| Brand | 4titude |
|---|---|
| Origin | Taiwan |
| Model | A4s |
| Automation Level | Fully Automatic |
| Sealing Capacity | Up to 5,000 cycles unattended |
| Seal Cycle Time | <15 s |
| Sealing Temperature Range | 100–195 °C |
| Sealing Time Range | 0.1–10 s |
| Dimensions (W×L×H) | 230 × 507 × 276 mm |
| Weight (without film roll) | 27 kg |
| Power Input | AC 100–240 V, DC 24 V / 320 W |
| Max Power Consumption | 700 W |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 0–85% RH |
| Interface | RS-232, USB |
| Compliance | SiLA 2.0 compatible, SBS-compliant footprint support (96–1536-well), GLP/GMP-ready audit trail via software logging |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 405 LS |
| Soaking Time | 1–600 seconds |
| Wash Cycles | 1–10 |
| Residual Volume | <2 µL per well |
| Plate Shaking | User-definable speed and duration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 405 TS |
| Instrument Type | Multifunctional Microplate Washer |
| Wash Head Design | Dual-Action Wash Head |
| Fluid Channels | 96-well and 192-channel parallel dispensing/suction |
| Soak Time Range | 0–60 minutes |
| Wash Cycles | 1–250 cycles per protocol |
| Residual Volume per Well | ≤2 µL |
| Plate Shaking | Four Adjustable Intensity Levels (Low, Medium, High, Variable) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | BioTek 406 FX |
| Instrument Type | Multi-Function Plate Washer and Dispenser |
| Sample Format Compatibility | 96-well to 1536-well microplates |
| Dispensing Technology | Non-contact positive displacement (4 syringe pumps) and peristaltic pumping (2 channels) |
| Wash Head | Dual-Action™ with adjustable aspiration/dispense height, X/Y positioning, and angled dispensing nozzles |
| Waste Disposal | Direct drain waste system |
| Automation Interface | Left- and right-side robotic arm access |
| Software Options | LHC Control Software and LHC Secure Software (21 CFR Part 11 compliant) |
| Magnetic Separation Support | Optional magnetic plate adapter |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Product Category | Imported Instrument |
| Model | 50TS |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head Configurations | 4-, 8-, 12-, or 16-channel selectable |
| Wash Fluid Ports | 4-, 8-, 12-, or 16-needle manifold |
| Soak Time | User-definable |
| Wash Cycles | 1–10 cycles |
| Orbital Shaking | Programmable intensity (5 levels) and duration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 800 TS |
| Function Type | Absorbance-Only Microplate Reader |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, and Scanning |
| Curve Fitting Options | Multiple nonlinear regression models (e.g., 4PL, 5PL, linear, quadratic, log-log) |
| Detector Type | Photodiode-based UV-Vis spectrophotometric detector |
| Wavelength Range | 400–750 nm standard |
| Absorbance Range | 0–4.0 OD |
| Absorbance Linearity | ±1.0% ± 0.010 OD (0–2.0 OD at 405 nm) |
| Plate Read Time | 11 seconds per 96-well plate |
| Precision | ±1.0% ± 0.010 OD (0–2.0 OD at 405 nm) |
| Incubation Temperature | Up to 50 °C |
| Orbital Shaking | Linear and orbital modes |
| Supported Plate Formats | 6-, 12-, 24-, 48-, 96-, 384-well microplates |
| Filter Capacity | 5-position filter wheel |
| Onboard Storage | Internal memory + USB export capability |
| Software Platform | Integrated touchscreen interface + compatibility with Agilent BioTek Gen5 v3.11 or later |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Product Category | Imported Instrument |
| Model | EL406 |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Epoch |
| Function Type | Absorbance-Only Microplate Reader |
| Automation Level | Fully Automated |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 200–999 nm |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Epoch2 |
| Function Type | UV-Vis Absorbance-Only Microplate Reader |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Spectral Scan |
| Curve Fitting Options | Linear, Quadratic, Cubic, Four-Parameter Logistic (4PL), Five-Parameter Logistic (5PL), Log-Log, Spline |
| Detector Type | UV-Visible Photodiode Array |
| Wavelength Range | 200–999 nm (1 nm increments) |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | ±1% ± 0.01 OD (0–2 OD) |
| Plate Read Time | 8 sec (96-well), 14 sec (384-well) |
| Precision | ±1% ± 0.01 OD (0–2 OD) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Synergy H1 |
| Pricing | Upon Request |
| Functionality | Multi-Mode |
| Automation Level | Fully Automated |
| Assay Methods | Endpoint, Kinetic, Wavelength Scan, Well Area Scan |
| Curve Fitting Options | Linear, Logarithmic, Four-Parameter Logistic (4PL), Five-Parameter Logistic (5PL) |
| Detector Type | Photomultiplier Tube (PMT) / Photodiode (PD) |
| Wavelength Range | Filter-based: 200–700 nm |
| Monochromator-based | 250–900 nm |
| Absorbance Range | 0.0000–4.0000 OD |
| Absorbance Linearity | Not Specified |
| Read Speed | 96-well plate in 11 s |
| Accuracy | Not Specified |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Synergy HTX |
| Function Type | Multi-Mode |
| Automation Level | Fully Automated |
| Assay Methods | Endpoint, Kinetic, Well-Scanning |
| Curve Fitting Options | Linear, Point-to-Point, Four-Parameter Logistic (4PL) |
| Detector Types | Fluorescence, UV-Vis Absorbance, Luminescence, Time-Resolved Fluorescence (TRF), AlphaScreen/AlphaLISA |
| Wavelength Range | Filter-Based: 200–850 nm |
| Monochromator-Based | 200–999 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | <1% deviation from ideal linearity across 0–3.0 OD |
| 96-Well Read Time | 14 seconds |
| Absorbance Precision | ±0.0001 OD |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Synergy LX |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Well-Scanning |
| Curve Fitting Options | Linear, Point-to-Point, Four-Parameter Logistic (4PL) |
| Detector Types | UV-Vis Absorbance, Fluorescence Intensity, Luminescence |
| Wavelength Range | Filter-Based: 320–850 nm |
| Monochromator-Based | 200–999 nm |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | <1% deviation from ideal over 0–2.5 OD |
| Read Time (96-well plate) | 12 s |
| Absorbance Precision | ±0.0001 OD |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | BioTek Synergy Neo2 Hybrid |
| Detection Methods | Absorbance, Fluorescence Intensity (tunable bandwidth), Luminescence, Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP), TR-FRET, BRET, AlphaScreen/AlphaLISA |
| Detector Types | Dual Photomultiplier Tubes (PMTs), Monochromator-based and Filter-based Optical Paths, 337 nm Pulsed Laser for TRF, 100 mW Solid-State Laser for Alpha Detection |
| Automation | Fully Automated with BioStack Neo |
| Environmental Control | 4-Zone Temperature Control up to 70 °C, CO₂/O₂ Regulation, Anti-Condensation System, Linear & Orbital Shaking |
| Sample Formats | 6–1536-well Microplates, Take3/Take3 Trio Microvolume Plates, Petri Dishes, Cell Culture Dishes |
| Software | Gen5 v3.1+ with LIMS Integration, FDA 21 CFR Part 11 Compliance Support, Audit Trail, Electronic Signatures |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | Take3 |
| Pricing | Upon Request |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-100 |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Measurement Principle | Filter-Based Absorbance Detection |
| Wavelength Range | 400–750 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Linearity | ±1% (0–2.000 Abs), ±2% (2.000–4.000 Abs) |
| Accuracy (405 nm) | ±1% (0–3 Abs), ±2% (3–4 Abs) |
| Precision (CV, 405 nm) | ≤0.2% (0–3 Abs), ≤1.0% (3–4 Abs) |
| Detection Speed | <6 s/96-well (single wavelength), <9 s/96-well (dual wavelength) |
| Optical System | 8-channel high-precision fiber-optic path with automatic well-centering |
| Filter Capacity | 8-position filter wheel (standard filters: 405, 450, 490/492, 630 nm) |
| Display | 7-inch color TFT touchscreen (800 × 480 px) |
| Plate Compatibility | Standard 96-well microplates and strip formats |
| Onboard Storage | 200 protocols + 100,000 assay results (96-well format) |
| Interfaces | 3 × USB (PC, printer, USB drive), Wi-Fi |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Lamp Type | Long-life halogen lamp (≥4000 h) |
| Built-in Diagnostics | Real-time self-check of optical path, mechanical positioning, plate loading, and filter alignment |
| Shaking Function | Adjustable speed and duration |
| Safety Mechanism | Motorized door with obstacle-detection reversal |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-100T |
| Detection Principle | Filter-based photometric absorbance |
| Wavelength Range | 340–750 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Resolution | 0.001 Abs |
| Linearity (R²) | ≥0.995 (0–3.0 Abs) |
| Wavelength Accuracy | ≤±2 nm |
| Absorbance Precision (CV) | ≤0.3% (0–3 Abs), ≤1.0% (3–4 Abs) |
| Absorbance Stability | ≤0.005 Abs (0–3 Abs) |
| Absorbance Accuracy | ±0.005 Abs (0–2 Abs), ±0.01 Abs (2–3 Abs), ±1.5% (3–4 Abs) |
| Measurement Speed | 6 s/96-well (single wavelength, fast mode) |
| Filter Capacity | 8-position wheel (standard 4 filters: 405, 450, 492, 630 nm) |
| Incubation Function | Yes, 25°C to 50°C (RT + 4°C min) |
| Display | 7-inch capacitive touchscreen |
| Data Storage | Internal memory for 1000 protocols & results + USB export |
| Interfaces | 3× USB (host/device), supports printer, PC, and flash drive |
| Power | AC 100–240 V, 50–60 Hz, 2 A |
| Dimensions (W×D×H) | 295 × 440 × 225 mm |
| Weight | 10 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-Mini |
| Light Source | Dual high-stability LED (340–750 nm) |
| Detection Principle | Absorbance (Optical Density) |
| Standard Filters | 450/630 nm & 405/492 nm |
| Custom Filter Options | 340–750 nm (28 wavelengths available) |
| Detector | 9-photodiode array |
| Measurement Range | 0–4.0 Abs |
| Resolution | 0.001 Abs |
| Wavelength Accuracy | ≤ ±2 nm |
| Linearity | R² ≥ 0.995 (0.0–3.0 Abs) |
| Photometric Accuracy | ≤ ±(0.5% + 0.01 Abs) [0.0–2.0 Abs), ≤ ±(1.0% + 0.01 Abs) [2.0–3.0 Abs) |
| Precision (CV) | ≤ 0.5% [0–3.0 Abs) |
| Stability | ≤ 0.005 Abs [0.0–2.0 Abs) |
| Read Time | <15 s (single wavelength), <28 s (dual wavelength) for 96-well plate |
| Dimensions (W×D×H) | 135 × 225 × 89 mm |
| Weight | 2.0 kg |
| Power | USB-powered (12 V, 3 A) |
| Interface | 1 × USB-C, 1 × USB-A |
| Connectivity | Bluetooth 5.0, USB cable |
| Software | Cross-platform PC application (Windows 7/10 64-bit), bilingual UI (English/Chinese) |
| Optional Module | AMR-Mini T with integrated incubation (up to 45 °C) and orbital shaking (200–1,200 rpm) |
| Brand | Allsheng |
|---|---|
| Model | AMR-Mini T |
| Detection Principle | Absorbance (Optical Density) |
| Wavelength Range | 340–750 nm |
| Standard Filters | 450/630 nm & 405/492 nm |
| Optional Filters | 340–750 nm (28 discrete wavelengths available) |
| Light Source | Dual high-stability LED |
| Detector | 9-photodiode array |
| Measurement Modes | Endpoint, Kinetic, Dual-Wavelength |
| Absorbance Range | 0–4.0 Abs |
| Resolution | 0.001 Abs |
| Accuracy | ≤±(0.5% + 0.01 Abs) @ 0.0–2.0 Abs |
| Linearity | R² ≥ 0.995 (0.0–3.0 Abs) |
| Repeatability | CV ≤ 0.5% (0–3.0 Abs) |
| Stability | ≤0.005 Abs (0.0–2.0 Abs) |
| Read Time | <15 s (single-wavelength, 96-well), <28 s (dual-wavelength, 96-well) |
| Incubation Temp Range | RT+4°C to 45°C |
| Dimensions (W×D×H) | 135 × 245 × 91 mm |
| Weight | 2.5 kg |
| Interface | USB-A, USB-C, Bluetooth 5.0 |
| Power | 12 V DC, 3 A |
| Software | Cross-platform PC application (Windows 7/10 64-bit) and mobile app (iOS/Android), bilingual UI (English/Chinese) |
| Compliance | Designed per ISO 15197:2013 and CLSI EP17-A2 guidelines for quantitative absorbance-based immunoassays |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | APW-200 |
| Plate Format | 96-well |
| Residual Volume | ≤1 µL per well |
| Wash Head Options | 8-channel or 12-channel |
| Wash Volume Range | 50–2000 µL (50 µL increments) |
| Wash Cycles | 1–99 |
| Wash Modes | Single-point, dual-point, multi-point |
| Soak & Shake Duration | Up to 99 min 00 sec |
| Number of Wash Solutions | 3 independent channels |
| Fluid Containers | Three 2.5 L wash bottles + one 2.5 L waste bottle |
| Dispense Accuracy | ≤2% @ 300 µL |
| Dispense Precision (CV) | ≤1.5% @ 300 µL |
| Display | 4.3-inch color LCD |
| Onboard Memory | 100 user-programmable protocols |
| Connectivity | USB port for protocol transfer and firmware updates |
| Power Supply | AC 110/240 V, 50/60 Hz |
| Weight | 12 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-A500 |
| Detection Modes | Absorbance, Fluorescence (Top-Read), Chemiluminescence, Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP) |
| Wavelength Range (Abs) | 200–1000 nm, 1 nm step |
| Absorbance Range | 0–4 OD |
| Absorbance Accuracy | ±(1.0% + 0.003 OD) at 450 nm (0.0–2.0 OD) |
| Absorbance Precision | CV < 1.0% or SD < 0.003 OD (96-well, precise mode) |
| Read Time (96-well) | <15 s (fast mode) |
| Luminescence Sensitivity | ≤15 amol/plate (ATP assay) |
| Dynamic Range (Luminescence) | 6 decades |
| Fluorescence Sensitivity | ≤1 pM (FITC in 96-well) |
| TRF Sensitivity | ≤0.05 pM (Eu-labeled conjugate) |
| FP Sensitivity | ≤5 mP (standard assay) |
| Excitation/Emission Filter Capacity | 3 pre-installed dual-filter sets (e.g., EX470/EM525), modular & barcode-readable |
| Incubation | PID-controlled, dual-zone (top/bottom), 25–45 °C ±0.5 °C |
| Display | 10-inch motorized rotatable touchscreen (standalone operation) |
| Software | Onboard analysis suite including endpoint, kinetics, spectral scan, standard curve fitting (4PL/5PL), qualitative/quantitative modules, GLP-compliant audit trail (optional PC software: ReaderLT-I) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-L100 |
| Detection Principle | Chemiluminescence (PMT-based) |
| Detection Limit | 5 amol ATP per well |
| Linear Dynamic Range | 6 logs |
| Well-to-Well Crosstalk | ≤0.005% |
| Wavelength Range | 200–850 nm |
| Plate Formats | 6–384-well microplates |
| Automation Level | Fully Automated (integrated dispensers) |
| Compliance | GLP-ready architecture, audit-trail capable software (ReaderLT-I), supports 21 CFR Part 11-compliant configurations |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-MF200 / Feyond-MF280 |
| Absorbance Range | 190–1000 nm (1 nm step) |
| Absorbance Accuracy | ±(1.0% + 0.003 OD) @ 0.0–2.0 OD |
| Absorbance Precision (CV) | <1.0% (standard mode), <0.5% (high-precision mode) |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability (SD) | ≤0.2 nm |
| Spectral Bandwidth (FWHM) | ≤2.5 nm |
| Optical Density Resolution | 0.0001 OD |
| Linear Range (R²) | ≥0.999 @ 0.0–3.0 OD |
| Stray Light | ≤0.1% @ 220 nm |
| Read Time (96-well plate) | <15 s (A1→H1, fast mode) |
| Fluorescence Detection | Top-read mode, Xenon lamp excitation, PMT detection |
| Standard Filter Sets | 470/525 nm, 523/564 nm, 624/692 nm (up to 8 filter positions) |
| Fluorescence LOD | ≤2 pM (96-well black plate, optimized conditions) |
| Dynamic Range | ≥6 decades |
| Plate Compatibility | 6–384-well standard and micro-volume plates |
| Incubation Temperature Range | RT+4°C to 45°C |
| Temp. Uniformity | ≤1.0°C @ 37°C |
| Temp. Accuracy | ±0.5°C @ 37°C |
| Agitation Modes | Linear, orbital, dual-orbital |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | FlexA-200 |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical System | Grating-based monochromator with 1 nm step resolution |
| Read Range | 0–4.0 OD |
| Bandwidth | <2.5 nm |
| Photometric Accuracy @450 nm | ±(1.0% + 0.003 Abs) for 0–2.0 Abs |
| Photometric Precision @450 nm | CV < 0.5% (precise mode), CV < 1.0% (fast mode) |
| 96-well Plate Read Time | ~8 s (fast), <28 s (precise, endpoint) |
| Temperature Control Range | Ambient +4 °C to 45 °C |
| Temp. Uniformity & Accuracy | ±0.5 °C at 37 °C |
| Detector | Dual silicon photodiodes (sample + reference beam) |
| Display | 10-inch capacitive touchscreen (Android OS) |
| Onboard Storage | 16 GB (≥20,000 assay files) |
| Connectivity | 1× USB-B, 2× USB-A, 1× Ethernet |
| Dimensions (W×D×H) | 300 × 500 × 260 mm |
| Net Weight | 15.5 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | FlexA-200HT |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical System | Grating-based monochromator, dual-beam with reference channel |
| Spectral Resolution | 1 nm step |
| Absorbance Range | 0–4.0 OD |
| Linearity (at 450 nm) | R ≥ 0.999 [0.0–3.0 Abs] |
| Absorbance Accuracy (at 450 nm) | ±(1.0% + 0.003 Abs) [0–2.0 Abs], ±2.0% [2.0–2.5 Abs] |
| Absorbance Precision (CV) | <0.5% (precise mode), <1.0% (fast mode) |
| 96-well Plate Read Time | ~8 s (fast), <28 s (precise, endpoint) |
| Temperature Control Range | Ambient +4 °C to 45 °C |
| Temp. Uniformity & Accuracy | ±0.5 °C at 37 °C |
| Incubation | Integrated plate and cuvette chamber |
| Vibration | Linear, 3-speed adjustable |
| Detector | Dual silicon photodiodes (sample + reference) |
| Bandwidth | <2.5 nm |
| Light Source | Xenon flash lamp (>1×10⁹ flashes lifetime) |
| Display | 10-inch capacitive touchscreen (Android OS) |
| Onboard Storage | 16 GB (≥20,000 assay records) |
| Connectivity | 2× USB-A, 1× USB-B, 1× Ethernet |
| Dimensions (W×D×H) | 300 × 500 × 260 mm |
| Weight | 15.5 kg |
| Brand | ANYAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CYFY-8 (96-well plate compatible) |
| Instrument Type | Fully Automated |
| Functionality | Integrated Auto-Cleaning Cycle |
| Dispensing Range | 1–2000 µL |
| Dispensing Accuracy | ≤1.5% CV at 100 µL (96-well plate) |
| Throughput | 96 samples per cycle |
| Dispensing Modes | Full-plate or user-defined column selection |
| Dispensing Principle | Dual-channel peristaltic pump (8-channel dispensing head) |
| Display | 7-inch color TFT touchscreen |
| Additional Functions | Pre-wet, aspiration-retract, plate shaking, tip return-to-home, waste management via removable waste tray with optional tubing to external waste bottle |
| Liquid Handling Compatibility | Compatible with volatile solvents (e.g., ethanol, acetic acid), high-viscosity fluids, high-salinity buffers (e.g., saturated phosphate), and aggressive reagents (including dilute strong acids/bases) |
| Regulatory Context | Designed for GLP-compliant workflows |
| Brand | ANYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | CYFY-8 |
| Type | Automated Microplate Dispenser |
| Sample Throughput | 96-well plate |
| Dispensing Volume Range | 1–2000 µL (customizable) |
| Dispensing Accuracy | ≤1.5% CV at 100 µL (96-well plate) |
| Minimum Dispense Volume | 5 µL |
| Dispense Speed | Dual-mode (High/Low) |
| Channels | 8 |
| Display | 7-inch color TFT touchscreen |
| Dispense Modes | Full-plate or user-defined column selection |
| Integrated Functions | Auto-rinse, aspirate-back, plate shaking, carriage homing |
| Waste Management | Removable waste tray with optional tubing for centralized waste collection |
| Operating Temperature | −20 °C to 40 °C |
| Relative Humidity | <80% RH |
| Liquid Compatibility | Bottled or drum-contained reagents |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Autobio |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | iWO-960 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head Configuration | 12-channel |
| Rinse Head Design | Integrated Anti-Clogging Mesh Filter |
| Fluid Channels | One wash solution channel + one waste aspiration channel |
| Soak Time Range | 0–10 seconds (adjustable in 1-s increments) |
| Wash Cycles | Manual or programmable auto-mode (1–10 cycles) |
| Residual Volume per Well | ≤1 µL |
| Orbital Shaking Function | Yes, with acoustic-dampened motor and vibration-isolated platform |
| Waste Bottle Capacity | Standard 2 L, with full-level optical sensor and audible/visual alarm |
| Brand | Autobio |
|---|---|
| Model | LUMO |
| Detection Method | Chemiluminescence |
| Detector Type | Imported Photomultiplier Tube (PMT) |
| Luminescence Range | 10⁰–10⁹ RLU |
| Plate Format | 96-well and 48-well microplates |
| Read Time per Well | 0.1–10 s |
| Full 96-Well Plate Read Time | <32 s |
| Sensitivity | 10⁻² mol/plate |
| Precision (CV) | <2% |
| Inter-well Cross-Talk | <5×10⁻⁷ |
| Plate Shaking Modes | 3 programmable patterns (speed & duration adjustable) |
| Power Input | 220 V ± 22 V AC |
| Power Consumption | <32.4 VA |
| Dimensions (L×W×H) | 470 × 335 × 205 mm |
| Weight | 13 kg |
| Safety Compliance | CE-marked, 24 V DC internal supply, ISO 13485 certified |
| Brand | Autobio |
|---|---|
| Model | PHOMO |
| Origin | Henan, China |
| Instrument Type | Multifunctional Automated Microplate Reader |
| Assay Mode | Endpoint |
| Calibration Curve | Linear |
| Detector | Dual-LED Laser-Based Photodiode Array |
| Wavelength Range | 200–1000 nm |
| Absorbance Range | 0–4.5 OD |
| Absorbance Linearity | 0.000–2.000 Abs ±0.01% |
| Measurement Speed | 12 s (single wavelength), 20 s (dual wavelength), 6 s (kinetic single-wavelength) |
| Precision (CV) | <0.5% |
| Repeatability (CV) | ≤0.15% |
| Light Source | Dual-LED Cold Light Source (Lifetime ≥100,000 h) |
| Optical Architecture | RSE (Real-time Spectral Enhancement) Silicon Photodetector Platform |
| Scan Mode | Multi-point per well (up to 9 points) |
| Brand | Azenta (formerly 4titude) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | 4ti-0665 Automated Roll-Film Heat Sealer / XP-A Series Semi-Automatic Sheet-Film Heat Sealer / 59-2000 Heat Sealing Films |
| Automation Level | Fully Automatic (4ti-0665), Semi-Automatic (XP-A) |
| Compliance | ISO-manufactured components, SBS-compliant footprint, SiLA 1.2 compatible (4ti-0665), RS-232 interface (XP-A) |
| Cycle Time | 2–3 seconds per plate |
| Sealing Consistency | ≤±1.5% variation in seal integrity across 5,000 consecutive cycles (4ti-0665) |
| Power Supply | 100–240 V AC, 50/60 Hz |