Other Industry Specialized Instruments
Filter
Showing 61–90 of 267 results
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | F1-24 |
| Construction | Transparent acrylic base with stainless steel impulse and check valves |
| Air chamber | Mounted above valve chamber to dampen pressure pulsations |
| Adjustable mass loading | Provided calibrated weights for impulse valve closure pressure tuning |
| Hydraulic supply interface | Quick-release coupling compatible with standard hydraulics workbenches |
| Accessories | Inlet/outlet flexible hoses, adjustable acrylic collection tank, optional educational software package |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | F1-26 |
| Configuration | Modular Series or Parallel Pumping System |
| Mounting | Floor-standing Base with Integrated ON/OFF Switch |
| Flow Control | Adjustable Flow Control Valve |
| Pressure Monitoring | Built-in Pressure Gauge on Discharge Manifold |
| Connectivity | Quick-connect Fittings for Flexible Hydraulic Bench Integration |
| Optional | Educational Software Package for Data Acquisition and Experiment Simulation |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | F1-27 |
| Drive | Inverter-controlled AC motor |
| Pump Speed Range | 0–3000 rpm (adjustable) |
| Pressure Measurement | Inlet compound gauge, outlet pressure gauge, discharge manifold pressure gauge |
| Flow Control | Adjustable valve integrated into discharge manifold |
| Mounting | Floor-standing base with leveling feet |
| Compatibility | Designed exclusively for integration with Armfield F1-10 / F1-10-2 Hydraulic Bench |
| Interconnection | Quick-release flexible hoses for series or parallel configuration |
| Optional | Educational software package for data acquisition and pump performance curve generation |
| Compliance | CE-marked |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | RE10 |
| Dimensions (L×W×H) | 0.640 m × 0.165 m × 0.370 m |
| Operating Temperature | +10°C to +50°C |
| Storage Temperature | −10°C to +70°C |
| Relative Humidity (non-condensing) | 0–95% RH |
| Net Weight | 7.5 kg |
| Enclosure | Anodized aluminum portable case |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | RE16 |
| Storage Temperature | −10 °C to +70 °C |
| Operating Temperature | +10 °C to +50 °C |
| Operating Relative Humidity | 0–95% non-condensing |
| Dimensions (L×W×H) | 0.640 m × 0.165 m × 0.370 m |
| Shipping Volume | 0.038 m³ |
| Gross Weight | 8.5 kg |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | RE18 |
| Dimensions (L×W×H) | 0.640 m × 0.165 m × 0.370 m |
| Operating Temperature | +10 °C to +50 °C |
| Storage Temperature | −10 °C to +70 °C |
| Relative Humidity (non-condensing) | 0–95 % RH |
| Net Weight | 10 kg |
| Enclosure | Modular aluminum portable case with integrated storage |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | RE24 |
| Dimensions (L×W×H) | 0.640 m × 0.165 m × 0.370 m |
| Storage Temperature | −10 °C to +70 °C |
| Operating Temperature | +10 °C to +50 °C |
| Operating Relative Humidity | 0–95% RH (non-condensing) |
| Shipping Volume | 0.038 m³ |
| Gross Weight | 7 kg |
| Compliance | CE-marked, RoHS-compliant, designed for educational laboratory use under ISO/IEC 17025-aligned pedagogical frameworks |
| Brand | Artinis |
|---|---|
| Country of Origin | Netherlands |
| Model | CD DISC 2.0 |
| Material | Acrylic (PMMA) |
| Tolerance | ±0.03 mm |
| Hole Depth Range | 0.3–8.0 mm (exponential increment) |
| Hole Diameter Range | 0.3–8.0 mm (exponential increment) |
| Total Segments | 240 |
| Concentric Rings | 16 |
| Radial Spokes | 15 |
| Phantom Thickness | Adjustable via stacked acrylic plates |
| Brand | Artinis |
|---|---|
| Origin | Netherlands |
| Model | CDMAM 3.4 |
