| Brand | AQUAREAD |
|---|---|
| Origin | United Kingdom |
| Model | AP |
| Detection Principle | In-situ Fluorescence Excitation/Emission (685 nm excitation, 730 nm emission) |
| Chlorophyll a Range | 0–500 µg/L |
| Resolution | 0.1 µg/L |
| Accuracy | ±2% of reading |
| Turbidity Range | 0–3000 NTU (dual-range auto-scaling) |
| Dissolved Oxygen | 0–50.00 mg/L |
| Algal Pigment Channels | Chlorophyll a, Phycocyanin, Phycoerythrin |
| Fluorescent Tracer Detection | Rhodamine WT, Oil-in-Water (254 nm UV LED excitation) |
| Data Storage | 1900 samples |
| GPS | Built-in 12-channel, ±10 m accuracy |
| Display | Backlit 80-character LCD |
| Dimensions (W×H×D) | 90 × 180 × 39 mm |
| Weight (with batteries) | 450 g |
| Power | 5×AA alkaline or Ni-MH rechargeable |
| Battery Life | >20 h (alkaline), >40 h (Ni-MH) |
| Operating Temperature | −20 to +70 °C |
| Enclosure Rating | IP67 |
| Interface | USB |
| Barometric Pressure Sensor | 150–1150 mbar (±1 mbar) |
| Brand | AQUAREAD |
|---|---|
| Origin | United Kingdom |
| Model | AquaPlus |
| Instrument Type | Portable |
| Measurement Principle | Optical Fluorescence Quenching |
| DO Range | 0–500.0% saturation / 0–50.00 mg/L |
| Accuracy | ±1% of reading (0–200% / 0–20 mg/L), ±10% of reading (200–500% / 20–50 mg/L) |
| Repeatability | ±0.05% |
| Detection Limit | ±2 ppb (O₂) |
| Temperature Range | −5 °C to +50 °C |
| Conductivity Range | 0–200 mS/cm (auto-ranging across three scales) |
| Salinity Range | 0–70.00 PSU |
| GPS | Integrated receiver with latitude, longitude, and ellipsoidal height output |
| Barometric Pressure Sensor | Built-in |
| IP Rating | IP67 |
| Display | High-contrast, sunlight-readable LCD |
| Brand | Aquaread |
|---|---|
| Origin | Germany |
| Model | MV2215L |
| Housing Material | ABS |
| IP Rating | IP41 |
| Dimensions (L×W×H) | 190 × 130 × 100 mm |
| Operating Temperature | −10 to +50 °C |
| Power Supply | 12–24 V AC/DC |
| Communication Interface | RS-232 |
| Sensor Connectors | Dual 4 mm banana/BNC |
| Temperature Sensor | Integrated Pt1000 with automatic temperature compensation |
| Base Configuration | Three smart electrochemical modules |
| Expandable to | Up to 16 LM2000 modules via modular bus architecture |
| Software Features | Automatic module recognition, calibration management, real-time temperature compensation, self-diagnosis, GLP-compliant data logging, calculation engine, data export |
| Brand | Aquaread |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AP-7000-SDI2 |
| Pricing | Upon Request |
| Brand | AQUAREAD |
|---|---|
| Origin | United Kingdom |
| Model | AquaLab |
| Measurement Principle | Luminescence-based (Optical) DO Sensing |
| Range | 0–500.0% saturation / 0–50.00 mg/L |
| Resolution | 0.1% / 0.01 mg/L |
| Accuracy | ±1% of reading (0–200%), ±10% of reading (200–500%) |
| Sensor Dimensions | 12 mm × 150 mm |
| Display Unit Dimensions | 90 mm × 180 mm × 39 mm |
| Power Supply | 5 × AA alkaline batteries |
| Battery Life | >55 hours |
| Data Storage Capacity | 3,000 readings |
| Display | Backlit FSTN LCD |
| Barometric Pressure Range | 150–1150 mbar (±1 mbar accuracy) |
| Compensation | Automatic temperature, pressure, and salinity compensation |
| Sensor Maintenance | Replaceable optical sensor cap |
| Compliance | GLP-compliant calibration logging |
| Software Interface | OxiLink PC software for data export, audit trail, and report generation |
| Brand | AQUAREAD |
|---|---|
| Origin | United Kingdom |
