Optical Measurement Instruments
Filter
Showing 361–390 of 793 results
| Brand | Gentec-EO |
|---|---|
| Origin | Canada |
| Model | PRONTO |
| Power Range | 0.5 W to 250 W |
| Display | Touchscreen Color LCD |
| Calibration Wavelengths | 248 nm – 12.5 µm (YAG band) and 10.6 µm (CO₂) |
| Data Storage | Internal memory with USB export |
| Interface | USB and RS-232 serial control |
| Mounting | Dual 8-32 threaded holes |
| Compliance | NIST-traceable calibration certificates supplied |
| Detector Type | Thermopile-based |
| Form Factor | Handheld, pocket-sized portable unit |
| Brand | TOP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | WSY-1 |
| Pricing | Upon Request |
| Brand | APE |
|---|---|
| Origin | Germany |
| Model | PulseCheck USB |
| Type | Scanning Autocorrelator for Ultrashort Laser Pulse Characterization |
| Wavelength Coverage | 200 nm – 2400 nm (configurable via optical modules) |
| Pulse Duration Range | 20 fs – 35 ps (dependent on module) |
| Scan Mechanism | Precision Linear Translation Stage with Real-Time Position Feedback |
| Detection Options | Photomultiplier Tube (PMT) and Photodiode (PD) |
| Interface | USB 2.0 with pulseLink Controller |
| Compliance | CE-marked, RoHS-compliant, Designed for GLP-Compatible Lab Environments |
| Software | Windows-based pulseView with TCP/IP support, Data Export (ASCII, CSV, HDF5), Trigger Synchronization (10 Hz – 50 kHz), FDA 21 CFR Part 11–Ready Audit Trail Optional |
| Brand | Gigahertz Optik |
|---|---|
| Origin | Shanghai, China |
| Distributor Type | Authorized Distributor |
| Country of Manufacture | Germany (designed & calibrated in Germany |
| Model | BTS256-EF |
| Measurement Range | 1–199,999 lx (illuminance), 360–830 nm (spectral range) |
| Spectral Bandwidth | 10 nm (CIE 214-compliant adaptive optical bandwidth correction) |
| Cosine Error | ≤3% (f₂) |
| Flicker Frequency Range | 0.25 Hz – 200 kHz |
| Integration Time | 5.2–30,000 ms |
| ADC Resolution | 12-bit |
| Power Supply | 5 V DC / 450 mA via USB |
| Temperature Compensation | Integrated thermistor for photodiode and spectrometer units |
| Calibration Uncertainty | ±2.2% (luminance), f₁′ ≤3% (with spectral correction), stray light <6×10⁻⁴ (LED-specific) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROCON2000 |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Imported |
| Model | Prosan8200 |
| Product Type | Online Turbidimeter |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.0001 NTU (adjustable) |
| Operating Temperature | 1–50 °C |
| Accuracy | ±2% of reading or ±0.02 NTU (≤40 NTU) |
| Response Time | 5–500 s (adjustable) |
| Light Source | 850 nm LED (7-year lifetime) |
| Display | Backlit LCD, multi-line |
| Sample Pressure | 1–200 psi (built-in pressure regulator preset to 15 psi) |
| Output Signal | Isolated 4–20 mA or RS-485 (MODBUS RTU protocol) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (250 VAC) |
| Ingress Protection | IP66 |
| Dimensions | 35 × 30 × 30 cm |
| Weight | 2.5 kg |
| Brand | TOP / TP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Classification | Domestic (China) |
| Model | GY-10 |
| Pricing | Upon Request |
| Brand | Top (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GY-13 |
| Pricing | Available Upon Request |
| Brand | Toppo (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GY-1A |
| Pricing | Upon Request |
| Brand | TOP / TP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GY-8 |
| Pricing | Available Upon Request |
| Brand | HACH |
|---|---|
| Origin | USA |
| Model | 1720E |
