| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Modulyzer |
| Pricing | Upon Request |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Perfume and Flavor Measurement System |
| Instrument Type | Oscillating U-tube Densimeter |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Display | 10.1″ TFT WXGA (1280 × 800 px) PCAP Touchscreen |
| Temperature Control Range | 0–100 °C |
| Minimum Sample Volume | 2 mL |
| Integrated Parameters | Density, Refractive Index, Optical Rotation, Colorimetry, Turbidity |
| Automation | Fully Automated Sample Handling with Recovery (Xsample 5200/530), Integrated Cleaning & Drying |
| Brand | Anton Paar |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Ultrapyc Series |
| Instrument Type | True Density Analyzer |
| Instrument Class | Benchtop Laboratory |
| Sample Type | Solids (bulk & granular), Powders, Pastes, Slurries, Foams |
| Density Accuracy | ≤0.015% |
| Display | 7-inch TFT WVGA (800 × 480 px) PCAP Touchscreen |
| Temperature Range | 3–60 °C |
| Minimum Sample Volume | 0.1 cm³ |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Region Category | Domestic |
| Model | CHIRAD165 |
| Pricing | Upon Request |
| Max. X-ray Tube Voltage | 160 kV |
| Beam Angle | 40° |
| Max. System Power | 6000 W |
| Focal Spot Size | 5.5 mm |
| SSD (Source-to-Sample Distance) | OEM-defined |
| Dose Rate Range | >600 Gy/min |
| Real-time Dosimetry | Yes (dose rate, cumulative dose, irradiation time) |
| Cooling System | Integrated closed-loop heat exchanger |
| Stage | Motorized wafer stage with XYZ motion and ±45° rotation |
| Control System | PLC-based |
| Safety Interlocks | Door interlock + warning light |
| Chuck | Coaxial high-temperature vacuum chuck (OEM) |
| Microscope | PSM1000 stereomicroscope with 2-MP HDMI CCD (optional) |
| Microscope Stage | 2″ × 2″ XY travel |
| Vibration-Isolation Table | 900 mm × 800 mm (final dimensions subject to integration) |
| Probe Interface | 3-axis coaxial probe holder |
| Auxiliary Equipment | Air compressor included |
| Optional Accessories | Low/high-temperature coaxial chucks, semi-automated probe station, dry-air purge system |
| Brand | API |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HS-19GDV |
| Instrument Type | Shore Durometer (Type A & D) |
| Hardness Range | 14–115 Shore A / 20–85 Shore D (typical dual-scale calibration per ASTM D2240) |
| Display | LCD digital readout with statistical functions (mean, delete, hold) |
| Data Output | RS-232 interface for optional printer or PC connectivity |
| Hardness Conversion | Built-in algorithms for approximate conversion to Brinell (HB), Rockwell (HRB/HRC), and Vickers (HV) scales per ISO 14676 and ASTM E140 |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SI-111 |
| Operating Wavelength | 8–14 µm |
| Field of View | 22° half-angle |
| Accuracy | ±0.2 °C @ −10 to +65 °C |
| Repeatability | ±0.05 °C @ 10 to +65 °C |
| Response Time | <1 s |
| Output | 60 µV/°C (target), 0–2500 mV (sensor body temperature) |
| Housing | Anodized aluminum with germanium optical window |
| Dimensions | Ø23 mm × 60 mm |
| Weight | 190 g |
| Cable | 4.5 m, 4-conductor shielded |
| Operating Ambient | −55 to +80 °C, 0–100 % RH |
| Power Supply | 2.5 V excitation for thermistor |
| Brand | Applied NanoFluorescence |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Nano Spectralyzer NS3 |
| Pricing | Available Upon Request |
| Brand | AS ONE |
|---|---|