| Model | AP-LITE-BGAPE |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Sensor Principle | In-situ Phycocyanin Fluorescence Detection |
| Measurement Range | 0–200,000 cells/mL |
| Resolution | 1 cell/mL |
| Repeatability | ±2% of reading |
| Probe Dimensions | Ø24 mm × 250 mm |
| Aquameter Dimensions | 90 × 180 × 39 mm |
| Aquameter Weight (with batteries) | 450 g |
| Display | Backlit 80-character LCD |
| Data Storage | 1900 samples |
| GPS | Built-in 12-channel antenna, accuracy ±10 m |
| Barometric Pressure Range | 150–1150 mbar (±1 mbar) |
| Power Supply | 5× AA alkaline or Ni-MH rechargeable batteries |
| Operating Temperature | −20 to +70 °C |
| Enclosure Rating | IP67 |
| Interchangeable Sensor Platform | Yes (supports turbidity, chlorophyll-a, phycocyanin, phycoerythrin, rhodamine WT, hydrocarbons, CDOM) |
| Brand | Aquaread |
|---|---|
| Origin | United Kingdom |
| Model | AP-2000-AM |
| Instrument Type | Portable/Handheld Multi-Parameter Water Quality Analyzer |
| Dimensions (W×H×D) | 90×180×39 mm |
| Weight (incl. battery) | 450 g |
| Display | Backlit 80-character LCD |
| Memory Capacity | 1,900 data points |
| GPS | Built-in 12-channel antenna, ±10 m accuracy |
| Barometric Pressure Range | 150–1,150 mbar (±1 mbar) |
| Interface | RS-485/RS-232 |
| Power Supply | Replaceable internal battery |
| Operating Temperature | −20 to +70 °C |
| IP Rating | IP67 |
| DO | 0–500 % / 0–50.00 mg/L (res: 0.1 % / 0.01 mg/L |
| acc | ±0.01 mg/L) |
| Conductivity | 0–200 mS/cm (res: 0.1 µS/cm |
| acc | ±0.5 % of reading) |
| TDS | 0–100,000 mg/L (two auto-ranging scales |
| acc | ±1 % of reading or ±0.1 unit, whichever is greater) |
| Resistivity | 5 Ω·cm – 1 MΩ·cm (two auto-ranging scales |
| acc | ±1 % of reading or ±0.1 unit) |
| Salinity | 0–70 PSU (res: 0.01 PSU |
| acc | ±1 % of reading or ±0.1 unit) |
| Seawater Density (σt) | 0–50 σt (res: 0.1 σt |
| acc | ±1.0 σt) |
| ORP | ±2000 mV (res: 0.1 mV |
| acc | ±0.5 mV) |
| Depth | 0–30 m (res: 0.01 m |
| acc | ±0.1 m) |
| Temperature | −5 to +50 °C (res: 0.1 °C |
| acc | ±0.5 °C) |
| pH | 0–14 pH (res: 0.01 pH |
| acc | ±0.01 pH) |
| Ammonium (NH₄⁺/NH₃-N) | 0–1,000 mg/L as N (two auto-ranging scales |
| acc | ±10 %) |
| Brand | AQUAREAD |
|---|---|
| Origin | United Kingdom |
| Model | AP-2000-NH |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Sensor Measurement Range | 0–1,000 mg/L NO₃⁻ (as N or as NO₃, context-dependent) |
| Resolution | 0.01 mg/L (0–99.99 mg/L), 0.1 mg/L (100.0–999.9 mg/L) |
| Accuracy | ±10% of reading |
| Sensor Housing Dimensions | Ø24 mm × 250 mm |
| Aquameter Display Unit Dimensions | 90 × 180 × 39 mm |
| Aquameter Weight (with batteries) | 450 g |
| Display | Backlit 80-character LCD |
| Data Storage Capacity | 1,900 measurements |
| Integrated GPS | 12-channel receiver, ±10 m horizontal accuracy |
| Barometric Pressure Sensor Range | 150–1,150 mbar, resolution ±1 mbar |
| Power Supply | 5 × AA alkaline or Ni-MH rechargeable batteries |
| Operating Temperature | −20 °C to +70 °C |
| Enclosure Rating | IP67 |
| Brand | AQUAREAD |
|---|---|
| Country of Origin | United Kingdom |
| Model | AP7000SDI |
| Instrument Type | Online Multi-Parameter Water Quality Analyzer |
| Sensor Capacity | Up to 12 sensors (6 standard + 6 expandable ISE/optical ports) |
| Power | Rechargeable internal battery (7-day continuous operation) |
| Data Storage | 8 GB embedded memory |
| Connectivity | SDI-12, RS-232, USB, Bluetooth, GSM/GPRS for remote alerts |