| Instrument Type | Benchtop Laboratory Turbidimeter |
| Measurement Range | 0.0001–9.9999 NTU and 10.000–99.999 NTU (auto-ranging) |
| Resolution | 0.0001 NTU (0–9.9999 NTU) |
| Accuracy | ±2% or ±0.02 NTU (whichever is greater) for 0–40 NTU |
| Repeatability | Better than ±1.0% of reading or ±0.002 NTU (whichever is greater) |
| Response Time | Step response, initial response ~75 seconds |
| Signal Averaging Options | 6, 30, 60, or 90 seconds (user-selectable |
| Sample Flow Rate | 200–750 mL/min |
| Operating Temperature | 0–50°C (single-sensor configuration) |
| Sample Temperature Range | 0–50°C |
| Analog Output | 0/4–20 mA (programmable over 0–100 NTU range) |
| Relay Outputs | Three SPDT relays (230 VAC, 5 A), configurable for alarm or control setpoints |
| Power Supply | 100–230 VAC, 50/60 Hz (auto-sensing) |
| Inlet Fitting | 1/4" NPT female + 1/4" compression fitting (included) |
| Drain Fitting | 1/2" NPT female + 1/2" hose barb (included) |
| Digital Communication Protocols | MODBUS RTU over RS-485 and RS-232 |
| Compliance Standards | Standard Method 2130B, USEPA Method 180.1, Hach Method 8195 |
| Enclosure Rating | NEMA-4X / IP66 |
| Dimensions (Controller) | 25.4 × 30.5 × 40.6 cm |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | 2100Q |
| Product Type | Portable |
| Measurement Range | 0–1000 NTU |
| Resolution | 0.01 NTU |
| Accuracy | ±2% of reading + stray light contribution |
| Stray Light | < 0.02 NTU (FNU) |
| Compliance | EPA Method 180.1 |
| Optical Principle | Ratio-based 90° scattered light detection with simultaneous transmission compensation |
| Ingress Protection | IP67 (excluding sealed cover and battery compartment) |
| Data Storage | 500 measurement records with timestamp, operator ID, sample ID, calibration status, and error logs |
| Power Options | 4 × AA alkaline batteries, rechargeable NiMH batteries (with USB+Power Module), or AC adapter (100–240 V, 50/60 Hz) |
| Interface | USB (supports 22 languages including English) |
| Measurement Modes | Normal, Signal Average, Rapid Settling Turbidity (RST) |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DR1300 FL |
| Price | Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Category | Imported |
| Model | C13410 |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Synchronized Scanning Streak Camera |
| Photocathode Material | S-20 / S-1 |
| Photocathode Dimensions | 7.0 mm × 17.48 mm |
| Spectral Response Range | 200–850 nm (S-20) / 300–1060 nm (S-1) |
| Spatial Resolution | ≥18 lp/mm (at photocathode center, λ = 530 nm) |
| Temporal Resolution | <5 ps (at fastest sweep range) |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Status | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | C16910 |
| Instrument Type | Repetitively Scanning Streak Camera |
| Photocathode Materials | S-20 / S-1 / S-20MgF₂ / S-25 / S-20ER |
| Photocathode Active Area | 0.15 mm × 4.5 mm ±5% (with ORCA-Flash4.0 V3) |
| Spectral Response Ranges | 200–850 nm |
| Spatial Resolution | ≥35 lp/mm (at photocathode center, λ = 530 nm) |
| Temporal Resolution | <800 fs FWHM (M16911-01) |
| Scan Repetition Rate | 74–165 MHz (M16911-01) |
| Scan Duration Range | ~60 ps to 1/6 fs (M16911-01 w/ ORCA-Flash4.0 V3) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | ~250 VA |
| Brand | OPHIR |
|---|---|
| Origin | USA |
| Model | HELIOS |
| Power Range | 200 W – 12 kW |
| Energy Range | 200 J – 5 kJ |
| Exposure Time | 0.3 s – 4 s |
| Wavelength Range | 750 nm – 1100 nm |
| Max Beam Diameter | 35 mm |
| Max Energy Density | 4 kJ/cm² |
| Accuracy | ±3% |
