| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2060NIR |
| Instrument Type | Online NIR Spectrometer |
| Application Scope | General-purpose (Academic & Research Laboratories) |
| Operating Principle | Grating-based, Non-scanning Array Detector |
| Wavelength Range | 1000–2250 nm |
| Scan Rate | 5000 spectra/s |
| Spectral Sampling Interval | 0.5 nm |
| Measurement Mode | Real-time In-line Analysis |
| Chemometrics Software | IMPACT / OMNIS |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Country of Origin | Imported |
| Model | DS2500 L |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | Grating-scanning monochromator |
| Wavelength Range | 400–2500 nm |
| Scan Speed | 32 scans per second |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Vision Air |
| Brand | Metrohm |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DS 2500 |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 400–2500 nm |
| Scan Speed | 2 scans/sec |
| Data Sampling Interval | 0.5 nm |
| Measurement Modes | Diffuse Reflectance / Transflectance |
| Chemometrics Software | Vision |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | OMNIS NIR |
| Instrument Type | Benchtop Laboratory Spectrometer |
| Principle | Fixed-grating array-detector non-scanning design |
| Wavelength Range | 1000–2250 nm |
| Scan Speed | 300 spectra/s |
| Data Sampling Interval | 0.5 nm |
| Sample Modes | Diffuse Reflectance / Transmission / Transflection |
| Chemometrics Software | OMNIS Platform |
| Brand | Metrohm |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PRO Online NIR |
| Instrument Type | Online Process Analyzer |
| Application Field | Petrochemical Industry |
| Operating Principle | Fixed Grating with Diode Array Detector (Non-Scanning) |
| Wavelength Range | 1100–1650 nm (Reflectance), 850–1050 nm (Transmittance) |
| Scan Speed | 0.5 s per spectrum |
| Spectral Sampling Interval | 0.5 nm |
| Sample Interface Modes | Diffuse Reflectance (Solids), Transflectance (Liquids), Transmission (Liquids) |
| Chemometrics Software | Vision with ISIcal™ |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | microPHAZIR AS |
| Price Range | USD 70,000–140,000 (FOB) |
| Principle | Portable, Non-Contact Reflectance NIR Spectroscopy |
| Measurement Time | <10 s |
| Sampling Mode | Non-Contact Diffuse Reflectance |
| Weight | 1.25 kg |
| Housing | Ruggedized Dust-Resistant Polymer Enclosure |
| Light Source | Tungsten-Halogen Lamp (Class 1 LED-equivalent Safety) |
| Data Interface | Internal Flash Memory + USB 2.0 Host Interface |
| Operating Temperature | 5–40 °C (non-condensing) |
| Power Supply | Dual Hot-Swappable Li-ion Batteries (4.5 h typical runtime) |
| Optional Accessories | AC Battery Charger, Carrying Case with Belt Clip |
| Brand | Ocean Insight |
|---|---|
| Model | NIRQuest+ |
| Type | Portable Grating-Based Spectrometer |
| Wavelength Range | 900 nm – 2500 nm |
| Detector Cooling | Thermoelectric (TEC) to –20 °C |
| Dark Current | Low |
| Signal-to-Noise Ratio | High |
| Integration Time | Short (ms-scale typical) |
| Optical Compatibility | Fully compatible with Ocean Insight light sources, optical fibers, and sampling accessories |
| Configurations | NIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Ocean Optics |
|---|---|
| Model | FLAME-NIR |
| Type | Portable NIR Spectrometer |
| Principle | Fiber-coupled, non-cooled InGaAs-based dispersive spectroscopy |
| Wavelength Range | 950–1650 nm |
| Optical Resolution | ~10 nm FWHM (configuration-dependent) |
| Scan Rate | 400 spectra/sec |
| Integration Time | 1 ms – 65 s |
| Sampling Interval | 1 ms – 65 s |
| Measurement Mode | Transmission |
| Detector | Uncooled 128-pixel InGaAs linear array (900–1700 nm response) |
| SNR | 6000:1 (full signal) |