| Gold Foil Thickness Range | 0.03–2.00 µm (16 logarithmic steps) |
| Gold Disc Diameter Range | 0.06–2.0 mm (16 logarithmic steps) |
| PMMA Cover Dimensions | 240 × 162 × 3 mm |
| Base Material | 0.5 mm Al (99.5%) |
| PMMA Support Plates | 4 × 10 mm (polished, thickness tolerance ±0.1 mm) |
| Brand | Artinis |
|---|---|
| Origin | Netherlands |
| Model | DBT TOMO |
| Dimensions (Z-resolution plate) | 320 × 260 × 5 mm PMMA with 25 embedded 1 mm Al spheres |
| Homogeneous phantom | 320 × 260 × 45 mm PMMA block, ±0.1 mm thickness tolerance, optically polished |
| Spacer plates | 7 × (320 × 260 × 10 mm PMMA), ±0.1 mm tolerance |
| Z-resolution base plate | 320 × 260 × 5 mm PMMA, ±0.1 mm tolerance |
| Stainless steel support plate | 320 × 260 × 3 mm |
| NPS attenuator | 200 × 200 × 2 mm Al, ±0.05 µm thickness tolerance |
| Stainless steel MTF edge tool | 120 × 60 × 0.8 mm, 50 µm rectangular edge |
| Aluminum foils | 8 × (100 × 100 × 0.1 mm) |
| SDNR foil | 10 × 10 × 0.2 mm Al, ±2 µm tolerance |
| X-ray rulers | 4 pieces, ±5 cm range, 1 mm graduation |
| PMMA test blocks | 2 × (180 × 15 × 10 mm), 2 × (180 × 30 × 30 mm), 7 × (40 × 20 × 2 mm) |
| EU-standard foam inserts | 5 × (240 × 180 × 20 mm) |
| Tungsten wire | 25 µm diameter, 1 m length |
| Transport case | IP67-rated Peli™ Case |
| Brand | Artinis |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Intra Oral QC |
| Price | USD 3,950 (excl. VAT & shipping) |
| Brand | Artinis |
|---|---|
| Origin | Netherlands |
| Model | MTF Test Tool |
| Compliance | EPQC 4th Ed., EUREF Type Test Protocol v1.3, IEC 61223-3-2:2007, IEC 61223-2-6:2019, NHSBSP Equipment Report 0604 (3rd Ed., Apr 2009) |
| Dimensions (Stainless Steel Tool) | 120 × 60 × 0.8 mm |
| Edge Ripple Tolerance | ±50 µm on both 120 mm edges |
| Aluminum Reference Plate | 200 × 200 × 2 mm |
| Thickness Tolerance (Al Plate) | ±50 µm |
| Brand | Asahi Spectra |
|---|---|
| Origin | Japan |
| Model | HAL-320 |
| Light Source | 300 W Xenon Arc Lamp |
| Spectral Range | 350–1100 nm |
| Spectral Match Class | JIS/IEC Class A (AM1.5G) |
| Spatial Uniformity | ≤±2% (over 30×30 mm, ND-filtered) |
| Temporal Stability | ≤±1% (over 1 h, RMS) |
| Illumination Mode | Steady-State |
| Control Interface | RS232C |
| Power Input | AC 90–264 V, 50/60 Hz |
| Max Power Consumption | <510 VA |
| Cooling | Forced Air |
| Lamp Lifetime | 500 h (avg.) |
| Dimensions (Host) | 200 × 300 × 292 mm |
| Weight (Host) | 11.3 kg |
| Brand | Asahi Spectra |
|---|---|
| Origin | Japan |
| Model | MAX-350 |
| Output Wavelength Range | 250–1050 nm (dependent on mirror module) |
| Light Output Intensity | 0–900 mW/cm² (spectrally dependent, continuously adjustable) |
| Light Source | Cermax® 300W xenon arc lamp |
| Lamp Lifetime | ≥500 h |
| Cooling Method | Forced-air cooling |
| Shutter Type | Pulsed motor-driven, exposure time 0.5 s – 24 h |
| ND Attenuation | 1000–50 steps (continuous) |
| Filter Wheel | 8-position, accepts 25 mm diameter × <6 mm thick filters |
| Mirror Modules | UV (250–385 nm), UV-VIS (300–600 nm), VIS (385–740 nm), IR (750–1050 nm) |
| Control Interface | Built-in touchscreen + RS-485 remote control |
| Safety Features | Lamp fault detection, fan failure monitoring, thermal overheat protection |
| Operating Environment | 10–35 °C, 20–80% RH (non-condensing) |
| Dimensions | 196 × 330 × 302 mm (W×D×H) |
| Weight | 12.2 kg |
| Power Input | AC 100–240 V, 50/60 Hz |
| Max Power Consumption | <540 VA (100 V/50 Hz), <520 VA (240 V/50 Hz) |
| Beam Alignment | Alignment-free (integrated optical housing) |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | AS-GP1 |
| Measurement Principle | Dual-finger-type quasi-static compression with real-time viscoelastic force feedback |
