| Key | Brand: Schmidt + Haensch |
|---|---|
| Origin | Germany |
| Model | ATR-P |
| Type | Inline Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 1.32000–1.54000 RI / 0–100 % Brix |
| Resolution | 0.00001 RI / 0.01 % Brix |
| Accuracy | ±0.00002 RI / ±0.02 % Brix |
| Repeatability | ±0.00001 RI / ±0.01 % Brix |
| Temperature Range (Sample) | +5 to +50 °C |
| Temperature Accuracy | ±0.03 °C |
| Wavelength | 589 nm (LED with interference filter) |
| Prism Material | Sapphire |
| Display | 7″ TFT touchscreen (800 × 480 px, 16-bit color) |
| Interface | 2× RS232, 3× USB-A, 1× USB-B, 1× Ethernet |
| Compliance | ASTM E1220, ICUMSA Method GS2/3-12, USP <851>, Ph. Eur. 2.2.29, GLP/GMP-ready |
| Brand | SCHMIDT + HAENSCH |
|---|---|
| Origin | Germany |
| Model | Coloromat 100 |
| Optical Principle | Single-beam spectrophotometry |
| Spectral Range | 420–900 nm |
| Fixed Wavelengths | 340, 420, 720 nm |
| Customizable Wavelengths | up to 6 additional (340–900 nm), total ≤9 |
| Extinction Accuracy | ±0.020 (340 & 420 nm), ±0.010 (720 nm), ±0.020 (other wavelengths) |
| ICUMSA Range | 0–16.000 IU |
| ICUMSA Accuracy | ±10% (<20 IU), ±5% (>20 IU) |
| Extinction Resolution | 0.001 |
| Light Source | 12 V / 20 W halogen lamp |
| Display | Graphical touchscreen interface |
| Interface | RS232C |
| Operating Temperature | 10–40 °C |
| Power Supply | 85–265 V AC, 47–63 Hz |
| Language Support | English & German (others on request) |
| Internal Method Storage | 250 pre-programmed methods (ROM), up to 230 user-defined methods (RAM) |
| Data Storage Capacity | 2970 measurements, 99 sample IDs |
| Compliance | GLP/GMP-compliant data handling, audit-trail-ready operation |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | DHR |
| Type | Digital handheld refractometer |
| Temperature control | Yes (ATC) |
| Digital display | Yes (5-digit LCD) |
| Measurement range | 0–95 °Brix / 1.3300–1.5400 RI |
| Resolution | 0.1 °Brix / 0.0001 RI |
| Accuracy | ±0.2 °Brix / ±0.0003 RI |
| Operating sample temperature | 5–60 °C |
| Ambient temperature range | 5–40 °C |
| ATC compensation range | 5–70 °C |
| IP rating | IP65 |
| Compliance | CE, RoHS |
| Power | 2×AAA batteries |
| Dimensions (L×W×H) | 115×54×30 mm |
| Weight | 85 g (without batteries) |
| Prism material | Optical glass |
| Brand | SCHMIDT + HAENSCH |
|---|---|
| Origin | Germany |
| Model | Polartronic V |
| Sample Tube Length | up to 200 mm |
| Measurement Range | ±360° / ±259°Z |
| Accuracy | ±0.005° / ±0.015°Z |
| Resolution | 0.001° / 0.01°Z |
| Repeatability | ±0.005° / ±0.015°Z |
| Wavelength Options | 589 nm (Na-D), 882 nm, or dual-wavelength (589 & 882 nm) |
| Light Source | Long-life LED |
| Temperature Control | External Peltier or water bath (18–40 °C, ±0.03 °C accuracy) |
| Optical Density Range | Up to OD 5 |
| Response Time | ~4 s |
| Display | 7" TFT touchscreen (800×480, 16-bit color) |
| Interfaces | RS232 ×1, USB-A ×4, USB-B ×1, Ethernet ×1, Analog output, optional WLAN/LAN |
| Compliance | GLP/GMP, FDA 21 CFR Part 11 ready |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principles | Conductivity-based Ash Determination, Photometric Colorimetry at 420 nm (ICUMSA), Nephelometric Turbidity |
| Accuracy | ±1 IU (Color, ≤30 IU), ±10% (Turbidity), ±0.001% (Ash), ±0.1 °Brix (Brix) |
| Compliance | ICUMSA Method GS5/8/9-1, ASTM D1209, ISO 7027, USP <731> |
| Automation Level | Fully Automated Sample Handling, Dilution, Filtration, Measurement, and System Rinse |
| Software Integration | LIMS-ready with audit-trail-capable data acquisition, FDA 21 CFR Part 11–compliant optional module |
| Sample Throughput | ~3 samples/hour |
| Sample Format | Pre-weighed white sugar solids (barcoded) |
| Brand | Schmidt + Haensch |
|---|---|
| Origin | Germany |
| Model | Saccharoflex 2020 |
| Measurement Principle | Reflectance Photometry |
| Wavelengths | 495 nm and 620 nm |
| ICUMSA Method Compliance | GS2-11 (1994) and GS2-13 (1994) |
| Range | 0–19.99 ICUMSA Color Units (CU) |
| Resolution | 0.01 CU |
| Accuracy | ±0.15 CU |
| Repeatability | ±0.15 CU |
| Light Source | 12 V / 20 W Halogen Lamp |
| Display | Backlit LCD |
| Interface | RS-232C and USB-B |
| Operating Temperature | 10–40 °C |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Language Support | English and German |
| Calibration Standards | Brunswick ceramic reference tiles (CU 0 and CU 6 recommended) |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | Saccharomat V |
| Product Type | Automatic Polarimeter |
| Temperature Control | Yes (external or Peltier-based) |
| Digital Display | Yes |
| Light Source | LED |
| Measurement Range | −35 to +105 °Z |
| Measurement Resolution | 0.01 °Z |
| Accuracy | ±0.01 °Z |
| Photometric Sensitivity | up to OD 5 |
| Response Time | ~4 s |
| Wavelength Options | 587.6 nm (D-line), 882.6 nm (NIR), or dual-wavelength configuration |
| Temperature Control Range (with thermostatted cell) | 18–40 °C |
| Temperature Accuracy (with T-Cell) | ±0.03 °C |
| Repeatability | 0.01 °Z |
| Optical Path Length | up to 200 mm |
| Display | 7″ TFT touchscreen (800 × 480 px, 16-bit color) |
| Interfaces | RS232 ×1, USB-A ×4, USB-B ×1, Ethernet ×1, Analog output, optional WLAN/LAN |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–compatible software architecture |
| Brand | SCHMIDT + HAENSCH |
|---|---|
| Origin | Germany |
| Model | UniPol V |
| Sample Measurement Range | ±360° / ±259°Z |
| Angular Accuracy | ±0.005° / ±0.02°Z |
| Angular Resolution | 0.001° / 0.01°Z |
| Wavelength | 589 nm (LED) |
| Temperature Control | External Circulating Bath Interface |
| Display | Graphical LCD (16×16 characters) |
| Interfaces | 2× RS-232, 1× Parallel, PS/2, USB*, Ethernet* |
| Compliance | ASTM E1254, USP <781>, Ph. Eur. 2.2.7, FDA 21 CFR Part 11 (with optional audit trail software) |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | VariPol |
| Product Type | Automated Polarimeter |
| Temperature Control | Peltier-regulated |
| Display | Digital Touchscreen |
| Light Source | LED with Interference Filter |
| Temperature Range | 10–40 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Optical Rotation Accuracy | ±0.01° (VariPol C), ±0.005° (VariPol B) |
| Optical Rotation Resolution | 0.001° |
| Repeatability | ±0.01° (VariPol C), ±0.005° (VariPol B) |
