| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MATRIX-F II |
| Instrument Type | Online FT-NIR Spectrometer |
| Measurement Principle | Fourier Transform (FT) Interferometry |
| Sampling Modes | Diffuse Reflectance, Transflectance, Liquid Transmission (with variable-pathlength fiber-optic probes) |
| Chemometrics Software | OPUS |
| Compliance | Designed for industrial process environments per IEC 61508 SIL2-ready architecture |
| Connectivity | Ethernet with support for OPC UA, Modbus TCP, and Profibus DP |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MOVE-T |
| Instrument Type | Laboratory |
| Principle | Fourier Transform Near-Infrared (FT-NIR) |
| Design | Benchtop, Flow-Through Configuration |
| Sample Form | Liquid dairy matrices only |
| Compliance Context | Designed for routine QC in dairy processing per ISO 9622:2013, IDF 141:2000, and AOAC Official Method 972.16 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MPA III |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Near-Infrared Spectroscopy |
| Wavelength Range | 12500–3600 cm⁻¹ |
| Scan Speed | 8 scans/sec at 8 cm⁻¹ resolution |
| Data Sampling Interval | 2 cm⁻¹ |
| Sampling Modes | Diffuse Reflectance, Transmission, Diffuse Transmission, Fiber-Optic Probe |
| Chemometrics Software | OPUS |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TANGO |
| Instrument Type | Laboratory |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 11,500–4,000 cm⁻¹ |
| Scan Speed | 8 scans/sec |
| Data Sampling Interval | 4 cm⁻¹ |
| Measurement Modes | Diffuse Reflectance / Transmission |
| Chemometrics Software | OPUS |
| Brand | BUCHI |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | X-One (One-Six) |
| Instrument Type | In-line |
| Operating Principle | Real-time in-process spectroscopy with fiber-optic coupling |
| Wavelength Range | 900–1700 nm (standard advanced configuration) |
| optional dual-range | 350–920 nm (VIS) and 950–1750 nm (NIR) |
| Scan Rate | 100 spectra per second |
| Spectral Sampling Interval | 3.2 nm |
| Measurement Modes | Diffuse Reflectance / Transmission |
| Chemometrics Software | SX-Plus |
| Detector | Diode Array |
| Optical Spot Diameter | 30–40 mm |
| Imaging System | Integrated HD CCD camera, 80 µm spatial resolution in visible range |
| Light Source | Dual tungsten-halogen lamps, MTBF 18,000 h (2 × 9,000 h) |
| Environmental Rating | IP65/IP67 |
| Explosion-Proof Option | ATEX/IECEx certified (Ex II 1/2D ta tb IIIC T80°C |
| Dimensions (W×D×H) | 220 × 220 × 135 mm |
| Weight | 6–7 kg |
| Operating Temperature | −10°C to +70°C |
| Ambient Temperature Range | −10°C to +40°C |
| Relative Humidity | <90% RH, non-condensing |
| Vibration Resistance | 0.2 g (0.1–150 Hz) |
| Process Interface Pressure Rating | 30 bar at flange mounting point |
| Power Supply | 110/220 V AC ±20%, 50/60 Hz, 30 W |
| Housing Material | Nickel-plated stainless steel, aluminum heat sink, NBR sealing |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | NIRFlex N-500 |
| Instrument Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 10000–4000 cm⁻¹ (1000–2500 nm) |
| Scan Speed | 2–4 scans/sec |
| Data Sampling Interval | 4 cm⁻¹ |
| Measurement Modes | Diffuse Reflectance / Transmission / Transflection |
| Chemometrics Software | NIRCal |
| Interferometer Type | TeO₂ Wedge Polarization Interferometer |
| Spectral Resolution | 8 cm⁻¹ |
| Wavenumber Accuracy | ±0.2 cm⁻¹ |
| SNR | 10,000 (at 16 scans) |
| Detector | Temperature-Controlled InGaAs |
| A/D Converter | 24-bit |
| Light Source Lifetime | 12,000 h (dual tungsten halogen lamps) |
| Dimensions | 450 × 550 × 250 mm |
| Weight | 25 kg |
| Operating Environment | 5–35 °C, RH < 80% at ≤31 °C (derating to 67% at 35 °C), altitude ≤2500 m |