| IP Rating | IP68 (1 m submersion for 30 min) |
| Housing Material | Marine-grade aluminum alloy |
| GPS Integration | Built-in (via Aquameter handheld controller) |
| Compliance | Designed for ASTM D3370, ISO 5667, US EPA Method 160.1, and GLP-compliant data logging |
| Brand | AQUAREAD |
|---|---|
| Origin | United Kingdom |
| Model | AP-800 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Sensor IP Rating | IP68 |
| Aquameter Display Unit IP Rating | IP67 |
| Cable Length | 3 m |
| Key Measured Parameters | pH, ORP, Electrical Conductivity (EC), Dissolved Oxygen (DO), Temperature, Turbidity (AP-800 only) |
| Brand | Aquaread |
|---|---|
| Origin | United Kingdom |
| Model | APLITE |
| Detection Principle | In-situ Pulsed LED-Induced Fluorescence |
| Measurement Range (Chlorophyll-a) | 0–500 µg/L |
| Resolution | 0.1 µg/L |
| Accuracy | ±2% of reading |
| Probe Interface | Modular optical sensor bay |
| Data Storage | 1900 records |
| GPS | Built-in 12-channel, ±10 m accuracy |
| Display | Backlit 80-character LCD |
| Dimensions (W×H×D) | 90×180×39 mm |
| Weight (with batteries) | 450 g |
| Power | 5×AA alkaline or Ni-MH rechargeable |
| Battery Life | >20 h (alkaline), >40 h (Ni-MH) |
| Operating Temperature | −20 to +70 °C |
| Enclosure Rating | IP67 |
| Barometric Pressure Sensor | 150–1150 mbar (±1 mbar) |
| Connectivity | USB |
| Brand | AQUAREAD |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AP-LITE |
| Application | Field-deployable chlorophyll a quantification in freshwater and marine environments |
| Sensor Compatibility | Interchangeable optical modules (turbidity, phycocyanin, phycoerythrin, rhodamine WT, hydrocarbon fluorescence) |
| Readout Unit | Aquameter Data Logger |
| Chlorophyll a Range | 0–500 µg/L |
| Resolution | 0.1 µg/L |
| Repeatability | ±2% of reading |
| Sensor Housing Diameter | 24 mm |
| Sensor Housing Length | 250 mm |
| Aquameter Dimensions (W×H×D) | 90 × 180 × 39 mm |
| Aquameter Weight (with batteries) | 450 g |
| Display | Backlit 80-character LCD |
| Memory Capacity | 1900 data points |
| GPS | Integrated 12-channel receiver, positional accuracy ±10 m |
| Barometric Pressure Range | 150–1150 mbar, accuracy ±1 mbar |
| Power Supply | 5 × AA alkaline or Ni-MH rechargeable batteries |
| Operating Temperature | −20 to +70 °C |
| Ingress Protection | IP67 |
| Brand | AQUAREAD |
|---|---|
| Origin | United Kingdom |
| Model | AP-LITE-BGAPE1 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Sensor Principle | Allophycocyanin (APC)-Specific Fluorescence Detection |
| Measurement Range | 0–200,000 cells/mL |
| Resolution | 1 cell/mL |
| Repeatability | ±2% of reading |
| Sensor Housing Dimensions | Ø24 mm × 250 mm |
| Aquameter Display Unit | 90 × 180 × 39 mm, 450 g (with batteries), Backlit 80-character LCD, 1900-data memory, Built-in 12-channel GPS (±10 m accuracy), Barometric Pressure Sensor (150–1150 mbar, ±1 mbar), IP67-rated, Operating Temperature: −20 to +70 °C |
| Power | 5×AA alkaline or Ni-MH rechargeable batteries |
| Interchangeable Sensor Platform | Supports APC, Chlorophyll-a, Phycocyanin (PC), Turbidity, Rhodamine WT, CDOM, and Hydrocarbon optical sensors |
| Brand | Aquaread |
|---|---|
| Origin | United Kingdom |
| Model | AP-800(2) |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Enclosure Rating | IP68 (sensor), IP67 (Aquameter display unit) |
| Construction | Marine-grade anodized aluminum housing |
| Cable Length | 3 m (replaceable) |