| Model | AD5680 |
| Temperature Range (Internal) | −10 to +50 °C |
| Temperature Range (External Probe) | −50 to +70 °C |
| Relative Humidity Range | 20–100 %RH |
| Display | Simultaneous Temperature (°C), Relative Humidity (%RH), and Real-Time Clock |
| Data Logging | Max/Min Hold Memory |
| Power Supply | Two AA Batteries (Included) |
| Mounting | Wall-Mountable or Desktop-Stable Design |
| External Sensor Cable Length | 3 m (Standard with Model 2-7397-01) |
| Dimensions (W×D×H) | 100 × 25 × 120 mm |
| Weight | 180 g |
| Brand | AS ONE |
|---|---|
| Model | CC-2544-01 |
| Temperature Range | −30 °C to +70 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Humidity Range | 0–100 %RH |
| Humidity Accuracy | ±3–5 %RH (at 23 °C ±2 °C) |
| Humidity Resolution | 1 %RH |
| Data Storage Capacity | 15,000 readings |
| Sampling Interval | 2 s to 24 h adjustable |
| Logging Start Mode | Immediate or Delayed (1–120 s) |
| Alarm Function | Configurable High/Low Thresholds with Visual Indication |
| Display | Dual-line LCD showing real-time temperature/humidity alternately |
| Power | Single AA alkaline battery (typical life ≥12 months at 10-min interval) |
| Weight | 150 g |
| Operating Environment | −30 °C to +70 °C |
| Storage Environment | −50 °C to +90 °C |
| Interface | USB 2.0 |
| Compliance | CE-marked, RoHS-compliant |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model No. | 1-624-01 |
| Instrument Type | Thermo-Hygrometer |
| Minimum Scale | Temperature ±2°C, Humidity ±5% RH |
| Accuracy | Temperature ±2°C |
| Mounting | Wall-Mounted |
| Dimensions | 180 × 180 × 35 mm |
| Brand | Asada |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JK3600 |
| Pricing | Available Upon Request |
| Detectable Hole Diameter Range | 0.15–10 mm |
| PCB Size Capacity | 100 × 150 mm to 630 × 650 mm |
| PCB Thickness Range | 0.3–10 mm |
| Max. Hole Count per Board | 150,000 |
| Inspection Speed | 3.5–12.5 m/min (adjustable) |
| Hole Position Repeatability | ±40 µm |
| Hole Dimension Tolerance | ±40 µm |
| Minimum Hole-to-Hole Edge Distance | 0.15 mm |
| Detection Method | Contact Image Sensor (CIS) Proximity Imaging |
| Light Source | Diffuse Long-Strip LED Array |
| Power Supply | AC 220 V, 50 Hz |
| Machine Dimensions (L×W×H) | 3550 × 1200 × 1100 mm |
| Compressed Air Requirement | 0.5–0.7 MPa |
| Weight | 450 kg |
| Brand | Asida |
|---|---|
| Model | CQ1000 |
| Application | Precision slitting and blanking of uncured fiberglass-reinforced epoxy prepreg (PP) rolls used in PCB and copper-clad laminate (CCL) manufacturing |
| Cutting Principle | Non-contact localized thermal softening followed by mechanical shearing |
| Max. Roll Diameter | 320 mm |
| Cutting Length | 50–750 mm |
| Cutting Width | 200–1270 mm |
| Material Thickness | 0.04–0.3 mm |
| Positioning Accuracy | ±1.0 mm |
| Web Speed | ≤60 m/min |
| Cycle Rate | ≤13 cuts/min (at 500 mm length) |
| Power Supply | 3-phase 5-wire, AC380 V / 50 Hz / ≥40 A |
| Compressed Air | 0.7–1.0 MPa |
| Ambient Requirements | 20 °C ±2 °C, 50 %RH ±5 %RH |
| Footprint | 2600 × 2300 × 1700 mm (L×W×H) |
| Weight | ~1500 kg |
| Avg. Power Consumption | ≤9 kW |
| Compliance | Designed for ISO 9001-aligned production environments |
| Brand | B&E / Balentine Enterprises |
|---|---|
| Origin | USA |
| Model | D3265 |
| Compliance | ASTM D3265-22 |
| Purity | ≥99.9% ZnO |
| Specific Surface Area | 2.97 m²/g |
| Moisture | 0.09% |
| Brand | ATEQ |
|---|---|
| Model | F5800-MR |
| Origin | France |
| Measurement Principle | Vacuum Decay |
| Compliance | ASTM F2338-09, FDA 21 CFR Part 11 (data integrity), ISO 8573-1 (air quality) |
| Test Volume | <7 mL |
| Sensitivity | ≥0.02 cc/min (equivalent to ~1.5 µm equivalent leak diameter) |
| Operating Temperature | 10–45 °C |
| Power Supply | 100–240 VAC, 50 W |
| Dimensions (W×H×D) | 450 × 150 × 356 mm |
| Weight | 20 kg |
| Display | Color touchscreen HMI |
| Pressure Sensors | Dual high-stability absolute pressure sensors |
| Data Traceability | Audit trail, electronic signatures, method versioning |
| Validation Support | IQ/OQ/PQ documentation package, 3Q validation-ready |
| Brand | ATEQ |
|---|---|
| Model | F6900-EC |
| Origin | France |
| Type | Vacuum Decay Leak Detection System |
| Compliance | ASTM F2338-09 |
| Internal Volume | Minimized Dead Volume |
| Power Supply | 100–240 VAC, 50 W |
| Drive Air Pressure | 400–600 kPa |
| Test Air Pressure | +1–2 bar above test pressure |
| Air Quality | ISO 8573-1 Class 4 or better |
| Operating Temperature | 10–45 °C |
| Storage Temperature | 0–60 °C |
| HMI | Color TFT Display with Intuitive Menu Navigation |
| Optional Accessories | Micro-flowmeter, Custom Vial Test Chamber, Certified Leak Standards |
| Brand | ATLANTEK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Model 400 |
| Pricing | Available Upon Request |
| Printing Method | Direct Thermal Printing |
| Print Resolution | 300 dpi |
| Print Width | 53 mm |
| Sample Width Capacity | 100 mm |
| Print Head Technology | Thin-Film Resistive (Corner-Type) |
| Print Speed Options | 10 in/s (programmable at three discrete settings) |
| Adjustable Parameters | Print Head Pressure, Print Head Position |
| Interface | RS-232 Serial |
| Power Supply | 115 V / 60 Hz or 220 V / 50 Hz |
| Test Patterns | Checkerboard, Solid Fill, UPC-A Barcode, User-Defined Patterns |
| Test Modes | Dynamic Reaction Sequence (10 energy steps), Full-sequence or single-step execution, repeat counts per step: 1×, 5×, or 10× |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 2/3 Column |
| Density Range | 0.8–3.3 g/cm³ (dependent on selected gradient liquid mixture and calibrated sinkers) |
| Accuracy | ±0.0001 g/cm³ at 23.0 ± 0.1 °C |
| Temperature Control | Digital, 5–50 °C ±0.1 °C |
| Bath Volume | ~45 L (transparent acrylic) |
| Cooling | External coil heat exchanger |
| Agitation | Integrated circulation pump |
| Sample Handling | Motorized lift system for sinkers and specimens |
| Gradient Column | Calibrated glass tube, 850 mm total length |
| Accessories | Precision column filling system, NIST-traceable calibrated sinkers |
| Brand | Auniontech |
|---|---|
| Model | AR-2000 |
| Temperature Range | 500–1500 °C (custom ranges available) |
| Optical Fiber Probe Length | 2 m (custom lengths available) |
| Working Distance | 400 mm |
| Spot Size | 5 mm @ 400 mm |
| Spectral Bands | 1.3 µm & 1.5 µm |
| Laser Safety Class | 3B (measuring beam), Class 2 (aiming laser) |
| Temperature Resolution | 1 °C |
| Typical Uncertainty | ±10 °C @ 1500 °C |
| Measurement Rate | 10 Hz (100 Hz optional) |
| Output Interfaces | 4–20 mA, 0–10 V, Ethernet |
| Data Storage | SD card (up to 32 GB) |
| Display | 7-inch touchscreen or remote PC interface |
| Dimensions (electronics unit) | 210 × 140 × 250 mm |
| Weight | 2.5 kg |
| Operating Ambient | 15–30 °C |
| Power Supply | 80–260 V AC to 24 V DC adapter |