| Repeatability | ±1% |
| Response Time | 2.5 s |
| Measurement Interval | 12 s |
| Communication Interfaces | PROFINET, RS232 |
| Operating Temperature | 10–60 °C |
| Operating Humidity | 10–80% RH |
| Shutter Activation | Automatic upon measurement initiation |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Helios |
| Pricing | Available Upon Request |
| Key | Output Power ≥ 40 mW |
|---|---|
| Mode | Multimode |
| Operating Voltage | 3.5–4 kV |
| Operating Current | 15 mA |
| Wavelength | 632.8 nm |
| Origin | Tianjin, China |
| Manufacturer Type | Distributor |
| Domestic Product | Yes |
| Pricing | Upon Request |
| Brand | TOP (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GY-6 |
| Power Rating | 200 W |
| Spectral Output | Intense UV and Visible Continuum + Characteristic Mercury Emission Lines (e.g., 253.7 nm, 365 nm, 404.7 nm, 435.8 nm, 546.1 nm, 577–579 nm) |
| Lamp Geometry | Spherical Arc Tube |
| Operating Position | Universal (Horizontal/Vertical) |
| Rated Lifetime | ≥1,000 hours (at rated power, with proper cooling) |
| Cooling Requirement | Forced-air or water-cooled fixture recommended |
| Brand | Hinds Instruments |
|---|---|
| Origin | USA |
| Model | DV-193 |
| Wavelength Range | 180–200 nm (optimized at 193 nm) |
| Measurement Principle | Dual-PEM Modulated Photoelastic Polarimetry |
| Stokes Parameter Acquisition Rate | >100 Hz |
| Accuracy (180–200 nm) | ±1% |
| Sensitivity | <0.0005 |
| Repeatability (3σ, 180–200 nm) | ≤0.01 |
| Repeatability (3σ, 200–400 nm) | ≤0.0035 |
| PEM Resonant Frequency | 37–100 kHz |
| Compliance | ASTM E284, ISO 15382, USP <857>, GLP/GMP-ready data audit trail |
| Brand | HongKe |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HK-BOS Reflecting Objective |
| Magnification | 15× |
| Numerical Aperture | 0.28 |
| Working Distance | 190 mm |
| Clear Aperture | 120 mm |
| Optical Design | All-Reflective, Achromatic |
| Coating Options | Customizable Broadband Metallic (e.g., Al+MgF₂, Protected Au, or Enhanced Ag) |
| Brand | TP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | XGS-7A |
| Pricing | Upon Request |
| Brand | Hopocolor |
|---|---|
| Model | HPALTS-800 |
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic |
| Price | USD 27,500 (FOB) |
| Luminous Intensity Range | 0.1–100,000 cd |
| Luminous Intensity Accuracy | ≤±2% (under standard conditions) |
| Angular Resolution | 0.1° |
| Angular Repeatability | <0.1° |
| Cumulative Angular Error | <0.2° |
| Horizontal Rotation Range | −180° to +180° |
| Vertical Rotation Range | −90° to +90° |
| Horizontal Scan Speed | 0.5 / 1 / 2 °/s |
| Vertical Scan Speed | 0.5 / 1 / 2 °/s |
| Centering Alignment Accuracy | <0.1° (calibratable to <0.05°) |
| Ambient Light Rejection | Enabled |
| Test Distance | ≤10 m (1 m for edge lights) |
| Compliance | ICAO Annex 14, FAA AC 150/5340-30H, FAA Order 8260.19D |
| Power Output | 350 W |
| Current Measurement Accuracy | <±0.1 A |
| Current Stability | <3% |
| Input Voltage | 110–230 VAC |
| Max Load Capacity | 18 kg |
| Report Generation | Automated, GLP-compliant PDF/CSV export |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Smart SE |
| Spectral Range | 450–1000 nm |
| Spot Size Options | Multiple Micro-Spot Sizes with Real-Time Visual Observation |
| Incidence Angle | Variable (Motorized Multi-Angle Capability) |
| Measurement Speed | Full-Spectrum Acquisition in <1 Second |
| Single-Measurement Time | <2 s (Typical, Including Stage Positioning) |
| Sample Stage | Motorized XYZ Translation (200 mm × 200 mm Travel, Z-Travel >35 mm) |
