| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP160 |
| Instrument Type | Industrial Online ORP Meter |
| Display | 128×64 Dot-Matrix LCD (Chinese Interface) |
| Measurement Range | ±2000 mV |
| Electrical Accuracy | ±1 mV |
| Resolution | 0.1 mV |
| Temperature Compensation Range | 0–60 °C |
| Sample Temperature Range | 5–60 °C |
| Sample Pressure Limit | < 0.6 MPa |
| Environmental Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Storage/Transport Temperature | −25–55 °C |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤15 W |
| Output Signals | Isolated Current Output (0–10 mA / 0–20 mA / 4–20 mA), Load < 300 Ω |
| Relay Outputs | 2 SPST (AC 220 V / 3 A or DC 30 V / 3 A), Configurable Alarm Thresholds |
| Enclosure Rating | IP65 |
| Data Logging | Cyclic Storage with Auto-Overflow Management |
| Memory Retention After Power Loss | >10 Years |
| Dimensions (H×W×D) | 145 mm × 120 mm × 150 mm |
| Panel Cutout | 138 mm × 138 mm |
| Weight | 0.64 kg |
| Electrode Type | Pt-based Redox Electrode (Direct Potentiometric Measurement) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | SenTix ORP |
| Type | Laboratory ORP Electrode |
| Reference Electrolyte | 3 M KCl |
| Operating Temperature Range | 0–100 °C |
| Sensor Material | Platinum |
| Junction Type | Ceramic (S7 thread) |
| Connector | S7 (cable required separately: AS DIN, AS DIN-3, or AS BNC) |
| Compliance | Designed for ISO/IEC 17025-compliant labs, compatible with GLP/GMP data integrity workflows |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | SenTix ORP-T 900 |
| Catalog No. | 103791 |
| Measurement Range | –1250.0 to +1250.0 mV |
| Sample Temperature Range | 0 °C to 100 °C |
| mV Accuracy | ±0.2 mV |
| Temperature Accuracy | ±0.1 °C |
| Temperature Sensor | Integrated NTC30 |
| Electrolyte | 3 mol/L KCl |
| Junction | Ceramic |
| Cable Length | 1.5 m (integrated, IP67 waterproof digital connector) |
| Electrode Material | Platinum |
| Shaft Material | Glass |
| Shaft Diameter | 12 mm |
| Shaft Length | 120 mm |
| Compliance | Compatible with MultiLine, MonoLine, and inoLab IDS meters |
| Brand | YST (Dalian Yist Instruments) |
|---|---|
| Origin | Liaoning, China |
| Model | YST209B-RP880 |
| Measurement Range | -1999 to +1999 mV |
| Accuracy | ±2 mV @ 25 °C |
| Response Time | ≤10 s (to 90% of final value) |
| Temperature Compensation | Automatic, 0–100 °C |
| Output Signals | Isolated 4–20 mA + RS485 digital interface |
| Sensor IP Rating | IP68 |
| Transmitter IP Rating | IP65 |
| Operating Ambient | 0–60 °C, ≤90% RH (non-condensing, away from strong magnetic fields) |
| Power Supply | 220 V ±10%, 50 Hz |
| Installation Type | Submersible (tank/pipeline) |
| Brand | YSTorp (Dalian Yistorp) |
|---|---|
| Origin | Liaoning, China |
| Model | YST209B-RP880 |
| Measuring Range | ORP –1999 to +1999 mV (0.1 mV resolution) |
| Accuracy | ±1 mV (ORP), ±0.5 °C (Temperature, 0–60.0 °C) |
| Automatic Temperature Compensation (ATC) | 0.0–120.0 °C (reference 25 °C) |
| Output | 4–20 mA isolated analog output |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Enclosure Rating | IP65 |
| Dimensions | 96 × 96 × 110 mm (panel cutout: 92 × 92 mm) |
| Installation Options | Flow-through, submersible, flanged, pipe-mounted, sidewall-mounted |