| Brand | TP |
|---|---|
| Model | WSZ-4A |
| Origin | Tianjin, China |
| Manufacturer | TP Instrument Co., Ltd. |
| Optical Rail Length | 1000 mm (aluminum alloy, V-groove 70°, width 80 mm, precision scale ±1 mm) |
| Rotation Stage Resolution | 0.2° (manual X-axis angular adjustment) |
| Laser Source | 650 nm semiconductor diode, nominal output 5 mW |
| Power Meter | Digital display, zero-adjustable, continuously variable gain, analog signal input |
| Polarizers & Waveplates | Mounted in precision metal frames (linear polarizer, λ/2 and λ/4 plates, Ø36 mm lens) |
| Sample Holders | Optical bench-mounted glass slide stage, Brewster angle observation window with ground-glass screen |
| Compliance | Designed for educational and metrological alignment per ISO 10110-7 (polarization optics), supports ASTM E2896 (optical training systems) and GLP-aligned lab documentation workflows |
| Brand | TP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | WYM-1 |
| Price | Upon Request |
| Steel Wire | ~90 cm length, Ø 0.25 mm |
| Molybdenum Wire | ~90 cm length, Ø 0.125 mm |
| Reading Microscope | 25× magnification, 0.05 mm graduation |
| CCD Camera | Monochrome, 420 TV lines/mm resolution |
| Vertical Column | Adjustable height, ~100 cm max |
| Monitor | 14-inch monochrome video display |
| Operating Temperature | −5 °C to 40 °C |
| Relative Humidity Range | 10–80 % RH |
| Relative Uncertainty in Young’s Modulus | <5 % |
| Brand | TOP / TP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TP-GOS1 |
| Pricing | Upon Request |
| Brand | TQC Sheen |
|---|---|
| Country of Origin | Netherlands |
| Model | SoloGloss® (single-angle) / PolyGloss® (triple-angle) |
| Measurement Angles | 20°, 60°, 85° |
| Gloss Range | 0–2000 GU |
| Resolution | 0.1 GU (0–100 GU), 1 GU (>100 GU) |
| Repeatability | 20°: ±0.4 GU |
| 60° | ±0.2 GU |
| 85° | ±0.2 GU |
| Reproducibility | 20°: ±1.69 GU |
| 60° | ±1.58 GU |
| 85° | ±1.88 GU |
| Accuracy Deviation | 20°: ±1.2 GU |
| 60° | ±0.6 GU |
| 85° | ±1.6 GU |
| Spot Size | 20°: 5 × 5 mm |
| 60° | 20 × 9 mm |
| 85° | 40 × 9 mm |
| Compliance | ISO 2813, ASTM D523, DIN 67530, JIS Z8741 |
| Brand | TRIOPTICS |
|---|---|
| Origin | Germany |
| Model | TriAngle® Electronic Autocollimator |
| Sensor Type | High-Resolution CMOS or PSD |
| Spectral Range Options | UV, Visible, NIR |
| Measurement Modes | Absolute and Relative |
| Max. Simultaneous Targets | ≤12 reflections |
| Multi-Instrument Support | Up to 12 units per PC |
| Trigger Interface | External TTL trigger supported |
| Data Export Format | CSV |
| Software | TriAngle® Control Suite v5.x (FDA 21 CFR Part 11 compliant audit trail optional) |
| Brand | ULVAC KIKO |
|---|---|
| Origin | Japan |
| Model | UNECS Series |
| Measurement Principle | Spectroscopic Ellipsometry (SE) |
| Wavelength Range Options | Standard: 530–750 nm |
| Visible-Extended | 380–760 nm |
| Minimum Acquisition Time | 20 ms per spectrum |
| Sensor Architecture | Fixed-optics, no rotating elements |
| Environmental Configurations | Ambient-air, vacuum-integrated, and in-situ chamber-mounted variants |
| Sample Stage Options | Manual, motorized XY, large-substrate (up to 300 mm), portable benchtop, and OEM-integrated modules |