| Detector | CCD-Based Spectral Analyzer |
| Modulation Technology | Liquid Crystal Variable Retarder (LCVR), No Moving Parts in Optical Path |
| Configuration Flexibility | Supports Both In-Line Process Integration and Stand-Alone Lab Use |
| Compliance | Designed for ISO/IEC 17025-Compatible Metrology Environments |
| Software | HORIBA DeltaPsi² Platform with Audit Trail, User Access Control, and Exportable Raw Data (CSV, XML, HDF5) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Smart SE |
| Measurement Speed | 5 s (typical), down to 1 s (max) |
| Wavelength Range | 450–1000 nm |
| Spot Sizes | 7 selectable configurations (e.g., 75 µm × 150 µm to 500 µm × 500 µm) |
| Software | DeltaPsi² v5.x (Windows-based) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | UVISEL |
| Pricing | Available Upon Request |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | ColorFlex EZ |
| Product Type | Color Difference Meter |
| Instrument Type | Benchtop (Not Online) |
| Optical Geometry | 45°/0° Integrating Sphere |
| Spectral Range | 400–700 nm (Visible Spectrum) |
| Repeatability | ΔE*ab < 0.08 for White Tile (10 measurements) |
| Sample Types | Opaque Solids, Liquids, Powders, Granules, Pastes, Translucent Materials |
| Standard Storage | 250 Standards (with Tolerance Sets) |
| Sample Memory | 2000 Measurements |
| Interface | 3× USB Ports (Keyboard, Barcode Scanner, USB Flash Drive, Printer) |
| Software Compatibility | EasyMatch QC v5.x or later |
| Compliance | Meets CIE No. 15:2018, ASTM E308, ISO 11664-4, USP <1061>, GLP/GMP-ready audit trail (via EasyMatch QC) |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | CQXE |
| Instrument Type | Benchtop |
| Optical Geometry | d/8° integrating sphere |
| Light Source | Pulsed Xenon Lamp (CIE Illuminant D65) |
| Spectral Range | 400–700 nm |
| Spectral Resolution | <3 nm, FWHM: 10 nm |
| Reflectance Range | 0–200% |
| Photometric Resolution | 0.003% |
| Repeatability | ΔE* < 0.03 in CIE L*a*b* on certified white tile |
| Aperture Sizes | 25.4 mm (standard), 9.5 mm (optional) |
| Transmission Chamber Dimensions | 35.6 × 16.5 × 10.2 cm |
| Mirror Finish Compensation | Automatic Specular Component Included/Excluded |
| Compliance | ASTM E308, ISO 7724-1, ISO 11664, CIE No. 15, DIN 5033, JIS Z 8722 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | LabScan XE |
| Instrument Type | Benchtop |
| Optical Geometry | 0°/45° Reflectance |
| Light Source | Pulsed Xenon Lamp (CIE D65) |
| Spectral Range | 400–700 nm |
| Spectral Resolution | <3 nm |
| Bandwidth | 10 nm |
| Reflectance Range | 0–150% |
| Reflectance Resolution | 0.003% |
| Repeatability | ΔE* < 0.09 on Ceramic White Tile |
| Aperture | 44 mm (measuring), 50 mm (illumination) |
| Compliance | CIE No. 15, ISO 7724-1, ASTM E308, DIN 5033, JIS Z 8722 |
| Brand | HunterLab |
|---|---|
| Origin | USA |
| Model | MSEZ 45/0 |
| Instrument Type | Portable |
| Optical Geometry | 0°/45° (45° illumination / 0° viewing) |
| Light Source | Pulsed Xenon Lamp |
| Spectral Range | 400–700 nm |
| Spectral Resolution | <3 nm, FWHM: 10 nm |
| Reflectance Range | 0–150% |
| Repeatability | ΔE* ≤ 0.05 (CIE L*a*b* on certified white tile) |
| Aperture Sizes | 6.0 mm (SAV), 31.8 mm (LAV) |
| Detector | 256-element silicon photodiode array with precision holographic grating |
| Display | Backlit monochrome LCD with rotatable orientation |
| Data Storage | 100 standards (with tolerance limits), 800 measurements |
| Connectivity | USB |
| Power | Rechargeable lithium-ion battery pack (optional AC adapter) |
