Other Physical Property Test Instruments
Filter
Showing 121–150 of 202 results
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiReader X-Ray |
| Pricing | Upon Request |
| Brand | MAYZUM |
|---|---|
| Model | MAYA203DIV2L |
| Type | Benchtop Solid Density Analyzer for Hydrogen Quantification in Aluminum Melts |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Range | −30 °C to +60 °C |
| Display | Digital LCD |
| Origin | Guangdong, China |
| Manufacturer | MAYZUM (OEM/ODM Capable) |
| Compliance | GB/T 43139–2023, GB/T 5611–2017, ASTM E807 (adapted), ISO 11922 (principles) |
| Brand | MAYZUM |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MAYB124G |
| Instrument Type | Laboratory Benchtop Buoyancy-Based Densimeter |
| Sample Type | Liquids Only |
| Density Range | 0.0001–3.0000 g/cm³ (equivalent to 0.1–100% concentration for common aqueous/organic solutions) |
| Maximum Sample Weight Capacity | 120 g |
| Density Resolution | 0.0001 g/cm³ |
| Display | Digital LCD |
| Compliance Standards | GB/T 13531, GB/T 5526, GB/T 5009, ASTM D1298, ASTM D4052, JIS K 0061, ISO 12185 |
| Measurement Principle | Archimedean buoyancy displacement method |
| Brand | Mayzum |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MZ-Y300 |
| Instrument Category | Laboratory Benchtop Buoyancy-Based Densimeter |
| Sample Type | Solid Porous Materials |
| Density Range | 0.01–99.999 g/cm³ |
| Maximum Capacity | 300 g |
| Density Resolution | 0.001 g/cm³ |
| Display | Digital LCD |
| Application Scope | Universal Density Testing for Open- and Closed-Cell Porous Polymers |
| Compliance Context | Designed to support ASTM D3574, ISO 845, ISO 1183-1, and GB/T 6343 test protocols |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito / Densito Pro |
| Density Measurement Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Temperature Range | 0–50.0 °C |
| Minimum Sample Volume | 2 mL |
| Instrument Type | Portable Digital Density Meter (Oscillating U-tube Principle) |
| Application Scope | Liquid Density Measurement for QC/QA in Lab, Field, and Production Environments |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable data management |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito |
| Instrument Type | Portable Digital Density Meter |
| Sample Type | Solids and Liquids |
| Density Range | 0.000–3.000 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Density Repeatability | ±0.0005 g/cm³ |
| Operating Temperature Range | −10 °C to +50 °C |
| Measurement Units | g/cm³, g/mL, kg/m³, °Brix, API, °Baumé, % ethanol (v/v), % H₂SO₄, US/UK Proof, Plato, specific gravity, user-defined concentration scales |
| Data Storage Capacity | 1100 measurements with sample ID, temperature correction factor, instrument ID, timestamp, and unit |
| Display | Full-color backlit LCD |
| Language Support | English, Chinese, German, Spanish, French, Italian, Portuguese, Indonesian, Korean, Polish, Russian, Thai, Turkish |
| Connectivity | USB, optional printer output, compatible with EasyDirect PC software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D4 / D5 / D6 |
| Instrument Type | Benchtop Laboratory Density Meter |
| Sample Type | Solid and Liquid |
| Temperature Range | 0–95 °C (32–203 °F) |
| Repeatability | ±0.00005 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Density Range | 0.000–3.000 g/cm³ |
| Accuracy | ±0.0001 / ±0.00005 / ±0.000005 g/cm³ (model-dependent) |
| Temperature Accuracy | ±0.03 / ±0.02 / ±0.01 °C (model-dependent) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D4/D5/D6 |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Oscillating U-tube (ASTM D4052, ISO 12185, USP <841>) |
| Sample Type | Liquids and Low-Viscosity Solutions |