| Dynamic Range | 6000:1 |
| Dimensions | 89.1 × 63.3 × 34.4 mm (incl. feet) |
| Weight | 265 g |
| Interface | Micro-USB (plug-and-play) |
| Software Compatibility | OceanView, OceanInsight NIR Chemometrics Suite |
| Compliance | CE, RoHS, FCC Class B |
| Modularity | Interchangeable slits, fiber-optic coupling, OEM-ready architecture |
| Brand | Ocean Optics |
|---|---|
| Model | FLAME-NIR |
| Type | Portable NIR Spectrometer |
| Principle | Fiber-coupled, non-cooled InGaAs detection |
| Wavelength Range | 950–1650 nm |
| Optical Resolution | ~10 nm FWHM (configuration-dependent) |
| Scan Rate | 400 spectra/sec |
| Integration Time | 1 ms – 65 s |
| Sampling Interval | 1 ms → 65 s |
| Measurement Mode | Transmission |
| Detector | Uncooled 128-pixel InGaAs array (900–1700 nm response) |
| SNR | 6000:1 (full signal) |
| Dynamic Range | 6000:1 |
| Dimensions | 89.1 × 63.3 × 34.4 mm (incl. feet) |
| Weight | 265 g |
| Interface | Micro-USB (plug-and-play) |
| Software Compatibility | OceanView, OmniDriver, NIR chemometrics suite |
| Slit Options | User-replaceable for resolution/sensitivity tuning |
| LED Indicators | Power & acquisition status |
| Brand | Ocean Optics |
|---|---|
| Model | FLAME-NIR |
| Type | Portable NIR Spectrometer |
| Wavelength Range | 950–1650 nm |
| Optical Resolution | ~10 nm FWHM (configuration-dependent) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 |
| Integration Time | 1 ms – 65 s |
| Scan Rate | 400 spectra/s |
| Detector | Uncooled InGaAs linear array (128 pixels, 900–1700 nm response) |
| Dimensions | 89.1 × 63.3 × 34.4 mm (incl. feet) |
| Weight | 265 g |
| Interface | Micro-USB (plug-and-play) |
| Software Compatibility | OceanView, NIR Tools, and third-party chemometrics platforms (e.g., MATLAB, Python with Ocean SDK) |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Ocean Optics |
|---|---|
| Model | Flame-NIR+ |
| Type | Portable Spectrometer |
| Principle | Grating-based Scanning Spectroscopy |
| Wavelength Range | 970–1700 nm |
| Optical Resolution | ~10 nm FWHM (25 µm slit) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 (single acquisition) |
| Thermal Drift | 0.08 nm/°C |
| Maximum Scan Rate | ~400 Hz |
| Integration Time | 1 ms – 45 s |
| Detector | Uncooled InGaAs linear array (128 pixels) |
| Dimensions | 89.1 × 63.3 × 31.9 mm (34.4 mm including feet) |
| Weight | 265 g |
| Interface | Micro-USB |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Ocean Optics |
|---|---|
| Model | Flame-NIR+ |
| Type | Portable NIR Spectrometer |
| Principle | Grating-based Scanning Spectrometer |
| Wavelength Range | 970–1700 nm |
| Optical Resolution | ~10 nm FWHM (25 µm slit) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 (single acquisition) |
| Thermal Drift | 0.08 nm/°C |
| Scan Rate | ~400 Hz |
| Integration Time | 1 ms to 45 s |
| Detector | Uncooled InGaAs linear array (128 pixels) |
| Dimensions | 89.1 × 63.3 × 31.9 mm (34.4 mm including feet) |
| Weight | 265 g |
| Interface | Micro-USB |
| Origin | Shanghai, China |
| Manufacturer | Ocean Optics (Shanghai) |
| Brand | Ocean Optics |
|---|---|
| Model | Flame-NIR+ |
| Type | Handheld NIR Spectrometer |
| Optical Principle | Grating-based Scanning |
| Wavelength Range | 970–1700 nm |
| Optical Resolution | ~10 nm FWHM (25 µm slit) |
| Signal-to-Noise Ratio | 6000:1 (full signal) |
| Dynamic Range | 6000:1 (single acquisition) |
| Thermal Drift | 0.08 nm/°C |
| Scan Rate | ~400 Hz |
| Integration Time | 1 ms – 45 s |
| Detector | Uncooled InGaAs linear array (128 pixels) |
| Dimensions | 89.1 × 63.3 × 31.9 mm (34.4 mm including feet) |
| Weight | 265 g |
| Interface | Micro-USB |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Origin | Domestic (China) |
| Model | NIRQuest |
| Instrument Type | Laboratory |
