| Brand | MembraPure |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | A300 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | ≤10 °C (default operating temperature) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | membraPure |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Post-Column Derivatization Amino Acid Analyzer |
| Model | PR-200A |
| Pump Flow Rate | 0.001–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | ≤10 °C (default operating temperature) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | <8 µL |
| Brand | membraPure |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | IONUS |
| Instrument Type | Laboratory |
| Column Temperature Control | Peltier-based, 20–100 °C (±0.1 °C) |
| Detector | Conductivity, Flow Cell Volume: 0.10 μL |
| Baseline Noise | 0.004 μS/cm |
| Baseline Drift | 0.025 μS/cm |
| Output Range | 0.1–5250 μS/cm FS |
| Gain Steps | 0.1 / 1.0 / 10 μS/cm |
| Range Multipliers | 1–512 (binary scaling) |
| Signal Output | 0–5 V analog |
| Ambient Operating Temp | 10–37 °C |
| Auto-zero Function | Yes |
| Column Materials | Stainless Steel or PEEK |
| Resin Particle Size | 3 μm (anion & cation exchange) |
| Optional Autosampler | COLIBRI with XYZ robotic arm, Peltier-cooled to 8 °C, 2×54-position (1.5 mL) or dual 96-well microplates, Injection Volume: 1–40 μL (1 μL increments, programmable) |
| Data Software | iPeak |
| Interfaces | 2× USB, Analog Conductivity Output |
| Tubing & Fluidic Path | PEEK or FEP |
| Inert Gas Protection | Integrated for carbonate eluent stabilization |
| Brand | membraPure |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | A388 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | Default Operating Temperature <10 °C |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | membraPure |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Post-Column Derivatization Amino Acid Analyzer |
| Model | A300-Advanced |
| Pump Flow Rate | 0.001–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | ≤10 °C (default operating temperature) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 440 nm and 570 nm |
| Flow Cell Volume | <8 µL |
| Brand | MembraPure |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | V388s Series |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | ≤10 °C (default operating temperature) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |