| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZJD-C |
| Frequency Range | 100 kHz – 160 MHz |
| Q Factor Range | 1–1023 |
| Capacitance Measurement | 1 pF – 25 nF |
| Inductance Measurement | 1 nH – 140 mH |
| Main Tuning Capacitor Range | 17–240 pF |
| Accuracy | ±1 pF (≤150 pF), ±1% (>150 pF) |
| Signal Source | DDS Synthesized, Stability ±3×10⁻⁵ ±1 digit |
| Power Supply | 220 V ±10%, 50 Hz ±2.5 Hz |
| Power Consumption | ~25 W |
| Operating Temperature | 0–40 °C |
| S916 Dielectric Test Fixture | Parallel-plate Electrodes (Φ38 mm), Gap Adjustment ≥15 mm, Resolution 0.001 mm, tanδ ≤4×10⁻⁴ @ 1 MHz |
| LKI-1 Inductor Set | 10 Standard Inductors (0.05 μH to 10 mH) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V (adjustable) |
| Accuracy | ±1% |
| Display | Digital LCD |
| Dimensions | 285 mm × 245 mm × 120 mm |
| Weight | 4.5 kg |
| Compliance | GB/T 1410–2006, ASTM D257–99, GB/T 10581–2006, GB/T 1692–2008, GB/T 2439–2001, GB/T 12703.4–2010, GB/T 10064–2006 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | DC 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V (±10%) |
| Accuracy | ±1% (up to 10¹⁰ Ω), ±5% + 2 digits (10¹¹–10¹³ Ω), ±10–15% + 5 digits (>10¹⁴ Ω) |
| Display | Full-digit LCD, simultaneous resistance and current readout |
| Dimensions | 300 mm × 280 mm × 150 mm |
| Weight | ~3.0 kg |
| Power | AC 220 V, 50 Hz, ~10 W |
| Operating Environment | –10 °C to 50 °C, RH < 90% |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 |
| Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V (selectable) |
| Display | Digital LCD |
| Accuracy | ±1% |
| Compliance | GB/T 1410–2006, ASTM D257–99, GB/T 10581–2006, GB/T 1692–2008, GB/T 2439–2001, GB/T 12703.4–2010, GB/T 10064–2006, GB/T 22042–2008, EN 1149-1:1995, FZ/T 64013–2008, SJ/T 10694–2006 |
| Brand | Aerospace |
|---|---|
| Model | ZST-212 |
| Origin | Beijing, China |
| Category | Physical Property Testing Instrument |
| Price Range | USD 2,800 – 7,000 |
| Measurement Principle | Guarded DC Voltage Method (Three-Electrode System) |
| Compliance | ASTM D257, IEC 60093, GB/T 1410 |
| Resistance Range | 10⁴ Ω·m to 10¹⁶ Ω·m |
| Test Voltage | 10 V – 1000 V DC (adjustable in 10 V steps) |
| Environmental Control | Supports optional temperature/humidity chamber integration (23 °C ± 1 °C, 50 % RH ± 3 % RH) |
| Brand | AET |
|---|---|
| Origin | Japan |
| Model | Coaxial Resonant Cavity System |
| Frequency Range | 800 MHz – 9.4 GHz |
| Permittivity (ε′) | 1–15 |
| Accuracy | ±1% |
| Loss Tangent (tan δ) | 0.001–0.1 |
| Accuracy | ±5% |
| Resonant Modes | Type A (0.8 / 2.45 / 4.2 / 5.8 / 7.6 GHz) and Type B (1.0 / 3.1 / 5.2 / 7.3 / 9.4 GHz) |
| Measurement Principle | High-Q coaxial cavity resonance with 3D electromagnetic field simulation (CST Microwave Studio®) |
| Brand | AET |
|---|---|
| Origin | Japan |
| Model | Liquid Resonant Cavity System |
| Frequency Range | 1–10 GHz |
| Permittivity Range | 1–6 |
| Permittivity Accuracy | ±1% |
| Loss Tangent Range | 0.001–0.01 |
| Loss Tangent Accuracy | ±5% |
| Minimum Sample Diameter | >5.5 mm |
| Brand | AET |
|---|---|
| Origin | Japan |
| Model | Powder Resonant Cavity System |
| Frequency Range | 1–10 GHz |
| Permittivity Range | ε′ = 1–6 |
| Permittivity Accuracy | ±1% |
| Loss Tangent Range | tan δ = 0.001–0.01 |
| Loss Tangent Accuracy | ±5% |
| Minimum Sample Diameter | ≥5.5 mm |
| Sample Form | Powders (quartz tube loaded) and Low-Polarity Liquids |