| Density Range | 0 to 3 g/cm³ |
| Density Resolution | 0.0001 g/cm³ |
| Temperature Control Range | 0 °C to 95 °C |
| Minimum Sample Volume | 1.5 mL |
| Compliance | 21 CFR Part 11 Ready (with LabX software), GLP/GMP Audit Trail Capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Densito / DensitoPro |
| Density Range | 0.000–3.000 g/cm³ |
| Accuracy | ±0.001 g/cm³ |
| Repeatability | ±0.0005 g/cm³ |
| Sample Temperature Range | 0–50 °C |
| Ambient Temperature Range | Densito: −10–50 °C |
| DensitoPro | 0–50 °C |
| Data Storage Capacity | 1,100 results |
| Supported Units | Density, Specific Gravity, Brix, API Gravity, Baumé, Ethanol (% v/v), H₂SO₄ Concentration, US/UK Proof, Plato, User-Defined Concentrations |
| Display | Full-color backlit LCD |
| Languages | English, Chinese, German, Spanish, French, Italian, Portuguese, Indonesian, Korean, Polish, Russian, Thai, Turkish |
| Connectivity | USB, Bluetooth (DensitoPro), RFID/Barcode Reader (DensitoPro only) |
| Software Integration | EasyDirect PC Software |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready data export |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | D30/D40 |
| Instrument Type | Laboratory Benchtop Digital Density Meter |
| Measurement Principle | Oscillating U-tube (Digital Vibrating Tube) |
| Sample Type | Liquids |
| Density Range | 0 to 3 g/cm³ |
| Density Resolution | 0.00001 g/cm³ |
| Density Accuracy | ±0.00002 g/cm³ |
| Temperature Control Range | 0 to 91.0 °C |
| Temperature Stability | ±0.01 °C |
| Minimum Sample Volume | 1 mL |
| Compliance | ASTM D4052, ISO 12185, USP <841>, IP 160, DIN 51757 |
| Data Management | FDA 21 CFR Part 11 compliant software support (via EasyDirect™), GLP/GMP audit trail capable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy D30, Easy D40 |
| Instrument Type | Benchtop Digital Density Meter |
| Sample Type | Solid and Liquid |
| Density Range | 0–3 g/cm³ |
| Temperature Range | 15–25 °C (Easy D30), 15–50 °C (Easy D40) |
| Density Resolution | 0.001 g/cm³ (Easy D30), 0.0001 g/cm³ (Easy D40) |
| Density Accuracy | ±0.001 g/cm³ (Easy D30), ±0.0005 g/cm³ (Easy D40) |
| Temperature Accuracy | ±0.2 °C (Easy D30), ±0.1 °C (Easy D40) |
| Minimum Sample Volume | 1.2 mL |
| Measurement Units | Density, Specific Gravity, Alcohol % v/v, Brix, API Gravity, Acidity, Urea Concentration, Custom Concentration |
| Built-in Methods | 16 |
| Bubble Detection | BubbleCheck™ (Easy D40 only) |
| Viscosity Correction | Automatic (both models) |
| Cleaning Check | Yes (both models) |
| Dimensions (W × H × D) | 170 × 156 × 273 mm |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Series | FillPal™, InMotion™, SC1(H), SC30(H) |
| Application Scope | Fully automated sample introduction, rinsing, drying, and (where applicable) heating for density and refractive index measurement |
| Compliance Context | Designed to support GLP/GMP workflows with audit-trail-capable software integration |
| Fluid Handling Architecture | Positive-pressure filling (SC-series), peristaltic pumping (FillPal/InMotion), chemically resistant wetted materials (e.g., PTFE, ETFE, sapphire, Hastelloy C-276 where specified) |
| Temperature Control | Ambient-only (FillPal, InMotion, SC1/SC30) or heated up to 100 °C (SC1H/SC30H) |
| Sample Capacity | 1 (FillPal, SC1, SC1H) or up to 303 positions (InMotion), or 30 vials (SC30, SC30H) |
| Cleaning Protocol | Full-cycle automated rinse-dry sequence with configurable solvent selection and dwell times |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | SC1 / SC30 |
| Sample Capacity | 1 vial (20 mL, 9 mL, or 6 mL) |
| Maximum Sample Viscosity | ≤ 30,000 mPa·s |
| Sample Introduction Method | Positive-pressure pumping |
| Cleaning Protocol | Dual-solvent automated rinse and dry |
| Drying Method | Pneumatic-assisted air-drying |
| Temperature Control | Optional electric heating module (for sample pre-conditioning) |
| Sample Recovery | Optional automatic return to source vial |
| Compliance | Designed for integration with METTLER TOLEDO DE (density), RE (refractometry), and DR (combined density/refractometry) instruments |
| Brand | Kägi |
|---|---|
| Origin | Germany |
| Model | Micro IRHD |
| Instrument Type | Microindentation Hardness Tester for Elastomers |
| Standards Compliance | DIN ISO 48, ISO 48:2018, ASTM D1415-19, BS 903-A26 |
| Sample Thickness Range | 1–5 mm (recommended), up to 90 mm (with optional fixtures) |
| Resolution | 0.1 Micro IRHD |
| Dimensions (Tester) | Ø200 mm × 470 mm |
| Dimensions (Controller) | 290 mm × 260 mm × 75 mm |
| Weight | 17.5 kg |
| Control Interface | RS232 serial communication with Windows PC |
| Automation | Motorized Z-stage, programmable dual-weight actuation, auto-positioning sample stage |
| Software Platform | Native MS Windows application with real-time data acquisition, statistical analysis, hysteresis calculation, report generation (PDF/CSV), label printing, and ASCII export |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASAP 2020 |
| Pricing | Available Upon Request |
| Brand | Microtrac |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BELPYCNO L |
| Instrument Type | True Density Analyzer |
| Instrument Class | Benchtop Laboratory Analyzer |
| Sample Type | Solids, Powders, Pastes, Liquids |
| Measurement Principle | Gas Displacement Pycnometry (Helium-Based) |
| Pressure Range | Vacuum to 2.5 bar |
| Temperature Control Range | 14–40 °C (Peltier-Driven, Optional) |
| Temperature Stability | ±0.01 °C |
| Density Accuracy | ±0.01% |
| Density Repeatability | ±0.01% |
| Resolution | 0.01% |
| Minimum Sample Volume | 0.3 cm³ |
| Standard Sample Cell Volumes | 20 mL, 40 mL, 60 mL |
| Optional Sample Cell Volumes | 4 mL, 100 mL |
| Reference Cell Configuration | Three Integrated Reference Cells |
| Pressure Sensor | High-Stability Absolute Sensor (0–2.5 bar), 19-bit A/D, Drift ≤ ±0.02 mbar |
| Gas Options | He (standard), N₂, SF₆ |
| Inlet Pressure Range | 160–240 kPa (1.6–2.4 bar) |
| Compliance | ASTM D5550, ISO 12154, USP <699>, ISO 4590, ASTM D6226-10 |
| Interface | RS-232 (COM) or USB |
| Dimensions (W×H×D) | 25 × 33 × 45 cm |
| Weight | 17 kg |
| Operating Environment | 15–30 °C, 20–80% RH |
| Power | 85–264 VAC, 50/60 Hz, 240 W |
| Brand | Microtrac |
|---|---|
| Model | BELPYCNO |
| Type | Benchtop True Density Analyzer for Solids |
| Measurement Principle | Gas Pycnometry (Helium/Nitrogen/SF₆) |
| Density Range | All Solid Materials |
| Density Accuracy | ±0.0001 g/cm³ |
| Repeatability | ±0.01% (RSD) |
| Resolution | 0.01% |
| Minimum Sample Volume | 0.3 cm³ |
| Temperature Range | 15–35 °C (standard) |
| Pressure Range | Atmospheric to 150 kPa |
| Safety Features | Integrated pressure relief valve |
| Calibration Standards | Internal calibration spheres (multiple sizes) |
| Compliance | ASTM D5550, ISO 12154, USP <699>, ISO 18857-1 |
| Software | BELPyCNOSoft v3.x with audit trail, user management, and 21 CFR Part 11 compliance options |
| Brand | 3i |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NMI CRYOSTAT: CRYOGENFREE ULTRA LOW-VIBRATION CRYOS |
| Maximum Magnetic Field | 14.0 T |
| Temperature Range | 1.3 K to 300 K |
| Sample Diameter | Up to 49 mm |
| VTI Configuration | Top-Loading Variable-Temperature Insert |
| DSV Homogeneity | ≤0.1% over 1 cm |
| Brand | 3i |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 2 AXIS PIEZO ROTATOR |