| Sensor Type | Lightweight, bidirectional tactile probes with adjustable clamping displacement and dwell time |
| Output Parameters | Maximum Stress (kPa), Skin Hardness Index, Elastic Recoil Ratio (%), Viscoelastic Relaxation Time Constant (s), Collagen Aging Index (unitless derived metric), Initial Rebound Velocity (mm/s), Sagging Index (normalized strain recovery deficit) |
| Compliance | Designed for GLP-aligned dermatological research workflows |
| Software Interface | PC-based acquisition with waveform visualization, timestamped data export (CSV, PNG), and multi-point protocol storage |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | AS-TZ1 |
| Measurement Principle | Low-frequency AC impedance |
| Impedance Range | 0.5–99 kΩ |
| Phase Angle Range | 0–90° |
| Repeatability | ±2% (0.1–10 kΩ), ±1% (10–99 kΩ) |
| Excitation Voltage | 5 V DC |
| Test Frequency | 12 Hz |
| Electrodes | Ag/AgCl (donor side), Ag (receiver side) |
| Display | 65 × 15 mm LCD |
| Dimensions | 190 × 60 × 200 mm |
| Power Supply | 6 V DC (battery-operated) |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | ASA-03RXD |
| Imaging Principle | CCD-based 30° parallel-light profilometry |
| Sample Type | Silicone replica |
| Quantitative Output | Wrinkle count, volume (triangular cross-section model), depth, width, area ratio, texture parameters (Rz, Rt), 3D surface visualization |
| Compliance | JSCA Guideline for Evaluation of Anti-Wrinkle Products |
| Software Platform | Windows 10 native application with calibration, edge enhancement, and XY/depth conversion modules |
| Optional Modules | Sebum measurement kit (ASS-001 SEBU patch + absorbance analysis software) |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | ASA-MX100 |
| Measurement Principle | Conductivity-based Corneal Hydration & Transepidermal Electrical Resistance (TEER) |
| Probe Types | C3D-MX (3D skin models), R2-MX (scalp), T4-MX (nail) |
| Measurement Time | 5 s per reading |
| Electrode Configuration | Separated excitation/detection electrodes |
| Output Interface | RS-232 digital port |
| Calibration | Fully digital one-button calibration |
| Compliance | Designed for GLP-compliant dermatological research and cosmetic efficacy testing |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | ASP-02 |
| Measurement Range | 0–9 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.2 pH |
| Response Time | ≤10 s |
| Calibration | Two-point with pH 4.0 and pH 7.0 standard buffers |
| Operating Temperature | 0–50 °C |
| Storage Environment | 5–50 °C, 5–85% RH (non-condensing) |
| Power Supply | 2 × AA alkaline batteries |
| Main Unit Dimensions | 122 × 80 × 33.5 mm (H×W×D) |
| Main Unit Weight | ~200 g |
| Electrode Dimensions | 135 mm length × φ12 mm diameter |
| Cable Length | 1 m |
| Electrode Weight | ~60 g |
| Sample Interface | Flat-surface combination pH electrode for direct skin contact |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | AS-VT100RS |
| Measurement Principle | Closed-chamber dynamic humidity gradient analysis |
| TEWL Range | 0–300 g/m²/h |
| Resolution | 0.1 g/m²/h |
| Measurement Time | 5–14 s |
| Probe Aperture Options | 6, 8, 10, or 12 mm (DIP-switch configurable) |
| Dimensions | 165 × 70 × 28 mm |
| Weight | 200 g |
| Power Supply | AC adapter or AA batteries |
| Environmental Monitoring | Integrated temperature & relative humidity sensors |
| Data Output | RS-232 serial interface |
| Sample Types | Human skin (in vivo), excised animal skin (rat, pig, rabbit), 3D reconstructed human epidermis (RHE), and cultured skin models |
| Brand | ASE |
|---|---|
| Origin | Japan |
| Model | LHT-04 |
| Measurement Principle | Ventilated Capsule Method |
| Measurement Range | 0.00–3.00 mg/cm²/min (at 30 °C, 40 % RH) |
| Accuracy | ±10 % |
| Response Time | 1 s |