| Brand | AET |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | TE Cavity Resonator |
| Price Range | USD 42,000 – 140,000 |
| Frequency Range | 10–40 GHz |
| Permittivity (εᵣ) | 1–5 |
| Accuracy | ±1% |
| Loss Tangent (tan δ) | 0.0001–0.01 |
| Accuracy | ±5% |
| Sample Thickness | 0.01–0.3 mm |
| Minimum Sample Size | 50×50 mm (at 10 GHz), 40×40 mm (at 20 GHz), 30×30 mm (at 28/40 GHz) |
| Compliance | JIS R1641, IPC-TM-650 2.5.5.13 |
| Measurement Geometry | In-plane (parallel to film surface) |
| Cavity Type | Split-cylinder TE-mode resonant cavity |
| Brand | AET |
|---|---|
| Origin | Japan |
| Model | TM010/TM011 Cavity Resonator |
| Frequency Range | 1–10 GHz |
| Permittivity (ε′) | 1–30 |
| Accuracy | ±1% |
| Loss Tangent (tan δ) | 0.0001–0.05 |
| Accuracy | ±5% |
| Compliance | JIS C2565, ASTM D2520 |
| Sample Form | Rectangular bar (non-destructive) |
| Q-Factor | High (>10,000 typical) |
| Cavity Customization | Frequency-specific cavity modules available |
| Brand | Akrometrix |
|---|---|
| Origin | USA |
| Model | TTSM |
| Measurement Principle | Non-contact shadow moiré interferometry |
| Temperature Range | Ambient to 300 °C (optional -50 °C to 300 °C) |
| Z-axis Resolution | ≤1.25 µm (AKM600P variant) |
| Field of View | Up to 600 mm × 600 mm (AKM600P), 48 mm × 64 mm (DFP), 70 mm circular (CRE) |
| Data Acquisition Speed | <2 s per full-field measurement (up to 1.4 million data points) |
| Compliance | JEDEC JESD22-B112, JEITA ED-7306, IPC TM-650 2.4.22 (Bow & Twist), IPC-9641, ASTM E2923 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDA-A |
| Price | USD 2,500 (approx.) |
| Brand | AMAE |
|---|---|
| Model | MI-200 |
| Flow Table Diameter | 254 mm ± 2.5 mm |
| Flow Table Thickness | 8 mm ± 0.1 mm |
| Drop Height | 12.5 mm ± 0.13 mm |
| Vibration Frequency | 25 Hz |
| Stroke Count Range | 1–9999 cycles (programmable) |
| Material | Brass flow table (Rockwell hardness ≥ HRB 25) |
| Compliance | ASTM C230-68, IMSBC Code Annex 1 (Moisture Content Testing for Flow Potential Assessment) |
| Sample Size Range | 1 mm ≤ particle size ≤ 7 mm |
| Environmental Requirement | Controlled temperature & humidity chamber, draft-free operation |
| Brand | AMAE |
|---|---|
| Model | MI-600 |
| Origin | Guangdong, China |
| Drive System | Hydraulic Accumulator |
| Tilt Range | 0–50° |
| Tilt Speed | Adjustable ≤ 0.3°/s |
| Angular Resolution | ≤ 0.5° |
| Test Chamber Dimensions | 600 × 400 × 200 mm (L×W×H) |
| Hydraulic Accumulator Dimensions | 500 × 500 × 450 mm (L×W×H) |
| Weight | 150 kg |
| Max Hydraulic Pressure | < 50 kPa/cm² |
| Sample Type | Non-cohesive granular solids ≤ 10 mm particle size |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | 128-105 |
| Channel Capacity | 128 independent DC resistance monitoring channels |
| Minimum Event Duration | 0.1 / 0.5 / 1.0 µs (field-replaceable clock modules support additional durations) |
| Threshold Resistance Range | 0.1–2000 Ω |
| Sensing Current Options | 1, 5, 10, 20, 50, 100 mA |
| Max Compliance Voltage | 2.5 V |
| Threshold Tolerance | ±5% |
| Event Detection Sensitivity | 100 ns |
| Operating Temperature | ≤35 °C |
| Power Supply | 120 VAC, 60 Hz, 6 A |
| Dimensions | 11.5" H × 18" W × 15.5" D |
| Weight | 51 lb |
| Interface | USB or RS-232C |
| Software | WinDatalog v5.x for data acquisition, event logging, and statistical analysis |
