Near Infrared Spectrometer
Filter
Showing 61–90 of 97 results
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Country of Origin | Imported |
| Model | DS2500 L |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | Grating-scanning monochromator |
| Wavelength Range | 400–2500 nm |
| Scan Speed | 32 scans per second |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Vision Air |
| Brand | Metrohm |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DS 2500 |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 400–2500 nm |
| Scan Speed | 2 scans/sec |
| Data Sampling Interval | 0.5 nm |
| Measurement Modes | Diffuse Reflectance / Transflectance |
| Chemometrics Software | Vision |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | OMNIS NIR |
| Instrument Type | Benchtop Laboratory Spectrometer |
| Principle | Fixed-grating array-detector non-scanning design |
| Wavelength Range | 1000–2250 nm |
| Scan Speed | 300 spectra/s |
| Data Sampling Interval | 0.5 nm |
| Sample Modes | Diffuse Reflectance / Transmission / Transflection |
| Chemometrics Software | OMNIS Platform |
| Brand | Metrohm |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PRO Online NIR |
| Instrument Type | Online Process Analyzer |
| Application Field | Petrochemical Industry |
| Operating Principle | Fixed Grating with Diode Array Detector (Non-Scanning) |
| Wavelength Range | 1100–1650 nm (Reflectance), 850–1050 nm (Transmittance) |
| Scan Speed | 0.5 s per spectrum |
| Spectral Sampling Interval | 0.5 nm |
| Sample Interface Modes | Diffuse Reflectance (Solids), Transflectance (Liquids), Transmission (Liquids) |
| Chemometrics Software | Vision with ISIcal™ |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | microPHAZIR AS |
| Price Range | USD 70,000–140,000 (FOB) |
| Principle | Portable, Non-Contact Reflectance NIR Spectroscopy |
| Measurement Time | <10 s |
| Sampling Mode | Non-Contact Diffuse Reflectance |
| Weight | 1.25 kg |
| Housing | Ruggedized Dust-Resistant Polymer Enclosure |
| Light Source | Tungsten-Halogen Lamp (Class 1 LED-equivalent Safety) |
| Data Interface | Internal Flash Memory + USB 2.0 Host Interface |
| Operating Temperature | 5–40 °C (non-condensing) |
| Power Supply | Dual Hot-Swappable Li-ion Batteries (4.5 h typical runtime) |
| Optional Accessories | AC Battery Charger, Carrying Case with Belt Clip |
| Brand | Ocean Insight |
|---|---|
| Model | NIRQuest+ |
| Type | Portable Grating-Based Spectrometer |
| Wavelength Range | 900 nm – 2500 nm |
| Detector Cooling | Thermoelectric (TEC) to –20 °C |
| Dark Current | Low |
| Signal-to-Noise Ratio | High |
| Integration Time | Short (ms-scale typical) |
| Optical Compatibility | Fully compatible with Ocean Insight light sources, optical fibers, and sampling accessories |
| Configurations | NIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Ocean Optics |
|---|---|
| Model | FLAME-NIR |
| Type | Portable NIR Spectrometer |
| Wavelength Range | 950–1650 nm |
| Optical Resolution | ~10 nm FWHM (configuration-dependent) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 |
| Integration Time | 1 ms – 65 s |
| Scan Rate | 400 spectra/s |
| Detector | Uncooled InGaAs linear array (128 pixels, 900–1700 nm response) |
| Dimensions | 89.1 × 63.3 × 34.4 mm (incl. feet) |
| Weight | 265 g |
| Interface | Micro-USB (plug-and-play) |
| Software Compatibility | OceanView, NIR Tools, and third-party chemometrics platforms (e.g., MATLAB, Python with Ocean SDK) |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Ocean Optics |
|---|---|
| Model | Flame-NIR+ |
| Type | Portable Spectrometer |
| Principle | Grating-based Scanning Spectroscopy |
| Wavelength Range | 970–1700 nm |
| Optical Resolution | ~10 nm FWHM (25 µm slit) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 (single acquisition) |
| Thermal Drift | 0.08 nm/°C |
| Maximum Scan Rate | ~400 Hz |
| Integration Time | 1 ms – 45 s |
| Detector | Uncooled InGaAs linear array (128 pixels) |
| Dimensions | 89.1 × 63.3 × 31.9 mm (34.4 mm including feet) |
| Weight | 265 g |
