Lubricating Oil Tester
Filter
Showing 31–60 of 182 results
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | aqua 40.00 |
| Measurement Range | 1 µg – 100 mg |
| Resolution | 0.1 µg |
| Repeatability | ±3 µg (for 10–1000 µg water) |
| Temperature Control Range | 35 °C – 300 °C |
| Power Supply | 230 V |
| Sample Introduction | Optional automated sample changer |
| Gas System | Closed-loop, carrier-gas-free dynamic headspace |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software support |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aquamax KF PRO OIL |
| Product Type | Laboratory Instrument |
| Measurement Parameter | Trace Water Content (ppm to %) |
| Compliance | ASTM D6304, GB/T 11133 |
| Measurement Range | 0.0001–99% w/w |
| Heating Temperature Range | 35–250 °C (isothermal or programmable ramp) |
| Sample Introduction | Direct injection into heated furnace |
| Carrier Gas | Not required (closed-loop system) |
| Reagent Consumption | Single reagent cartridge supports >1000 determinations |
| Water Speciation | Differentiates free water and chemically bound water via thermal profiling |
| Blank-Free Operation | Eliminates need for blank correction |
| Form Factor | Benchtop / Portable field unit |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | TAN/TBN Titrator |
| Application Standard Compliance | IEC 62021-1, ISO 3771, ASTM D664, ASTM D2896, ASTM D4739 |
| Titration Method | Potentiometric Volumetric Titration in Anhydrous Medium |
| Measurement Range | 0.01–250 mg KOH/g |
| Resolution | 0.01 mg KOH/g |
| Power Supply | 100–240 V AC, 50/60 Hz, 30 VA |
| Stirrer Output | 12 V DC, 500 mA |
| Dimensions (W × H × D) | 30 × 45 × 30 cm (including reagent changer height) |
| Weight | ~3.5 kg (with reagent changer and empty bottles) |
| Brand | Fuland (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDY-0808 |
| Application Category | Laboratory Instrument for EV Thermal Management Fluid Evaluation |
| Compliance Standard | GB/T 29743.2 Annex C |
| Temperature Range | 0–100 °C (±1 °C accuracy) |
| Flow Rate | ≥30 L/min (adjustable, resolution 0.1 L/min) |
| Pressure Range | 0–500 kPa |
| Maximum Runtime | 9999 h (programmable, supports 1064 h continuous test cycles) |
| Data Storage Capacity | >200 test records |
| Pump Type | High-Temperature Automotive Electronic Water Pump (head ≥11 m, inlet/outlet diameter 20 mm) |
| Test Components | Aluminum Battery Cold Plate (≥1 m²), Aluminum Motor Housing with Integrated Cooling Channels, Aluminum Electronic Control Cooling Module |
| Fluid Path Material | Stainless Steel Fittings with Visual Observation Window |
| Thermal Insulation | Multi-layer External Jacket (reduces surface temperature & external thermal radiation) |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERASPEC OIL |
| Product Type | Portable Instrument |
| Detection Parameters | Oxidation, Nitration, Sulfation, Ester Degradation, Phosphorylation, Anti-wear Additives, Antioxidants, Water, Ethylene Glycol, Gasoline, Diesel, TAN, TBN, Viscosity (40 °C & 100 °C) |
| Compliance | ASTM E2412, ASTM D7412, D7414, D7415, D7418, D7624, JOAP, DIN 51452, DIN 51453 |
| Sample Volume | 10 mL |
| Spectral Range | 450–7000 cm⁻¹ |
| Data Points | 16,384 |
| Measurement Time | 60 s |
| Display | 7″ Color Touchscreen |
| Power Supply | 85–264 V AC / 12 V DC (7 A) |
| Dimensions | 22 × 32 × 28 cm |
| Weight | 8 kg |
| Interfaces | 5× USB, 1× Ethernet, 1× RS232, LIMS-ready |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 000-001-305 |
| Test Method Compliance | ASTM D2670, D2625, D3233, D5620 |
| Load Range | 200–3000 lbf (±2% FS) |
| Rotational Speed | 290 ± 10 rpm |
| Torque Measurement | 0–100 in-lb (±2% FS) |
| Wear Resolution | 0.001 inch (0.025 mm) per 14.4 ratchet clicks |
| Operating Temperature | Ambient to 100 °C |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 001-001-331 |
| Test Type | Friction and Wear |
| Load Capacity (Standard) | 805 lbf |
| Load Capacity (Optional) | 1300 lbf |
| Speed Range | Programmable RPM Control |
| Temperature Range (Standard Chamber) | Ambient to 200 °C |
| Temperature Range (Pressurized Chamber, Optional) | Ambient to 250 °C |
| Sub-ambient Testing | Available with External Chiller |
| Friction Force Measurement Range (Standard) | 0–250 lbf |
| Friction Force Measurement Range (Optional Low-Load Sensor) | 0–25 lbf |
| Compliant Standards | ASTM D2714, D2981, D3704, D2509, D2782, G77 |
| Test Geometries | Block-on-Ring, Conforming Block-on-Ring, Timken Canted Cylinder, Chip-on-Ring, Ball-on-Ring |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 006‐001‐330 |
| Testing Type | Friction and Wear |
| Compliance | ASTM D3702, D2266, D4172, D5183, G99 |
| Speed Range | 30–3600 rpm (standard), 0.01–10,000 rpm (with optional gear reducer) |
| Load Range | 1–160 lbf (2:1 lever), 20–800 lbf (10:1 lever) |
| Temperature Range | Ambient to 150°C (standard), 30–200°C (with optional heating/cooling modules) |
| Control | Computer-controlled servo motor, pneumatic auto-loading (programmable), real-time torque & displacement monitoring |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 016-001-002 |
| Test Method Compliance | ASTM D3336, SH/T 0428 |
| Maximum Rotational Speed | 20,000 rpm (light-load condition) |
| Axial Load Capacity | 15 lbs (mechanically applied) |
| Heating Chamber Max Temperature | 371 °C |
| Torque Measurement | Digital display with high/low torque shutdown threshold |
| Drive Motor | Dual 1 HP, single-phase AC motors with thermal protection |
| Timing Control | Digital on/off elapsed-time counter |
| Standard Shaft | CRC-type shaft |
| Application Focus | Grease-lubricated ball bearing life evaluation under accelerated thermal–mechanical stress |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 081-001-005 |
| Test Principle | Oscillating Ball-on-Cylinder Tribometry |
| Applied Load | 2450 N (550 lbf) |
| Test Duration | 22 h |
| Oscillation Frequency | 30.0 Hz (1800 cpm) |
| Compliance Standards | ASTM D4170, SH/T 0716 |
| Optional Feature | Load Uniformity Adjustment System |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 089-001-001 |
| Testing Mode | Wear, Extreme Pressure (EP), and KRL Rolling Fatigue |
| Speed Range | 1–2500 rpm |
| Load Range | 1–1000 kg (standard) |
| optional low-load system | 0–150 ±0.2 kg |
| Compliance | ASTM D2266, D4172, D5183, D2596, D2783 |
| Safety | Interlocked pneumatic loading enclosure |
| Control | Touchscreen interface with programmable cycle counter and elapsed time timer |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 002‐001‐003 |
| Testing Principle | Timken EP Test (ASTM D2509, ASTM D2782, SH/T 0203) |
| Maximum Applied Load | 92,300 psi (on 0.022 in. wide Timken test block) |
| Rotational Speed | 800 rpm ± 5 rpm (adjustable up to 850 rpm) |
| Test Duration | 10 min ± 15 s |