| Wavelength | Standard 589 nm (Na-D line), customizable between 365–882 nm |
| Measurement Time | 6–8 s |
| Optical Path Length Compatibility | Up to 100 mm |
| Detector Dynamic Range | OD 3 |
| Interface Options | 3× USB, 1× RS-232, 1× Ethernet (LAN), optional Modbus, CAN bus, WLAN |
| Dimensions | 430 × 300 × 160 mm (W × D × H) |
| Compliance | 21 CFR Part 11, USP <781>, Ph. Eur. 2.2.7, JP 2.03 |
| Brand | Schmidt + Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | VariRef A / B / C |
| Product Type | Inline Refractometer |
| Temperature Control | Dual-isolated Peltier system |
| Digital Display | 5" or 7" capacitive touchscreen (800 × 480 px, 16-bit color) |
| Measurement Range | 1.320000–1.580000 RI / 100% Brix (VariRef A) |
| Accuracy | ±0.00002 RI / ±0.02% Brix |
| Resolution | 0.00001 RI / 0.01% Brix |
| Repeatability | ±0.00001 RI / ±0.01% Brix |
| Temperature Control Range | +5°C to +100°C (VariRef B, customizable) |
| Temperature Accuracy | ±0.03°C |
| Prism Material | Sapphire (A & C), Sapphire/YAG (B) |
| Light Source | LED with integrated 589 nm interference filter |
| Compliance | ASTM D1218, ISO 2160, USP <781>, Ph. Eur. 2.2.12, ICUMSA Methods GS2/3-13, AOAC 932.12, DIN 51757, FDA 21 CFR Part 11 (software-enabled), GLP/GMP audit trail support |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Origin | Germany |
| Model | Ash-Color-Turbidity Analyzer |
| Measurement Principles | Dual-wavelength photometric absorption (color), differential absorption ratio (turbidity), conductometric ash estimation (ICUMSA-compliant), refractometric Brix |
| Accuracy | ±1 IU (color, ≤30 IU) |
| Sample Prep Time | <60 s |
| Compliance | ICUMSA Method GS4/8-12 (sugar industry), ISO 7027 (turbidity), ASTM D1209 / D5391 (color), USP <731> (clarity and turbidity) |
| Brand | SCHMIDT+HAENSCH (S+H) |
|---|---|
| Country of Origin | Germany |
| Model Series | ATR ST / ST plus / ST T plus |
| Refractive Index Range | 1.3320–1.5320 / 1.30000–1.54000 / 1.28000–1.54000 RI |
| Brix Range | 0–95 / 0–100 / 0–100 % |
| Resolution | RI 0.0001 / 0.00002 / 0.00001 |
| Accuracy | RI ±0.0001 / ±0.00005 / ±0.00003 |
| Temperature Control Range | +5 °C to +50 °C |
| Light Source | 589 nm LED |
| Display | 16×16 character LCD |
| Auto Temperature Compensation | Yes |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | ATR W1 / W1 Plus / W2 / W2 Plus |
| Refractive Index Range | RI 1.33200–1.53200 (W1/W1 Plus), RI 1.33200–1.70000 (W2/W2 Plus) |
| Brix Range | 0–95% (W1/W1 Plus), 0–100% (W2/W2 Plus) |
| Resolution | RI 0.00002 / Brix 0.02 (W1/W1 Plus), RI 0.00001 / Brix 0.01 (W2/W2 Plus) |
| Accuracy | ±0.00004 RI / ±0.04 Brix (W1/W1 Plus), ±0.00002 RI / ±0.02 Brix (W2/W2 Plus) |
| Temperature Control | Peltier-controlled sapphire prism, operating range +10°C to +80°C |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | Coloromat-S |
| Wavelength Range | 340–900 nm |
| Standard Filters | 340 nm, 420 nm, 720 nm |
| Optional Wavelengths | Up to 9 user-selectable wavelengths |
| Wavelength Calibration | Automatic |
| Light Source | 12 V / 20 W halogen lamp |
| Detector | Silicon photodiode |
| Display | Graphical color touchscreen interface |
| Sample Cell Pathlength | Up to 100 mm (flow-through or static cuvette) |
| Measurement Modes | Transmittance, absorbance, extinction, and CIE-based color values (e.g., CIELab, EBC, ICUMSA) |
| Compliance | GLP/GMP-ready with audit trail support (user login, method storage, data timestamping) |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | H532 |
| Measurement Range | ±360° / 259°Z |
| Resolution | 0.0001° / 0.01°Z |
| Accuracy | ±0.002° / ±0.01°Z |
| Repeatability | ±0.001° / ±0.01°Z |
| Sensitivity | OD 5 |
| Measurement Time | <4 s (full range, uniform performance) |
| Sample Cell Options | 10, 50, 100, 200 mm standard tubes + micro cells |
| Light Sources | Sodium lamp (589.3 nm), Mercury lamp (365 nm, 404.7 nm, 435.8 nm, 546.1 nm), or high-stability LED (lifetime >100,000 h) |
| Wavelength Options | Up to 5 discrete wavelengths from 365 nm to 589 nm |
| Compliance | ICUMSA, OIML R 102, Australian Standard K 157, USP <781>, Ph. Eur. 2.2.7, JP 2.05, FDA 21 CFR Part 11 (audit trail & electronic signature ready), GLP/GMP traceable operation |
| Brand | Schmidt+Haensch |
|---|---|
| Origin | Germany |
| Model | Polartronic N/M TOUCH |
| Measurement Range | ±360° / ±259°Z (N) and ±360° / ±259°Z (M) |
| Resolution | 0.01° / 0.05°Z (N), 0.001° / 0.01°Z (M) |
| Accuracy | ±0.01° / ±0.05°Z (N), ±0.005° / ±0.015°Z (M) |
| Repeatability | ±0.01° / ±0.05°Z (N), ±0.005° / ±0.015°Z (M) |
| Wavelength Options | 405, 435, 546, 578, 589, 633, 882 nm (fixed or dual selectable) |
| Response Time | <4 s across full range |
| Temperature Range | 0–99 °C |
| Temp. Accuracy | ±0.03 °C |
| Temp. Resolution | 0.01 °C |
| Light Source | Long-life LED (>100,000 h) with optical filters |
| Detector | Integrated photoelastic modulator (PEM)-based polarimetric sensor |
| Compliance | OIML R 107, ASTM E1254, USP <781>, EP 2.2.7, JP 2.05, ICUMSA Methods, Australian Standard K157 |
| Software | GLP/GMP-compliant data management with 21 CFR Part 11 audit trail capability |
| Display | 7-inch capacitive TFT touchscreen |
| Housing | Rugged anodized aluminum enclosure |
| Calibration | PTB-certified quartz control plates included |
| Sample Compatibility | Standard 100 mm/200 mm cells |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Automated Liquid Dispensing System |
| Pricing | Upon Request |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | Saccharomat® |
| Measurement Range | –35°Z to +105°Z |
| Resolution | 0.01°Z |
| Accuracy | ±0.02°Z |
| Repeatability | ±0.01°Z |
| Optical Density Limit | OD 5 (Transmittance down to 1×10⁻⁵%) |
| Measurement Time | <4 s |
| Cell Length Options | 50 mm, 100 mm, 200 mm |
| Light Source | LED |
| Wavelengths | 587 nm and/or 882 nm |
| Compensation Principle | Quartz wedge-based optical nulling |
| Calibration | Factory-calibrated |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | UniPol L-Series |
| Product Type | Automatic Polarimeter |
| Temperature Control | Peltier & optional water bath |
| Digital Display | Yes |
| Light Source | LED (589 nm, with 405 nm option on L 2000) |
| Measurement Range | ±360°, ±259°Z |