| Interface | Micro-USB |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Ocean Optics |
|---|---|
| Model | NIRQuest |
| Type | Laboratory-grade, Fiber-coupled, Thermoelectrically Cooled InGaAs Array Spectrometer |
| Wavelength Range | 900–1700 nm (standard), up to 2500 nm (optional configurations) |
| Optical Resolution | Configurable via slit width (10–200 µm) and grating selection |
| Detector | Hamamatsu InGaAs linear array (512 or 256 pixels) |
| Cooling | Thermoelectric (TEC), stabilized to ~30 °C below ambient |
| A/D Converter | 16-bit USB interface |
| Integration Time | As low as 1 ms |
| Measurement Modes | Diffuse reflectance, transmission |
| Software Compatibility | SpectraSuite (with spectral acquisition, real-time processing, and basic chemometric tools) |
| Compliance | CE, RoHS, FDA 21 CFR Part 11-ready via optional audit-trail configuration |
| Sample Interface | SMA905 fiber optic connector |
| Brand | Oceanhood |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | NirIn |
| Instrument Type | Online Process Spectrometer |
| Wavelength Range | 900–1700 nm |
| Optical Resolution | 5 nm |
| Spectral Stability | <2% peak-to-peak deviation over 72 h continuous operation |
| Frame Rate | >1000 spectra/s |
| Integration Time | 100 µs – 30 s |
| Host Dimensions | 430 × 328 × 88.1 mm |
| Probe Head Dimensions | 250 × 200 × 250 mm |
| Spot Diameter | Up to 10 cm |
| Fiber Optic Cable Compatibility | Customizable fused-silica patch cables (1–100 m) |
| Data Interfaces | USB 2.0, RS-232 serial |
| Output Formats | JDX, SPC, CSV, TXT, PDF, JPEG |
| Operating Temperature | −10 to +50 °C |
| Operating Humidity | 5–80% RH (non-condensing) |
| Power Supply | 220 V AC, 50/60 Hz |
| Compliance | CE-marked |
| Brand | Optosky |
|---|---|
| Model | IR2110 |
| Detector | InGaAs Linear Diode Array |
| Wavelength Range | 900–1700 nm (standard configuration) |
| Optical Resolution | ≤ 8 nm (FWHM) |
| Signal-to-Noise Ratio | > 10,000:1 (at full integration time) |
| Integration Time | 1 ms – 10 s |
| Interface | USB 3.0, RS232, Ethernet (optional) |
| IP Rating | IP65/IP67 |
| Operating Temperature | −10 °C to +50 °C |
| Light Source Lifetime | > 40,000 h |
| Software Compatibility | Windows 10/11, Linux (SDK available) |
| Compliance | CE, RoHS, ISO/IEC 17025 applicable for method validation |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Spectrum Two N |
| Instrument Type | Laboratory Benchtop |
| Operating Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 680–4800 nm |
| Data Sampling Interval | 1/4 resolution or user-defined |
| Sample Introduction | Direct sampling (reflectance, transmission, remote probe) |
| Software | Spectrum 10™ Suite (including Spectrum 10 ES, Spectrum Touch™, Spectrum Adulterant Screen, Spectrum Quant™ Advanced Algorithms Pack, Spectrum AssureID) |
| Brand | Perten |
|---|---|
| Origin | United Kingdom |
| Model | Spectrum Two N |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform (Interferometric) |
| Wavelength Range | 680–4800 nm |
| Data Sampling Interval | 1/4 resolution or user-defined |
| Sample Introduction | Direct sampling |
| Software | Spectrum 10™ Suite (including Spectrum 10 ES, Spectrum Touch™, Spectrum Adulterant Screen, Spectrum Quant™ Advanced Algorithms Pack, Spectrum AssureID) |
| Brand | Perten |
|---|---|
| Origin | USA |
| Model | DA 7350 |
| Instrument Type | Online |
| Wavelength Range | 950–1650 nm |
| Scan Speed | >30 sub-spectra per second |
| Data Sampling Interval | User-Configurable |
| Measurement Modes | Near-Infrared Reflectance & Digital Color Imaging |
| Chemometrics Software | PerCAL |
| Compliance | Designed for GLP/GMP environments |
| Communication Protocols | OPC UA, PROFINET, Modbus TCP, Fieldbus |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | DA7250 |
| Instrument Type | Laboratory |
| Principle | Grating-based non-scanning diode array spectrometry |
| Wavelength Range | 950–1650 nm |
| Scan Speed | 100 spectra/sec |
| Data Sampling Interval | 0.008 s |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | Unscrambler |