| Compliance | Designed for ISO/IEC 17025-aligned calibration traceability |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | AS-36 |
| Cuvette Pathlength | 50 mm |
| Number of Positions | 4 |
| Dimensions (L×W×H) | 150 × 60 × 70 mm |
| Weight | 0.5 kg |
| Compatibility | Designed for UniCo UV-Vis spectrophotometers and standard 50 mm pathlength rectangular cuvettes |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | AS-37 |
| Cuvette Pathlength | 10 cm (100 mm) |
| Number of Slots | 4 |
| Dimensions (L×W×H) | 150 × 110 × 70 mm |
| Weight | 0.6 kg |
| Compatibility | Standard 10 cm rectangular quartz/glass cuvettes |
| Brand | UPRtek |
|---|---|
| Origin | Taiwan |
| Model | MD100N |
| Spectral Range | 380–780 nm |
| Spectral Resolution | 1 nm |
| FWHM | ~12 nm |
| Measurement Area | Ø10 mm |
| Field of View | ±1° |
| Luminance Range | 0.001–5000 cd/m² |
| Luminance Accuracy | ±2% (100–5000 cd/m²), ±3% (0.2–100 cd/m²), ±4% (0.05–0.2 cd/m²) |
| Chromaticity Accuracy | ±0.002 CIE1931 x,y (100–5000 cd/m²), ±0.003 (0.2–100 cd/m²), ±0.005 (0.05–0.2 cd/m²) |
| Stray Light | ≤−25 dB |
| Polarization Error | <2% |
| Integration Time | 100 µs–5000 ms |
| Digital Resolution | 16-bit |
| Flicker Sampling Rate | up to 100 kS/s |
| Dimensions | 204 × 90 × 45 mm |
| Weight | 630 g ±10 g |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | WD-A |
| Pricing | Upon Request |
| Temperature Range | 6–70 °C (±2 °C accuracy) |
| Humidity Range | 10–95 %RH (±4 %RH accuracy) |
| Illuminance Range | 0–7000 lx (adjustable, natural light reference included) |
| Chamber Dimensions | 510 × 400 × 380 mm (dual-tier stainless steel interior with removable partitions) |
| Construction | AISI 304 stainless steel chamber and shelves |
| Brand | WeSpectra |
|---|---|
| Origin | Shanghai, China |
| Model | SpectraLED Pro |
| LED Channels | 21 |
| Spectral Range | 360–780 nm |
| CCT Tuning Range | 2000–20000 K (±1% accuracy) |
| CIE Ra | ≥99 |
| Flicker Frequency | 1–1000 Hz (1 Hz step) |
| Dimming Resolution | 12-bit per channel (4000 levels) |
| Uniformity | ≥80% |
| Max Illuminance | ≥2000 lx (D-series), Low-Light Mode: 0.1–50 lx |
| Preheat Time | 0 s |
| LED Lifetime | ≥10,000 h |
| Storage | 80 user-editable presets (hardware), unlimited via software |
| Dimensions (L×H×W) | 990×930×685 mm |
| Viewing Chamber (L×H×W) | 890×585×620 mm |
| Cabinet Color | Munsell N7 |
| Weight | ~40 kg |
| Power Input | 110–240 V AC, max 500 W |
| Operating Temperature | 0–40 °C |
| Compliance | ISO 23603, ISO 3664, ASTM D1729 |
| Software Integration | SDK with API support for automated calibration and third-party instrument synchronization (e.g., Konica Minolta CL-500A, JETI Specbos 2501/2501uv) |
| Brand | TOP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | GY-14 |
| Pricing | Upon Request |
| Brand | TOP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WHS-1 |
| Price | Upon Request |
| Wavelength Range | 800–2500 nm |
| Relative Aperture | D/F = 1/7 |
| Grating Density | 300 lines/mm |
| Focal Length | 300 mm |
| System Composition | f = 300 mm Czerny–Turner monochromator, photodetector unit (InGaAs-based), variable-color-temperature tungsten-halogen lamp source, Windows-based control software on USB-delivered installation media, integrated electronic control module |