| Application Field | Grain Analysis |
| Operating Principle | Portable & Online Deployment |
| Wavelength Range | 900–1700 nm (extendable to 2500 nm) |
| Scan Speed | 1 ms |
| Measurement Mode | Diffuse Reflectance / Transmission |
| Detector | InGaAs Linear Array with Integrated Thermoelectric Cooling |
| Optical Platform | Crossed Czerny-Turner |
| A/D Resolution | 16-bit USB |
| Interface | SMA905 Fiber Optic Connector |
| Compliance | Compatible with ASTM E1655, ISO 12099, USP <856>, and GLP/GMP-aligned data workflows |
| Brand | Ocean Optics |
|---|---|
| Model | NIRQuest |
| Type | Laboratory Benchtop / Portable Fiber-Optic NIR Spectrometer |
| Wavelength Range | 900–1700 nm (standard), up to 2500 nm (optional configurations) |
| Detector | Hamamatsu InGaAs linear array (512 or 256 pixels) |
| Cooling | Thermoelectric (TEC), stabilized to ~30 °C below ambient |
| Optical Platform | Crossed Czerny-Turner |
| A/D Resolution | 16-bit USB interface |
| Integration Time | As low as 1 ms |
| Sampling Modes | Diffuse reflectance, transmission |
| Grating Options | Multiple groove densities for resolution/sensitivity trade-offs |
| Slit Options | 10, 25, 50, 100, or 200 µm width or fiber-coupled (no slit) |
| Interface | SMA 905 fiber port |
| Software Compatibility | SpectraSuite (with spectral acquisition, basic preprocessing, and export functions) |
| Compliance | Designed for GLP-aligned workflows |
| Brand | Ocean Optics |
|---|---|
| Model | NIRQuest |
| Type | Laboratory-grade, Fiber-coupled, Thermoelectrically Cooled InGaAs Array Spectrometer |
| Wavelength Range | 900–1700 nm (standard), up to 2500 nm (optional configurations) |
| Optical Resolution | Configurable via slit width (10–200 µm) and grating selection |
| Detector | Hamamatsu InGaAs linear array (512 or 256 pixels) |
| Cooling | Thermoelectric (TEC), stabilized to ~30 °C below ambient |
| A/D Converter | 16-bit USB interface |
| Integration Time | As low as 1 ms |
| Measurement Modes | Diffuse reflectance, transmission |
| Software Compatibility | SpectraSuite (with spectral acquisition, real-time processing, and basic chemometric tools) |
| Compliance | CE, RoHS, FDA 21 CFR Part 11-ready via optional audit-trail configuration |
| Sample Interface | SMA905 fiber optic connector |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | NIRQuest |
| Detector Options | 512-element or 256-element InGaAs array |
| Wavelength Range | 900–2500 nm |
| Optical Resolution (FWHM) | 3.1–11.0 nm (model-dependent) |
| Grating Options | NIR1, NIR2, NIR3 |
| Slit | SLIT-25 (25 µm) standard |
| Calibration Sources | AR-1 Argon (696–1704 nm), XE-1 Xenon (916–1894 nm) |
| Software | SpectraSuite (Windows/macOS/Linux) |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 ready (with audit trail enabled) |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | NIRQuest+ |
| Instrument Type | Portable |
| Operating Principle | Grating-Based Scanning Spectrometer |
| Wavelength Range | 900 nm – 2500 nm |
| Detector | Thermoelectrically Cooled InGaAs Linear Array |
| Slit Width | 25 µm |
| Optical Resolution (FWHM) | 3.13 nm (typ.), 5.47 nm (typ.), 6.25 nm (typ.) |
| Integration Time | 1 ms – 12 s |
| Dark Noise | 6–24 RMS counts (dependent on integration time) |
| Dynamic Range | 7.5 × 10⁴ (system) |
| 10,000 | 1 (single acquisition) |
| Signal-to-Noise Ratio | >15,000:1 @ 100 ms |
| >13,000 | 1 @ 1000 ms |
| Dimensions | 182 × 110 × 47 mm |
| Weight | 1.18 kg (without power supply) |
| Fiber Connector | SMA 905 |
| Order-Sorting Filter | OF1-RG830 Longpass NIR Filter (optional) |
| Grating Options | GRATING_#NIR1, GRATING_#NIR2, GRATING_#NIR3 |
| Brand | Ocean Optics |
|---|---|
| Model | NIRQuest+ |
| Detector | InGaAs linear array |