| Measurement Area | 1 cm² |
| Channel Count | 1 |
| Probe Length | 0.9 m (standard), up to 1.2 m (optional) |
| Data Logging Duration | 4 h |
| Power Supply | 2 × AA batteries |
| Operating Temperature | 15–35 °C |
| Operating Humidity | 40–60 % RH |
| Dimensions (W×H×D) | 76 × 35 × 135 mm |
| Weight | 350 g |
| Compliance | Designed for ISO 9241-305 (human thermal comfort), ASTM E1980 (sweat rate in physiological testing), and GLP-aligned data integrity workflows |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | RESOChron |
| Pricing | Available Upon Request |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RESOChron U-Th/He |
| Pricing | Available Upon Request |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RESOlution-3 |
| Pricing | Available Upon Request |
| Brand | ASI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RESOlution-5 |
| Quotation | Upon Request |
| Laser Pulse Width | 5–7 ns |
| Pulse Energy | 12 mJ |
| Pulse Energy Stability | <2% RSD |
| Repetition Rate | 300 Hz |
| Fluence | >20 J/cm² |
| Sample Stage Travel Range | 155 × 105 mm |
| System Weight | 750 kg (1600 lbs.) |
| Brand | Asida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QQ1000 |
| Pricing | Available Upon Request |
| Brand | ASIDA |
|---|---|
| Model | QQ1000 |
| Origin | Guangdong, China |
| Detection Principle | Non-contact CCD-based laser triangulation |
| Max. PCB Size | 630 × 550 mm |
| Min. PCB Size | 40 × 80 mm |
| Thickness Range | 0.3–5.0 mm |
| Warpage Measurement Range | 0.3–3.0 mm |
| Accuracy | ±0.1 mm |
| Conveyor Speed Options | 6.5 m/min or 12.5 m/min |
| Minimum Board Spacing | ≥40 mm |
| Operating Temperature | 22 °C ± 5 °C |
| Power Supply | AC 220 V, 50 Hz |
| Air Pressure Requirement | 0.5–0.7 MPa |
| Dimensions (L×W×H) | 3510 × 1160 × 1050 mm |
| Weight | 450 kg |
| Brand | Asida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | XK Series |
| Pricing | Available Upon Request |
| Measurement Accuracy | ±1 µm |
| Pixel Resolution | XK16/XK22: 0.70–5.20 µm/pixel |
| XK23 | 0.4–2.6 µm/pixel |
| Total Optical Magnification | 70×–450× |
| Objective Magnification | 1.4×–9× (continuous) |
| Maximum Board Width | ≤760 mm |
| Field of View | 0.53×0.4 mm to 3.4×2.5 mm |
| Minimum Measurable Line Width | ≥20 µm |
| Instrument Dimensions (w/o PC) | XK16: 135×135×310 mm |
| XK22 | 960×700×1280 mm |
| XK23 | 960×780×1280 mm |
| Weight | XK16: 1.52 kg |
| XK22 | 145 kg |
| XK23 | 190 kg |
| Brand | ASIDA |
|---|---|
| Model | XK22 |
| Origin | Guangdong, China |
| Type | Optical Metrology System for Printed Circuit Board Inspection |
| Measurement Principle | High-Resolution Digital Microscopy with Sub-Pixel Edge Detection |
| Max. Board Width | ≤760 mm |
| Field of View | 0.53×0.4 mm to 3.4×2.5 mm |
| Minimum Measurable Line Width | ≥20 µm |
| Measurement Accuracy | ±1 µm |
| Pixel Resolution | 0.70–5.20 µm/pixel |
| Total Magnification Range | 70×–450× |
| Optical Zoom | 1.4×–9× Continuous |
| SPC Capability | Yes |
| Illumination | Red LED Targeting Light |
| Weight (system only) | 145 kg |
| Dimensions (W×D×H, excl. PC) | 960×700×1280 mm |
| Compliance | Designed for IPC-6012, IPC-A-600, and ISO 9001-aligned QA/QC workflows |
| Software | Proprietary ASIDA Vision Suite with Audit Trail & Export to CSV/XLSX |
| Brand | ASIDA |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XK23 |
| Pricing | Available Upon Request |
| Measurement Accuracy | ±1 µm |
| Pixel Resolution (XK23) | 0.4–2.6 µm/pixel |
| Total Magnification | 70–450× |
| Optical Zoom | 1.4–9× Continuous |
| Maximum Board Width | ≤760 mm |
| Field of View | 0.53×0.4 mm to 3.4×2.5 mm |
| Minimum Measurable Line Width | ≥20 µm |
| Instrument Dimensions (excl. PC) | 960×780×1280 mm |
| Weight | 190 kg |