| Detector | Thermoelectrically Cooled InGaAs Diode Array |
| Optical Resolution | Adjustable from 0.1 nm to 10 nm |
| Spectral Bandwidth | ~7 nm |
| Wavelength Accuracy | <0.05 nm |
| Wavelength Repeatability | <0.02 nm (per measurement), <0.2 nm/year |
| Absorbance Range | 0–2.5 AU |
| Noise Level | <20 µA (10 s continuous acquisition) |
| Light Source Lifetime | >10,000 h |
| Operating Temperature | 0–40 °C |
| IP Rating | IP65 |
| Sample Weight Capacity | 0.5–300 g (solids), 2–100 mL (liquids) |
| Standard Sample Area | 154 cm² (large cup), 44 cm² (small cup) |
| Analysis Time | ≤6 s per sample |
| Measurement Geometry | Non-contact rotating scan |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | DA7430M |
| Instrument Type | Online |
| Principle | Grating Scanning NIR Spectrometer |
| Wavelength Range | 950–1650 nm |
| Scan Speed | 30 subspectra/second |
| Sampling Interval | User-Configurable |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | Unscrambler X, Percal |
| Ingress Protection Rating | IP67 |
| Optical Spot Diameter | >10 cm |
| Light Source | Long-Life Xenon Lamp |
| Mounting Compatibility | Chutes, Screw Conveyors, Belt Conveyors, Mixers, Scrapers |
| Communication Protocols | OPC UA, Ethernet, Modbus TCP/IP, 4–20 mA Analog Output, Profibus |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | DA7440 |
| Instrument Type | Online |
| Principle | Grating Scanning |
| Wavelength Range | 950–1650 nm |
| Scan Speed | 30 subspectra/sec |
| Data Sampling Interval | User-Configurable |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | Unscrambler X, Percal |
| Brand | Perten |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FT 9700 |
| Instrument Type | Laboratory |
| Application Domain | General-purpose (Academic & Research) |
| Operating Principle | Fourier Transform (FT) |
| Wavelength Range | 700–2500 nm (14,300–4000 cm⁻¹) |
| Scan Speed | <1 minute per spectrum |
| Data Sampling Interval | Adjustable |
| Sample Measurement Modes | Diffuse Reflectance and Transflectance |
| Chemometrics Software | PerCal |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | IM 8800 |
| Instrument Type | Portable |
| Application Field | Cereals & Oilseeds |
| Measurement Principle | Grating-based diode array (non-scanning) |
| Wavelength Range | 850–1050 nm |
| Scan Time | 20 seconds |
| Data Sampling Interval | 5 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Unscrambler® |
| GPS Integration | Yes |
| Power Supply | 12 V DC or internal rechargeable battery (2 h runtime) |
| Compliance | AACC Method 39-25 |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | IM9520 |
| Instrument Type | Benchtop Laboratory NIR Spectrometer |
| Application Domain | Cereal Grains & Milled Flour |
| Optical Principle | Grating Scanning Transmission NIR |
| Wavelength Range | 570–1100 nm |
| Scan Speed | 10 scans/minute |
| Data Acquisition Interval | 6 seconds per measurement |
| Sample Mode | Transmission |
| Chemometrics Software | Unscrambler® |
| Calibration Framework | NIST-traceable wavelength calibration |
| Compliance | ASTM D6341 (NIR for cereal analysis), ISO 12099:2017 (Animal feeding stuffs — General guidelines for the determination of chemical constituents by NIR spectroscopy), GLP-compliant data audit trail support via NetPlus™ |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | IM 9500plus |
| Instrument Type | Laboratory NIR Spectrometer |
| Application Domain | Cereal & Oilseed Analysis |
| Principle | Grating Scanning Transmission NIR |
| Wavelength Range | 570–1100 nm |
| Scan Speed | 10 scans/min |
| Data Acquisition Interval | 6 s/scan |
| Measurement Mode | Transmission |
| Chemometrics Software | Unscrambler X |
| Brand | Rayleigh |
|---|---|
| Origin | Beijing, China |
| Model | WQF-600N |
| Instrument Principle | Fourier Transform (FT) |
| Wavenumber Range | 3300–10000 cm⁻¹ |
| Spectral Resolution | < 4 cm⁻¹ |
| Wavenumber Accuracy | Better than half the set resolution |
| Transmittance Repeatability | ±0.5% T |
| Signal-to-Noise Ratio (S/N) | >10,000:1 (RMS, 32 scans at 4300–4400 cm⁻¹) |
| Beam Splitter | CaF₂ |