| Compliance | Designed for GLP/GMP-aligned test environments |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | 32-106 |
| Channel Capacity | 32 |
| Minimum Event Duration | 0.1 / 0.5 / 1.0 µs (field-replaceable clock module supports other durations) |
| Threshold Resistance Range | 0.1–2000 Ω |
| Channel Test Current | 1, 5, 10, 20, 50, 100 mA |
| Compliance Voltage | ≤2.5 V |
| Threshold Tolerance | ±5% |
| Interface | USB & RS-232C |
| Software | WinDatalog v5.x |
| Operating Temperature | ≤35 °C |
| Power Supply | 120 VAC, 60 Hz, 3 A |
| Dimensions (H×W×D) | 7.5″ × 18″ × 16.5″ |
| Weight | 26 lb |
| Warranty | 1 year parts and labor |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | STD Event Detectors |
| Pricing | Upon Request |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | STD Event Detectors Accessories |
| Type | Field-Upgradeable Hardware Modules and Interconnect Solutions for Electrical Continuity Interruption Testing |
| Compliance | Designed for use with ASTM F1978, IPC-TM-650 2.6.23, MIL-STD-883H Method 2014, and IEC 60068-2 environmental test correlation workflows |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | EK-300iD / GF-300D |
| Instrument Type | Buoyancy-Based Density Balance |
| Measurement Principle | Archimedes’ Principle |
| Weighing Capacity | 300 g (EK-300iD), 310 g (GF-300D) |
| Weighing Readability | 0.01 g (EK-300iD), 0.001 g (GF-300D) |
| Density Resolution | 0.001 g/cm³ |
| Display | Backlit LCD (16 mm character height, EK-iD series) |
| Stabilization Time | ≤1 s (GF-D series) |
| Internal Resolution | 1/10,000,000 |
| Environmental Response Modes | FAST / MID / SLOW |
| Calibration | Full-digital span calibration with user-adjustable reference weight input |
| Temperature Compensation | Direct water temperature or reference liquid density entry |
| Density Comparison Mode | Hi / OK / Lo alarm output (optional external relay module) |
| Auto Power-Off | Configurable after ≥10 min inactivity |
| Interface | RS-232C standard port |
| Software | WinCT v3.x (Windows-compatible, supports Excel/Office data export, statistical analysis, time-series logging, and chart-based visualization) |
| Compliance | Built-in GLP/GMP/ISO audit trail functions (date/time stamping, instrument ID, calibration history, operator ID, measurement statistics) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | ElaTest |
| Density Measurement Range | 0.8–2.6 g/cm³ |
| Temperature Range | 0–40.0 °C |
| Repeatability | ±0.00001 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 40–120 cm³ |
| Application | Density of uncured rubber and rubber compounds |
| Instrument Type | Benchtop Laboratory Densitometer |
| Detection Principle | Pneumatic (gas displacement) density measurement |
| Compliance | Designed for GLP/GMP environments with audit-ready data handling |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DMA 1002 |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Repeatability | ±0.00005 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Temperature Range | 15–60 °C |
| Temperature Stability | ±0.02 °C |
| Minimum Sample Volume | 1 mL |
| Display | 7″ TFT WVGA Touchscreen (800 × 480 px, PCAP) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DMA 1002/1102 Petro |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Category | Portable |
| Sample Type | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Temperature Range | 15 °C to 100 °C (59 °F to 212 °F) |