| Brand | Balentine Enterprises (B&E) |
|---|---|
| Origin | USA |
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | D3265 ZnO |
| Price | Upon Request |
| Specific Surface Area | 2.97 m²/g |
| Pb Content | ≤0.0011% |
| Cd Content | <0.0001% |
| Fe Content | <0.0001% |
| Moisture | 0.09% |
| ZnO Purity | >99.9% |
| +325 Mesh Retain | <0.0001% |
| Brand | Bareiss |
|---|---|
| Origin | Germany |
| Model | digi test II |
| Force Range Options | 0–2 N or 0–20 N (user-swappable load modules) |
| Test Principle | Axial compression with controlled displacement rate |
| Display | LCD (240 × 128 pixels) |
| Dimensions (Base Unit) | 200 × 250 × 570 mm |
| Weight (Base Unit) | 9 kg |
| Housing Material | Anodized aluminum alloy |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Communication Interfaces | RS-232, USB |
| Compliance | Designed for GLP-compliant capsule quality control in pharmaceutical R&D and manufacturing |
| Brand | Bareiss |
|---|---|
| Origin | Germany |
| Model | DT Chamber |
| Temperature Range | -70 °C to +180 °C (customizable) |
| Hardness Scales | Shore A, Shore D, IRHD |
| Sample Capacity | Up to 25 specimens (customizable) |
| Test Modes | Single-point, continuous, programmable, hysteresis recovery (IRHD) |
| Instrument Type | Shore / IRHD Hardness Tester |
| Brand | Bareiss |
|---|---|
| Origin | Germany |
| Model | HDA 325 |
| Hardness Measurement Principle | Shore A (ASTM D2240, ISO 7619-1) |
| Density Measurement Principle | Archimedes’ Principle with Precision Buoyancy Weighing |
| Cycle Time (Hardness + Density) | <20 s per sample |
| Dual-Channel Density Option | ~10 s per sample |
| Operating Duty Cycle | 24/7/365 continuous operation |
| Temperature Monitoring Option | Integrated surface temperature sensor (range: 20–70 °C, resolution: ±0.1 °C) |
| Data Traceability | Sample ID, timestamp, operator ID, environmental metadata |
| Compliance | ISO/IEC 17025-ready architecture, supports GLP/GMP audit trails, FDA 21 CFR Part 11 compliant data handling (with optional electronic signature module) |
| Brand | Beijing North Guang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BEST-911 |
| Price | USD 3,500 (FOB Beijing) |
| Measurement Range | 10⁻⁹ Ω·m to 10¹¹ Ω·m |
| Accuracy | ±1% to ±5% |
| Electrometer Input Resistance | ≥10¹⁴ Ω |
| Electrometer Voltage Range | ±100 mV to ±200 V |
| Picoammeter Sensitivity | 1 fA (1×10⁻¹⁵ A) |
| Adjustable DC Voltage Source Accuracy | ±1% |
| Electrode Configuration | Standard Four-Electrode Fixture Included |
| Current Electrode Spacing | 100 mm |
| Potential Electrode Spacing | 20 mm |
| Insulating Base Resistivity | ≥10¹⁴ Ω·m |
| Applied Test Pressure | 3.25 N |
| Net Weight | 331 g |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | LIT MK 240 |
| Temperature Range | −40 °C to +110 °C (extendable to +120 °C with dual safety cut-off) |
| Temperature Uniformity | ±0.1 K to ±1.2 K (dependent on setpoint) |
| Temperature Stability | ±0.1 K to ±0.5 K |
| Heating Rate (IEC 60068-3-5) | 5 K/min |
| Cooling Time (110 °C → −40 °C) | 160 min |
| Average Cooling Rate (IEC 60068-3-5) | 3.5 K/min |
| Thermal Compensation at 25 °C | 3000 W |
| Rated Voltage | 400 V or 480 V AC, 3~ |
| Frequency | 50/60 Hz |
| Nominal Power | 5.6 kW |
| Fuse Rating | 16 A |
| Internal Volume | 228 L |
| Net Weight (empty) | 375 kg |
| Max. Load Capacity | 70 kg |
| Shelf Load per Rack | 30 kg |
| Viewing Window | 508 mm × 300 mm (heated, LED-lit) |
