | ≥4 µm |
| Source Discrimination Capability | ≥20 µm (size + shape-based classification) |
| Compliance Standards | ISO 4406, SAE AS4059, NAS 1638 |
| Communication Interfaces | Analog (4–20 mA), Digital (RS-485, Modbus RTU), PLC/SCADA/PC Compatible |
| Self-Calibration & Diagnostics | Yes |
| Configurable Alarm Thresholds | Yes |
| Integrated Oil Health Monitoring | Compatible with Atten2 OilHealth Platform |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Atten2 SMK Smart Oil Filtration Kit |
| Product Type | Online Monitoring Instrument |
| Measured Parameters | Particle Contamination, Air Bubble Content, Foam Inhibitor Condition, Optional Water Content |
| Compliance Standards | ISO 4406:2017, SAE AS4059F, NAS 1638 Class |
| Power Supply | 24 V DC, <250 mA |
| Particle & Bubble Count Output | ISO Code, p/mL, b/mL |
| Volumetric Flow Visualization | L/min |
| Optional Humidity Sensor (Water-in-Oil) | ppm |
| Digital Interface | Local Display + Ethernet RJ45 (IP, FTP, Telnet) |
| Max Operating Pressure | 20 bar |
| Operating Temperature Range | 0–80 °C |
| Kinematic Viscosity Range | 0–540 cSt |
| Counting Accuracy | ±1 ISO Code |
| Enclosure Rating | IP65 |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FHV-3 |
| Pricing | Upon Request |
| Density Range | 600–1250 kg·m⁻³ |
| Viscosity Range | 1–1000 cP |
| Temperature Range | 0–100 °C |
| Density Accuracy | ±0.5% or ±5 kg·m⁻³ (whichever is greater) |
| Viscosity Accuracy | ±5% or ±1 cP (whichever is greater) |
| Dielectric Constant Accuracy | ±3% |
| Temperature Accuracy | ±0.5 °C |
| Resolution | Density 0.1 kg·m⁻³ |
| Response Time | <30 s (initial stabilization), 1 Hz data refresh rate |
| Output | RS485 MODBUS RTU |
| Power Supply | 9–32 VDC |
| Current Draw | <20 mA @ 24 VDC |
| Max Process Pressure | 10 bar (custom options available) |
| Fluid Temp. | 0–100 °C |
| Ambient Temp. | −40 to +85 °C |
| Storage Temp. | −40 to +100 °C |
| Housing Material | 316/304 stainless steel or Hastelloy C-276 |
| Mechanical Interface | G3/4″ |
| IP Rating | IP65 |
| Sealing Material | FKM fluoroelastomer |
| Cable | 2 m M8 6-pin |
| Max Flow Velocity | <0.1 m/s |
| Compliance | CE, ASTM D1657, EN 61326-1, EN 61326-2-3, ICES-003 Class B, National Metrology Verification Report |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FYH |
| Pricing | Available Upon Request |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | KLD-3 / KLD-4 / KLD-5 |
| Detection Parameter | Particle Count & Contamination Level (NAS 1638) |
| Sample Volume | 10 mL |
| Compliance Standard | NAS 1638 |
| Power Supply | Integrated Rechargeable Battery |
| Display | Color LCD with Numeric and Graphical Output |
| Data Output | Built-in Thermal Printer |
| Application Focus | Lubricating Oil Condition Monitoring |
| Category | Petroleum-Specialized Analytical Instrument for In-Service Oil Analysis |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | KLD-BA |
| Detection Principle | Light Obscuration (LO) |
| Compliance Standards | NAS 1638, GJB 420B, ISO 4406 |
| Sample Types | Hydraulic oil, lubricating oil, transformer oil, turbine oil, gear oil, engine oil, aviation kerosene, water-based hydraulic fluids, organic solvents, polymer solutions |
| Sensor Type | KLD-TC laser obscuration sensor |
| Display | 7-inch capacitive touchscreen (Android OS) |
| Data Storage | Internal database with timestamped records |
| Output | Thermal printer module, USB interface for data export and firmware updates |
| Sampling System | Precision metering pump with volumetric accuracy control |
| Calibration Curves | Three user-selectable curves (ACFTD, ISO MTD, GOST) |
| Reporting Standards | Built-in support for ISO 4406, NAS 1638, GJB 420A–1996, GJB 420B–2006, and seven additional particle contamination classification schemes |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KLD-Z-X |
| Detection Parameter | Particulate Contamination (Solid Particle Count) |
| Flow Range | 50–300 mL/min |
| Weight | 538 g (with display) |
| Power Supply | DC 12–24 V (ripple <30 mVp-p) |
| Dimensions | 94 × 87 × 46 mm |
| Operating Temperature | −20 °C to +60 °C |
| Media Temperature | −20 °C to +80 °C |
| Pressure Range | 3–30 MPa (high-pressure channel) / 0.3–3 MPa (low-pressure channel) |
| Humidity | 20–85% RH (operating, non-condensing) |
| Communication Interface | RS485 / RS232 |
| Repeatability | ±0.5 ISO contamination code |
| Channel Configuration | 4-channel or 6-channel (field-configurable) |
| Thread Specification | M10×1 mm |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | YSF-1 |
| Measurement Principle | Capacitive Water Activity (a<sub>w</sub>) Sensing with Integrated Temperature Compensation |
| Output Signals | RS232 serial interface, 4–20 mA analog output |
| Relay Outputs | 2 programmable alarm channels |
| Display | Real-time a<sub>w</sub> (0.01–1.00), temperature (°C), and calculated absolute water content (ppm) |
| Calibration | Dual-point calibration support for traceable accuracy |