| Wavelength Range | 900 nm – 2500 nm |
| Optical Resolution (FWHM) | 3.13 nm (typ.), 5.47 nm (typ.), 6.25 nm (typ.) |
| Slit | 25 µm |
| Cooling | Thermoelectric to –20 °C |
| Integration Time | 1 ms – 12 s |
| Dark Noise | 6–24 RMS counts (dependent on integration time) |
| Dynamic Range | 7.5 × 10⁴ (system) |
| 10,000 | 1 (single acquisition) |
| SNR | >15,000:1 @ 100 ms |
| >13,000 | 1 @ 1000 ms |
| Dimensions | 182 × 110 × 47 mm |
| Weight | 1.18 kg (without power supply) |
| Fiber Connector | SMA 905 |
| Order-Sorting Filter | OF1-RG830 long-pass NIR filter (optional) |
| Grating Options | GRATING_#NIR1, GRATING_#NIR2, GRATING_#NIR3 |
| Spectral Configuration Options | NIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm) |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory |
| Optical Principle | Fixed-grating array-detector non-scanning spectrometer |
| Wavelength Ranges | NIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm) |
| Detector | InGaAs linear array (TE-cooled) |
| Resolution | 1.7–4.0 nm FWHM (configuration-dependent) |
| Integration Time | 1 ms to 65 s |
| Interface | USB 3.0 or Ethernet (optional) |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 ready (with compliant software stack) |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NIRQuest+ |
| Instrument Type | Laboratory & Process-Ready |
| Optical Principle | Fixed-grating spectrometer with linear array detector (non-scanning) |
| Wavelength Ranges | NIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm) |
| Detector | InGaAs linear array (TE-cooled) |
| Optical Resolution (FWHM) | 1.7–5.0 nm (configurable by slit and grating) |
| Integration Time | 1 ms to 65 s |
| Signal-to-Noise Ratio | ≥15,000:1 (at full signal, 1 s integration, NIRQuest+2.5) |
| Dynamic Range | >25,000:1 (with 16-bit ADC) |
| Interface | USB 2.0 / USB 3.0 (via optional adapter) |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Oceanhood |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | NirIn |
| Instrument Type | Online Process Spectrometer |
| Wavelength Range | 900–1700 nm |
| Optical Resolution | 5 nm |
| Spectral Stability | <2% peak-to-peak deviation over 72 h continuous operation |
| Frame Rate | >1000 spectra/s |
| Integration Time | 100 µs – 30 s |
| Host Dimensions | 430 × 328 × 88.1 mm |
| Probe Head Dimensions | 250 × 200 × 250 mm |
| Spot Diameter | Up to 10 cm |
| Fiber Optic Cable Compatibility | Customizable fused-silica patch cables (1–100 m) |
| Data Interfaces | USB 2.0, RS-232 serial |
| Output Formats | JDX, SPC, CSV, TXT, PDF, JPEG |
| Operating Temperature | −10 to +50 °C |
| Operating Humidity | 5–80% RH (non-condensing) |
| Power Supply | 220 V AC, 50/60 Hz |
| Compliance | CE-marked |
| Brand | Optosky |
|---|---|
| Model | IR2110 |
| Detector | InGaAs Linear Diode Array |
| Wavelength Range | 900–1700 nm (standard configuration) |
| Optical Resolution | ≤ 8 nm (FWHM) |
| Signal-to-Noise Ratio | > 10,000:1 (at full integration time) |
| Integration Time | 1 ms – 10 s |
| Interface | USB 3.0, RS232, Ethernet (optional) |
| IP Rating | IP65/IP67 |
| Operating Temperature | −10 °C to +50 °C |
| Light Source Lifetime | > 40,000 h |
| Software Compatibility | Windows 10/11, Linux (SDK available) |
| Compliance | CE, RoHS, ISO/IEC 17025 applicable for method validation |
| Brand | PerfectLight |
|---|---|
| Model | DT-Series (e.g., DT 350, DT 405, DT 550, etc.) |
| Substrate Material | Fused Silica |
| Diameter | 63 mm |
| Clear Aperture | >57 mm |
| Center Wavelength Range | 320–700 nm (UV-Vis) |
| Full Width at Half Maximum (FWHM) | 20 nm ±3 nm |
| Blocking Range | OD ≥4 from 200–1200 nm (typical) |
| Surface Quality | 20–10 scratch-dig |
| Parallelism | <3 arcsec |
| Transmission Peak | >85% (typical) |