| Temperature Control Range | Ambient to 120 °C (digital PID controller with fluid circulation system) |
| Oil Reservoir Capacity | 3 L (heated, pumped, valve-controlled |
| Grease Auto-Feeder Rate | 45 ± 9 g/min |
| Drive Motor | 2 HP, unidirectional, with RPM display |
| Load Application | Static load via 10:1 lever arm |
| Sample Types | Liquid lubricants and greases |
| Compliance | ASTM D2509, ASTM D2782, SH/T 0203 |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | FYH-M |
| Pricing | Available Upon Request |
| Brand | Spectro Scientific |
|---|---|
| Origin | USA |
| Model | FieldLab 58C |
| Product Type | Portable Instrument |
| Detection Modules | XRF Elemental Analysis |
| Test Time per Sample | <10 minutes |
| Sample Volume Required | 12 mL |
| Compliance | ASTM D6595, D7690, D7883, D445 |
| Interface | Touchscreen with Embedded Diagnostic Software |
| Power | Rechargeable Battery |
| Enclosure | Ruggedized Transport Case Integrating All Four Modules |
| Brand | FlanD / csfriend |
|---|---|
| Origin | Hunan, China |
| Model | FDH-1502 |
| Applicable Standards | GB/T 9171, ASTM D4684, SH/T 0562 |
| Temperature Range | –50 °C to +80 °C |
| Sample Capacity | 9-position test block |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Cooling System | Imported compressor-based refrigeration unit |
| Detection Method | Optical encoder-based rotor speed measurement |
| Control Interface | Touchscreen with bilingual (English/Chinese) OS |
| Software | FLD proprietary BPT analysis software with real-time timing, auto-diagnosis, and single-point calibration capability |
| Optional Feature | Integrated nitrogen purge port |
| Design | Integrated monolithic chassis |
| Brand | Fluoride (csfriend) |
|---|---|
| Origin | Hunan, China |
| Model | FDY-0801 |
| Liquid Flow Rate | 1.3–1.6 L/s |
| Temperature Control | 88 °C ±3 °C |
| Test Duration | 1064 h |
| Heating Power | 2.6 kW |
| Motor Power | 2.2 kW |
| System Pressure Range | 80–103 kPa |
| Total Power Consumption | 4.8 kW |
| Supply Voltage | AC 380 V ±10%, 50 Hz |
| Net Weight | 180 kg |
| Brand | Fluoride (csfriend) |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FDH-1906 |
| Product Category | Laboratory Instrument |
| Input Voltage | AC 220 V ±10%, 50 Hz |
| Input Power | 2 kW |
| Temperature Control Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Timing Range | 0–100 h |
| Brand | Freeland / csfriend |
|---|---|
| Origin | Hunan, China |
| Model | FDH-0171 |
| Power Supply | AC 220 V ±10% |
| Heating Power | 2500 W |
| Pressure Sensor Range | 0–1.6 MPa, Accuracy: ±0.2% FS |
| Oil Bath Temperature Range | Ambient to 200.0 °C (adjustable), Typical Test Temp: 150.0 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Dual-Bomb Configuration | Yes |
| Rotation Speed | 100 ±5 rpm |
| Bomb Tilt Angle | 30° from Horizontal |
| Oil Bath Volume | 30 L |
| Dimensions (W×D×H) | 664 × 574 × 920 mm |
| Weight | ~45 kg |
| Brand | Fuland (CSFriend) |
|---|---|
| Model | FDH-8461 |
| Application | HTHS viscosity measurement of lubricating oils |
| Standard Compliance | ASTM D5481, SH/T 0703 |
| Temperature Range | Ambient to 150 °C |
| HTHS Viscosity Range | 0.5–8 mPa·s at 150 °C |
| Pressure Control Range | 3.5–35 kgf/cm² |
| Sample Volume | 10 mL |
| Pressure Display | Digital pressure gauge |
| Time Measurement | Digital timer |
| Control Method | Integrated microprocessor-based PID temperature & pressure regulation |
| Power Supply | AC 220 V, 50 Hz |