| Interface | USB 2.0 |
| Brand | Wintree |
|---|---|
| Origin | Japan |
| Model | Photochron TR-200P |
| Product Type | Spectrophotometric Densitometer |
| Instrument Form Factor | Benchtop |
| Optical Geometry | 45°/0 (Annular Illumination, Normal Viewing) |
| Light Source | White LED |
| Spectral Range | 400–700 nm |
| Reflectance Measurement Range | 0.00–120.00% |
| Repeatability | ±1% |
| Compliance | ISO 5435:2017, JIS K6217-5:2010 |
| Interface | RS-232C |
| Display | LED Numeric Display |
| Printer | Thermal Printer |
| Calibration | Auto-standard CAL function |
| Dimensions (Main Unit) | 240 × 125 × 290 mm (W×H×D) |
| Detector Head Dimensions | 110 × 120 × 50 mm (W×H×D) |
| Brand | WK-OPTICS |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WKGX-B |
| Aperture | 150 mm |
| Resolution | 2048 × 2048 |
| Primary Mirror Material | K9 Optical Glass |
| Surface Figure Accuracy | < λ/10 @ 632.8 nm |
| Reflectivity | ≥90% |
| Coating | Vacuum-deposited Aluminum + SiO₂ Protective Layer |
| Light Source | Adjustable-intensity, Air-cooled LED or Halogen |
| Slit Assembly | Rotatable Aperture with Precision Adjustment |
| Mounting | Standard ISO 1222 Threaded Base Holes (M6) |
| System Architecture | Two-Platform Configuration (Collimation Platform + Schlieren Imaging Platform) |
| Brand | WK-OPTICS |
|---|---|
| Origin | Sichuan, China |
| Model | WKWY-300 |
| Clear Aperture | 300 mm |
| Resolution | ≥20 lp/mm |
| Field of View | Φ1000 mm (at working distance) |
| Relative Aperture | f/10 to f/20 |
| Primary Mirror Material | K9 optical glass |
| Surface Accuracy | < λ/10 RMS |
| Reflectivity | ≥90% (Al + SiO₂ coating) |
| Slit Options | Single slit, multi-slit, pinhole, dispersion prism/grating, colored circular/square aperture |
| Knife-edge Configurations | Single, dual, quad, grid, or circular edge |
| Structural Design | Modular, tubular, or planar optical bench architecture |
| Light Sources | Laser, LED, or tungsten-halogen |
| Imaging Sensors | DSLR, high-speed camera, or photographic plate |
| Compliance | ISO 10110-5 (optical surface quality), GB/T 28296-2012 (Chinese national standard for schlieren systems) |
| Brand | Top Optics (TP) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WSY-2 |
| Pricing | Available Upon Request |
| Core Components | Optical Rail, 2D Adjustable Mounts, Photographic Plate Holder, White Screen, Single-Sided Adjustable Slit, Low-Pressure Sodium Lamp, Fresnel Biprism, Newton’s Rings Set, Convex Lenses, Measuring Microscope, Double-Slit Assembly |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | pHotoFlex pH |
| Wavelength Accuracy | < 2 nm |
| Wavelengths | 436, 517, 557, 594, 610, 690 nm |
| Photometric Range | Absorbance –2.00 to +2.00 A |
| pH Measurement Range | 0.00–16.00 |
| Accuracy | ±0.01 pH |
| Data Storage | 1000 measurement records + 100 user-defined methods |
| Auto-zero | Yes (on power-up) |
| Calibration | 3-point pH calibration |
| Interface | RS232 (USB optional) |
| Protection Rating | IP67 |
| Power Supply | 4 × AA alkaline batteries (≥3000 measurements) or optional rechargeable pack |
| Dimensions | 236 × 86 × 117 mm |
| Weight | 0.6 kg (without batteries) |
| Compliance | cETLus certified |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | 750 |
| Instrument Type | Benchtop Laboratory Turbidimeter |
| Measurement Range | 0–1100 FNU/NTU |
| Resolution | 0.01 FNU/NTU (0.00–9.99), 0.1 FNU/NTU (10–99.99), 1 FNU/NTU (100–1100) |
| Operating Temperature | +5 to +55 °C (41–131 °F) |
| Accuracy | ±0.01 FNU/NTU or ±2% of reading (±3% at 500–1100 NTU for Turb 750T) |
| Compliance Standards | DIN EN ISO 7027-1 (Turb 750IR), US EPA Method 180.1 (Turb 750T) |
| Data Storage | 2500 datasets with calibration protocols and AQA flags |
| Interface | USB, RS-232, printer port |
| GLP-Compliant Software | Turb Data PC software (CSV export, LIMS import, user authentication, audit trail) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | 600120 |
| Instrument Type | Benchtop Laboratory Turbidimeter |
| Measurement Range | 0–1100 FNU/NTU |
| Resolution | 0.01 FNU/NTU (0.00–9.99), 0.1 FNU/NTU (10–99.99), 1 FNU/NTU (100–1100) |
| Operating Temperature | +5 to +55 °C (41–131 °F) |
| Accuracy | ±0.01 FNU/NTU or ±2% of reading (±3% at 500–1100 FNU/NTU) |
| Compliance Standard | DIN EN ISO 7027-1 |
| Light Source | Infrared LED |
| Detection Angle | 90° Nephelometric Scattering |
| Display | Backlit Graphic LCD (160 × 104 pixels) |
| Data Storage | 2500 datasets with calibration protocols and AQA flags |
| Interface | USB, RS-232, optional printer |
| GLP Support | Full audit trail, user ID, sample ID, calibration interval tracking, electronic signatures via Turb Data software |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | 962 |
| Spectral Range | 400–700 nm |
| Reflectance Range | 0–200% |
| Repeatability (ΔE*ab) | ≤0.10 |
| Inter-instrument Agreement (ΔE*ab) | ≤0.20 |
| Measurement Time | ~2 s |
| Aperture Options | 15 mm, 7 mm, 4 mm |
| Dimensions | 109 × 84 × 196 mm |
| Weight | 1100 g |
| Illuminant | Pulsed Tungsten Halogen Lamp |
| Power Supply | 90–130 VAC / 100–240 VAC, 50–60 Hz |
| Storage Capacity | Up to 1,024 Pass/Fail Tolerance Sets |
| Display | Large Graphical LCD |
| Battery | Rechargeable for Field Operation |
| Geometry | 0°/45° (Fixed Illumination/Viewing Angle) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Capsure |
| Weight | 170 g (including battery) |
| Display | 1.75-inch full-color LCD |
| Memory Capacity | Up to 100 color measurements |
| Connectivity | Sync with PANTONE libraries and design software (Adobe Photoshop, Adobe Illustrator, QuarkXPress) |
| Power | Rechargeable lithium-ion battery |
| Timestamping | Date and time stamp for each measurement |
| Compliance | Designed for PANTONE®-aligned color workflows |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci4100 |
| Geometry | d/8° integrating sphere |
| Repeatability (white tile) | ≤ 0.10 ΔE*ab |
| Inter-instrument agreement (avg.) | ≤ 0.30 ΔE*ab |
| Spot size | 14 mm |
| Measurement aperture | 8 mm |
| Spectral range | 400–700 nm |
| Spectral interval | 10 nm |
| Detector | blue-enhanced silicon photodiode |
| Illuminant | tungsten-halogen lamp (≈500,000 measurements lifespan) |
| Measurement time | ≈2 s |
| Reflectance range | 0–200% |
| Reflectance resolution | 0.01% |
| Gloss measurement | 60° geometry (ASTM D523 compliant) |
| Operating temperature | 10–40 °C |
| Relative humidity | 5–85% RH (non-condensing) |