| Pricing | Upon Request |
| Rotation Range (per axis) | ±90° |
| Angular Resolution | 1 µdeg (0.000001°) |
| Operating Temperature Range | 10 mK – 300 K |
| Maximum Magnetic Field Compatibility | 15 T |
| Compatible Carrier | Standard 20-pin Leadless Chip Carrier (LCC) |
| Drive Mechanism | Piezoelectric Motor |
| Controller Interface | USB 2.0 |
| Brand | North Guangjingyi / All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GDAT-C2 |
| Price | USD 4,950 (approx.) |
| Power Supply | AC 220 V ±10%, 50/60 Hz ±1% |
| Dimensions | 450 × 410 × 320 mm |
| Weight | 25 kg |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <75% RH |
| Capacitance Range | 5–200 pF |
| Relative Permittivity Range | 1.000–30.000 |
| Dissipation Factor Range | 1×10⁻⁵–100 |
| DC Resistivity Range | 2.5 MΩ·m–20 TΩ·m |
| Temperature Control Range | 0–125 °C |
| Temp. Accuracy | ±0.5 °C |
| AC Test Voltage | 200–2200 V (50 Hz, continuously adjustable) |
| DC Test Voltage | 0–500 V (continuously adjustable) |
| Heating Method | Medium-frequency induction with PID control |
| Electrode Configuration | Three-electrode cell per GB/T 5654–2007, 2 mm inter-electrode gap |
| Internal Standard Capacitor | SF₆-filled three-terminal capacitor |
| Data Storage | Onboard non-volatile memory with real-time clock (RTC) |
| Display | 5.7″ TFT color touchscreen, full Chinese GUI |
| Compliance | GB/T 5654–2007, ASTM D924, IEC 60247, ISO 6296 |
| Brand | Novocontrol Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | novocontrol GmbH |
| Frequency Range | 3 µHz – 40 MHz (up to 3 GHz with Keysight E4991B Impedance Analyzer) |
| Temperature Range | −160 °C to +1600 °C |
| Impedance Range | 10 mΩ to 100 TΩ |
| Measurement Voltage | 10⁻⁶ V to 3 V RMS |
| DC Bias Voltage | ±40 V |
| Software | Novocontrol WinDETA v5.x with real-time multi-parameter acquisition (≥30 parameters) |
| Compliance | Fully compatible with ASTM D150, ISO 257-1/2, IEC 60250, and supports GLP/GMP audit trails per FDA 21 CFR Part 11 |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | 500o / 500o HR / 500o XY |
| Measurement Principle | Digital Image Analysis (Static Imaging) |
| Dry Dispersion | Integrated Vacuum-Based System |
| Wet Dispersion | Computer-Controlled Syringe Pump with Three-Way Valve |
| Optical Configuration | Collimated 440 nm Blue LED Backlight (Transmitted) + Diffuse White LED (Reflected) |
| Camera | Progressive Scan CMOS (6.6 MP for 500o |
| Lens | Zoom Telecentric Objective |
| Pixel Resolution Range | 0.19–4.7 µm/pixel (model-dependent) |
| Field of View | Up to 10.27 × 14.00 mm (low-mag) down to 730 × 522 µm (high-mag) |
| Dry Mode Range | 0.2–3000 µm |
| Wet Mode Range | 0.8–300 µm |
| Reflectance Mode Range | 1–3000 µm |
| Analysis Time | 1–3 min per sample |
| Software | Callisto 2D (500o, 500o HR) or Callisto 3D (500o XY) |
| Compliance | ISO 13322-1 & ISO 13322-2, FDA 21 CFR Part 11 (audit trail, electronic signature, user access control), GLP/GMP-ready 3Q Validation (IQ/OQ/PQ) |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | FC200 Series |
| Particle Size Range | 0.2 µm – 3 mm |
| Imaging Resolution | Down to 0.17 µm/pixel |
| Number of Morphological Parameters | 50–80 |
| Sample Volume Range | Microliter to >1 L |
| Maximum Undiluted Sample Concentration | 5% (v/v) |
| Light Source | 440–450 nm Collimated Blue LED |
| Camera Options | 5–12 MP CMOS/CCD |
| Software Platform | Callisto 2D/3D |
| Regulatory Compliance | 21 CFR Part 11, IQ/OQ/PQ (3Q) Validation Support |
| Pump Types | Peristaltic, Diaphragm, Syringe, or Integrated Injection Pumps |
| Temperature Control (FC200TC) | Ambient to 140 °C |
