Empowering Scientific Discovery

Nanjing Mingao Instrument & Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAquaterr
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelT-350
Instrument TypeSoil Moisture and Temperature Meter
Probe Length75 cm
Probe Diameter1.3 cm
Probe MaterialAerospace-Grade Stainless Steel
Temperature Range0–65 °C
Moisture Range0–100 % RH (Relative Humidity, soil moisture equivalent)
Accuracy±1.5 % FS
Overall Length91.4 cm
Weight2.3 kg
Power Supply9 V Battery
Packaging Dimensions990 × 290 × 120 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAquaterr
OriginUSA
ModelM-350
Instrument TypeCapacitance-Based Soil Moisture Analyzer
Measurement Range0–100% volumetric water content (VWC)
Accuracy±1.5% VWC
Probe Length76.2 cm
Total Unit Length91.44 cm
Probe MaterialAerospace-Grade Stainless Steel
Power Supply9V Alkaline Battery (≈3 months typical operation)
Weight1.52 kg
Sensor PrincipleHigh-Frequency Capacitance (50 MHz)
ComplianceDesigned for field-deployable GLP-aligned data collection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArchimed
OriginJapan
ModelMIJ-03
PrincipleGalvanic Oxygen Sensor with Porous Membrane
Measurement Range0–20.9% O₂ (full scale)
Output Signal45–65 mV (linear vs. O₂ concentration)
Accuracy±0.5% O₂
Response Time (t₉₀)240 ± 30 s
Operating Temperature0–40 °C (extended range –10 to +60 °C with integrated thermistor compensation)
Storage Temperature–20 to +60 °C
Sensor Body MaterialRigid thermoplastic housing
DimensionsØ40 mm × 78 mm (sensor head)
Cable Length~5 m (shielded, color-coded: red/+ , black/–)
Weight~220 g (including cable)
Temperature CompensationBuilt-in NTC thermistor
Pressure CompensationInternal air bubble reference
Humidity EffectNegligible at 0% RH
Zero Output0 mV at 0% O₂
ComplianceDesigned for long-term in situ deployment per ISO 11274 (soil physical properties), compatible with GLP-aligned data acquisition systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAquaterr
OriginUSA
ModelEC-350
Instrument TypeSoil Moisture, Temperature & Electrical Conductivity Analyzer
Probe Length76.2 cm
Probe Diameter1.27 cm
Probe MaterialAerospace-Grade Stainless Steel & Aluminum
Total Unit Length91.44 cm
Moisture Range0–100% (v/v)
Temperature Range4.44–65.55 °C
EC RangeUp to 2000 µS/cm
Moisture Sensing PrincipleCapacitive Dielectric Measurement
Temperature Sensing PrincipleSilicon Junction Sensor
EC Sensing PrincipleInductive (Non-Contact) Conductivity Measurement
Accuracy±1.5% FS
Power Supply9 V Alkaline Battery (≈3 months typical operation)
Net Weight1.52 kg
Shipping Weight2.69 kg
Packaging Dimensions79.4 × 127 × 965.2 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAMS
OriginUSA
Model209.57
Core ComponentsStainless Steel
Connection Thread5/8" Unified National Fine (UNF)
Auger Diameter5.72 cm
Handle Length45.72 cm
Split-Core Sampler Diameter × Length3.49 cm × 15.24 cm
Extension Rod Length1.2 m
Plastic Liner Diameter × Length3.49 cm × 15.24 cm
Wrench Length30.48 cm
Stainless Steel Brush Diameter × Length3.81 cm × 30.48 cm
Standard Configuration1× General-Purpose Auger, 1× Sand Auger, 1× Clay Auger, 1× Rubber-Coated Handle, 1× Split-Core Sampler, 1× Standard Sliding Hammer, 3× Extension Rods, 1× Plastic Liner, 2× Plastic Caps, 2× Fixed-Size Wrenches, 1× Adjustable Wrench, 1× Stainless Steel Brush, 1× Premium Carrying Case
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectrum Technologies
OriginUSA
ModelIQ150
Measurement RangepH 0.00–14.00
Temperature0–100 °C
Output Voltage±1999 mV
ResolutionpH 0.01/0.1, Temp 0.1 °C, Voltage 0.1/1.0 mV
AccuracypH ±0.01, Temp ±0.5 °C, Voltage ±0.1 mV
Calibration1- or 2-point
Buffer Recognition1.68, 4.00, 6.86, 7.00, 7.14, 9.18, 10.01, 11.88, 12.45
Temperature CompensationManual or Automatic (0–100 °C)
Power Supply9 V DC battery or 12 V AC adapter
Dimensions90 × 180 × 40 mm
Weight1300 g
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0