| Dimensions (W×D×H) | 19.0 × 26.4 × 22.0 cm |
| Weight | 5.2 kg |
| Power | 100–240 VAC, 50/60 Hz or 12 VDC @ 2.5 A |
| Interface | USB 2.0 |
| Included accessories | White calibration tile, black trap, AC adapter, USB cable, operation manual (CD), sample holder |
| Warranty | 12 months |
| Software compatibility | XDS4 SDK, ColorDesigner PLUS |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ci60 |
| Pricing | Available Upon Request |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ci62 |
| Pricing | Upon Request |
| Aperture | 4 mm measurement / 6.5 mm target window or 8 mm measurement / 14 mm target window |
| Light Source | Tungsten-halogen lamp |
| Inter-instrument Agreement | Avg. ΔE*ab ≤ 0.20 (CIE L*a*b*, 12 BCRA Series II tiles, SCI mode), Max. ΔE*ab ≤ 0.40 (any flat tile, SCI mode) |
| Short-term Repeatability | ΔE*ab ≤ 0.05 (white tile) |
| Data Interface | USB 2.0, Bluetooth v4.0 |
| Standard Accessories | Black trap, white & green calibration tiles, user manual, AC adapter, NetProfiler software, sample holder, bench stand, spare battery, dual-bay charger |
| Measurement Modes | QA, Comparison, Opacity, Strength, Job-based workflow |
| Cross-platform Compatibility | Seamless data exchange with X-Rite SP62 spectrophotometers |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ci64 |
| Pricing | Upon Request |
| Aperture Options | 4 mm measurement / 6.5 mm target window |
| Light Source | Tungsten-halogen lamp |
| Inter-instrument Agreement (8 mm/14 mm or 14 mm/20 mm) | Avg. ΔE*ab = 0.13 (CIE L*a*b*, including SCI, based on 12 BCRA Series II tiles) |
| Inter-instrument Agreement (4 mm/6.5 mm) | Avg. ΔE*ab = 0.20 |
| Short-term Repeatability | 0.04 ΔE*ab (on white tile) |
| Data Interfaces | USB 2.0, Bluetooth v4.0 |
| Standard Accessories | Black trap, white & green calibration tiles, user manual, AC adapter, NetProfiler software, sample holder, bench stand, spare battery, dual-bay charger |
| Operating Modes | QA, Comparison, Opacity, Strength, Job & Project |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ci64UV |
| Pricing | Upon Request |
| Aperture Options | 4 mm measurement / 6.5 mm target window OR 8 mm measurement / 14 mm target window |
| Light Source | Tungsten Halogen Lamp + Adjustable UV LED |
| Inter-instrument Agreement (8 mm/14 mm, SCI) | Avg. 0.13 ΔE*ab (BCRA Series II, 12 tiles), Max 0.25 ΔE*ab (any planar surface) |
| Inter-instrument Agreement (4 mm/6.5 mm, SCI) | Avg. 0.20 ΔE*ab (BCRA Series II, 12 tiles), Max 0.40 ΔE*ab (any planar surface) |
| Short-term Repeatability | 0.04 ΔE*ab (on white tile) |
| Data Interfaces | USB 2.0, Bluetooth v4.2 |
| Standard Accessories | Black trap, white & green calibration tiles, UV calibration standard, user manual, AC adapter, NetProfiler software, sample holder, bench stand, spare battery, dual-bay charger |
| Operating Modes | QA, Comparison, Opacity, Strength, Project & Job |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7600 |
| Geometry | d/8° (SPIN & SPEX) |
| Short-Term Repeatability | ≤ 0.03 ΔE*ab RMS on white tile |
| Inter-instrument Agreement | ≤ 0.15 ΔE*ab avg. |
| Aperture Sizes (Reflectance) | 25 mm, 17 mm*, 10 mm, 6 mm, 3.5 mm* |
| Aperture Sizes (Transmittance) | 3 standard + 2 optional |