| Temperature Accuracy | ±0.03 °C (from +15 °C to +100 °C) |
| Density Resolution | 5 significant digits |
| Viscosity Range (DMA 1102 only) | –0.3 mm²/s to 1000 mm²/s |
| Viscosity Repeatability | ±0.2% |
| Minimum Sample Volume | 3.5 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP touch screen |
| Dimensions (L×W×H) | 365 mm × 265 mm × 180 mm |
| Weight | 6.6 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 1102 Petro |
| Instrument Type | Oscillating U-tube Densimeter |
| Application | Petroleum Products Density & Kinematic Viscosity Measurement |
| Detection Medium | Liquid |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Resolution | 5 significant digits |
| Temperature Range | 15 °C to 100 °C (59 °F to 212 °F) |
| Temperature Stability | ±0.03 °C over full range |
| Viscosity Range | −0.3 mm²/s to 1000 mm²/s |
| Viscosity Repeatability | ±0.2% |
| Minimum Sample Volume | 3.5 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Dimensions (L×W×H) | 365 × 265 × 180 mm |
| Weight | 6.6 kg |
| Power Supply | DC 24 V / 3 A |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 4002 / DMA 5002 / DMA 6002 |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Class | Benchtop Laboratory Densimeter |
| Sample Type | Liquid |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.00005 g/cm³ (DMA 4002), ±0.00001 g/cm³ (DMA 5002, 0–1.05 g/cm³ at 15–20 °C), ±0.000005 g/cm³ (DMA 6002, full range) |
| Temperature Range | 0 °C to 100 °C |
| Temperature Accuracy | ±0.02 °C (DMA 4002), ±0.01 °C (DMA 5002 & DMA 6002, 15–20 °C) |
| Density Repeatability (Std. Dev.) | 0.00001 g/cm³ (DMA 4002), 0.000003 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002) |
| Density Resolution | 0.00001 g/cm³ (DMA 4002), 0.000005 g/cm³ (DMA 5002), 0.000001 g/cm³ (DMA 6002) |
| Minimum Sample Volume | 1 mL |
| Display | 10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen |
| Compliance | ASTM D4052, D5002, D1250 |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | 0.0001 g/cm³ (DMA 4100M) / 0.00005 g/cm³ (DMA 4500M) / 0.000005 g/cm³ (DMA 5000M) |
| Temperature Range | 0 °C to 95 °C |
| Temperature Accuracy | ±0.05 °C (4100M) / ±0.03 °C (4500M) / ±0.01 °C (5000M) |
| Minimum Sample Volume | 1 mL |
| Repeatability (Std. Dev.) | 0.00005 g/cm³ (4100M) / 0.00001 g/cm³ (4500M) / 0.000001 g/cm³ (5000M) |
| Display | 10.4" PCAP TFT Touchscreen (640 × 480 px) |
| Compliance | FDA 21 CFR Part 11, GLP/GMP, ISO 12084, ASTM D4052, USP <841> |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA 4200 M |
| Instrument Type | Laboratory Benchtop Oscillating Tube Densitometer |
| Sample Type | Liquid (including high-viscosity, solid-at-room-temperature, and pressurized samples) |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.0001 g/cm³ |
| Density Repeatability | ≤0.00005 g/cm³ (standard deviation) |
| Temperature Range | −10 °C to +200 °C (14 °F to 392 °F) |
| Temperature Accuracy | ±0.03 °C |
| Pressure Range | 0–500 bar (0–7,250 psi) |
| Minimum Sample Volume | 2 mL |
| Measuring Cell Material | Hastelloy C-276 |
| Cell Volume | ~2 mL |
| Dimensions | 510 × 330 × 230 mm (20 × 13 × 8.7 in) |
| Weight | 27.1 kg (59.7 lb) |
| Power Supply | AC 100–240 V, 50–60 Hz, 250 VA |
| Interfaces | 4 × USB 2.0, 2 × S-Bus, 1 × Ethernet (100 Mbit), 1 × CAN Bus, 1 × RS-232, 1 × VGA |
| Brand | Anton Paar |
|---|---|
| Origin | Japan (manufactured in Austria) |
| Model | DMA 5001 |
| Instrument Type | Laboratory Benchtop Densitometer |