| Safety | FTC thermal cut-off circuit |
| Sample Handling | Individual stopcock valve per capillary cell |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Product Type | Portable Instrument |
| Standard Compliance | DIN 51805 |
| Temperature Range | –60 to +30 °C |
| Temperature Accuracy | ±0.1 °C |
| Pressure Measurement Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W |
| Dimensions (W×H×D) | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Interface | RS232 |
| Display Languages | English, German |
| Cooling Method | Peltier-based thermoelectric control |
| Sample Handling | Standalone operation, no auxiliary equipment required |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Application Standard | DIN 51805 |
| Temperature Range | –60 °C to +30 °C |
| Temperature Accuracy | ±0.1 °C |
| Pressure Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W or 12 V DC / 10 A |
| Dimensions (W×H×D) | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Interface | RS232 |
| Display Languages | English, German |
| Cooling Method | Peltier-based |
| Sample Compatibility | NLGI Grades 000–3 Greases |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Test Principle | Corrosion-Resistant Capillary Extrusion (DIN 51805) |
| Temperature Range | −50 °C to +30 °C |
| Temp. Accuracy | ±0.1 °C |
| Pressure Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Dimensions | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W or 12 V DC (optional) |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BT-MOD1 |
| Product Category | Laboratory Instrument |
| Test Scope | Oxidative Stability Assessment of Aviation Lubricants and Fuels |
| Compliance | UK Defence Standard 05-50 Part 61 (Gas Turbine Engine Synthetic Lubricants) |
| Temperature Range | Ambient +10 °C to 450 °C |
| Temperature Display Resolution | 0.1 °C |
| Module Temperature Uniformity | ±0.5 °C |
| Heating Capacity | 2500 W @ 230 V, 50/60 Hz |
| Control Unit Dimensions (L×W×H) | 290 × 261 × 150 mm |
| Heating Module Dimensions (L×W×H) | 460 × 310 × 275 mm |
| Operating Ambient | 10–35 °C |
| Safety Features | Dual-stage overtemperature cut-off with visual alarm (red LED flash) |
| Sample Configuration Options | 3 × Ø57 mm × 140 mm deep test vessels OR 12 × Ø28.5 mm × 140 mm deep air-cooled condenser tubes with oxidation induction ports |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BT-MOD1 |
| Pricing | Available Upon Request |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | HFN-B |
| Measurement Principle | Capillary Efflux (ASTM D445 / ISO 3104 compliant) |
| Temperature Control | 40 °C ± 0.1 °C |
| Sample Volume | 80 µL |
| Measurement Time | ≤ 30 s per test |
| Viscosity Range | 2–1000 mm²/s (cSt) at 40 °C |
| Calibration | Multi-point viscosity standard calibration (certified mineral oil standards) |
| Display | 7-inch capacitive touchscreen |
| Power | Rechargeable Li-ion battery (≥ 8 h continuous operation) |
| Cleaning | Solvent-free — dry wipe with lint-free industrial cloth |
| Compliance | Designed to support ASTM D445, ISO 3104, and ISO 2909 procedures for kinematic viscosity determination |
| Brand | Huake Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HK-3080XS |
| Price Range | USD 4,200 – 7,000 |
| Product Category | Laboratory Instrument |
| Test Parameter | Rust Inhibition Performance (Rust Rating) |
| Compliance Standard | GB/T 11143–2008 |
| Display | 800×480 Color TFT Touchscreen (Bilingual: English/Chinese) |