| Measurement Spot Sizes | 20 mm, 12 mm, 5 mm, 2.7 mm |
| Measurement Time | ≈ 2.5 s |
| Spectral Range | 360–750 nm |
| Spectral Interval | 10 nm (default), 20 nm selectable |
| Optical System | 2D CCD array with holographic grating |
| Illuminant | Pulsed xenon lamp, D65 calibrated |
| UV Control | Integrated UV filters (up to 3) |
| Photometric Resolution | 0.01% |
| Lamp Lifetime | ≥ 1,000,000 measurements |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −20–50 °C |
| Relative Humidity | 5–85%, non-condensing |
| Dimensions (L×W×H) | 56 × 22 × 31 cm |
| Weight | 20.5 kg |
| Shipping Dimensions | 71 × 38 × 53 cm |
| Shipping Weight | 25 kg |
| Interface | USB 2.0 |
| Software Development Kit | XDS4 |
| Embedded NetProfiler | Yes |
| Internal Temp/Humidity Sensor | Yes |
| Laser Targeting | Yes |
| Sample Preview Camera | Yes |
| Status Panel | LED-based |
| Power | 100–240 VAC, 50–60 Hz |
| Warm-up Time | None required |
| Calibration Standards | Included white tile, black trap, UV calibration kit |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7800 |
| Geometry | d/8° (diffuse illumination, 8° viewing) |
| Short-term Repeatability (White Tile) | ≤ 0.01 ΔE*ab RMS |
| Inter-instrument Agreement | ≤ 0.08 ΔE*ab avg. |
| Spot Sizes | 25 mm, 17 mm, 10 mm, 6 mm, 3.5 mm |
| Aperture Sizes | 20 mm, 12 mm, 5 mm, 2.7 mm |
| Measurement Time | ≈ 2.5 s |
| Spectral Range | 360–780 nm |
| Spectral Interval | 10 nm (default), 5 nm, 20 nm |
| Spectral Reporting | 10 nm, 5 nm, 20 nm |
| Illuminant | Pulsed Xenon (D65 calibrated) |
| Photometric Range | 0–200% |
| Photometric Resolution | 0.00% |
| Detector | 2D CCD Array with Holographic Grating |
| Reflectance Apertures | 4 standard + 1 optional |
| Transmittance Apertures | 4 |
| UV Control | Up to 3 UV filters |
| Operating Humidity | 5–85% RH (non-condensing) |
| Operating Temperature | 5–40 °C |
| Storage Temperature | −20–50 °C |
| Dimensions (L×W×H) | 56 × 22 × 31 cm |
| Weight | 20.5 kg |
| Shipping Dimensions | 71 × 38 × 53 cm |
| Shipping Weight | 25 kg |
| Interface | USB 2.0 |
| Software Development Kit | XDS4 |
| Built-in Camera | Yes (preview + active laser target positioning) |
| Embedded NetProfiler Support | Yes |
| Internal Temp/Humidity Sensors | Yes |
| Lamp Timer | Yes |
| UV Calibration Tools | White tile, black trap, UV reference standards |
| Compliance | ASTM E308, ISO/CIE 11664, ISO 7724, ISO 13655, USP <1061>, FDA 21 CFR Part 11 (via compatible software) |
| Brand | X-Rite |
|---|---|
| Origin | USA |
| Model | Ci7860 |
| Product Type | Benchtop Spectrophotometer |
| Instrument Type | Benchtop |
| Optical Geometry | 0/45° Integrating Sphere |
| Illuminant | UV-Enabled |
| Spectral Range | 360–780 nm |
| Repeatability (RMS ΔE*) | 0.01 |
| Inter-instrument Agreement (Avg. ΔE* SCI) | 0.06 |
| Spectral Resolution | 10 nm |
| Photometric Resolution | 0.001% |
| UV Filter Options | Standard 400 nm, Optional 420 nm & 460 nm |
| Reflectance Apertures | 25 mm, 17 mm, 10 mm, 6 mm, 3.5 mm (optional) |
| Transmittance Apertures | 27 mm, 17 mm, 10 mm, 6 mm |
| Dual-Mode Measurement | SPIN & SPEX Simultaneous |
| Compliance | CIE 15:2018, ASTM D2244, ASTM E308, ISO 7724-1, ISO 13655, ISO 17972-1 (PantoneLIVE), FDA 21 CFR Part 11 (with Color iQC v6.0+) |