| Power Supply | 100–230 V ±10%, 50/60 Hz, <350 W |
| Communication Interface | Ethernet (TCP/IP), 100 Mbit/s |
| IP Rating | IP20 |
| Pollution Degree | 2 |
| Overvoltage Category | II |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Instrument Type | Benchtop FT-NIR Spectrometer |
| Model | NIRMaster |
| Spectral Range | 10000–4000 cm⁻¹ |
| Resolution | 8 cm⁻¹ |
| Scan Speed | 2–4 scans/sec |
| Data Sampling Interval | 4 cm⁻¹ |
| Measurement Modes | Diffuse Reflectance / Transflectance |
| Interferometer Type | Polarization Interferometer |
| Wavenumber Accuracy | ±0.2 cm⁻¹ |
| SNR | 10,000 (peak-to-peak, baseline-corrected, 5600–6000 cm⁻¹) |
| Detector | Thermoelectrically Cooled Extended-Range InGaAs |
| Light Source | Dual Halogen Lamp Module (MTBF: 12,000 h) |
| Laser | HeNe, 632.992 nm |
| Operating Temperature | 5–35 °C |
| Relative Humidity | <80% at ≤31 °C (linearly decreasing to 67% at 35 °C) |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz, 150 W |
| Enclosure Material | Food-Grade PMMA or Stainless Steel |
| IP Rating | IP54 (optional IP65) |
| Dimensions (W×H×D) | 360 × 420 × 540 mm |
| Weight | ~43 kg (NIRMaster), ~49 kg (NIRMaster Pro) |
| Chemometrics Software | NIRCal |
| Sample Handling | Easy-Spin magnetic rotation stage for heterogeneous samples |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ProxiMate |
| Instrument Type | Laboratory |
| Measurement Principle | Grating-based non-scanning spectrometer with diode array detector |
| Wavelength Range | 400–1700 nm |
| Scan Speed | 10 ms |
| Data Sampling Interval | 10 nm (visible), 7 nm (NIR) |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | Autocal |
| IP Rating | IP69 |
| Weight | 23 kg |
| Dimensions (W × D × H) | 260 × 435 × 500 mm |
| Power Consumption | 60 W |
| Operating Frequency | 50/60 Hz |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80 % (at ≤31 °C) |
| Storage Temperature | ≤45 °C |
| Altitude Limit | ≤2000 m |
| Measurement Time | Configurable, default 15 s |
| Optical Configuration Options | Standard NIR only |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ProxiScout |
| Instrument Type | Portable |
| Operating Principle | MEMS-based Micro-Electro-Mechanical Systems NIR Spectroscopy |
| Wavelength Range | 1350–2550 nm |
| Scan Speed | 2 seconds per scan |
| Measurement Mode | Reflectance |
| Chemometrics Software | EigenVector |
| Weight | 1 kg |
| Ingress Protection Rating | IP65 |
| Battery | Dual user-replaceable 18650 rechargeable cells |
| Battery Life | ~800 scans (2 s/scan) |
| Wireless Connectivity | Bluetooth v4.2 BLE |
| Optical Spot Diameter | ~10 mm |
| Charging Port | USB-C |
| Typical Signal-to-Noise Ratio | 2000:1 |
| Spectral Resolution | 16 nm |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Calorsito |
| Price Range | USD 70,000–140,000 |
| Instrument Type | Portable |
| Application Domain | Academic & Research Laboratories (Universities, Institutes) |
| Operating Principle | Photothermal Infrared Imaging Spectroscopy |
| Wavelength Range | 400–950 nm (7 discrete LED wavelengths: 400, 460, 525, 660, 730, 840, 950 nm) |
| Scan Speed | 1 sample per minute |
| Data Sampling Interval | Not applicable (single-shot thermal transient acquisition) |
| Sample Mode | Contactless, non-contact reflective/transmissive mode |
| Chemometrics Software | Integrated Calorsito Analyze Suite (PCA, PLS regression, spectral unmixing) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory-grade NIR Spectrometer |
| Model | CA-HM |
| Optical Design | Grating Scanning System |
| Wavelength Range | 780–2526 nm |
| Scan Speed | 100 scans per minute |
| Data Sampling Interval | 1 s |
