| Brand | MembraPure |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | A300 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | ≤10 °C (default operating temperature) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | membraPure |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Post-Column Derivatization Amino Acid Analyzer |
| Model | PR-200A |
| Pump Flow Rate | 0.001–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | ≤10 °C (default operating temperature) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | <8 µL |
| Brand | membraPure |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | A388 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | Default Operating Temperature <10 °C |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | membraPure |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Post-Column Derivatization Amino Acid Analyzer |
| Model | A300-Advanced |
| Pump Flow Rate | 0.001–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | ≤10 °C (default operating temperature) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 440 nm and 570 nm |
| Flow Cell Volume | <8 µL |
| Brand | MembraPure |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | V388s Series |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | ≥40 MPa |
| Autosampler Injection Modes | Direct Injection / Full-Loop Injection / Partial-Loop Injection |
| Autosampler Temperature Control | ≤10 °C (default operating temperature) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |