| Brand | 4titude |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Asia-Pacific Manufactured |
| Model | XP-A_230V |
| Pricing | Available Upon Request |
| Brand | AZENTA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | a4S Fully Automatic Microplate Heat Sealer |
| Pricing | Available Upon Request |
| Brand | Benchmark |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | MultiBlock |
| Function Type | Multi-Block, Gradient-Capable, Touchscreen-Controlled Thermal Cycler |
| Heating/Cooling System | Peltier-based |
| Display | 10-inch Full-Color Adjustable-Tilt Touchscreen |
| Communication Ports | USB 2.0, LAN |
| Temperature Range | 4°C to 99.9°C |
| Max Heating Rate | 7.5°C/sec |
| Max Cooling Rate | 6.0°C/sec |
| Temperature Uniformity | ≤ ±0.2°C at 90°C |
| Temperature Accuracy | ≤ ±0.2°C at 90°C |
| Ramp Rate Adjustment | 0.1–5.0°C/sec |
| Gradient Function | Yes (8-zone independent gradient per block) |
| Gradient Accuracy | ±0.1°C |
| Gradient Range | 30–99.9°C |
| Heated Lid | Yes |
| Lid Temperature Range | 30–112°C |
| Software Features | Password-Protected User Accounts, Protocol Transfer via USB, Audit-Trail-Ready Program Storage, On-Device Protocol Wizard |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | Mithras² LB 943 |
| Function Type | Multimode |
| Automation Level | Semi-Automatic |
| Assay Methods | Endpoint, Kinetic, Long-Term Kinetic, Well-Scanning |
| Curve Fitting | Linear, Non-Linear, Logarithmic |
| Detector Types | PMT (3), Photodiode (1) |
| Wavelength Range | 200–850 nm (standard), up to 1000 nm (optional) |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | <0.1% |
| Wavelength Accuracy | ±1 nm |
| Precision (CV) | <0.3% |
| Luminescence Sensitivity | <2 amol ATP/well (96-well, Glow) |
| Fluorescence Sensitivity | <0.1 fmol Fluorescein/well (96-well) |
| TRF Sensitivity | <2 amol Europium/well (96-well) |
| HTRF® Dynamic Range | >600% ΔF |
| FP Sensitivity | <4 mP |
| AlphaScreen® Detection Limit | <12 ng |
| Crosstalk | <5×10⁻⁶ |
| Excitation Sources | Halogen lamp, Xenon flash lamp, Laser (optional) |
| Monochromator | Dual grating (excitation & emission), bandwidth 4–22 nm adjustable in 1 nm steps, optical density >10⁶ |
| Reading Modes | Top & Bottom Read (all modalities) |
| Plate Formats | 6–1536-well microplates, Petri dishes, Terasaki plates |
| Temperature Control | Ambient +5 °C to 45 °C (optional) |
| Certifications | CE, UL, CSA |
| Power Supply | 110–240 V AC, 50/60 Hz |
| Brand | Berthold |
|---|---|
| Origin | Germany |
| Model | Tristar² S LB 942 |
| Detection Modes | Absorbance, Luminescence, Fluorescence (top/bottom read), Time-Resolved Fluorescence (TRF), Homogeneous Time-Resolved Fluorescence (HTRF®), Fluorescence Polarization (FP), Bioluminescence Resonance Energy Transfer (BRET/BRET²/NanoBRET), Fluorescence Resonance Energy Transfer (FRET) |
| Detector | Low-noise, high-speed single-photon counting PMT and photodiode |
| Absorbance Range | 0–4 OD |
| Absorbance Linearity | <0.1% |
| Wavelength Accuracy | ±1 nm |
| Wavelength Scanning Speed | 0.1 s per data point |
| Absorbance Precision | <0.3% |
| Luminescence Sensitivity | <6 amol ATP/well (96-well, glow assay) |
| Fluorescence Sensitivity | <0.2 fmol fluorescein/well (96-well) |
| TRF Sensitivity | <5 amol europium/well |
| Dynamic Range | >6 decades |
| Well-to-Well Crosstalk | <5×10⁻⁶ |
| Injector Options | Up to 3 programmable injectors (10–100 µL, 1 µL increment) |
| Temperature Control | Ambient +5 °C to 45 °C (optional) with cooled PMT |
| Compatible Plate Formats | 6–384-well microplates, Eppendorf µPlate GO.5, Terasaki plates, Petri dishes |
| Excitation Source | Xenon flash lamp |
| Monochromator | Dual grating (4–22 nm bandwidth, 1 nm increment) for absorbance/fluorescence excitation |
| Filter Capacity | Up to 30 high-transmission (>80%) interference filters (excitation & emission) |
| Software | ICE™ (Instrument Control & Evaluation), compliant with 21 CFR Part 11 audit trail and electronic signature requirements |
| Certifications | CE, RoHS, ISO 13485–aligned design |
| Operating Environment | 15–35 °C, 10–85% RH (non-condensing) |
| Storage | 0–40 °C |
| Power Supply | 110–240 V AC, 50/60 Hz |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Model | Easywash |
| Display | 10-inch capacitive touchscreen (1280 × 800) |
| Wash Head Options | Interchangeable 8-channel or 12-channel single/dual-row heads |
| Aspiration/Dispense Speed | 9 adjustable levels |
| Data Storage | Internal 4 GB flash memory (≥20,000 protocol & run records) |
| Automation Interface | RS-232, USB Device/Host, optional Ethernet |
| Compliance Features | Liquid-level sensing, plate-position detection, leak detection, dual independent peristaltic pumps with pressure monitoring |
| Software | Embedded GUI with bilingual (English/Chinese) support, folder-based protocol organization, USB firmware update & data export capability |
| Residual Volume | ≤2 µL/well (96-well plate, standard wash cycle) |
| Compatibility | ANSI/SLAS-format microplates (96-, 384-well), PCR plates, deep-well plates |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | K3 Plus Microplate Reader |
| Detection Method | Absorbance (Optical Density) |
| Function Type | Single-Mode Absorbance Reader |
| Wavelength Range | 400–750 nm |
| Absorbance Linearity | 0–3.0 A at 450 nm (r² ≥ 0.995) |
| Accuracy | ±0.007 Abs (0–0.3 A) |
| Brand | BIO-DL |
|---|---|
| Origin | Shanghai, China |
| Model | K3 Pro Microplate Reader |
| Detection Wavelength Range | 330–900 nm |
| Filter Capacity | Up to 8 interchangeable optical filters |
| Read Time (96-well plate) | 8 s (step mode) |
| Incubation Temperature Range | Room temperature +4 °C to 55 °C |
| Shaking Speed | 3 adjustable levels |
| Absorbance Range | 0–6.0 OD |
| Display | 10-inch capacitive touchscreen |
| Detection Modes | Single-wavelength, dual-wavelength, kinetic, endpoint, multi-wavelength, dual-time point |
| Connectivity | USB, Ethernet, Wi-Fi |
| Software | BIO-DL Microplate Analysis Suite (v3.2+) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Bio-Plex Pro |
| Instrument Type | Dedicated Microplate Washer |
| Wash Head Configuration | 8-channel |
| Rinse Needle Design | Single-needle per channel |
| Wash Fluid Channels | 8 independent wash fluid channels |
| Waste Aspiration Channels | 8 independent waste aspiration channels |
| Soak Time | Programmable, dynamic control |
| Wash Cycles | Programmable, dynamic control |
| Residual Volume per Well | <4 µL |
| Orbital Shaking Function | Yes |
| Plate Carrier | Integrated magnetic plate carrier for xMAP®-based assays (including MagPlex®) |
| Brand | BioTek |
|---|---|
| Origin | USA |
| Model | Epoch |
| Wavelength Range | 200–999 nm (1 nm increments) |
| Optical Path Correction | Automatic |
| Detection Modes | Endpoint, Kinetic, Spectral Scan, Well-Scan |
| Compatible Plates | 6-, 12-, 24-, 48-, 96-, 384-well + Take3 Multi-Volume Plate |
| OD Range | 0–4.0 |
| OD Resolution | 0.0001 |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| OD Accuracy | ±1% ±0.01 OD (0–2 OD), ±3% ±0.01 OD (2–2.5 OD) |
| OD Linearity & Reproducibility | ±1% ±0.005 OD (0–2 OD), ±3% ±0.005 OD (2–2.5 OD) |
| Read Times | 49 sec (96-well normal), 38 sec (96-well fast), 15 sec (96-well scan) |
| Dimensions | 30.5 × 31.7 × 19.5 cm |
| Weight | 6.35 kg |
| Brand | BioTek |
|---|---|
| Origin | USA |
| Model | Synergy H1 |
| Detection Modes | Absorbance, Fluorescence Intensity (Top/Bottom), Luminescence, Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP), TR-FRET, BRET |
| Wavelength Range | Monochromator: 230–999 nm (1 nm step) |
| Filter-based | 200–700 nm (850 nm optional) |
| Absorbance Range | 0.000–4.000 OD |
| Absorbance Linearity | <1% deviation (0–3.0 OD) |
| Read Speed | 96-well: 11 sec |
| 384-well | 22 sec |
| OD Resolution | 0.0001 OD |
| Fluorescence Sensitivity (Filter) | 1 pM fluorescein (0.1 fmol/well, 384-well) |
| Luminescence Sensitivity (Filter) | 10 amol ATP (flash assay) |
| Temperature Control | Ambient to 45 °C (±0.5 °C at 37 °C) |
| CO₂/O₂ Gas Control | Optional integrated module |
| Microplate Compatibility | 1–384-well plates + Take3™ micro-volume plates (2 µL) |
| Software | Gen5® v3.x with FDA 21 CFR Part 11 compliance modules, audit trail, and electronic signature support |
| Regulatory | CE, TÜV certified |
| Brand | BioTek |
|---|---|
| Origin | USA |
| Model | Synergy HT |
| Detection Modes | Absorbance, Fluorescence Intensity, Time-Resolved Fluorescence, Luminescence |
| Wavelength Range (Abs) | 200–999 nm (1 nm increment) |
| Wavelength Range (Fluor) | 200–700 nm (optional to 900 nm) |
| Temperature Control | 4–50 °C |
| Plate Formats | 6–384-well, PCR plates, Take3™ micro-volume plates (2 µL samples) |
| Shaking | Yes |
| Software | Gen5™ |
| Automation-Compatible | Yes |
| Dispenser | Dual syringe pumps (5–1000 µL, 1 µL increment) |
| Dimensions | 40.6 × 38 × 25.4 cm |
| Weight | 18 kg |
| Brand | BMG LABTECH |
|---|---|
| Origin | Germany |
| Model | Micro-GCM omega |
| Detection Modes | Absorbance (220–1000 nm), Fluorescence (up to 8 channels), Luminescence |
| Temperature Control | Ambient +4 °C to 45 °C (optional up to 65 °C), ±0.1 °C accuracy, sandwich dual-zone heating |
| Humidity Control | Compatible with specialized breathable, anti-evaporation microplate sealing films |
| Gas Control | Atmospheric Control Unit (ACU) for independent or coupled regulation of O₂ (0.1–20%) and CO₂ (0.1–20%) |
| Shaking | Linear, orbital, or dual-orbital |
| Detection Speed | <1 second per well for full-spectrum absorbance (220–1000 nm) |
| Plate Formats | 6–384-well microplates |
| Software | Preconfigured assay templates, kinetic data acquisition, GLP-compliant audit trail, EC₅₀/IC₅₀ fitting, 4-parameter logistic regression, standard curve generation |
| Automation | Dual high-precision injectors (min. 3 µL injection volume, dead volume <30 µL, up to 4 injections/well with simultaneous read) |
| Brand | Chuanhong |
|---|---|
| Origin | Shanghai, China |
| Model | CHFY-96 |
| Instrument Type | Automatic |
| Dispensing Principle | Peristaltic Pump |
| Dispensing Method | Peristaltic Pump |
| Plate Compatibility | 96-well, 384-well, PCR plates, skirted/unskirted microplates, tubes (1.5–15 mL), vials, glass bottles, cuvettes |
| Plate Height Adjustment | Motorized Auto-Adjustment |
| Dispensing Range | 100 µL per well (96-well plate) |
| throughput | 240 plates/hour |
| Dispensing Accuracy | ≤ ±1.5% at 100 µL |
| Liquid Handling Features | Aspirate-reverse dispensing, on-board pre-wash reservoir, programmable row/column/well-specific dispensing, three-speed dispensing modes, auto-cleaning cycle, tube sterilization compatibility (50× autoclave cycles) |
| User Interface | Color TFT touchscreen with Chinese/English bilingual OS |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 360 × 320 × 380 mm |
| Weight | 12.5 kg |
| Regulatory Compliance | Designed for GLP-compliant labs |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | CHZDFY-8 |
| Dispensing Range | 1–2000 µL |
| Dispensing Accuracy | ≤1.5% CV at 100 µL (96-well plate) |
| Throughput | 96-well microplates |
| Dispensing Modes | Full-plate or user-defined column selection |
| Dispensing Principle | Peristaltic pump-based non-contact delivery |
| Plate Height Adjustment | Motorized auto-adjustment |
| Channel Configuration | 8-channel parallel dispensing |
| Display | 7-inch color TFT touchscreen interface |
| Integrated Functions | Plate shaking, pre-wetting, liquid retraction, carriage homing, and automated waste aspiration |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W×D×H) | 320 × 420 × 380 mm |
| Weight | 18.5 kg |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured) |
| Model | CloneSelect Imager FL |
| Pricing | Available Upon Request |
| Brand | Corning |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 6575 Universal Clear PCR Sealing Tape |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HT200 |
| Pricing | Upon Request |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | MD-8 / MD-12 |
| Instrument Type | Automated Microplate Dispenser |
| Dispensing Principle | Peristaltic Pump |
| Dispensing Accuracy | ≤±3% for 10–20 µL |
| Sample Throughput | 96-well plate compatibility |
| Dispensing Flexibility | Column-selectable dispensing (any column(s) in 96-well format) |
| Dispensing Range | 5 µL to 10 mL per well (with interchangeable dispensing manifolds) |
| Dispensing Height Adjustment | 5–85 mm |
| User Interface | 7-inch high-resolution capacitive touchscreen |
| Onboard Program Storage | Up to 100 user-defined protocols |
| Preloaded Assay Protocols | Coagulation assay & ELISA workflows |
| Residual Liquid Aspiration | Integrated post-dispense aspiration to minimize carryover and cross-contamination |
| Cleaning & Mixing Functions | Built-in tube rinse cycle and plate shaking (orbital mixing) |
| Dispensing Manifold | Sterilizable, removable, autoclavable (121°C, 20 min) |
| Dispense Speed | 5 adjustable speed levels |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | DHS |
|---|---|
| Model | PCR-Sealer |
| Origin | Beijing, China |
| Type | Manual Benchtop Heat Sealer |
| Sealing Temperature Range | 5°C above ambient to 200°C (±1°C accuracy) |
| Sealing Time | 1–9 s (0.5 s increments) |
| Dimensions | 300 × 200 × 300 mm |
| Weight | 9.5 kg |
| Compatible Plates | Standard 96-well PCR plates, ELISA microplates, deep-well plates |
| Compatible Films | Standard thermal sealing films, pierceable films, optical-grade films (qPCR), permanent adhesive films |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | PCR-Sealer Plus |
| Automation Level | Manual |
| Sealing Temperature Range | 5–200 °C |
| Sealing Time | 1–9 s |
| Input Power | 220 V / 50 Hz |
| Dimensions (W×D×H) | 230 × 395 × 310 mm |
| Weight | 9.5 kg |
| Compatible Plate Types | Standard 96-well PCR plates, 384-well amplification plates, microtiter plates (ELISA), deep-well plates |
| Sealant Compatibility | Universal thermal sealing films including standard heat-seal films, pierceable films, optical films (for qPCR), and permanent adhesive films |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | PCR-Sealer Plus |
| Automation Level | Manual |
| Sealing Temperature Range | Ambient +5 °C to 200 °C |
| Temperature Accuracy | ±0.1 °C |
| Sealing Time | 1–9 s |
| Maximum Plate Height | 85 mm |
| Max Input Power | 300 W |
| Dimensions (W×D×H) | 230 × 395 × 310 mm |
| Weight | 11 kg |
| Brand | Dynamica |
|---|---|
| Model | HALO MPR-96 |
| Origin | Switzerland |
| Wavelength Range | 400–750 nm (MPR-96UV: 340–750 nm) |
| Absorbance Range | 0–4.0 OD |
| Resolution | 0.001 OD |
| Stability | ±0.001 OD (after 15 min warm-up) |
| Accuracy | ±1.0% ±0.01 OD (405 nm, 0.000–2.500 OD) |
| Repeatability | ±0.5% ±0.005 OD (405 nm, 0.000–2.500 OD) |
| Linearity | ±1.0% (405 nm, 0.000–2.500 OD) |
| Filter Positions | 5 (4 fixed + 1 user-selectable, 400–750 nm) |
| Read Time | ≤10 s (single wavelength, 96-well) |
| Plate Formats | 96-well flat, U-bottom, V-bottom |
| Optical Channels | 8 measurement + 1 reference |
| Detector | Silicon photodiode |
| Light Source | Tungsten-halogen lamp |
| Display | Backlit LCD, 320×240 px |
| Incubation (optional) | Ambient +4°C to +50°C, ±0.5°C accuracy |
| Dimensions (W×D×H) | 290×425×200 mm |
| Weight | 15 kg (net), 20 kg (gross) |
| Power | 110–220 V auto-switching, 50/60 Hz, 50 W (standby), 100 W (operational) |
| Brand | ProteinSimple |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Ella |
| Detection Method | Fluorescence Intensity |
| Automation Level | Fully Automated Microplate-Based Immunoassay Platform |
| Assay Format | Fully Automated Microfluidic ELISA |
| Standard Curve Handling | On-instrument, No Manual Standard Curve Generation Required |
| Brand | Evergreen |
|---|---|
| Origin | Germany |
| Model | 00000 |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Detection Method | Absorbance (Photometric) |
| Wavelength Range | 300–750 nm |
| Absorbance Range | 0–4.0 OD |
| Linearity | ±2.5% or ±0.010 OD (whichever is greater) |
| Wavelength Scanning Speed | 400–750 nm |
| Accuracy | ±0.010 OD (0–4.0 OD range) |
| Detection System | 8-Channel Fiber-Optic Array |
| Measurement Time | ≤5 s per 96-well plate |
| Plate Compatibility | Standard 96-well microplates (flat, round, or V-bottom) |
| Software Interface | Windows-based GUI with touch-screen support |
| Data Storage | ≥10,000 assay results and ≥100 user-defined protocols |
| Compliance | Designed for ISO 13485-aligned workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LumiStation 1800 |
| Functionality | Dedicated Chemiluminescence Detection |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Curve Fitting | Linear Regression |
| Detector | Photon-Counting Photomultiplier Tube (PMT) |
| Wavelength Range | 300–650 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Absorbance Linearity | 0.000–2.000 Abs |
| Single-Wavelength Kinetic Read Time | 6 sec per well |
| Sensitivity | 7 amol ATP per well |
| Plate Formats | 96-well and 384-well microplates |
| Incubation Range | Ambient +2 °C to 65 °C |
| Shaking Modes | Linear, Orbital, Cross |
| Integration Time | User-Configurable |
| Software Interface | USB-Controlled Data Acquisition & Analysis Workstation |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LumiStation 1800Plus |
| Price Range | USD 7,000–14,000 |
| Function Type | Dedicated Chemiluminescence Detection |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Dual-Read, Kinetic |
| Curve Fitting | Linear Regression |
| Detector | Photon-Counting Photomultiplier Tube (PMT) |
| Wavelength Range | 300–650 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Absorbance Linearity | 0.000–2.000 Abs |
| Single-Wavelength Kinetic Read Time | 6 sec |
| Sensitivity | 7 amol ATP per well |
| Microplate Formats | 96-well & 384-well |
| Incubation Range | Ambient +2 °C to 65 °C |
| Shaking Modes | Linear, Orbital, Cross |
| Data Interface | USB 2.0 |
| Software Compliance | FDA 21 CFR Part 11, GLP/GMP Audit Trail, IQ/OQ/PQ Ready |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 1000F |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 190–1000 nm |
| Absorbance Range | 0–6 Abs |
| Linearity Range | 0–3 Abs (±2%) |
| Wavelength Measurement Speed | 6 s per 96-well plate (fast mode) |
| Precision | CV ≤ 0.2% (0–3 Abs) |
| Detector Type | Photodiode |
| Filter Capacity | Up to 16 positions (standard: 405, 450, 620 nm) |
| Plate Format | Standard 96-well microplates |
| Resolution | 0.001 Abs |
| Incubation Option | Optional heated incubator module (MF-10) |
| Control Interface | 7-inch capacitive touchscreen |
| Data Storage | 100 protocols + 100 × 96-well datasets |
| Connectivity | 3× USB (PC, USB drive, printer) |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 1500 |
| Detection Principle | Monochromator-based UV-Vis Absorbance |
| Wavelength Range | 190–1000 nm (1 nm step) |
| Optical Density Range | 0–4.000 OD |
| OD Linearity | ±0.01% in 0–2.0 OD |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Spectral Bandwidth | 2.5 nm (2–10 nm customizable) |
| Stray Light | <0.01% (@230 nm) |
| OD Precision | CV <0.5% (@450 nm) |
| Read Time | 20 s per 96-well plate (dual-wavelength) |
| Plate Format | Standard and UV-transparent 96-well microplates |
| Detector Type | UV-Vis photodiode array |
| Light Source | Xenon flash lamp |
| Interface | 7-inch capacitive touchscreen + USB data export |
| Software | Onboard firmware with kinetic, endpoint, spectral scan, and curve-fitting modes (linear, point-to-point) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Flash Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | ReadMax 1900 |
| Detection Principle | Absorbance (Photometric) |
| Wavelength Range | 190–900 nm |
| Optical Density Range | 0–4.000 OD |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | <0.2 nm |
| Spectral Bandwidth | 2–10 nm (customizable) |
| Incubation Temperature Range | Ambient to 45 °C |
| Plate Formats | Standard 96-well and UV-transparent 96-well microplates |
| Detection Modes | Single-, Dual-, and Multi-wavelength |
| Data Interface | USB 2.0 |
| Software Compliance | FDA 21 CFR Part 11, IQ/OQ/PQ protocols, GLP/GMP-ready |
| Optional Accessories | Dual-cuvette adapter plate (NA-10), incubation-shaking module (MF-10), multi-mode washer (MX-10), LIMS server (WS-10) |