| Detector Options | DTGS (PbS, InGaAs optional) |
| Light Source | Air-cooled tungsten-halogen lamp |
| Data System | PC-based with Windows OS |
| Software | Full-featured FT-NIR acquisition, preprocessing, chemometric modeling, and spectral analysis suite compliant with ASTM E1655 and ISO 12099 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Antaris II |
| Instrument Type | Laboratory |
| Operating Principle | Fourier Transform (FT) |
| Wavelength Range | 3800–12000 cm⁻¹ |
| Scan Speed | 5 scans/sec |
| Data Sampling Interval | 2 cm⁻¹ |
| Measurement Modes | Transmission, Diffuse Reflectance, Transflectance, Transdiffuse |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Antaris MX |
| Instrument Type | Online/At-line Portable FT-NIR Analyzer |
| Principle | Fourier Transform Near-Infrared Spectroscopy (FT-NIR) with Real-time Process Integration |
| Wavelength Range | 4000–12000 cm⁻¹ |
| Scan Speed | 5 scans per second |
| Spectral Resolution | 2 cm⁻¹ (data sampling interval) |
| Measurement Modes | Transmission, Transflection, Diffuse Reflectance |
| Chemometrics Software | TQ Analyst v9+ and RESULT v3.x |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Antaris Target In-Process Mixing Monitor |
| Instrument Category | Online Near-Infrared Spectrometer |
| Operating Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 5300–7500 cm⁻¹ |
| Scan Speed | 12.5 scans/second |
| Spectral Sampling Interval | 0.7 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | TQ Analyst |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | microPHAZIR GP |
| Principle | Portable, Non-Destructive NIR Spectroscopy |
| Weight | 1.3 kg |
| Spectral Range | 1600–2400 nm |
| Measurement Time | ≤3 s (configurable) |
| Light Source | Tungsten-Halogen Lamp |
| Data Storage | Internal Memory |
| Data Transfer | USB (text-based .csv/.txt) |
| Operating Temperature | 5–40 °C |
| Battery | Rechargeable Li-ion with Hot-Swap Capability |
| Enclosure | Dust- and Splash-Resistant High-Impact Polymer Housing |
| Security | Multi-Level Password Protection |
| Standard Accessories | Rugged Waterproof Carry Case, Li-ion Battery Pack, 110/220 VAC Charger, Lanyard |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | microPHAZIR PC Carpet |
| Principle | Portable, On-Site NIR Spectroscopy |
| Weight | 1.25 kg |
| Measurement Time | 1.5 s |
| Light Source | Tungsten-Halogen Lamp |
| Display | Color LCD |
| Data Interface | USB to PC |
| Battery | Rechargeable Li-ion (≥5 h runtime, <2 h recharge time, dual-battery configuration) |
| Enclosure | Dust- and Splash-Resistant Engineering Plastic |
| Preloaded Library | Carpet Fiber Identification Database |
| Security | Multi-Level Password Protection |
| Calibration | Factory-Calibrated, Ready-to-Use Out-of-Box |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | microPHAZIR PC Plastics |
| Principle | Portable, On-Site NIR Spectroscopy |
| Spectral Range | 1600–2400 nm (6250–4100 cm⁻¹) |
| Measurement Time | <3 s |
| Sampling Mode | Diffuse Reflectance |
| Weight | 1.25 kg |
| Housing | High-Strength Dust-Resistant Polymer Enclosure |
| Light Source | Tungsten-Halogen Lamp |
| Data Storage | Internal Memory with USB Export |
| Interface | USB |
| Operating Temperature | 5–50 °C (non-condensing) |
| Power Supply | Dual Swappable Li-ion Batteries (4.5 h runtime), AC Adapter & Charger Included |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | microPHAZIR™ Rx |
| Instrument Category | Portable NIR Spectrometer |
| Principle | Portable, non-destructive near-infrared reflectance spectroscopy |
| Wavelength Range | 1600–2400 nm |
| Scan Rate | 2 spectra per second |
| Data Acquisition Interval | 0.5 s (2 Hz) |
| Measurement Mode | Contact-based diffuse reflectance NIR analysis |
| Chemometrics Software | Method Generator™ |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Models | TruScan RM, microPHAZIR RX |
| Principle | Portable, Non-Destructive, In-Situ Spectroscopic Identification |
| Regulatory Compliance | 21 CFR Part 11, USP <1119>, EP 2.2.48, ASTM E1840, ISO/IEC 17025 |