| Measurement Modes | Reflectance & Transmission |
| Chemometric Algorithm | Peak Cross-Correlation Method |
| Application Scope | Academic Research, Food Quality Control, Nutrition Labeling, R&D Laboratories |
| Brand | CRAIC |
|---|---|
| Origin | USA |
| Model | 20/30PV™ |
| Wavelength Range | 200–2100 nm |
| Minimum Scan Speed | 4 ms |
| Spatial Sampling Interval | 1 µm |
| Measurement Mode | Automated |
| Software | LambdaFire™ |
| Detector Type | TE-Cooled Array Detectors |
| Sample Stage | Precision Motorized with Sub-Micron Positioning |
| Polarization Capability | Full UV-Vis-NIR Polarimetric Imaging |
| Optional Modules | Apollo™ Raman, rIQ™ Refractive Index Mapping, Spectral Surface Imaging |
| Brand | CRAIC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UVM-1 |
| Instrument Type | Laboratory |
| Operating Principle | Grating-based, Non-scanning Array Detector |
| Wavelength Range | 200–2500 nm |
| Acquisition Speed | 250 spectra/sec |
| Data Sampling Interval | User-selectable |
| Sample Handling | Automated |
| Chemometrics Software | LambdaFire |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 1330 |
| Instrument Type | Portable |
| Detection Principle | Grating-scanning NIR spectroscopy with InGaAs detector |
| Measurement Time | ≤3 s per sample |
| Sample Forms | Granular, flake, and powdered materials |
| Connectivity | Wi-Fi, USB, Bluetooth (optional) |
| Power Supply | AC adapter or optional rechargeable Li-ion battery |
| Compliance | Supports ASTM E1655, ISO 12099, and GB/T 37878–2019 for NIR calibration transfer and performance validation |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 1340 |
| Instrument Type | Online NIR Spectrometer |
| Optical Design | Grating Scanning |
| Application Domain | Feed Production, Grain & Oil Processing, Brewing Industry |
| Measurement Principle | Diffuse Reflectance / Transmission NIR Spectroscopy |
| Sampling Interface | Customizable Process Probe |
| Connectivity | Ethernet, Fiber Optic, 4–20 mA Analog Output |
| Enclosure Rating | IP65 |
| Data Acquisition Rate | 5 Hz |
| Alarm Logic | Dual-level (Primary/Secondary) Thresholding |
| Software Integration | C# DLL for Custom SCADA/MES Integration |
| Built-in Reference Standard | Yes |
| Self-Diagnostic & Auto-Calibration | Yes |
| Compliance Context | Designed for GLP-aligned process analytical technology (PAT) deployment |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 1350 |
| Instrument Type | Portable |
| Wavelength Range | 1000–1800 nm |
| Weight | 6 kg |
| Power Supply | DC 19 V or Built-in Rechargeable Lithium Battery |
| Display | Integrated Full-Color LCD with Chinese UI |
| Data Storage | Internal High-Capacity Flash Memory |
| Connectivity | USB 2.0 |
| Software | RIMP (Remote Instrument Management Platform) |
| Sample Interface | Interchangeable Probes for Solids, Powders, Pastes, Tablets, and Liquids |
| Diagnostic Function | Onboard Reference Material & Self-Diagnostic Routine |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 1360 |
| Instrument Type | Portable |
| Compliance | Meets GB/T and ASTM D7462/D8073 for fuel analysis |
| Operating Temperature Range | −5 °C to 50 °C |
| Temperature Control Range | 15–60 °C |
| Temperature Stability | ±0.2 °C |
| Measurement Time | ≤10 s per sample |
| Software Interface | Fully localized Chinese GUI with integrated modeling, calibration, and data management modules |
| Connectivity | Ethernet and Wi-Fi enabled for NIR network integration, remote diagnostics, model updates, and instrument health monitoring |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory-Based NIR Spectrometer |
| Model | EXPEC 1360A |