| Portability | Handheld or inline mounting configuration |
| Compliance Context | Designed for routine condition monitoring per IEC 60814, ASTM D6304 (Karl Fischer correlation), and IEEE C57.106 guidance for transformer oil moisture assessment |
| Brand | CINRG |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CS-APC-2 |
| Product Category | Laboratory Instrument |
| Test Parameter | Contaminant Particles |
| Compliance | ASTM D7647-10 |
| Sample Processing Time | 4–5 min/sample |
| Solvent Consumption | 40 mL/sample |
| Autosampler Capacity | 102 samples (104-position tray |
| Sensor Model | KLOTZ LDS 45/50 Laser Sensor |
| Measurement Range | 1.5 µm – 100 µm |
| Flow Rate | 30 mL/min (calibrated) |
| Detection Thresholds | 25,000 particles/mL at ≥4 µm (neat oil), 50,000 particles/mL at ≥4 µm (1:1 dilution) |
| Volume Accuracy | ±2% (pre-dilution) |
| Customizable Reporting | User-defined pass/fail limits at 4 µm, 6 µm, and 14 µm |
| Data Export Fields | Solvent blank count, sample volume, dilution ratio, raw particle counts per channel |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Portable Instrument |
| Model | A1030 |
| Detection Target | Particulate Contaminants in Hydraulic & Lubricating Oils |
| Microscope Magnification | 100× |
| Particle Size Range | 5–150 µm |
| Cleanliness Rating Scales | NAS 1638 (Classes 00–12) and ISO 4406:2021 (Codes 1–24) |
| Filter Membrane Pore Sizes | 1.2 µm and 5 µm |
| Compliance Standard | DL/T 432–1992 |
| Brand | Delite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | A1460 |
| Product Category | Laboratory Instrument |
| Test Parameter | High-Temperature High-Shear Viscosity (HTHS) |
| Applicable Standards | SH/T 0703, ASTM D5481 |
| Power Supply | 220 V, 50 Hz |
| Temperature Control Method | Aluminum Block Bath |
| Test Temperature | 150 ± 0.1 °C |
| Capillary Inner Diameter | 0.15 mm |
| Capillary Effective Length | 16–18 mm |
| Gas Pressure Range | 0.5–3.5 MPa |
| Number of Capillary Cells | 1 |
| Detection Principle | Pressure-Driven Capillary Flow under Controlled Thermal and Shear Conditions |
| Automation | Fully Automated Timing, Pressure Stabilization Monitoring, HTHS Viscosity Calculation & Reporting |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | aqua 40.00 |
| Measurement Range | 1 µg – 100 mg |
| Resolution | 0.1 µg |
| Repeatability | ±3 µg (for 10–1000 µg water) |
| Temperature Control Range | 35 °C – 300 °C |
| Power Supply | 230 V |
| Sample Introduction | Optional automated sample changer |
| Gas System | Closed-loop, carrier-gas-free dynamic headspace |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software support |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aquamax KF PRO OIL |
| Product Type | Laboratory Instrument |
| Measurement Parameter | Trace Water Content (ppm to %) |
| Compliance | ASTM D6304, GB/T 11133 |
| Measurement Range | 0.0001–99% w/w |
| Heating Temperature Range | 35–250 °C (isothermal or programmable ramp) |
| Sample Introduction | Direct injection into heated furnace |
| Carrier Gas | Not required (closed-loop system) |
| Reagent Consumption | Single reagent cartridge supports >1000 determinations |
| Water Speciation | Differentiates free water and chemically bound water via thermal profiling |
| Blank-Free Operation | Eliminates need for blank correction |
| Form Factor | Benchtop / Portable field unit |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | TAN/TBN Titrator |
| Application Standard Compliance | IEC 62021-1, ISO 3771, ASTM D664, ASTM D2896, ASTM D4739 |
| Titration Method | Potentiometric Volumetric Titration in Anhydrous Medium |
| Measurement Range | 0.01–250 mg KOH/g |
| Resolution | 0.01 mg KOH/g |
| Power Supply | 100–240 V AC, 50/60 Hz, 30 VA |
| Stirrer Output | 12 V DC, 500 mA |
| Dimensions (W × H × D) | 30 × 45 × 30 cm (including reagent changer height) |
| Weight | ~3.5 kg (with reagent changer and empty bottles) |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC OIL |
| Product Type | Portable Instrument |
| Detection Parameters | Oxidation, Nitration, Sulfation, Ester Degradation, Phosphorylation, Anti-wear Additives, Antioxidants, Water, Ethylene Glycol, Gasoline, Diesel, TAN, TBN, Viscosity (40 °C & 100 °C) |
| Compliance | ASTM E2412, ASTM D7412, D7414, D7415, D7418, D7624, JOAP, DIN 51452, DIN 51453 |
| Sample Volume | 10 mL |
| Spectral Range | 450–7000 cm⁻¹ |
| Data Points | 16,384 |
| Measurement Time | 60 s |
| Display | 7″ Color Touchscreen |
| Power Supply | 85–264 V AC / 12 V DC (7 A) |
| Dimensions | 22 × 32 × 28 cm |
| Weight | 8 kg |
| Interfaces | 5× USB, 1× Ethernet, 1× RS232, LIMS-ready |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 000-001-305 |
| Test Method Compliance | ASTM D2670, D2625, D3233, D5620 |
| Load Range | 200–3000 lbf (±2% FS) |
| Rotational Speed | 290 ± 10 rpm |
| Torque Measurement | 0–100 in-lb (±2% FS) |
| Wear Resolution | 0.001 inch (0.025 mm) per 14.4 ratchet clicks |
| Operating Temperature | Ambient to 100 °C |