| Internal Dimensions (W×H×D) | 735 mm × 700 mm × 443 mm |
| External Dimensions (W×H×D) | 1335 mm × 1929 mm × 925 mm |
| Rear Clearance | 300 mm |
| Side Clearance | 200 mm |
| Sound Pressure Level | 62 dB(A) |
| Safety Systems | Dual independent Class 2 temperature cut-offs (DIN 12880), CO/H₂/O₂/temperature gas monitoring, CO₂ fire suppression, reinforced door lock, reversible stainless-steel pressure relief valve, APT.line™ pre-heating chamber, condensation protection programming, fluorine-free refrigerant R-452A |
| Control Interface | Touchscreen controller with time-segment & real-time programming, APT-COM™ Basic software, Ethernet interface, USB data export (open CSV format), internal datalogger, 230 V socket on right-side panel |
| Standard Equipment | 1 stainless-steel shelf, compressed-air-cooled refrigeration unit |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | LIT MK 720 |
| Temperature Range | –40 °C to +110 °C |
| Temperature Uniformity (±K) | 0.1–0.5 |
| Temperature Stability (±K) | 0.3–2.0 |
| Avg. Heating Rate (IEC 60068-3-5) | 4 K/min |
| Avg. Cooling Rate (IEC 60068-3-5) | 3.4 K/min |
| Internal Volume | 734 L |
| Max. Load Capacity | 160 kg |
| Net Weight | 570 kg (LIT MK 720-400V) / 522 kg (LIT MK 720-480V-C) |
| Power Supply | 400 V, 3~ |
| Refrigerant | R-452A |
| Sound Pressure Level | 65–67 dB(A) |
| Brand | Biuged |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BGD 309 |
| Cupping Punch Diameter | 20 mm |
| Maximum Indentation Depth | 12 mm |
| Depth Resolution | 0.01 mm (via high-precision linear position sensor) |
| Depth Graduation | 0.1 mm |
| Maximum Test Force | 2500 N |
| Specimen Thickness Range | 0.3–1.25 mm |
| Dimensions (L×W×H) | 290 × 240 × 370 mm |
| Net Weight | 28 kg |
| Brand | Biuged |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | BGD 310 |
| Price | Upon Request |
| Punch Diameter | 20 mm |
| Maximum Indentation Depth | 18 mm |
| Depth Resolution | 0.01 mm |
| Maximum Punch Force | 2500 N |
| Specimen Thickness Range | 0.3–1.25 mm |
| Specimen Width Capacity | up to 90 mm |
| Stroke Adjustment Range | 0–18 mm |
| Positioning Accuracy | ±0.01 mm |
| Dimensions (L×W×H) | 466 × 322 × 500 mm |
| Net Weight | 52 kg |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | DV2T Gel Timer |
| Price | Upon Request |
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BI-870 |
| Measurement Range | 1–20 and 1–200 |
| Accuracy | ±2% |
| Repeatability & Linearity | ±0.2% |
| Max Sample Conductivity | 1 µS/cm (for range 1–20), 10 µS/cm (for range 1–200) |
| Minimum Sample Volume | 25 mL |
| Probe Material | Stainless Steel & PTFE |
| Excitation Signal | Low-distortion 10 kHz sine wave (7 Vrms for 1–20 range |
| Display | LCD |
| Brand | A2PS/A2 Photonic Sensors |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | BUZZ-1015 |
| Pricing | Upon Request |
| Measurement Principle | Impulse Excitation / Laser Doppler Vibrometry |
| Frequency Range | 0.5 Hz – 2.5 MHz |
| Accuracy | Better than ±1.0% (resonance frequency), ±0.1% typical for fundamental mode identification |
| Test Duration | Seconds per measurement |
| Damping Factor Range | 10⁻⁵ – 10⁻¹ |
| Sample Dimensions | ≤ 200 × 180 × 180 mm (rectangular or cylindrical) |
| Temperature Range | Ambient to 1500 °C (protection limit) |
| Vacuum Level | < 1 × 10⁻² Pa (operational), < 5 × 10⁻⁸ Torr (base pressure) |
| Compliant Standards | ASTM C1259, ASTM E1876, ISO 12680 |