| Measured Parameters | pH, ORP, Conductivity, Dissolved Oxygen (DO), Temperature, Turbidity (AP-800 only) |
| Compliance | CE, RoHS, UKCA |
| Software | AquaLink v5.x (Windows/macOS) with GLP-compliant data logging and audit trail |
| Brand | Aquaread |
|---|---|
| Origin | United Kingdom |
| Model | AP-2000 |
| Instrument Type | Portable |
| Certifications | CE, RoHS, IP67-rated housing |
| Compliance | Designed for ASTM D3370, ISO 5667-3, and EPA Method 353.2–compatible field deployment |
| Brand | Aquaread |
|---|---|
| Origin | United Kingdom |
| Model | AP-7000 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| GPS Accuracy | ±10 m |
| Operating Temperature | -20 to +70 °C |
| Protection Rating | IP67 |
| Display | Backlit 80-character LCD |
| Data Storage | 1900 measurements |
| Power Supply | Replaceable internal batteries |
| Communication Interface | RS-485/RS-232 |
| Barometric Pressure Range | 150–1150 mbar (±1 mbar) |
| Dissolved Oxygen | 0–500 % saturation / 0–50.00 mg/L (±0.01 mg/L) |
| Conductivity | 0–200 mS/cm (±0.5 % of reading) |
| TDS | 0–100,000 mg/L (±1 % of reading or ±0.1 unit, whichever is greater) |
| Resistivity | 5 Ω·cm – 1 MΩ·cm (±1 % of reading or ±0.1 unit, whichever is greater) |
| Salinity | 0–70 PSU (±1 % of reading or ±0.1 PSU, whichever is greater) |
| Seawater Density (σt) | 0–50 σt (±1.0 σt) |
| ORP | ±2000 mV (±0.5 mV) |
| Depth | 0–30 m (±0.1 m) |
| Temperature | -5 to +50 °C (±0.5 °C) |
| pH | 0–14 pH (±0.01 pH) |
| Optional ISE Sensors | Ammonium, Nitrate, Chloride, Fluoride, Calcium (0–1000 mg/L, ±10 %) |
| Optional Optical Sensors | Chlorophyll-a, Phycocyanin (freshwater/marine), Rhodamine WT, Fluorescein, Hydrocarbon Oil, Turbidity (0–3000 NTU, ±2 %) |
| Brand | AQUAREAD |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aqua-Plus |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Quenching |
| Measurement Range | 0–80 mg/L (or % saturation) |
| Accuracy | ±0.1 mg/L |
| Repeatability | ±0.05% of reading |
| Detection Limit | 2 ppb (O₂) |
| Brand | Aquaread |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AP-LITE-TURB |
| Price | Upon Request |
| Display | Backlit 80-character LCD |
| Memory Capacity | 1900 data points |
| GPS | Built-in 12-channel antenna, ±10 m accuracy |
| Barometric Pressure Range | 150–1150 mbar (±1 mbar) |
| Operating Temperature | -20 to +70 °C |
| IP Rating | IP67 |
| Dimensions (Meter) | 90 × 180 × 39 mm |
| Weight (with batteries) | 450 g |
| Power Supply | 5 × AA alkaline or Ni-MH rechargeable batteries |
| Sensor Housing Diameter | 24 mm |
| Sensor Housing Length | 250 mm |
| Turbidity Measurement Range | 0–3000 NTU |
| Resolution | Dual auto-ranging: 0.0–99.9 NTU (0.1 NTU resolution), 100–3000 NTU (1 NTU resolution) |
| Repeatability | ±2% of reading |
| Brand | AQUAREAD |
|---|---|
| Origin | United Kingdom |
| Model | AP7000-2 |
| Instrument Type | Online Multi-Parameter Water Quality Analyzer |
| Sensor Capacity | Up to 12 sensors (6 standard + 6 expandable ISE/optical interfaces) |
| Power | Rechargeable internal battery (7-day continuous operation) |
| Data Storage | 8 GB embedded memory |
| Communication | USB, RS-232, SDI-12, GSM/GPRS for SMS alerts |
| IP Rating | IP68 (1 m submersion, 30 min) |
| Housing Material | Marine-grade aluminum alloy |
| GPS Integration | Yes (via Aquameter handheld controller) |
| Compliance | Designed for ASTM D1129, ISO 5667, US EPA 40 CFR Part 136, and GLP-compliant data logging |