| Application Scope | Fuel Quality Analysis (Gasoline, Diesel, Biofuels), Onboard & At-Line Deployment |
| Optional Accessories | U-Tube Oscillating Density Meter (±0.0005 g/cm³), Rechargeable Battery Pack (8 h runtime) |
| Compliance Framework | Designed for ASTM D2887, D5292, D7467, ISO 20846, and GB/T 28768-2012 alignment |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EXPEC 1370 |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Detection Principle | Diffuse Reflectance NIR Spectroscopy |
| Typical Measurement Time | ≤10 s per sample |
| Detector | InGaAs Array |
| Optical System | Fixed Grating Monochromator |
| Wavelength Range | 900–1700 nm (standard configuration) |
| Compliance | Designed for GLP-compliant laboratory environments |
| Software | EXPEC NIR Analysis Suite with User Role Management (Admin/Operator/Reviewer) |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 1380 |
| Pricing | Upon Request |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Detector | TEC-Cooled InGaAs |
| Optical System | Holographic Digital Grating |
| Sample Interface | Rotating Sample Carousel (Ø180 mm standard) |
| Measurement Principle | Diffuse Reflectance NIR Spectroscopy (900–1700 nm) |
| Data Acquisition Time | ≤10 s per sample |
| Built-in Computing | Integrated Industrial PC |
| Compliance Support | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready audit trail capability |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | FoodScan 2 |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Design | Grating Scanning System |
| Wavelength Range | 400–1100 nm |
| Sample Throughput | 15–25 seconds per sample |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Transmission and Reflectance |
| Chemometric Software Engine | Artificial Neural Network (ANN) Calibration |
| Regulatory Certification | AOAC Official Method of Analysis™ 983.18 |
| Application Scope | Raw and processed meat, poultry, and aquatic products (porcine, bovine, avian, etc.) |
| Key Analytes | Fat, Protein, Moisture, Collagen, Salt (Cl⁻ basis), Lean Meat Content |
| Optional Extensions | Saturated Fatty Acids, Ash, Sodium-based Salt, Water Activity, Color Parameters |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Infratec Grain & Flour |
| Instrument Type | Laboratory Near-Infrared Spectrometer |
| Principle | Grating-based Scanning Transmission NIR |
| Wavelength Range | 570–1100 nm |
| Scan Speed | 60 scans/sec |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | ANN (Artificial Neural Networks), PLS (Partial Least Squares) |
| Path Length Control | Motorized, 6–33 mm auto-adjustable |
| Subsample Capacity | 1–30 (standard: 10) |
| Analysis Time | 60 s (10 subsamples, including bulk density) |
| Compliance | EN 15948, IP54 dust- and splash-resistant enclosure |
| Patents | US 4,944,589 |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Infratec™ Sofia |
| Instrument Type | Portable Near-Infrared Spectrometer |
| Wavelength Range | 850–1050 nm |
| Measurement Mode | Transmission NIR |
| Analysis Time | ~3 minutes for 10 subsamples |
| Dimensions (W × D × H) | 255 × 390 × 295 mm |
| Weight | 9 kg |
| Operating Temperature | 0–45 °C |
| Storage Temperature | −20–70 °C |
| Relative Humidity | <93% RH (non-condensing), up to 100% cyclic |
| Power Supply | 100–240 V AC, 50–60 Hz, Class I with earth grounding |
| EMC Environment | Light industrial, agricultural & mobile machinery |
| Sample Preparation | None required (whole-grain analysis) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | MeatScan |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | Grating-based non-scanning array detector |
| Wavelength Range | 850–1050 nm |