| Sample Stations | 4 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Timing Range | 0–99 h (programmable) |
| Stirring Speed | 1000 rpm |
| Power Supply | AC 120 V / 220–240 V, 50/60 Hz |
| Max Power Consumption | ≤2650 W |
| Dimensions (L×W×H) | 490 × 403 × 622 mm |
| Net Weight | 65 kg |
| Safety Features | Auto Liquid-Level Detection, Dry-Run Protection, Over-Temperature Alarm |
| Interface | USB for firmware update |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BLB701 / BLB702 / BLB DIN |
| Product Type | Laboratory Instrument |
| Test Parameter | Low-Temperature Apparent Viscosity (ASTM D2983, IP 295, GB/T 6538) |
| Compliance | ASTM D2983, IP 295, GB/T 6538 |
| Dimensions (W×D×H) | 48 × 53 × 66 cm |
| Weight | ~68 kg |
| Voltage | 220 VAC, 50/60 Hz, Single Phase |
| Fuse Rating | BLB701: 10 A |
| BLB702 | 2 × 10 A |
| BLB-DIN | 12 A max |
| Cooling Capacity | 600 W at 0 °C, 300 W at −40 °C, 100 W at −70 °C |
| Heating Capacity | 600 W |
| Temperature Range | BLB701: 30 °C to −40 °C |
| BLB702 | 30 °C to −70 °C |
| BLB-DIN | 30 °C to −55 °C |
| Viewing Window | ~41 × 23 cm |
| Sample Capacity | 12-position bath |
| Bath Volume | 3.8 L |
| Safety Features | High-pressure cutoff, over-temperature limit, low-fluid-level detection and auto-shutdown |
| Certification | CE |
| Shipping Weight | 122–136 kg |
| Shipping Dimensions | 81 × 76 × 104 cm |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Model | MRV TP-1 |
| Standards Compliance | ASTM D4684 (Method A), SH/T 0562 |
| Temperature Range (BLB702) | 30 °C to −70 °C |
| Cooling Power | 600 W at 0 °C, 100 W at −40 °C, 300 W at −70 °C |
| Heating Power | 600 W |
| Sample Capacity | 12-position bath |
| Bath Volume | 3.8 L |
| Dimensions (W×D×H) | 48 cm × 53 cm × 66 cm |
| Net Weight | ~68 kg |
| Transport Weight | 122–136 kg |
| Transport Dimensions | 81 cm × 76 cm × 104 cm |
| Electrical Supply | 220 VAC, 50/60 Hz, Single Phase |
| Safety Certifications | CE, High-Temp Cut-off, Low-Level Fluid Detection, Over-Pressure Breaker |
| Viewing Window | 41 cm × 23 cm |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | KLD-B-2 |
| Pricing | Available Upon Request |
| Brand | Beijing Hangfeng |
|---|---|
| Origin | Beijing, China |
| Model | KLD-O-S |
| Product Type | Online Analyzer |
| Detection Parameters | Particle Contamination & Water Content (Relative Humidity) |
| Compliance Standards | ISO 4406, GJB 420B, NAS 1638 |
| Flow Rate | 50–120 mL/min |
| Power Supply | DC 10–26 V (Ripple < 100 mVp-p) |
| Dimensions | 105 × 89 × 64 mm |
| Weight | 538 g |
| Operating Temperature | −20 to +60 °C |
| Storage Temperature | −20 to +80 °C |
| Pressure Rating | < 1 MPa |
| Humidity Range (Operating) | 20–85% RH (non-condensing) |
| (Storage) | up to 98% RH |
| Communication Interface | RS-485 / RS-232 |
| Repeatability | ±0.5 ISO Code |
| Moisture Measurement Range | 0–100% RH |
| Temperature Sensing Range | −20 to +80 °C |
| Channel Configuration | 4- or 6-channel, auto-adaptive |
| Display | OLED with wide viewing angle |
| Input Control | Dedicated tactile keys for分级 navigation and parameter configuration |
| Alarm Function | Real-time contamination level alerting based on ISO 4406 thresholds |
| Bubble Discrimination | Patented full-spectrum optical discrimination algorithm for bubble rejection |
| Flow Compensation | Onboard real-time flow rate calculation and viscosity-corrected particle counting |