| Brand | Aquaread |
|---|---|
| Origin | United Kingdom |
| Model | AP-800 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Enclosure Rating | IP68 (sensor), IP67 (Aquameter display unit) |
| Construction | Marine-grade anodized aluminum housing |
| Sensor Parameters | pH, ORP, Electrical Conductivity (EC), Dissolved Oxygen (DO), Temperature, Turbidity (optional probe) |
| Derived Parameters | Total Dissolved Solids (TDS), Salinity, Specific Conductance, Resistivity (calculated from EC and temperature) |
| Compliance | CE, RoHS, UKCA |
| Software | AquaLink v5.x (Windows/macOS compatible, supports GLP-compliant data export) |
| Brand | AQUAREAD |
|---|---|
| Origin | United Kingdom |
| Model | AP-CPHYLL |
| Portability | Handheld Submersible Design |
| Measurement Principle | In-situ Pulse-Amplitude Modulated (PAM) Fluorescence |
| Chlorophyll-a Range | 0–500 µg/L |
| Resolution | 0.1 µg/L |
| Repeatability | ±2% of reading |
| Sensor Housing Diameter | 24 mm |
| Sensor Housing Length | 250 mm |
| Aquameter Display | Backlit 80-character LCD |
| Aquameter Memory | 1900 data points |
| GPS | Built-in 12-channel, ±10 m accuracy |
| Barometric Pressure Sensor | 150–1150 mbar (±1 mbar) |
| Operating Temperature | −20 to +70 °C |
| Enclosure Rating | IP67 |
| Power | 5×AA alkaline or Ni-MH rechargeable batteries |
| Weight (with batteries) | 450 g |
| Dimensions (W×H×D) | 90×180×39 mm |
| Brand | Aquaterr |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | T-350 |
| Instrument Type | Soil Moisture and Temperature Meter |
| Probe Length | 75 cm |
| Probe Diameter | 1.3 cm |
| Probe Material | Aerospace-Grade Stainless Steel |
| Temperature Range | 0–65 °C |
| Moisture Range | 0–100 % RH (Relative Humidity, soil moisture equivalent) |
| Accuracy | ±1.5 % FS |
| Overall Length | 91.4 cm |
| Weight | 2.3 kg |
| Power Supply | 9 V Battery |
| Packaging Dimensions | 990 × 290 × 120 mm |
| Brand | Aquaterr |
|---|---|
| Origin | USA |
| Model | M-350 |
| Instrument Type | Capacitance-Based Soil Moisture Analyzer |
| Measurement Range | 0–100% volumetric water content (VWC) |
| Accuracy | ±1.5% VWC |
| Probe Length | 76.2 cm |
| Total Unit Length | 91.44 cm |
| Probe Material | Aerospace-Grade Stainless Steel |
| Power Supply | 9V Alkaline Battery (≈3 months typical operation) |
| Weight | 1.52 kg |
| Sensor Principle | High-Frequency Capacitance (50 MHz) |
| Compliance | Designed for field-deployable GLP-aligned data collection |
| Brand | Archimed |
|---|---|
| Origin | Japan |
| Model | MIJ-03 |
| Principle | Galvanic Oxygen Sensor with Porous Membrane |
| Measurement Range | 0–20.9% O₂ (full scale) |
| Output Signal | 45–65 mV (linear vs. O₂ concentration) |
| Accuracy | ±0.5% O₂ |
| Response Time (t₉₀) | 240 ± 30 s |
| Operating Temperature | 0–40 °C (extended range –10 to +60 °C with integrated thermistor compensation) |
| Storage Temperature | –20 to +60 °C |
| Sensor Body Material | Rigid thermoplastic housing |
| Dimensions | Ø40 mm × 78 mm (sensor head) |
| Cable Length | ~5 m (shielded, color-coded: red/+ , black/–) |
| Weight | ~220 g (including cable) |
| Temperature Compensation | Built-in NTC thermistor |
| Pressure Compensation | Internal air bubble reference |
| Humidity Effect | Negligible at 0% RH |
| Zero Output | 0 mV at 0% O₂ |
| Compliance | Designed for long-term in situ deployment per ISO 11274 (soil physical properties), compatible with GLP-aligned data acquisition systems |