| Specialized Configurations | FC200M+(HR), FC200S+(HR), FC200TC, FC200P, FC200BAG, IPAC 1, IPAC 2 CMP |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | SCAN Series |
| Particle Size Range | 10 µm – 50 mm (extendable to 2 µm – 20 cm) |
| Optical Resolution | Up to 600 Mpx (Scan 700) |
| Illumination | Broadband white light (350–640 nm), transmission + reflection modes |
| Imaging Sensor | High-speed CCD linear array |
| Software | Callisto 2D/3D |
| Dispersion | Dry-mode linear disperser with anti-adhesion metal coating |
| Sample Stage | 242 × 320 mm (Scan 700) |
| Compliance | ASTM D7927, ISO 9276-6, USP <1788>, GLP-ready audit trail in Callisto |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | Zephyr LDA / Zephyr ESR / Morpho 3 |
| Dry Measurement Range (Zephyr LDA) | 7 µm – 5000 µm |
| Wet Measurement Range (Zephyr LDA) | 1 µm – 3000 µm |
| Dry Measurement Range (Zephyr ESR) | 30 µm – 30 mm (extendable lower limit) |
| Dry Measurement Range (Morpho 3) | 500 µm – 10,000 µm |
| Analysis Time | 1–3 min per sample |
| Camera System | 5 MP CCD (Zephyr LDA/ESR), dual 1.3 MP (Morpho 3: 24-bit color front + 8-bit monochrome side) |
| Light Source | 440 nm blue LED (Zephyr LDA/ESR), dual diffuse white LED + monochromatic LED (Morpho 3) |
| Lens Type | Telecentric (Zephyr LDA), dual telecentric (Zephyr ESR), fixed-focus (Morpho 3) |
| Dispersion | Vibratory feed + transverse vacuum (Zephyr LDA), gravity-assisted vibration (Zephyr ESR), controlled rotary vibration + linear belt transport (Morpho 3) |
| Auto-Cleaning | Compressed air + vacuum (all models) |
| Software | Callisto 3D |
| Compliance | ISO 13322-2, ASTM E2927, FDA 21 CFR Part 11 (with optional 3Q validation: IQ/OQ/PQ) |
| Dimensions & Weight | Zephyr LDA: 85 × 47 × 64 cm, 52 kg |
| Zephyr ESR | 80 × 44 × 60 cm, 43 kg |
| Morpho 3 | 99 × 52 × 60 cm, 75 kg |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GYZJ-934-1 |
| Pricing | Available Upon Request |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | HBRV-187.5 |
| Type | Combined Brinell, Rockwell & Vickers Hardness Tester |
| Drive | Motorized Load Application |
| Compliance | ASTM E10, ASTM E18, ASTM E92, ISO 6506, ISO 6508, ISO 6507 |
| Application Scope | Ferrous & Non-ferrous Metals, Heat-Treated Surfaces, Thin Hardened Sheets, Cast Iron, Carbides, Annealed & Tempered Steels |
| Brand | OLYMPUS |
|---|---|
| Origin | Japan |
| Model | HBS-3000 |
| Hardness Scale | HBW (Brinell, tungsten carbide ball indenter) |
| Test Force Range | 187.5 kgf to 3000 kgf (standard Brinell load range per ISO 6506-1) |
| Indenter | 10 mm hardened steel or tungsten carbide ball |
| Optical Measurement System | High-magnification eyepiece with calibrated scale or digital image capture (optional) |
| Display | Large LCD screen with real-time test parameter and result visualization |
| Data Output | RS-232 or USB interface for printer or PC connectivity |
| Compliance | Designed to meet ISO 6506-1, ASTM E10, and JIS Z 2243 requirements |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | LEEB140 |
| Hardness Scales | HL, HB, HRB, HRC, HV, HS |
| Display | Full Chinese LCD Menu Interface |
| Printer | Built-in High-Speed Thermal Printer |
| Environmental Rating | Vibration-Resistant, Shock-Resistant, EMI-Immune |
| Portability | Handheld, Battery-Powered |
| Compliance | ISO 16859, ASTM A956 (Leeb Method) |
| Data Traceability | On-device Printout with Timestamp & Sample ID Support |
| Power Supply | Rechargeable Li-ion Battery |
| Brand | Olympus |
|---|---|
| Origin | Japan |
| Model | Leeb810A |
| Type | Shore A Hardness Tester |
| Display | Digital LCD |
| Application Scope | Rigid Plastics, Hard Rubbers, Coatings, and Polymer-Based Industrial Materials |
| Compliance | ASTM D2240, ISO 7619-1, ISO 868 |