| Resolution | 0.001° / 0.01°Z (L 2000), 0.01° / 0.02°Z (L, L 1000) |
| Accuracy | ±0.005° / ±0.02°Z (L 2000), ±0.01° / ±0.03°Z (L, L 1000) |
| Temperature Range | 0–99 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.03 °C |
| Compliance | USP <781>, Ph. Eur. 2.2.7, ASTM E1254, GLP/GMP, FDA 21 CFR Part 11 (with Aquisys 2008 software), PTB-certified quartz calibration cells |
| Brand | Schmidt+Haenscher |
|---|---|
| Origin | Germany |
| Model | Saccharoflex 2000 |
| Measurement Range | 0–19.99 CTU |
| Resolution | 0.01 CTU (low range), 0.05 CTU (high range) |
| Optical Wavelengths | 495 nm and 620 nm |
| Display | 30-character LCD |
| Interface | 4-button membrane keypad |
| Compliance | ICUMSA Method GS2/3-13 (2013) for sucrose color determination |
| Sample Form | Solid, granular, or powdered materials (e.g., crystalline sugar, ceramic powders, cement clinker) |
| Calibration Standards | Certified CTU reference standards (0 CTU and 6 CTU, sugar- or ceramic-matrix matched) |
| Brand | Schmidt+Haensh (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | ATR SW / ATR SW Plus |
| Refractive Index Range | RI 1.33200–1.53200 (ATR SW), RI 1.30000–1.54000 (ATR SW Plus) |
| Brix Range | 0–95% (ATR SW), 0–100% (ATR SW Plus) |
| Resolution | RI 0.00002 / 0.00001, Brix 0.02 / 0.01 |
| Accuracy | RI ±0.00004 / ±0.00002, Brix ±0.04 / ±0.02 |
| Temperature Control Range | +5 °C to +50 °C |
| Prism Material | Sapphire |
| Light Source | LED with 589 nm interference filter |
| Display | 16×16 character LCD |
| Data Interface | Parallel port and RS-232C |
| Brand | Schmidt+Haensh (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | ATR-B/F new |
| Type | Benchtop Refractometer |
| Temperature Control | Built-in Peltier |
| Digital Display | 7" TFT Touchscreen |
| Measurement Range | 1.32000–1.7000 RI / 0–100% Brix |
| Resolution | 0.00001 RI / 0.01% Brix |
| Accuracy | ±0.00002 RI / ±0.02% Brix |
| Light Source | LED with 589 nm interference filter (>100,000 h lifetime) |
| Compliance | ASTM, ISO, DIN, USP, ICUMSA, FDA 21 CFR Part 11 ready (optional software), GLP/GMP compliant |
| Brand | Schmidt+Haensch (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | DSR-λ |
| Wavelengths | 400, 436, 486, 546, 589, 656, 707 nm |
| Refractive Index Range | 1.33200–1.70000 (at 589 nm) |
| Resolution | 0.00001 RI unit & 0.01°C |
| Accuracy | ±0.0001 RI (at 20°C) |
| Temperature Control | Peltier-based |
| Operating Temperature Range | +18°C to +30°C (extended ranges available on request) |
| Light Source | Stable LED array with seven discrete wavelengths |
| Compliance | ASTM standard methods built-in |
| Sample Compatibility | Liquids, solutions, transparent or slightly turbid homogeneous samples |
| Brand | Schmidt+Haensh (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | Portable Refractometer |
| Measurement Range | 0.0–60.0 °Brix or 45–90 °Brix |
| Resolution | 0.1 °Brix |
| Accuracy | ±0.2 °Brix |
| Measurement Time | 2 s |
| Sample Volume | >0.1 mL |
| Operating Temperature | +10 °C to +70 °C |
| Measured Temperature Range | up to 100 °C |
| Power Supply | Battery-operated |
| Units | °Brix |