| Scan Time | 45 seconds per sample (including 15 subsamples) |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Artificial Neural Network (ANN)-based calibration |
| Sample Form | Homogenized meat mince (pork, poultry, beef, lamb) |
| Output Parameters | Fat content (%), Moisture content (%) |
| Weight | 12 kg |
| Compliance | Designed for GLP-compliant environments |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS DA1650 |
| Instrument Type | Laboratory Benchtop |
| Optical Principle | Grating-based Diode Array Scanning |
| Wavelength Range | 1100–1650 nm |
| Scan Time | 1 minute per spectrum |
| Data Sampling Interval | 0.5 nm |
| Measurement Modes | Diffuse Reflectance, Transmission (for liquids) |
| Chemometrics Software | WinISI |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS DS3 F |
| Instrument Type | Laboratory NIR Spectrometer |
| Optical Principle | Grating Scanning |
| Wavelength Range | 850–2500 nm |
| Scan Speed | <1 minute per sample |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | WinISI with Artificial Neural Network (ANN) algorithms |
| Enclosure Rating | IP65 |
| Cooling System | Closed-Loop Liquid Cooling |
| Sample Interface | RFID-Enabled Sample Cups |
| Factory Calibration Strategy | Pre-Standardized, Inter-Instrument Transferable Calibration |
| Language Options | English or Chinese UI & Network Management Software |
| Compliance Support | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready audit trail capabilities in WinISI |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS DS3 |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 400–2500 nm |
| Scan Speed | <1 minute per sample |
| Data Sampling Interval | 0.5 nm |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | WinISI with Artificial Neural Network (ANN) algorithms |
| Enclosure Rating | IP65 |
| Cooling System | Closed-Loop Liquid Cooling |
| Sample Identification | RFID-Enabled Sample Cups |
| Factory Calibration Strategy | Inter-instrument Transferable Standardization |
| Language Options | English or Chinese GUI (configurable) |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | NIRS™ DS2500 L |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 400–2500 nm |
| Scan Time | <40 s per sample |
| Data Sampling Interval | 10 s |
| Measurement Mode | Transmission (for liquids) |
| Chemometrics Software | WinISI |
| IP Rating | IP54 |
| Temperature Control | Automatic, Closed-Loop Sample Thermal Regulation |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | ProFoss™ 2 Online Feed Analyzer |
| Instrument Type | Online Near-Infrared Spectrometer |
| Optical Principle | Grating-based non-scanning diode array detector |
| Wavelength Range | 1100–1650 nm |
| Analysis Speed | Real-time |
| average analysis time per result | 2–3 seconds |
| Sampling Interval | Real-time |
| Measurement Mode | NIR transmission/reflection (process-integrated) |
| Chemometrics Software | ISIscan NOVA™ Instrument Control Software |
| Sample Interface | Direct-coupled flow-through window, no bypass required |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | ProFoss™ 2 Online Soybean Meal Analyzer |
| Instrument Type | Online Near-Infrared Spectrometer |
| Principle | Grating-based diode array (non-scanning) NIR spectroscopy |
| Wavelength Range | 1100–1650 nm |
| Analysis Time per Result | 2–3 seconds (real-time) |
| Sampling Mode | Diffuse reflectance and/or transmission |
| Chemometrics Software | ISIscan NOVA™ Instrument Control |
| Data Acquisition Interval | 2–3 seconds (real-time) |
| Compliance Ready | Designed for integration with industrial process control systems (OPC UA/DA), supports audit-ready data logging per GLP/GMP-aligned workflows |