| Operating Temperature | –20 °C to +70 °C |
| Compliance | ISO 9001-manufactured, RoHS-compliant |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | UVref |
| Filter Type | Cut-On / Cut-Off, Bandpass, and Narrowband |
| Substrate Material | Fused Silica (Quartz) |
| Diameter | 63 mm |
| Clear Aperture | >57 mm |
| Spectral Range | 320–2500 nm |
| Optical Density (OD) @ Blocking Region | ≥4.0 (typ.) |
| Surface Quality | 20–10 scratch-dig |
| Parallelism | <3 arcsec |
| Coating Type | Hard Dielectric Multilayer |
| Incident Angle | 0° ± 2° (for specified spectral performance) |
| Compliance | ISO 9001-manufactured optical components |
| Application Domain | Laboratory-based NIR, UV-Vis, and FT-NIR spectroscopy systems |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Spectrum Two N |
| Instrument Type | Laboratory Benchtop |
| Operating Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 680–4800 nm |
| Data Sampling Interval | 1/4 resolution or user-defined |
| Sample Introduction | Direct sampling (reflectance, transmission, remote probe) |
| Software | Spectrum 10™ Suite (including Spectrum 10 ES, Spectrum Touch™, Spectrum Adulterant Screen, Spectrum Quant™ Advanced Algorithms Pack, Spectrum AssureID) |
| Brand | Perten |
|---|---|
| Origin | United Kingdom |
| Model | Spectrum Two N |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform (Interferometric) |
| Wavelength Range | 680–4800 nm |
| Data Sampling Interval | 1/4 resolution or user-defined |
| Sample Introduction | Direct sampling |
| Software | Spectrum 10™ Suite (including Spectrum 10 ES, Spectrum Touch™, Spectrum Adulterant Screen, Spectrum Quant™ Advanced Algorithms Pack, Spectrum AssureID) |
| Brand | Perten |
|---|---|
| Origin | USA |
| Model | DA 7350 |
| Instrument Type | Online |
| Wavelength Range | 950–1650 nm |
| Scan Speed | >30 sub-spectra per second |
| Data Sampling Interval | User-Configurable |
| Measurement Modes | Near-Infrared Reflectance & Digital Color Imaging |
| Chemometrics Software | PerCAL |
| Compliance | Designed for GLP/GMP environments |
| Communication Protocols | OPC UA, PROFINET, Modbus TCP, Fieldbus |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | DA7250 |
| Instrument Type | Laboratory |
| Principle | Grating-based non-scanning diode array spectrometry |
| Wavelength Range | 950–1650 nm |
| Scan Speed | 100 spectra/sec |
| Data Sampling Interval | 0.008 s |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | Unscrambler |
| Detector | Thermoelectrically Cooled InGaAs Diode Array |
| Optical Resolution | Adjustable from 0.1 nm to 10 nm |
| Spectral Bandwidth | ~7 nm |
| Wavelength Accuracy | <0.05 nm |
| Wavelength Repeatability | <0.02 nm (per measurement), <0.2 nm/year |
| Absorbance Range | 0–2.5 AU |
| Noise Level | <20 µA (10 s continuous acquisition) |
| Light Source Lifetime | >10,000 h |
| Operating Temperature | 0–40 °C |
| IP Rating | IP65 |
| Sample Weight Capacity | 0.5–300 g (solids), 2–100 mL (liquids) |
| Standard Sample Area | 154 cm² (large cup), 44 cm² (small cup) |
| Analysis Time | ≤6 s per sample |
| Measurement Geometry | Non-contact rotating scan |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | DA7430M |
| Instrument Type | Online |
| Principle | Grating Scanning NIR Spectrometer |
| Wavelength Range | 950–1650 nm |
| Scan Speed | 30 subspectra/second |
| Sampling Interval | User-Configurable |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | Unscrambler X, Percal |
| Ingress Protection Rating | IP67 |
| Optical Spot Diameter | >10 cm |
| Light Source | Long-Life Xenon Lamp |
| Mounting Compatibility | Chutes, Screw Conveyors, Belt Conveyors, Mixers, Scrapers |
| Communication Protocols | OPC UA, Ethernet, Modbus TCP/IP, 4–20 mA Analog Output, Profibus |