| Sample Type | Solid & Liquid Compatible |
| Measurement Principle | Oscillating U-tube (ASTM D4052, ISO 12185, USP <841>) |
| Density Range | 0 to 3 g/cm³ |
| Temperature Range | 0 °C to 100 °C |
| Accuracy (Density) | ±0.000005 g/cm³ |
| Repeatability (Density) | ±0.000001 g/cm³ |
| Minimum Sample Volume | ~1 mL |
| Display | 10.1″ TFT WXGA Touchscreen (1280 × 800 px) |
| Data Storage | >10,000 measurements with embedded camera images |
| Measurement Time | ≤40 s per sample |
| Operating System | Real-time embedded OS (8× faster than previous generation) |
| CPU | Dual-core processor (2× speed increase) |
| Compliant | FDA 21 CFR Part 11, GLP/GMP audit trail, ISO/IEC 17025 traceability support |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | DMA 502 |
| Instrument Type | Oscillating U-tube Density Meter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids and Low-Viscosity Suspensions |
| Density Range | 0 to 3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability | ±0.0002 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | 15–40 °C |
| Temperature Stability | ±0.1 °C |
| Minimum Sample Volume | 1 mL |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Environmental Compensation | Automatic pressure, altitude, and ambient humidity correction |
| Data Storage | 5000 measurements |
| Method Library | 400 pre-validated methods |
| Conversion Tables | 140 built-in (alcohol, sugar, acids, API gravity, etc.) |
| Compliance | ASTM D4052, ASTM D5002, USP <841>, EP/JP pharmacopoeial density requirements, FDA 21 CFR Part 11 (when used with AP Connect) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DMA 6002 Sound Velocity |
| Instrument Type | Oscillating U-tube Densimeter & Sound Velocity Analyzer |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids |
| Density Range | 0 g/cm³ to 3 g/cm³ |
| Sound Velocity Range | 1000 m/s to 2000 m/s |
| Temperature Range | 0 °C to 100 °C (32 °F to 212 °F) |
| Pressure Range | 0 bar to 8 bar (0 psi to 116 psi) |
| Density Accuracy | ±0.000005 g/cm³ |
| Density Repeatability (Std. Dev.) | ±0.000001 g/cm³ |
| Sound Velocity Repeatability (Std. Dev.) | ±0.1 m/s |
| Density Reproducibility (Std. Dev.) | ±0.000005 g/cm³ |
| Sound Velocity Reproducibility (Std. Dev.) | ±0.5 m/s |
| Density Resolution | 0.000001 g/cm³ |
| Sound Velocity Resolution | 0.01 m/s |
| Minimum Sample Volume | 3.5 mL |
| Measurement Throughput | Up to 30 samples/hour |
| Compliance | ISO 5725, ASTM D4052, ASTM D1250, ISO 12185, ISO 17025 (when operated with certified calibration standards) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | DMA35 |
| Instrument Type | Portable Digital Density Meter |
| Measurement Principle | Oscillating U-tube (OUM) |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability (std. dev.) | ±0.0005 g/cm³ |
| Temperature Range (Sample) | 0–40 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Repeatability | ±0.1 °C |
| Sample Volume | 1–2 mL |
| Resolution | 0.0001 g/cm³ (density), 0.1 °C (temperature) |
| Environmental Operating Range | −10 to +50 °C (standard) |
| Protection Rating | IP54 |
| ATEX/IECEx Certification | II 2G Ex ib IIB T4 Gb (DMA35 Ex & DMA35 Ex Petrol) |
| Data Storage | 1024 measurements, 30 methods, 250 sample IDs |
| Interface | Bluetooth®, RFID, IrDA |
| Power Supply | 3 × AA alkaline batteries (LR06) |
| Weight | 660 g |
| Dimensions (L×W×H) | 245 × 103 × 126 mm |