| Brand | Schmidt+Haensh (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | Portable Handheld Refractometer |
| Measurement Ranges | Brix (4 selectable ranges), Urine (0–12 g/dL), Salt (0–28%), Alcohol (0–32 °Brix |
| Operating Temperature | +10°C to +40°C |
| Automatic Temperature Compensation (ATC) for Brix | +10°C to +30°C |
| Weight | 0.25 kg |
| Compliance | Designed per ISO 21749:2022 (Refractometric determination of soluble solids), ASTM D1218, USP <781> |
| Brand | Schmidt+Haensh (S+H) |
|---|---|
| Country of Origin | Germany |
| Model | Visual Disc Polarimeter |
| Measurement Range | ±180° |
| Sensitivity | 0.1° |
| Accuracy | ±0.1° |
| Light Source | Halogen Lamp or Sodium Spectral Lamp |
| Wavelength | 546 nm or 589 nm |
| Sample Cell Length | Up to 200 mm |
| Cell Features | Bubble-trap or filter cup integrated |
| Accessories | Temperature-controlled and material-varied polarimetric cells (glass, quartz, stainless steel) |
| Brand | Schmidt+Haensch |
|---|---|
| Country of Origin | Germany |
| Model | Sugar Purity Analyzer |
| Measurement Principle | Combined Polarimetry and Refractometry |
| Accuracy (M-Series + DUR) | ±0.02°Z and ±0.02 Brix |
| Sensitivity (M-Series + DUR) | ±0.01°Z and ±0.01 Brix |
| Temperature Control | Optional Peltier-regulated sample cell holders |
| Compliance | ASTM E1258, ISO 5725, USP <781>, EN 13479, GLP/GMP-ready audit trail support in software |
| Brand | Accurion |
|---|---|
| Origin | Germany |
| Model Series | Atlas (Heavy-Duty Modular), Reactio Plus (Desktop) |
| Load Capacity | Atlas Module: 300–1000 kg/unit |
| Reactio Plus | 120–150 kg |
| Vibration Isolation Range | ≥1 Hz |
| Isolation Performance | ≥12 dB at 1 Hz |
| Module Dimensions (Atlas) | 240 × 240 × 110 mm |
| Application Target | High-Precision Optical Benches, Moving XY Stages, Audio Equipment, Electron Microscopy, Interferometry |
| Brand | ZOLIX |
|---|---|
| Model | APFP-GH |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Pricing | Available Upon Request |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | IX2 AIR SE |
| Operating Temperature | Uncooled |
| Measurement Method | Non-contact |
| Application | Temperature Measurement |
| Detector Type | Single-element infrared detector |
| Temperature Range | -20°C to +150°C, 100°C to 550°C |
| IR Resolution | 256 × 192 |
| Pixel Pitch | 12 µm |
| Spectral Band | 7.5–14 µm |
| NETD | <40 mK @ 25°C, F1.0 |
| Frame Rate | 25 Hz |
| Lens Focal Length | 3.2 mm |
| FOV | 56° × 42° |
| IFOV | 3.75 mrad |
| Focus | Fixed |
| Minimum Focus Distance | 0.3 m |
| Accuracy | ±2°C or ±2% of reading (whichever is greater) |
| Color Palettes | 7 |
| Image Analysis Modes | Spot, Max/Min, 3 Custom Points/Lines/Boxes |
| Connectivity | Wi-Fi (up to 8 m), Bluetooth, USB-C |
| Battery | 1050 mAh |
| Runtime | ~2 h |
| Charging | USB Type-C |
| Weight | ~130 g |
| Dimensions | 135.6 × 41 × 29.1 mm |
| IP Rating | IP54 |
| Drop Resistance | 2 m |
| Shock/Vibration | 25 g (IEC 60068-2-27), 2.5 g (IEC 60068-2-6) |
| Operating Temp | -10°C to +50°C |
| Humidity | 10–90% RH (non-condensing) |
| Storage Temp | -20°C to +60°C |
| Certifications | CE, RoHS, Metrological Verification |